Construction Of Arsenic Free Water Scheme Near Nikari Para Central School Icchapur-I G.P. Mouza- Icchapur-I J.L.-36 Dag.- 1770 1771 Under Gaighata Painchayat Samity Mdw Fund .
Tender Value
14.26 Lakhs
Estimated cost
Bid Submission
24 Sep 2022
0 days left
EMD
28534
Bank guarantee accepted
Document Fee
2930
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
gaighata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Arsenic Free Water Scheme Near Nikari Para Central School Icchapur-I G.P. Mouza- Icchapur-I J.L.-36 Dag.- 1770 1771 Under Gaighata Painchayat Samity Mdw Fund .
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work).(a) With earth obtained from excavation of foundation. |
| 3 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 4 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (ii) 4 mm thick |
| 5 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety](a) 6:3:1 proportion. |
| 6 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Varietyi) In Ground Floor |
| 7 | i) In Ground Floor |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.I. SAIL/ TATA/RINL |
| 9 | i) In Ground Floor |
| 10 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. |
| 11 | 25 mm to 30 mm thick wooden shuttering as per decision & direction of EIC.ii) In Ground Floor |
| 12 | Brick work with first Class bricks in sand Cement morter (1:6)(a) In foundation and plinth. |
| 13 | Brick work with first Class bricks in sand Cement morter (1:4) |
| 14 | (b) In superstructure, Ground floor |
| 15 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) |
| 16 | In Ground Floor |
| 17 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] |
| 18 | i) With 1:6 cement mortar(a) 15 mm thick plaster |
| 19 | In Ground Floor |
| 20 | (b) 20 mm thick plaster |
| 21 | In Ground Floor |
| 22 | (ii) With 1:4 cement mortar(c) 10 mm thick plaster |
| 23 | In Ground Floor |
| 24 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m allcomplete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. (iii) 25 mm. thick. |
| 25 | In Ground Floor |
| 26 | Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc |
| 27 | In Ground Floor |
| 28 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. |
| 29 | (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the (openable portion only] |
| 30 | (viii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flatsand bars. |
| 31 | (b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 32 | (b) On steel or other metal surface : |
| 33 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 34 | In Ground Floor |
| 35 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary |
| 36 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc)complete.A) UPVC Pipes: (ii) 75mm. Dia. |
| 37 | A) UPVC Pipes: (ii) 75mm. Dia. |
| 38 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer. |
| 39 | (e) 3000 litre capacity |
| 40 | (f) 4000 litre capacity |
| 41 | Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity. |
| 42 | (i) Above 1500 lit. Upto 5000 litre capacity. |
| 43 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (ii) 100 mm dia. boring etc. top enlargement |
| 44 | (i) 50 mm dia. boring etc. |
| 45 | (b) For derth more than 150.0 mts. (i) 50 mm dia. boring .Item No 1Page 50 |
| 46 | For raw water and treated water testing of Arsenic from reliable Laboratoty |
| 47 | Supplying high density polythene strainer of approved make with adapterconforming to I.S. specifications.50 mmmdia |
| 48 | Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. 50mm dia |
| 49 | 50mm dia |
| 50 | (l) Reducing Socket (100 mmx 50 mm) |
| 51 | Supply of Galvanised iron Socket with ISI mark(ix) 100 mm dia |
| 52 | 100 mm dia |
| 53 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(A) PVC Pipes. (i) 50 mm dia. |
| 54 | (b) 100 mm dia |
| 55 | Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly : (b) Two coats. (i) Other than yellow, pink. |
| 56 | Internal Surface, Two Coat |
| 57 | External Surface, Two Coat |
| 58 | Supply of G. I. pipes of TATA make including necessary sockets. (h) 100 mm dia. |
| 59 | Supplying, fitting and fixing of G.I Clamp of 450 mm long ,including necessary nut-bolt and grouting with 1:2:4 cement concrete as per direction.(h) 40 mm (i) Medium quality |
| 60 | Supply of G.I.pipes of TATA make including necessary sockets for hanginh (d) 32 mm dia (ii) Medium quality |
| 61 | (g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cockof approved brand and make,spray painted and tested to 21kg per sq. cm. |
| 62 | Installation of Submersible pump with motor having capacity of 1.00 HP(Krilaskar/Crompton) of model 3W10NB(CG) or as approved by the authority including supplying fitting & fixing the same in proper position true to line and level etc. Including the cost of Electrical connectionwith flat cable ,casing,switch etc,and other accessories complete in all respect up to the satisfaction of the authority. With VFD Controller of Approved Brand. |
| 63 | Iron removal filterMOC : FRP Size : 16x65 (Top & Bottom) Media : HLX Nano TechnologyValves & Piping : Side Mounted Multiprot Valve & PVC Piping. |
| 64 | Arsenic removal filterMOC : FRP Size : 14x65 (Top & Bottom) Media : HLX Nano TechnologyValves & Piping : Side Mounted Multiprot Valve & PVC Piping. |
| 65 | Hardness Reduction filterMOC : FRP Size : 14x65 (Top & Bottom) Media : WAC media Valves & Piping : Side Mounted Multiprot Valve & PVC Piping |
| 66 | Carbon filterMOC : FRP Size : 12x48 (Top) Media : Activated Carbon (iv 1200)Valves & Piping : Top Mounted Multiprot Valve & PVC Piping |
| 67 | Dosing Pump Capacity :0-10 LPH at 4 Kg/Cm2 Make : E - Dose |
| 68 | Dosing TankCapacity :150 LitMOC : PVC |
| 69 | Dosing Chemical Grade : Commercial |
| 70 | Conditioning PumpCapacity : 0.25 HPMake : positive/Taha |
| 71 | Conditioning TankCapacity : 300 LitrsMOC: PVC |
| 72 | Conditioning ChemicalGrade : Commercial |
| 73 | UV SterilizerCapacity : 1000 LPH Make : ALFAA MOC :SS |
| 74 | Water ATM Type : Card BasedDispencing tap :3 nos Battery : 12 V (DC & Solar) RFID Card :300 nosIn built modem with GSM : 1 no |
| 75 | Plumbing & Fittings Valves,Pipelines& fitting for plant is in UPC,Raw water tank distribution shower head. |
| 76 | Sludge Materials (For soak pitGravels Size : . 1 Inch |
| 77 | Dolomite ChipsSize : . 1/2 \" to 3/4 \" |
| 78 | Corse SandSize : . Normal |
| 79 | Supplying, installation and lowering in position Solar Panel based submersible pumping machinery (stainless steel fabricated components) with solar cable & cable connector Kit, PV Panel (IEC 61215:2015 certified), Controller, Overhead protection, Dry run protection, Auto Restart facility, Float Switch with Water Level Sensors, Software for start-up of motors, making necessary connections with treatment units with supplying Controller box with necessary wiring, switch board and supplying 32mm dia. PVC column pipe 42 m length as per direction of the EIC. a) Solar Panel configuration: 4 panels of 330 Wp (72 cell) each(Solar panel to be installed on top of M.S Supporting stracture) |
| 80 | Supplying, and installation of Solar DC kit. 1nos 150Wp PV module, 1nos 40ah solar battery, 2nos 10watt dc bulb, 1nos dc fan. |
| 81 | Display Board |
| 82 | Add GST 12.00% [ CGST( 6.00%) + SGST ( 6% ) ] |
| 83 | Add Labour Welfare Cess @ 1.00% |
AI Tender Summary
Tender Timeline
Sep 14, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 28, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender