}

Supply And Fixing Of Decorative Poles In Kamla Nehru Garden At Muniicpal Board Mount Abu Supply And Fixing Of Decorative Poles In Kamla Nehru Garden At Muniicpal Board Mount Abu , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Armoured Al, Sirohi-Rajasthan

Department Of Local Bodies has published Supply And Fixing Of Decorative Poles In Kamla Nehru Garden At Muniicpal Board Mount Abu Supply And Fixing Of Decorative Poles In Kamla Nehru Garden At Muniicpal Board Mount Abu , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Armoured Al. Submission Date for this Tender is 26-09-2022. Couplers Tenders in Sirohi Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

33944981
Supply And Fixing Of Decorative Poles In Kamla Nehru Garden At Muniicpal Board Mount Abu Supply And Fixing Of Decorative Poles In Kamla Nehru Garden At Muniicpal Board Mount Abu , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Armoured Al
Open Tender
Indian
Rajasthan
Sirohi
26-09-2022

Tender Details

Supply And Fixing Of Decorative Poles In Kamla Nehru Garden At Muniicpal Board Mount Abu Supply And Fixing Of Decorative Poles In Kamla Nehru Garden At Muniicpal Board Mount Abu , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- ( A ) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I ( B ) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testing Procedures. ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. 6.0 Sq. Mm4 Core , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection With Gi / Cu Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 10 Swg G.I. ( Hot Dipped ) Wire , Supply & Laying Following Size B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Accessories Like Bend, Socket Etc. For Laying Earth Conductor / Strip / Cable In Ground / Surface / Recess As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 50 Mm Dia , Providing & Laying Of Double Wall Corrugated Pipe Confirming To Is : 14930 P - 1 & 2 With Hdpe Coupler At 1 Mtr. Depth Below The Ground For Laying Cable Including Making The Trench And Back Filling , Compaction Of Earth As Required ( Excavation Of Earth To Be Paid Extra As Required. ) Of Following Outer Dia. / Inner Dia As Per Is:4984:1995. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 55 / 50 Mm , Labour Charges For Excavation Of 30Cmx75cm Size Trench In Cc Road Including Refilling Of Excavated Earth, Compaction Of Earth, Making Good The Same Complete As Required . , Labour Charges For Excavation Of 30Cmx75cm Size Trench In Loose Soil Including Refilling Of Excavated Earth, Compaction Of Earth, Making Good The Same Complete As Required . , Plate Earthing As Per Pwd Specification For Electrical Works As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe , Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke / Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Single Pole Mcb 06 Amp Rating , Four Pole Mcb 32 Amp Rating , Providing & Fixing Of Ac Operated Heavy Duty 230 / 440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is / Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 4 Pole Power Contactors With Following Ac 1 Rating 32 Amp. , Supplying And Fixing Of Aluminium ( Iec 60105 Iso 209-1, 2 ) / Copper ( Iec 60028 ) Bus Bar As Per Pwd Specification For Electrical Works, By Means Of Smc / Dmc Type Insulator, High Tensile Nuts And Bolts Spring Washers In Existing Panel Including Bending , Cutting In Required Shape And Size And Colour Coding With Heat Shrinkable Pvc Sleeves. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Electrolytic Grade ( Cu-Etp ) Tin Coated Annealed Copper Bus Bars Iacs 100% Grade , Sitc Of Wall / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Per Pwd Specification For Electrical Works, Made Out Of Crca Sheet . Other Parameters Required As Per Point ( A ) , ( B ) , ( C ) , ( D ) Below:- ( A ) Thickness Of Sheet Shall Not Be Less Than 1.6 Mm Up To 600 Mm Length / Width Of Any Compartment And Be Of 2.0 Mm Above 600 Mm. Load Bearing Structure Shall Be Of 2.0 Mm Thick Sheet Supported By Base M.S. Channel If Required . Side Walls And Cable Alley Compartments Having Bolted Type Doors With / Without Detachable Extension Type Structure ( B ) Panel Shall Be Duly Treated For Derusting In 7 Tank Process With Dephosphating And With Powder Coating Of Minimum 70 Microns On Both Side Of Panel In Desired Shade The Panel Having Pu / Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness , Required Hardware, Separate Detachable Gland Plate M.S. Base Channel ( Min75mm ) , Hinged Door With Locking Arrangement For Equipment / Switchgear. ( C ) Interconnection Between Bus Bar And Switchgears / Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires ( Up To 125 Amp ) And By Solid Bus Bar ( >125 Amp ) . All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( D ) Only Outer Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator. All As Per Drawing Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Providing & Fixing Of 110 - 240 V, Ac, 1 Ph. , 2 W Astronomical Time Switch With Surge Suppressor, Memory Card, Sunrise / Sunset Selectable, Software For Programming Including Making Connection, Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc / Ms Conduit / Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 2 X 1.5 Sq.Mm , 3 X 2.5 Sq.Mm , 1 X 4.0 Sq.Mm , Providing & Fixing Of Ik07 Ip-66 Protected High Power Led Floodlight System With Pressure Diecast Aluminium Housing Lm6 / Adc12 Material , Toughened Glass Diffuser With Suitable Lenses On Led To Achieve Various Beam Angles, 240 Volt, 50Hz, Of High Power Led Lamps . Integrated Driver Must Be Potted & Has A Unique Bis R Number Shall Be High Efficiency Having Efficiency More Than 85 %And In Compliance To Bis Certified And T.C. Certificate. The System Level Luminaire Efficacy >=120 Lm / Wt With High Power Leds Is To Be Used . Led Driver Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 , Driver Efficiency >85% , Thd ( I ) <10% , Driver Current <1000Ma Shown In Lm79 Report. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Electrical Connector Must Be Provided, Surge Protection Min >=4Kv Internaland 10Kv External, System Life Of 30000 Burning Hours With 70% Ofinitial Lumens Maintained, Color Rendering Index >70 And Cct 5700K±355K. Driver Current <1000Ma Shown In Lm79 Report. Manufactures Word Mark / Name Engraved / Embossing / Screenprinting On Die Cast Housing To Allow Traceability / Authenticity. Fixture Shall Be Is 10322 Complianced. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 / Lm80 ) Certificate / Report Withliable Warranty Of Product / Accessories From Oem Shal Be Submitted.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . High Power Led Flood Light 200W

Key Value

Document Fees
INR 500 /-
EMD
INR 40482.0 /-
Tender Value
INR 20.24 Lakhs /-

BOQ Items

Name of Work:-Supply and fixing of Decorative poles in Kamla Nehru Garden at Municipal Board Mount Ab
Sl. No. Item Description
1Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 6.0 Sq. mm4 core
2Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 10 SWG G.I. ( Hot Dipped ) Wire
3Supply & Laying following size" B " class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 50 mm dia
4Providing & laying of Double wall corrugated pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required( Excavation of Earth to be paid Extra as required. ) of following Outer Dia. / Inner dia as per IS:4984:1995. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 55/50 mm
5Labour charges for Excavation of 30cmx75cm size trench in CC road including refilling of excavated earth,compaction of earth, making good the same complete as required .
6Labour charges for Excavation of 30cmx75cm size trench in loose soil including refilling of excavated earth,compaction of earth, making good the same complete as required .
7Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
8Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Single pole MCB 06 Amp Rating
9Four pole MCB 32 Amp Rating
10Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 4 pole Power contactors with following AC 1 Rating 32 Amp.
11Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade
12SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c), (d) below:- (a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear.(c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
13Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
14Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 2 x 1.5 sq.mm
153 x 2.5 sq.mm
161 x 4.0 sq.mm
17Providing & Fixing of IK07 IP-66 protected high power LED floodlight system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 %and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internaland 10KV external, System life of 30000 Burning hours with 70% ofInitial Lumens maintained, color Rendering Index >70 and CCT 5700K±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report withliable warranty of product/accessories from OEM shal be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . High Power LED Flood Light 200W
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail