| 1 | M&L for checking / inspection of non functional / non working geyser any capacity / make in existing location for identifying the defects/faults in geyser/wiring/fault from DB etc all as per complaint obtained from MES service centre and all as directed.Notes :-(i) Any repair / replacement require to rectify the defects to make geyser serviceable shall be measured and paid separately.(ii) All defects notified shall be recorded in pucca bound register and shall be certified by the Engineer-in-charge.(iii)Contracor shall provide the complaint slip containing 100 pages in duplicate (in single colour) of size 5 inch x 8 inch properly binded and printed with their Firm Name and Telephone numbers as per sample and directed by Engr-in-Charge. |
| 2 | S&F in replacement gun metal check valve / non return valve 15 mm dia suitable for Geyser of any make/capacity complete. |
| 3 | S&F in replacement pressure release valve 15mm dia suitabel for existing geysercomplete. |
| 4 | S&F in replacement geyser heating element 2000 watt suitable for any type, size & make of geyser as per existing including rubber ring, clamping screws etc .Make:- Powerpack/ Dasspass/Theeta |
| 5 | S&F in replacement geyser heating element 1500 watt suitable for any type, size & make of geyser as per existing including rubber ring, clamping screws etc .Make:- Powerpack/ Dasspass/Theeta |
| 6 | S&F in replacementthermostat of geyser suitable for any type, size & make of geyser as per existing range 15-60 degree temperature.Make: Powerpack/ Dasspass/Theeta |
| 7 | S&F in replacement PVC Cable of size 1.50sqmm3 core copper conductor round type. |
| 8 | S&F in replacementindicating lamp round typesuitable for Geyser any type, make & capacity. |
| 9 | S&F in replacementHeating plate assembly with water inlet & outlet, rubber gasket, nuts and bolts and washers of required size suitable for 50 Ltr Capacity Geyser of any type and make complete. |
| 10 | All as per Srl item No 9.00 (here-in-before) but suitable for capacity 25 Ltrs Geyser. |
| 11 | S&F in replacement glass wool for geyser vessel of any size and capacity complete. |
| 12 | S&F in replacement mild steel holding/anchor bolts and nuts machine made of size 10cm to 15cm long and dia of bolt 10mm to 15mm complete.Note :- Anchor bolt shall be grouted with hammer drill only. |
| 13 | S&F in replacement dead nut/Safety plug of brass as per sample suitable for Geyser of any capacity/make. |
| 14 | S&F in replacement inner steel tank of geyser capacity 25 ltr of any type and make to match the existing size and shape of inner tank of Geyser installed at site. |
| 15 | All as per Srl item No 14.00 (here-in-before) but for Geyser of capacity 50 ltrs. |
| 16 | S&F in replacement outer tank of geyser made out of aluminium sheet of existing gauge, shape suitable for inner tank 25 ltr capacity geyser of any make complete. |
| 17 | All as per item No 16.00 (here-in-before)but suitable for 50 ltr capacity geyser. |
| 18 | S&F in replacement socket outlet(enclosure type)suitable for geyser of any type and capacity. |
| 19 | S&F in replacement metal plug top (enclosure type)suitable for geyser of any type and capacity. |
| 20 | S&F in replacement hot water PVC connection of15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete. |
| 21 | S&F in replacement sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one SPNMCB of 20 Amp rating 240 Volt complete.Make :- Optipro of Indo Asian Cat Part No 811956 or equivalent of makes mentioned here-in-after in list of makes. |
| 22 | M&L for soldering/brazing / welding work to stop leakage and other job connected work be required in connection with making geyser functional complete. |
| 23 | S&F in replacement of existing solar heating element 3000 W suitable for any type or size and make of solar heater complete. |
| 24 | S&F in replacement MCB SPN 32 Amps, 240 Volts, 10 KA (\"B\" Curve) complete. Note:- MCBs shall be of same make as that ofDBs. |
| 25 | S&F in replacement MCB SP 06 to 32 Amps, 240 Volts, 10 KA (\"B\" Curve) complete. Note:- MCBs shall be of same make as that ofDBs. |
| 26 | S&F in replacement plug top 15/16 Amp all as specified and directed. |
| 27 | S&F in replacement bottom split inspection cover for geyser of capacity 25 litres of any make. |
| 28 | S&F in replacement bottom split inspection cover for geyser of capacity 50 litres of any make. |
| 29 | Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduitwith switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed. |
| 30 | M&L for point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etcincluding sunk type pressed steel box covered with and including 3 mm thick newbakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. |
| 31 | M&L for point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into existing PVC conduit / PVC casing caping concealed / fixed in wall or surface or ceiling including sunk type pressed steel box covered with and including 3 mm thick newbakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. |
| 32 | S&F in replacement switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts. |
| 33 | S&F in replacement flush type socket outletmultipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed. |
| 34 | S&F in replacement CPVC pipes (outer dia of pipe 16mm) SDR 11 & Plain CPVC SDR 11 fittings laid on wall / ceiling or laying in floor complete all as specified with all fittings / connections and making good to required surfaces by using white cement / masonry works complete all as specified and directed.Note :- Rates quoted shall deemed to be included for making hole / nitch for replacement of pipe and making good distrubed surfaces to match with existing surface and finish all as directed. |
| 35 | S & F in replacement 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions. |
| 36 | S&F in repairs 15 mm bore bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. |