Road And Building Department-RBD has published Construction Of 30 Bed Ladies Hostel At Skill Development Centre Sdec At Govt. Polyechnic Campus At Dhenkanal For The Year 2022-23. Submission Date for this Tender is 27-09-2022. Vocational Training Tenders in dhenkanal Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation of foundation trenches in all kind of soil including moorum, stoney earth and earth mixed with boulders except sheet rocks and boulders requiring blasting including dressing and leveling the bed up to the required depth and depositing the excavated materials with all leads and lifts T & P shoring & Shuttering if required etc. complete as directed by the Engineer – in – Charge. |
2 | Supplying filling in foundation and plinth with sand in layers not exceeding 150mm thick including watering, ramming including cost, conveyance, royaltyof all materials, all labour T&P required for the work etc. complete (measurement will be taken on finished compacted section only). |
3 | Cement concrete of propertion (1:4:8) in foundation and floors using 40mm size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royaltyof all materials and alllabour T&P required for the work etc. complete as per direction of the Engineer-in-charge. |
4 | Cement concrete of propertion (1:2:4) in foundation and floors using 40mm size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royaltyof all materials and alllabour T&P required for the work etc. complete as per direction of the Engineer-in-charge. |
5 | Fly Ash brick masonary using Fly Ash brick having crushing strength not less than 75kg/cm2 in cement mortar of (1:6) after immersing the bricks for six hours in water before use in Foundation & Plinth including splays cutting circular moulding corbelling champhering and similar such type of work watering and curing including cost conveyance royaltyof all materials and cost of all labour with T&P required for the work etc. complete as per direction of the Engineer – in – Charge. |
6 | RCC work of M-20 in column, beams, roof slab,Sloped Roof Slab,Stair Case, lintel and chajja, fins, shelves and floors slab in all floors having a minimum compressive strength ( in work test) 200kg/cm2 in 15cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 10mm size to 20mm size black hard crusher broken granite stone chips (10mm size 40% & 20mm size 60%) of approved quality & from approved quarry including hoisting lowering laying and compacting concrete with centering & shuttering and finishing the exposed surface smooth providinggrooves or beads where necessary and providing required No. of fan hooks as required including cost, conveyance, royaltiesof all materials and cost of all labour with T&P required for the work etc. complete in all respect but excluding cost of MS rod / Tor steel and binding wire and labour charges for bending binding and tying the grills.(In all Floors) |
7 | Column base & footing |
8 | Plinth beam |
9 | Column & Roof Beam (Ground Floor) |
10 | Column & Roof Beam (First Floor) |
11 | Lintel Bend (Ground Floor) |
12 | Chhaja (6.50cm average thick) G.F. |
13 | Roof slab (Ground Floor) |
14 | Roof slab (First Floor) |
15 | Shelves G.F. |
16 | Stair case G.F. |
17 | Labour charges for straightening the coiled or bend up M.S. rod / HYSD bars confirming to Gr. S 240 or Fe-500, cutting bending binding lapping placing welding etc. (Confirming to ISI specification) and jointing if necessary by lapping and tying the grills and placing in position as required for RCC work as per approved design hoisting lowering and laying in position including cost conveyance & taxes of M.S. rod / tor steel(Primary Producer like-SAIL/RINL/ TATA/ JINDAL STEEL/ SHYAM STEEL) make) and binding wire of 18 to 20 gauge (as approved by the deptt.) weight of over lapping, couping, welded joints, spaeer bar, chair, stage, hanger andbinding wires shall not be considered for payment at all. Standard co-efficient of different size of the steel shall be considered. Welding & lapping should be confirming to relevant clause of IRC 1987 in Ground floor. |
18 | First Floor |
19 | Fly Ash brick masonary using Fly Ash brick having crushing strength not less than 75kg/cm2 in cement mortar of (1:6) after immersing the bricks for six hours in water before use in superstructure including splays cutting circular moulding corbelling champhering and similar such type of work watering and curing including cost conveyance royalty taxes of all materials and cost of all labour with T&P required for the work etc. complete as per direction of the Engineer – in – Charge. (Ground Floor) |
20 | First Floor |
21 | Supplying fixing and fittings MS window grills, MS verandha grills,MS grill gate and MS door shutters with frames of approved design and drawing made out of MS flat and MS angle at work site with one coat of anticorrosive red oxide zink chrome primer including cutting holes in brick or RCC walls and fixing with CC (1:3:6) including cost conveyance royalty and taxes of all materials all labour T&P required for the work complete (payment will be made on weight basis only) |
22 | MS door shutters |
23 | MS window |
24 | MS Grill |
25 | Supplying, fitting, fixing of Vitrified Tiles Premium grade (600x600mm, Colour/Printed) in floors, treads, steps and landing slab on 20mm thick bed of cement mortar (1:4) joined with neat cement slurry mixed with pigments to match the shades of the tiles including, rubbing and polishing the surface with cost, conveyance androyality of all materials etc. complete as per direction of the Engineer-in-charge. (Ground Floor) |
26 | Supplying, fitting, fixing of Vitrified tiles Premium grade (600x600mm) in dados on 12mm thick bed of cement mortar (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including, rubbing and polishing the surface with cost, conveyance and royalityof all materials etc. complete as directed by the Engineer – in – Charge. (Ground Floor) |
27 | Providing 16mm thick cement plaster in cement mortar (1:6)finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. (Ground Floor) |
28 | First Floor |
29 | Providing 12mm thick cement plaster in cement mortar (1:6)finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. (Ground Floor) |
30 | First Floor |
31 | Providing 6mm thick cement plaster in cement mortar (1:4)finished smooth inRCC surface, ceiling & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. (Ground Floor) |
32 | First Floor |
33 | Painting One coat with wall cement Primer (Water Base)by means of brush to outside surface of walls complete in all floors with cost, carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer – in – Charge. |
34 | First Floor |
35 | Painting 2 coats with Distemper of approved shade by means of brush to inside surface of walls after cleaning the surface etc. complete in all floors including cost of all materials with all taxes and cost of all labour with T&P required for the work etc. complete in all respect as directed by Engineer – in – Charge. (Ground Floor) |
36 | First Floor |
37 | Painting 2 coats with water proofing weather coat over a coat of priming of approved shade by means of brush to outside surface of walls with cost, carriage of all materials and cost of all labour with T&P required for the work etc. complete as per direction of the Engineer – in – Charge.(Ground Floor) |
38 | First Floor |
39 | Painting two coats with synthetic enamel paint over a coat of primer to wood/iron work including cleaning the surface with sand papering and using paints of approvedquality and approved shade including cost conveyance of all materials labourT&P etc. complete as directed by the Engineer in charge. (Ground Floor) |
40 | First Floor |
41 | Supplying, fitting, fixing upAluminium ventilatot (fixed type) made up aluminum Section 9778, as windows frame section No. 4095, 4096 and 9777, 3994 as shutter frame with 12 mm thick pre-laminated particle board as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-in-charge. (Aluminium Frame only) |
42 | Providing fitting, fixing of5mm thick Frosted Glass fixed onwindows frame (Fixed Type) by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1855 including all cost of labour, T&P , hire charges of drilling machine, labour charges etc. complete as per direction of the Engineer-in-charge. |
43 | Providing 25 mm thick Grading concrete(1:2:2) using 6.7mm size chips for finished smooth on roof slab etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. (Ground Floor) |
44 | First Floor |
45 | Filling in foundation and plinth with excavated earth including laying in layers not exceeding 23cm.(9”) thick including wellwatered & rammed with all labour T&P required for the work etc. complete. |
46 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 6Amp, 250V Modular switch ISI marked and ceiling rose ISI marked mounted on metal box having front Modular cover of suitable size, metal box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection.(Make of wire-Anchor/Havells/Finolex ) (Make of switch - Legrand /Roma) |
47 | -do- light pointGroup-A |
48 | -do- light pointGroup-B |
