Housing Urban and Rular Development Government Departments Closing in 0 days TDR #33945067

Civil And Electrical Repair Work In Upper Subordinate Quarters Iii / 3, V / 3, 9, 11, 15, 16 And Lsq 7 / 1 To 7 / 8, 8 / 1 To 8 / 6, 9 / 2 To 8 / 8, 10 / 1 To 10 / 8 And 18 / 1 To 18 / 8

Issued by Government Departments · jaipur, Rajasthan
Tender Value
42.40 Lakhs
Estimated cost
Bid Submission
29 Sep 2022
0 days left
EMD
84800
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Civil And Electrical Repair Work In Upper Subordinate Quarters Iii / 3, V / 3, 9, 11, 15, 16 And Lsq 7 / 1 To 7 / 8, 8 / 1 To 8 / 6, 9 / 2 To 8 / 8, 10 / 1 To 10 / 8 And 18 / 1 To 18 / 8

BOQ

Name of Work : Civil and Electrical repair work in Upper subordinate quarters III/3,V/3,9,11,15,16 and LSQ 7/1 to 7/8,8/1 to 8/6,9/2 TO 8/8,10/1 TO 10/8 And 18/1 to 18/8
Sl. No. Item Description
1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix.
2Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead:Of area 3 square meter and below.
3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar.
4Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
5Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
6Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
7Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 2 in following stepsi) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.ii) Applying Epoxy primer on the exposed steel bars.iii) Applying Epoxy hardener and resin mix (as per manufectured\"s specification) on concrete and steel bars with brush.iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.vi) Cure the plastered surface for 15 days All work including scaffolding etc. complete in all respect.
8Repairofdoor,windowshuttersincludingcostofmaterialandlabourforchangeofdamaged :
9Aldrop of mild Steel 12\" long x12mm dia
10Stopper of Aluminium with Double Rubber Gutka
11Making of hole (width up to 150 mm) in R.C.C. slab/wall/beams by power driven drilling machine complete as per direction of EI upto 150mm thick
12Grading roof for water proofing treatment withwater proffing compoundCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
13Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
14Making khurras 450 x 450mm with average minimum thickness 50mmcement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and onecoat of neat cement, rounding edges and making and finishing the out let complete.
15Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
16Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Partly fixed and partly openable [ fixed area not to exceed 33%]
17Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
18Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
19Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure \"A\":30 mm thick .Commercial Veneer both side
20Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13.
21Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Keseriaji/ Abu Ambaji (Green Marble) Above 3601 Cm2 Slabs
22Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Marble work Full Edge moulding
23Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone workincluding necessaryholesfor pillar taps etc. including rubbing and polishing of cut edges etc. complete
24Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
25Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4)..
26Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed:All kinds of soil
27Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
28Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).
29Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone minimum 30mm thick.
30Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75Cement mortar 1 : 4 (1 cement : 4 coarse sand)
31Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand)
32Providing&fixingprecastcementconcretecoping1: 2 :4mix50mmthickcompleteas per specification :
33Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours.b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours.The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry.
34Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick batscomplete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification.
35P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm.
36Labour charges for removing W.C. pan (any type) of all sizes with care including all necessary fittings P or S trap.
37P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 550 mm x 400 mm
381.0 mm thick stainless steel AISI -304 & IS 13983-1994kitchen sink of approved make as per Engineer-in-chargewith large waste coupling.Overall size (inches)22 x 18 x 7 Bowl size (inches) 20x16x7
39P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:
40C.P. Brass bib cock,15mm nominal bore.
41C.P. Brass Long body, 15mm nominal bore weight not less than 690 gm
42P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked)with 37 cm long pipe and nut.
43P&FFlushCock / FlushValve (IS :9758Mark)forWCofapproved quality make :CP brass push type concealed 25mm nominal bore.
44P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :
45Gun-metal 15mm nominal bore.
46Gun-metal 25 mm nominal bore.
47P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity.
48Hoisting Charges for each floor :For 200 litre to 750 litre capacity
49Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)25 mm nominal outer dia pipes
50Labour Charges for Removing & Refixing the water Storage Tank of all sizes and including all Necessary fitting complete in all respect as per approved sample and direction of engineer in charge.
51Providing Laying & jointing glazed S.W. pipes grade `A` (IS;651 marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1, excavation & refilling of earth in all types of soil upto 1.2m depth, S.W. fittings, including testing of joints etc, complete.150mm dia
52Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) all around S.W. pipe including 15 Cm. thick bed concrete (Width W= Diameter of pipe in Cm+30 Cm.)( Excluding cost of pipe)150mm dia S.W. pipe
53Labour charges for Removing S.W. pipes including breaking of joints & bed concrete, stacking of useful material at site within 50 mtr. Lead and disposal of unserviceable material within 0.5 Km. lead:100 & 150mm dia pipe
54P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.110 mm dia
55P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:
56Coupler (socket)110mm dia
57Bend 87 .5 110mm dia
58Pipe Clip 110mm dia
59Door Tee 110mm dia
60Raising manhole cover and frames slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole masonry to be paid separately).Rectangular manhole 90x60 cm
61Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.
62Depth up to 0.5 M
63Add extra over item 3.19.1 for every additional 0.10m depth above 0.5 m depth.
64Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside sizesize 450 x 450mm depth upto0.5 M Cement cover with frame
65Construction of Cement Concrete Chamber 125mm dia.C.P. Brass grating
66Construction of Cement Concrete Chamber 125mm dia on depressed floor upto 45cm height from floor with :C.P. Brass grating
67Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make
6875 mm dia
69110 mm dia
70Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make
71Coupler
7275mm dia
73110mm dia
74Bend 87.5 Dg.
7575mm dia
76110mm dia
77Double \"Y\" with Door
7875mm dia
79110mm dia
80Pipe Clip
8175mm dia
82110mm dia
83Single Tee with Door
8475mm dia
85110mm dia
86Nahni Trap without Jali 4” 110mm dia
87Vent Cowel 75 mm
88Vent Cowel 110mm dia
89Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :25 mm thick.
90Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :
9125mm thick.
9212mm thick.
93Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete
94New Plastered Surface (three or more coats)
95Old Plastered Surface (two or more coats)
96Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer.
97Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision New Work
98Applying priming coat :With ready mix Aluminium primer of approved brand and manufacture on resinous wood and plywood.
99Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work
100Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvaiumeseel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm shets be casted with regular modified plyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate at made at to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and foe a minimum up to 12mts with all scaffolding.
101Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
102Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed:All kinds of soil
103Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/ park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc.( As per table 1 ofIS 15658:2006Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004
104P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type.Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm.
105Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet\"s &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR
106Short point (up to 3 mtr.)
107Medium point (up to 6 mtr.)
108Long point (up to 10 mtr.)
109Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
110On board
111Long point (up to 10 mtr..)
112Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
113Providing & Fixing of following modular accessories as per PWDspecification for electrical Works, made out of unbreakable and fireretardant vergin poly carbonate with brass terminals and captive screws &silver alloy contact tip with IP-20 rating , including all as per preapprovedby Engineer in charge,making connections, testing etc. as required. Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR
114T.V. coaxial socket
115Supplying and drawing coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor ofalum. alloy braidin existingsurface or recessed conduit/casing capping including making connections as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
116RG - 6
117P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
1181.2 mm thickM. S. Sheet boxes
11975mm x 75mm x 60mm
120Providing & Fixing of ISI marked (IS:2268-1994) gong bell with CM/L no.printed including making connection testing etc. as required. All as per preapproved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR .
121Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy = 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.=0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate/ Report from OEMshall besubmitted. All asper pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
1221170mm(+/-10%) LED batten with min. lumen output 2200 lm
123Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and dinbar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
12412 Way (12+2)
125Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure\"A\" attached with this BSR
126Double pole MCB(With B/C curve tripping Characteristics)
12740 A rating
128Single pole MCB (With B/C curve tripping Characteristics)
1296 A to 32 A rating
130Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure \"A\" attached with this BSR
1312 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
1322 x 2.5 sq. mm. + 1x1.5sqmm
1332 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
134Providing & Fixing of of Double ball bearing, copper wounded capacitorstart single phase metallic blade fresh air fan, in existing openingincluding cost of hardware , flexible 3 core copper conductor ,makingconnections, testing etc. as required. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR
135225 mm sweep
136Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the groundlevel with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessorieslike nut, bolts, reducer, nipple, wire meshed funnel, and Heavy dutyweather proof poly-propylene earth pit chamber with lockable Jam freelid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. andembodying the pipe complete withalternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less asrequired & must record by engineer in charge during site visit and ensureto enter in measurment book.All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR .
137Supply & Laying following size earth wire in horizontal or vertical runinground/surface/recess including riveting, soldering, saddles, makingconnection with GI/Cu purity purity >95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with thisBSR .
1388 SWG G.I. ( Hot Dipped ) Wire
139Providing & Fixing of modular type 120 W Step Fan regulator duly ISImarked (IS 11037:1984 ) with CM/L no. printed made out of unbreakableand fire retardant vergin poly carbonate with brass terminals and captivescrews & silver alloy contact tip with IP-20 rating , including all as per preapproved by Engineer in charge,making connections, testing etc. asrequired. For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
1405 step fan regulator 2 Module 360 dgree rotating

