Special MAINTENANCE Of Gajaria L.I Schemes Under Bishalgarh R.D Block During The Year 2022-23 / Mtc. Of Pump Motor, Electrical Equipment, Gi Suction Line, Panel Board, Distribution Line Etc. Under W.R Sub-Division Bishalgarh, West Tripura-Tripura

Public Works Department-PWD has published Special MAINTENANCE Of Gajaria L.I Schemes Under Bishalgarh R.D Block During The Year 2022-23 / Mtc. Of Pump Motor, Electrical Equipment, Gi Suction Line, Panel Board, Distribution Line Etc. Under W.R Sub-Division Bishalgarh. Submission Date for this Tender is 29-09-2022. Lift Irrigation Tenders in West Tripura Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

33945962
Special MAINTENANCE Of Gajaria L.I Schemes Under Bishalgarh R.D Block During The Year 2022-23 / Mtc. Of Pump Motor, Electrical Equipment, Gi Suction Line, Panel Board, Distribution Line Etc. Under W.R Sub-Division Bishalgarh
Open Tender
Indian
Tripura
West Tripura
29-09-2022

Tender Details

Special MAINTENANCE Of Gajaria L.I Schemes Under Bishalgarh R.D Block During The Year 2022-23 / Mtc. Of Pump Motor, Electrical Equipment, Gi Suction Line, Panel Board, Distribution Line Etc. Under W.R Sub-Division Bishalgarh