49 | -do- light pointGroup-C |
50 | Fanpoint &S. LED lightGroup-B |
51 | Group-C |
52 | -do- EX Fan pointGroup-C |
53 | -do- Call BellpointGroup-C |
54 | Pointwiring to 5A /6Amp socket outlet with 2 X 1.5sq.mm FR PVCinsulated single core multistrand copper conductor of ISI marked in recess 20mm dia non-metallic PVC flexible conduit with piano type switch, Phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 X 1.5sq.mm FR PVC insulated single core multistrand copper conductor forloop earthing etc. as required (Make of wire -Finolex/ Anchor/ Havells/V-Guard)( Make of switch - Roma /Legrand ) |
55 | Separate point- |
56 | S/F of 5 Amp plug with switch on existing board (Modular Type ) (Roma/Legrand) |
57 | Supply and fixing of Modularmetal box on surface or in recess with suitable size of Modular coverin front including providing and fixing of 6pin 6Amp& 16Amp socket outlet and16Amp Modular switches connection(Make- Legrand /Roma) |
58 | Recessed wiring to submain of the following FR PVC insulated single core multistrand copper conductor of ISI Marked confirming to IS-694/1990 in 20mm dia nonmetalic heavy duty flexible conduct 1.6 sqmm thick along with following sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Havells/Finolex/Anhor.) |
59 | 2x1.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
60 | 2x2.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
61 | 2x4 sq mm+1x1.5 sqmm1100 Volts confirming to IS 694/1990 |
62 | 2x6 sq mm+1x2.5 sqmm1100 Volts confirming to IS 694/1990 in 25 mm dia non-metalic heavy duty flexible conduit |
63 | For Inverter wiring 1 X 1.5sqmm |
64 | Supply and fixing of superior type Ding Dong call bell / buzzer of ISI marked, on 6" X4" conforming to IS-2268/1994 and bell push of ISI marked , conforming to IS-1293/1988 (make-Cona/Anchor) |
65 | S/F of StandardEarthing with medium class 40mm 3Mtr. Long ISI markedGI Earth pipe including accessories such as funnel GI nut, Bolt, washer , hinged cover plate with looking arrangement, 40mm to 20GI rediusor 5nos 20mm dia holes on GI pipe required charpol salt, Excavation of earth brick work in cement mortar complete in all respect as per specification of SR 2011 and asper Direction of Engineer-in -Charge. |
66 | S/F of Copper Plate Earthing (600x600x3mm)with running Copper Flat25x5mm from coper plate to funel of 40mm dia GI PIPE heavy duty withincluding all accessories, excavation of earth and providing masonary work with cover plate having loccking arangement and and , charcoal, salt , funnel , tinned brass bolt, check nut and washer complete in all respect as per Govt. schedule of rate 2011 specification as per Direction of Engineering -in-Charge. |
67 | proving and fixing of 8 SWG(4mm) dia copper wire on surface or in recess for loop earthing along with existing surface /reccessed conduit /submain wiring /cable as required |
68 | S/F of Bakelite Angle holder/Batten Holder of ISI marked in place of ceiling Rose completein all respect as per direction of Engineer in charge (Make : Cona / Anchor / Havells). |
69 | S/F of 1x18 watt T5 fitting with all acessories in complete (Havells/Philips/Crompton ) in direction of Engineer in charge |
70 | S/F. of15Wt. LED Surface mounting down lights of( MAKE- Havels/phillips/Crompton ) |
71 | S/Fof 9W LED Bulb (Havells/Philips/Crompton) |
72 | Bulkhead fitting-ENDURA RUGBY Energy saving new geration 10W LED IP65 bulkhead luminaire with opal diffuser 10WLED6000K(Philips/Havells) |
73 | S/F ofStreet light of72 Wattnew generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover.(Phillips/Havells,Crompton) |
74 | S/F of A.C Ceiling fan 48" size. (Make-Usha-Polycab Vital /crompton decora/ Crompton jura.) |
75 | S/F of step type ModularFan Regulator with all connection completein all respect as per direction of Engineer in charge(Make-Roma/Legrand) |
76 | S/F of 12 inchHeavy duty (Metalic Colour)Exahust Fan with wall cutting,plastring, paintingwith all connection complete in all respect as per direction of Engineer- in- charge. (Usha maxx aor dew white /CG TRANS Air /Havels-venti air DS/Orient -air flow)) |
77 | Wall mounted Fan 16" size (make-Havels/Usha/Almonard) |
78 | Providing and fixing of following capacity DPMCBswitch unit inside the existing mcb distribution boxincluding drilling holes in the boxmaking connections, etc as required ( MAKE-Legrand/Seimens/schneider/L & T) |
79 | 63/40AmpDP MCB |
80 | supply and fixing of 5 to 32 amp rating 240 volt c series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with comnnections testing and commisioning as required .( MAKE-Legrand/Seimens/schneider/L & T) |
