Wiring As Item 1 Unpriced Boq But For One Light / Exhaust / Ceiling Fan Point Contr Wiring As Item 1 Unpriced Boq But For One Light / Exhaust / Ceiling Fan Point Controlled By One 6 Amp. Modular Type Switch Completes As Directed. ( Class Iii- 19 Per Flat, Class Iv-16 Per Flat ) . 2 2 Wiring As Per 1.0 But For Calling Bell Point Complete Wiring As Per 1.0 But For Calling Bell Point Complete With Approved Make Bell, Modular Bell Push Etc As Per Standard. ( Class Iii- 1 Per Flat, Class Iv- 1 Per Flat ) . 3 3 Wiring As Per Item No.1.0 But For 6A Independent Switch Wiring As Per Item No.1.0 But For 6A Independent Switch & Socket Complete As Per Standard With Modular Type Switch, Socket Etc As Directed. Separate Switch Box Shall Be Provided For Kitchen Wall Mounted Fan Point In Each Flat ( Class Iii- 10 Per Flat, Class Iv- 8 Per Flat ) . 4 4 Wiring As Per Item No 1 But 2X2.5 Sq Mm + 1X1.5 Sq Mm Copper Conductor Pvc Wiring As Per Item No 1 But 2X2.5 Sq Mm + 1X1.5 Sq Mm Copper Conductor Pvc Insulated Frls Wire With One Set Of 2 Nos. 6A Modular Type Switch 2No . 2 / 3 Pin Socket For Tv / Computer Point In Hall And Bed Rooms Looped From Near By Switch Board. ( Circuit Directly From The Db ) ( Class Iii- 3 Per Flat, Class Iv- 2 Per Flat ) . 5 5 Wiring Same As Above For 6 Amp Switch & Socket Point� Wiring Same As Above For 6 Amp Switch & Socket Point�But On Switch Board. ( Half Point ) ( Class Iii- 11 Per Flat, Class Iv- 9 Per Flat ) . 6 6 Wiring As Per Item No.1.0 But 2X4.0 Sq.Mm + 1X2.5Sqmm Copper Wiring As Per Item No.1.0 But 2X4.0 Sq.Mm + 1X2.5Sqmm Copper Conductor Pvc Insulated Frls Wire With 25A Modular Type Mcb Switch Socket For Ac Point, Wiring Directly From Main Db. ( Class Iii- 2 Per Flat, Class Iv- 1 Per Flat ) . 7 7 Wiring�As Per Item No. 1.0 For 16 A Modular Type Socket ( Geyser Point ) Wiring�As Per Item No. 1.0 For 16 A Modular Type Socket ( Geyser Point ) To Be Installed As Directed But With 2 X 2.5 Sq. Mm.+ 1X1.5 Sqmm Copper Conductor Frls Pvc Insulated Multi Strand Copper Wire Controlled By 16 A Modular Switch With Indicator Outside Bathroom. ( Circuit Directly From The Db ) ( Class Iii- 1 Per Flat, Class Iv- 1 Per Flat ) . 8 8 Wiring As Per Item No.1.0 But For Power Point Using 2X2.5 Sqmm + 1X1.5Sqmm Wiring As Per Item No.1.0 But For Power Point Using 2X2.5 Sqmm + 1X1.5Sqmm Frls Pvc Insulated Multi Strand Copper Wire With 6 Pin 16A Socket With16 A Switches With Indicator Housed In Concealed Manner Complete As Directed. ( Circuit Directly From The Db ) ( Class Iii- 2 Per Flat, Class Iv- 2 Per Flat ) . 9 9 Wiring As Per Item No.1 With 2X2.5 Sq. Mm. 1X1.5 Sq. Mm. Wiring As Per Item No.1 With 2X2.5 Sq. Mm. 1X1.5 Sq. Mm. Copper Conductor Pvc Insulated Frls Wire With One Set Of 1 No. 16A Modular Type Switch And 1 No. 2 / 3 Pin 16A Socket For Kitchen, Wiring Looped From Nearby Power Point. ( Secondary Point ) ( Class Iii- 1 Per Flat, Class Iv- 1 Per Flat ) . 10 10 Wiring As Per Item No.1.0 But For Power Point Wiring As Per Item No.1.0 But For Power Point Using 2X2.5Sqmm + 1X1.5Sqmm Frls Pvc Insulated Multi Strand Copper Wire With 6 Pin 16A Socket With16 A Switches With Indicator Housed In Concealed Manner For Washing Machine Point Complete As Directed. ( Circuit Directly From The Db ) ( Class Iii- 1 Per Flat, Class Iv- 1 Per Flat ) . 11 11 Supply And Fixing Of Step Type Modular Electronic Regulators Supply And Fixing Of Step Type Modular Electronic Regulators ( 2 Module Size ) For Ceiling Fans On The Switch Boards ( Class Iii- 3 Per Flat, Class Iv- 2 Per Flat ) . 12 12 Supply & Providing Wiring For Tv Cable Point Supply & Providing Wiring For Tv Cable Point By Providing Suitable Junction Box ( 4X4 Metal Box Concealed In Wall With Cover ) Near Main Entrance / As Directed And Wiring For Hall And One Bedroom Independently With Rg-6 Co-Axial Cable In Suitable Dia Pvc Conduit As Described In Item 1.0. The Rate Shall Include For Providing Modular Tv Sockets With Respective Make, Required Size Mounting Plate Fixed On M.S. Box Concealed In Wall, Termination Of The Tv Cable At Both Ends. ( Class Iii- 2 Per Flat, Class Iv- 2 Per Flat ) . 