AI Tender Summary

OUR REF NO 33945067
AUTHORITY Government Departments
TENDER VALUE 42.40 Lakhs
LAST DATE 29-09-2022
Authority
Authority Name Rajasthan Police Housing & Construction Corporation Limited
Work Description Civil And Electrical Repair Work In Upper Subordinate Quarters Iii / 3, V / 3, 9, 11, 15, 16 And Lsq 7 / 1 To 7 / 8, 8 / 1 To 8 / 6, 9 / 2 To 8 / 8, 10 / 1 To 10 / 8 And 18 / 1 To 18 / 8
Basic Detail
Tender No NIT No 10 of 2022-23MD, RPIDCL, Jaipur
Bidding Type Tender
Location
City jaipur
State Rajasthan
Key Dates
Publish Date 15 Sep 2022
Submission Date 29 Sep 2022
Open Date 30 Sep 2022
Finance
Tender Value 42.40 Lakhs
Tender Fee 1180
EMD 84800
Exemption Not Available
Document List
Tendernotice_3.pdf
0dc21c94-b4ad-4953-9752-fbcf9d525493.html
BOQ_525223.xls
frontpage.pdf
List_of_approved_make.pdf
Special_Condition.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
Tendernotice_6.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 30, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_3.pdf

html

0dc21c94-b4ad-4953-9752-fbcf9d525493.html

xls

BOQ_525223.xls

pdf

frontpage.pdf

pdf

List_of_approved_make.pdf

pdf

Special_Condition.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

Tendernotice_6.pdf