81 | Single pole |
82 | supply and fixing of single pole mcb with sheet steel enclosure ,distribution board ,on surface /recess,complete with tinned copper bus bar ,neutral bus bar ,earth bar ,din bar ,dertachable gland plate ,interconnection .phosphate and powder painted including including earthing ect. as required ( but with out MCB/RCCB/ISLOATOR )( MAKE-Legrand/Seimens/schneider/L & T) |
83 | 8 WAY,DOUBLE DOOR |
84 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( MAKE-Legrand/Seimens/schneider) |
85 | 4 way (4+12) double door horizontal type |
86 | 63 Amp TPN Mcb |
87 | Supply of 253 1/2Core 1.1KV Grade ISI MarkedAlluminium Armoured Cable (Make-Polycab/Gloster/Nicco) |
88 | Supply and laying of DURGA -GUARD WALL CORRUGATED (DWC) HDPE of size 63mm including transportation |
89 | Trenching with sand spreading and bricks laying and laying of cable in trench in 21/2" depth PVC cable . |
90 | Supply of 2250VA Inverteras per direction of Engineer-incharge (Make-Microtek/Luminious/Exide) |
91 | Supply of tubular 12 volt. 150AH Battery complete with all accessories as per direction of Engineer-incharge( 48 month warrenty )(Make-Microtek/Luminious/Exide) |
92 | Supply Trolly for Inverter and Battery |
93 | Installation charges of Inverter |
94 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. |
95 | 20mm dia C - PVC pipe |
96 | Ground Floor |
97 | 25mm dia C - PVC pipe |
98 | Ground Floor |
99 | 32mm dia PVC ASTM pipe (sch-80) |
100 | Ground Floor |
101 | 40mm dia PVC ASTM pipe (sch-80) |
102 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materialsincluding cost & conveyance of all materials to worksite, payment oftaxes etc. allcomplete as per P.H specification and direction of the Engineer-in-charge. |
103 | 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
104 | 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
105 | 15 mm dia CP L.B. Bib cock(CON-CHR-107KN) |
106 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
107 | 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
108 | 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
109 | 32mm dia brassfull way valve (Shakti make) |
110 | 40mm dia BFW Valve (Shakti make) |
111 | 15mm CP Extension piece |
112 | 125mm CP grating |
113 | 15mm size C.P. flange |
114 | Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthKBbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction ofEngineer-in-charge |
115 | 2000 liters capacityPVC water storage tank (roof of 1stfloor) |
116 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite,payment of royality, taxes etc. all complete as perdirection ofEngineer-in-charge. |
117 | Ground Floor |
118 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proofas per P.H. specification and direction of Engineer-in-charge |
119 | Ground Floor |
120 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damagesincluding watering ,curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
121 | Ground Floor |
122 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment oftaxes etc.all complete as per P.H specification and direction of the Engineer-in-charge. |
123 | 110mm U-PVC SWR Pipe (Ashirvad/Supreme) |
124 | 110mm U-PVC‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
125 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
126 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
127 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
128 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
129 | 110mm U-PVC HR Bend(Ori Plast/Finolex/Supreme Make) |
130 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
131 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
132 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
133 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI "p" or "s" trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
134 | 580mm size Orissa pan (Hindware/Parryware/Neycer make) |
135 | EWC With Seate Cover(Hindware/Parryware/Neycer make) |
136 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge |
137 | 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
138 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge |
139 | 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Jaquar make) with Pedestal |
140 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink |
141 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
142 | 25mmx600mm long CP towel rail |
143 | Towel ring |
144 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. |
145 | 600mmx125mm plate glass shelf with CP/NP guard rails. |