13 13 Supply & Providing Wiring For Telephone Point Supply & Providing Wiring For Telephone Point By Providing Suitable Junction Box ( 4X4 Metal Box Concealed In Wall With Cover ) In The Existing Incoming Telephone Line And With Two Pair 0.5 Sqmm. Dia Copper Conductor Pvc Insulated Telephone Wire In Suitable Dia Pvc Conduit As Described In Item 1.0.�The Rate Shall Include For Providing Modular Telephone Sockets With Respective Make, Required Size Mounting Plate Fixed On M.S. Box Concealed In Wall, Termination Of The Wire At Both Ends. ( Class Iii- 1 Per Flat, Class Iv- 1 Per Flat ) . 14 14 Wiring Same As Above But Looping From Above Telephone Point Wiring Same As Above But Looping From Above Telephone Point In Hall To Bedroom Using Two Pair Telephone Wire ( Parallel Connection ) ( Class Iii- 2 Per Flat, Class Iv- 1 Per Flat ) . 15 15 Supply, Assembly, Installation, Testing And Commissioning Of Fancy / Bracket Supply, Assembly, Installation, Testing And Commissioning Of Fancy / Bracket Fittings ( Phillips / Crompton / Havells Make ) As Approved By The Bank?S Engineer Using Required Hardware With Required Copper Conductor Flexible Wire. ( Class Iii- 3 Per Flat, Class Iv- 2 Per Flat ) . 16 16 Supply, Assembly, Installation, Testing And Commissioning Of 1200 Mm Sweep Supply, Assembly, Installation, Testing And Commissioning Of 1200 Mm Sweep Brown Colour High Speed Ceiling Fans With Required Copper Conductor Flexible Wire And New Highest-Grade Fan Rods As Directed. ( Class Iii- 1 Per Flat, Class Iv- 1 Per Flat ) . 17 17 150Mm Modular Type Exhaust Fans With Louvers ( Toilet ) 150Mm Modular Type Exhaust Fans With Louvers ( Toilet ) 18 18 200Mm Modular Type Exhaust Fans With Louvers ( Kitchen And Bathroom ) 200Mm Modular Type Exhaust Fans With Louvers ( Kitchen And Bathroom ) 19 19 Supply And Installation Of 24W, 4 Feet Led Tube Light Including Connection Supply And Installation Of 24W, 4 Feet Led Tube Light Including Connection With Flexible Wire As Per Standard. ( Class Iii- 4 Per Flat, Class Iv- 3 Per Flat ) . 20 20 Supply And Installation Of 10W, 2 Feet Led Tubelight Including Connection Supply And Installation Of 10W, 2 Feet Led Tubelight Including Connection With Flexible Wire As Per Standard. ( Class Iii- 1 Per Flat, Class Iv- 1 Per Flat ) . 21 21 Supply And Installation Of 9W Led Bulb ( B-22 Holder ) Supply And Installation Of 9W Led Bulb ( B-22 Holder ) With Necessary Pvc Modular Type Angle Holder As Per Standard. ( Class Iii- 2 Per Flat, Class Iv- 2 Per Flat ) . 22 22 Supply, Installation Of 9W Surface Led Fitting Supply, Installation Of 9W Surface Led Fitting Including Connection With Flexible Wire As Per Standard. ( Class Iii- 2 Per Flat, Class Iv- 2 Per Flat ) . 23 23 Supply And Laying Of 2X6 Sq Mm + 1X4 Sq Mm Frls Supply And Laying Of 2X6 Sq Mm + 1X4 Sq Mm Frls Pvc Insulated Multi Strand Copper Wire As Specified In Item 1.0 Through Conduit And Existing Cable Route As Per Standard And As Directed. 24 24 Supply, Installation, Testing And Commissioning Of Vertical Type 12-Way Supply, Installation, Testing And Commissioning Of Vertical Type 12-Way Single Phase Mcb Db Double Door Factory Fabricated, Ip 43 Protection In Concealed Manner Complete With Loop Connections, Neutral, Earthing, Etc. Comprising Of Following Components, Complete As Directed. 40 A Rccb With 30Ma Sensitivity. 20A Sp Mcb? 1 Nos. 16A Sp Mcb? 1 Nos. 10A Sp Mcb ? 1 Nos. Existing Dp Incomer And Sp Mcbs To Be Reused. Blank Plate Should Be Provided Wherever Required To Avoid Gaps, If Any. 25 25 Buy Back Removal Of Old Wiring, Dbs, Switch Boards, Light Fittings And Taking Away As Buyback Excluding Mcbs, Led Fittings / Bulbs, Fans And Exhaust Fans.