Military Engineer Services-MES has published Maintenance And Repairs To Various External Electric Supply Items At Base Camp Under Ge Partapur - Taking Out Un-Serviceable / Faulty Cable / Service Connection Cable Of Any Grade / Type / Class Of Any Sizefor Repair / Replacement From Pole / W. Submission Date for this Tender is 12-10-2022. Coats and Jackets Tenders in Partapur Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 05-Oct-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-10-2022 |
Sl. No. | Item Description |
1 | Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any sizefor repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately) |
2 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 10 sqmmall as specified and directed. |
3 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 16 sqmmall as specified and directed. |
4 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 16 sqmmall as specified and directed. |
5 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 25 sqmmall as specified and directed. |
6 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 35 sqmmall as specified and directed. |
7 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 50 sqmmall as specified and directed. |
8 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 70 sqmmall as specified and directed. |
9 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 185 sqmmall as specified and directed. |
10 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 300 sqmmall as specified and directed. |
11 | M&L for line separators of LT OH lines with nut, bolts & washers straight type fixed at a point as directed and suitable for 4 wire complete all as specified and directed by Engr-in-Charge. |
12 | M&L for Painting steel and iron surfaces, old/new surfaces of steel tublar poles/steel tublar swaged poles of any description, length n. exc 9 mtr above ground level incl angle iron/clamps bracket etc with one coat of silver aluminium paint two coat of synthetic enamel paint upto 1.5 mtr above coping in 30 cm wide strips in alternate black and Yellow colour complete all as directed by Engr-in-charge. |
13 | Supply and fixing Aluminium bus bar chamber 3 phase, 200 Amp capacity with 4 nos Al strips not less than 600 mm long, outdoor type including one MCCB of 125 Amps 4 Poleas incommer with locking arangement,grouting in pcc 1:3:6 and connecting with UG XLPE cable with suitable copper thimbles complete all as specified and directed. |
14 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thickburied directly in ground( earth plate not less than 2.25 mtr deep belownormal ground level) with top edge ofearth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron wire 4 mm dia by means of nuts bolts, nuts, check nuts and washersof GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicatedcomplete andincludingcharcoal dust,salt etc and GI protection pipe light grade 40mm bore andGI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge. |
15 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thickburied directly in ground( earth plate not less than 2.25 mtr deep belownormal ground level) with top edge ofearth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron earthstrip of size 32 x 6 mm thick by means of nuts bolts, nuts, check nuts and washersof GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicatedcomplete andincludingcharcoal dust,salt etc and GI protection pipe light grade 40mm bore andGI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge. |
16 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed by Engineer-in-Charge. |
17 | Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, Complete all as specified and directed by Engineer-in-Charge. |
18 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge. |
19 | Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge. |
20 | M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed by Engineer-in-Charge. |
21 | Supply and laying/fixing, GI pipe medium grade 40 mm bore(dia)including all type fittingsfixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed. |
22 | Supply and laying/fixing, GI pipe medium grade 50 mm bore(dia)including all type fittingsfixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed. |
23 | Supply and laying/fixing, GI pipe medium grade 80 mm bore(dia)including all type fittingsfixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed. |
24 | S&F MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 25 KA, adjustable type complete all as specified and directed by Engr-in-Charge. |
25 | S&F MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 36 KA, adjustable type complete all as specified and directed by Engr-in-Charge. |
26 | S&F MCCB 4 Pole, 415 V, 400 Amps with breaking capacity 50 KA, adjustable type complete all as specified and directed by Engr-in-Charge. |
27 | Supply,laying ,testing unarmoured electric cable (service wire) in replacement of size 10 sqmm 2 core complete complete all as specified and directed. |
28 | Material and Labour for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling or mass concrete as in foundation stays etccomplete all as specified and directed by Engr-in-Charge. |
29 | Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 400 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- |
30 | MS Sheet body of LT Panel With double door angle iron frame |
31 | Incomming |
32 | (a)MCCB, 250Amps,36 KA Optium 1.0 (Fixed TM range)4 poleMake : INDOASIAN Cat No 830116-01 Nos |
33 | Outgoing |
34 | (b) MCCB, 125 Amps,25 KA, Optium 1.0 (Fixed TM range)4 pole Make : INDOASIAN Cat No 830050-01 Nos |
35 | (b) MCCB, 63 Amps,16 KA, Optium 1.0 (Fixed TM range)4 pole Make : INDOASIAN Cat No 830050-01 Nos |
36 | (d) MCCB, 25 Amps,16 KA, Optium 1.0 (Fixed TM range)4 pole Make : INDOASIAN Cat No 830016-01 Nos |
37 | (e) MCCB, 16 Amps,10 KA, Optium 1.0 (Fixed TM range)4 pole Make : INDOASIAN Cat No 830710-01 Nos |
38 | (f)LED type phase indicattor lamp (RYB) - 01 Set |
39 | (g)Digital ammeter 0-400A flush type square with selector switch & CTs3 Nos - 01Set |
40 | (h) Digital voltmeter 0-500V flush type square with selector switch - 01 Nos |
41 | (j) Change over 200 Amps Make : INDOASIAN Cat No IN10A200-01 Nos |
42 | Supply and fixing LT cable route direction metal sign board, yellow color circular plate with written indication and fixing arrangement on earth all as directed and specified. |
43 | Deduct Schedule of Credit of Rs (-) 83150.00 (Minus) as listed in Schedule "A" Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount. |