146 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. |
147 | 600mmx450mm size B.E mirror (swivelled type) |
148 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
149 | CP soap holder |
150 | Supplying all materials , labour, T&P and cutting holes through existing brickor laterite masonry wall for takingU-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
151 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. |
152 | ½” x 5” CP Shower (Plaza Deluxe Make) |
153 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber ofinside size 760mmx760mmx460mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed ,Fly Ashbrick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge |
154 | Inside size 76cmx76cmx46cm with 18” dia RCC MH cover |
155 | Supplying all materials ,labour ,T&P and constructing gully trap chamber ofinside size 250mmx250mmwith 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinthand inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI gratingetc.all complete as per drawing,specification and direction of Engineer-in-charge |
156 | Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. |
157 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
158 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tilesincludingwatering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed seriesto be pre-approved by the Engineer-in-charge ) |
159 | Kajaria/Somany/Johnson tile 60cmx60cm (Ground Floor) |
160 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
161 | Ground Floor |
162 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirtingon 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tilesincludingwatering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge ) |
163 | Kajaria/Somany/Johnson tile 60cmx30cm (Ground Floor) |
164 | Supplying, fitting & fixing of Aluminium door with anodized AL door section of 9202 as vertical member, 9201 as top and 9200 as middle bottom member with frame section No 9221 and tappered clip no 4660 and the frame to be completed by means of jointing angle no 1855 including all cost of labour T&P hire charges of drilling machine etc. complete as per direction of the Engineer-in-Charge. |
165 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 120 liter"s along with 3 noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge |
166 | Aqua guard pure Chill 120 PSS UV |
167 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture"s specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge |
168 | 110mm dia P.V.C. pipe |
169 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. |
170 | MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) |
171 | Supplying all materials labour T&P and constructing deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
172 | constructing 1.40m dia x 2.00 m deep soak way pit |
173 | Construction of 1no production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories |
174 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
175 | Drilling of 200mm dia bore |
176 | 00 mtr to 30mtr |
177 | 30 mtr to 45mtr |
178 | Drilling of 150mm dia bore |
179 | 45 mtr to above |
180 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
181 | Lowering of 200mm dia P.V.C casing pipes |
182 | 00 mtr to 30 mtrs |
183 | 30 mtr to 60mtr |
184 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber "O" ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. |
185 | 200mm dia PVC (sch-80) pipe |
186 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
187 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
188 | By DTH Rig |
189 | Supplying all materials , labour T&P and providing consturction of plat form as per UNICEF specifcation etc.all completes as per direction of Engineer-in-Charge |
190 | Supplying all materials ,labour T&P and providingfitting and fixing India Mark-II hand pump with C I Cylender and connectiong roads with providing 24.00 mtr of 32 mm dia GI raiser pipe etc. all complete as perP.H Specification and direction of Engineer-in-Charge |
191 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) |
192 | 1 H.P. Single phase/ three phase 3 stagehead renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
193 | DOL Control panel |
194 | 40mm dia steel short piece |
195 | Well cap |
196 | 50mm size CI bracket |
197 | 2.50sqmm flat cable |
198 | 20mm dia rigid UPVC pipes |
199 | Steel rope with cover |
200 | Labour charges for lowering including transportation |
201 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge |
202 | 32mm HDPE pipes (Finolex/Supreme make) |