Key Value

Document Fees
INR 1000 /-
EMD
INR 10564.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Special Mtc. Of Gajaria L.I Schemes under Bishalgarh R.D Block during the year 2022-23/ Mtc. Of pump motor, electrical equipment, GI suction line, panel board, distribution line etc. under W.R Sub-Division Bishalgarh.
Sl. No. Item Description
1Complete re-winding of 400/400 volt AC3 phase horizental motor of different make after taking out of entire burnt copper wire & rewinding the motor with proper gauge of supper enamel coper wire of approved quallity, tapping, insulting, varnishing with vernish hating polissing & re-fitting fixing the same as before in/c carriage the motor from respective scheme & back complate with trial run as per direction of the engg-in-charge 3.38.1 20 HP
23.38.2 25 HP
3Supplying & fitting fixing of ball bearing of approved quality (TATA/SKF MAKE) for motor. 3.41.2 6309 Ball bearing (TATA /SKF)
43.41.3 6310 Ball bearing (TATA /SKF)
5Dismantalling of pump for over hauling in/c grearing , gland packing necessary repairs and reinstallation of the same in/c trial run for 10 hrs in two spell complete as per direction of engg-in-charge
6Providing & fiting fixing C.I coupling of appoved quality 3.2.1 150 mmf
73.2.3 225 mmf
8Providing & fiting fixing Shaft sleve of appoved quality 3.7.1 Cast iron (CI)
9Providing & fiting fixing Cashing ring of appoved quality
10Providing & fiting fixing lantern ring for pump of appoved quality
11Providing & fiting fixing C.I gland of appoved quality
12Providing & fiting fixing Coupling nuts & Volts(All size)of appoved quality
13Providing & fiting fixing Sheft sleve nut of appoved quality. 3.8.1 Cast Iron (CI)
14Supplying & fitting fixing ball bearingof approved quality for pump 3.15.1 6305 Ball bearing (TATA /SKF)
153.15.2 6306 Ball bearing (TATA /SKF)
16Providing &fitting fixingM.S hose clamp with nuts & bolts etc. complete at site of work of approved quality 3.19.1 150 mm dia
17Providing &fitting fixing PVC suction hose pipe over all thickness 5 mm best quality at site of work (Pankaj by made)of approved quality 3.20.1 150 mm dia
18Providing &fitting fixing C.I tail piece of approved quality at site of work. 3.22.1 150 mm dia
19Providing &fitting fixing C.I foot valve of heavy duty of at site of work of approved quality 3.23.1 150 mm dia
20Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality. 3.67.1 SMI-144, Range 0-400 to 0-500
21Supply & fitting fixing AC Ammeter(moving iron) on the pannel board of approved quality 3.68.1 SMI-144, Range 0-10A
22Providing & fitting fixing steel sheet enclosed switch . Fuse unit (suitable for DIN fuses ) triple pole with netural link (TPN), 415/500 volt complete as per direction of the engg-in-charge. 3.64.1 Current range 63 Amps.
233.64.3 Current range 200 Amps.
24Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality.
25Providing & fitting fixing 7/16 Coper wire with all electrical equipments in/cl trail run etc. complete (ISI marked) on the pannel board of approved quality.
26Supply & fitting fixing manually operated oil immerged starter of approved quality. a) 30HP Osco/BCH make
27Dismental of pannel board as per direction of the Engineer-in-charge.
28Providing & fitting fixing of pannel board of local teak wood for fitting & fixing of electrical items including 2 nos. MS angle post ( Size 50X50X6mm 2.80 Mtr. long) nuts& bolts etc. for errection of the same by 1 : 1.5 : 3 cement concreate casting (1feetX1feetX2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engineer-in-Charge. 3.61.1 Size 1.80X1.20X0.025 mtr
29Labour charge for reinstallation of all electrical equipments (dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely) on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge.
30Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in - charge. v. 40 mm dia
31Providing and fixing MS bolts including nuts and washers complete as per standard design:- Upto 300mm length.
32Excavating trenches of required width for pipes, cables, etc. including excavation for sockets and dressing of sides ramming of bottoms , depth minimum 1.25m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavated soil as directed within a lead of 50 m as per CPWD Specification & direction of Engineer-in-charge. A) All kinds of soil. a) Pipe , cables etc. exceeding 75mm dia but not exceeding 160 mm dia .
33b) Pipe , cables etc. exceeding 200 mm dia but not exceeding 315 mm dia
34Providing and fitting fixing rigid UPVC Reducing socket (one size lower at one end, both end socketted) suitable for pipes of Working pressure 2.5/4.0 kg/sq.cm. as per CPWD Specification & direction of Engineer-in-charge. 1.3.1 315x250 mm dia
351.3.2 250x200 mm dia
361.3.3 200x160 mm dia
371.3.4 160x140 mm dia
381.3.5 140x110 mm dia
391.3.6 110x90 mm dia
40Providing & fitting fixing rigid UPVC bend(30 degree,45 degree,60 degree, 90 degree) for UPVC pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm as per CPWD Specification & direction of Engineer-in-charge. 1.4.4 160 mm dia
411.4.5 140 mm dia
421.4.6 110 mm dia
431.4.7 90 mm dia
44Providing and fitting fixing of G.I hydrant suitable for PVC pipes as per standard specification complete as per direction of Engineer incharge (Rate excluding the cost of NTP control valve). 80X50 mm dia.
45Providing and laying different dia rigid UPVC pipes of Working Pressure 2.5 kg/4.0 kg/ sq.cm. complete with necessary coupler and solvent cement as per CPWD Specification & direction of Engineerin- charge. 1.10.1 90 mm dia
461.10.2 110 mm dia
471.10.4 160 mm dia
481.10.6 250 mm dia
49Providing and fitting fixing of M.S shore manifold made with 3mm thick MS sheet of size one way 315 mm dia & three way 125 mm dia made with suitable flange(all end) including coating with sheet primer(tailpiece if required will be paid separately) including proper alignment with pipe line & earth cutting ,backfilling complete as per direction of Engineer-in-charge.
50Labour charge for repairing of leakage in existing UPVC distribution system including required earth cutting and fitting fixing of necessary coupler etc. complete and refilling the trench with available excavated earth as per direction of the Engineer incharge. (Payment of couplers, tees, reducers etc will be made separately) 1.13.1 315 mm dia to 200 mm dia.
511.13.2 160 mm dia to 90 mm dia.
52Excavating trenches required width for pipes, cables, etc. including excavation for sockets, collars etc and dressing of sides ramming of bottoms , depth minimum 0.90m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavated soil within a lead of 50m ( For G.I and C.I pipes) A) All kinds of soil. i) Pipes, cables etc exceeding 75 mm dia but not exceeding 150 mm dia
53Dismentaling of G.I pipe including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineerin- Charge. 125/150 mm ?
54Dismentaling of G.I bend including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineerin- Charge. 125/150 mm ?
55Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. A. External work. x. 125 mm dia. nominal bore
56xi. 150 mm dia. nominal bore
57Supplying & fitting fixing of GI . bend of approved quality. 3.16.1125 mm dia
58Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality. 3.18.1 150 mm dia
593.18.2 125 mm dia
60Supplying & fitting fixing of rubber flange washer 6mm thick of approved quality as per direction of the Engineer-in-charge 3.46.1 125 mm dia
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail