Providing Drinking Water Supply Scheme For Shimla Under Jal Shakti Division Suni Tehsil Suni Distt Shimla Hp Gp Chanoug And Nehra Under Scsp, Shimla-Himachal Pradesh

Irrigation And Public Health Department has published Providing Drinking Water Supply Scheme For Shimla Under Jal Shakti Division Suni Tehsil Suni Distt Shimla Hp Gp Chanoug And Nehra Under Scsp. Submission Date for this Tender is 24-09-2022. Water Supply Project Tenders in Shimla Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33924963
Providing Drinking Water Supply Scheme For Shimla Under Jal Shakti Division Suni Tehsil Suni Distt Shimla Hp Gp Chanoug And Nehra Under Scsp
Open Tender
Indian
Himachal Pradesh
Shimla
24-09-2022

Tender Details

Providing Drinking Water Supply Scheme For Shimla Under Jal Shakti Division Suni Tehsil Suni Distt Shimla Hp Gp Chanoug And Nehra Under Scsp

Key Value

Document Fees
INR 2500 /-
EMD
INR 250800.0 /-
Tender Value
INR 2.18 Crore /-

BOQ Items

Name of Work: Providing drinking Water Supply Scheme for Shimla under Jal Shakti Division Suni Tehsil Suni Distt Shimla HP (GP Chanoug and Nehra) (Under SCSP).
Sl. No. Item Description
1Laying and Jointing PVC Pipe. Heading
2Excavation in foundation trenches etc.in earth work upto all depths in all kinds of soil such as pick work,jumper work,blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of side levelling of bed to correct grade and returning the stacked soil in trenches in 15cm.layers by ramming and watrering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un metalled/metalled paved surfaces to its original conditions including caution boards in all respect and to the entire satisfaction of the Engineer-in-Charge.
3For Site Development , Tanks , Pump House Etc.
4For Pipe Line
5Providing and laying cement concrete 1:5:10(1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with 15 % plum and curing complete excluding cost of form in retaining Walls / breastwalls, the size of plums shall usuallybe 150 mm to 300 mm as per H.P.P.W.D. Specification
6Providing and laying cement concrete 1:2:4 (1cement :2 sand:4 graded crushed stone aggregate and20mm nominal size) and curing complete excluding the cost of form workin foundation and plinth in all leads and lifts.
7Plionth & Foundation
8Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilever up to floor two levels.
91.20 mtr. High fencing with 1.80 mtr. M.S. Angle iron post of size 50 x50x 5 mm (min) including cutting & hosting and welding including painting complete in all respect
101.80 mtr. High fencing with 2.50 mtr. M.S. Angle iron post of size 50 x50x 5 mm (min) 2.50 mtr. Center to center with 9 horizonal lines & twodiagonals Galvanised steel barbed wire (IS-278-1962 Type-I) weighing 9.38 Kg./-per 100 mtr.(Minium) strained and fixed to posts with 6.1 stples linclulding with painting of M.S. angle iron comploete. ( Angle 50x50x5 mmm)
11Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30X30X5 mm so as to give a faie finish i/c centring shuttering strutting and propping etc. with woodan battons & ballies, ht. of propping & centring below supporting floor to ceiling not exceeding 4 mtrs. & removal of the same for insitu-reinforced concrete work in:
12Vertical surfaces such as walls ( any thickness ) partitions and the like including attached pilasters , buttresses, plinth and string courses and the like .
13Flat surfaces such as soffits and suspended floors, roofs , landing and the like:-
14Steel Work in single section including cutting , hoisting , fixing in position and applying a priming coat of lead paint .
15Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in:-
16Foundation and Plinth.
17Providing and laying cement concrete 1:1.5:3 ( 1 cement : 1.5 sand : 3 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work & reinforcement for reinforced concrete work in:-
18Foundation and Plinth.
19Walls (any thickness but not less than 0.1 m thickness) attached pilasters, buttresses, plinth andstring courses etc. from top of foundation level up to floor two level.
20Providing &Supplying of 3 Tone Crane Gantry.
21Providing mild steel/tor Steel reinforcement for R.C.C work including bending , binding and placing in position complete up to floor two level.
22Providing and fixing MS grills of required pattern in wooden frames of windows etc. with MS flats, square or rounded bars with round headed bolts and nuts or by screws.
23Providing in R.C.C work smooth finishing of the exposed surfaces with cement mortar 1 : 3
24Applying Birla White wall care Putty over plaster surface after throughly brushing the surface free from mortar drops , dust , loose , materails and other to give matters sand parpered smooth to give final matter finish to the surface complete.
25Manfacturing MS Manhole Cover 600x450mm with Frame of MS Angle 50x50x6mm and cover of black sheet 2.00mm thick complete with angle frames, flates etc including welding with locking arrangemets(Locks) (excluding Cement Concrete)
26Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in:-
27Foundation and Plinth.
28Providing and laying cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of centering & shuttering in foundation and plinth.
29R/R stone masonry/ Polygonal rubble masonry (uncoursed/brought to courses)with hard stone of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20 mm nominal size) at plinth level in cement mortar 1:6 (1Cement : 6 Sand).
30Brick Work using common burnt clay building bricks in foundation and plinth in cement mortar 1:4 (1 cement : 4 sand) First class bricks.
31Half brick masonry in common burnt clay building bricks in : cement mortar 1:4 (1 cement : 4 sand) first class brick in super-structure.
32Providing wood work in frames of doors, windows, clearstory, windows and other frames wrought, framed and fixed in position: 2nd class deodar wood
33Providing and fixing panelled glazed or panelled and glazed shutters for doors windows & clearestory windows i/c black enamelled iron butt hinges with necessary screws: 40 mm thick 2nd class deodar wood
34Providing and fixing Wire gauge shutters using galvanized M.S Wire gauge of I.S Gauge designation 85 G with wire of dia 0.56 m.m for door windows and clearstory windows i/c black enamelled iron butt hinges with necessary screws: 40 m.m thick 2nd class deodar wood.
3520 mm cement plaster in single coat on the rough side of stone masonry for interior plastering up to floor to level i/c arises, internal rounded angles, chamfers and/or rounded anglesnot exceeding 80 mm in girth and finished even and smooth in c:m 1:6 (1 cement : 6 sand).
3615 mm cement plaster in single coat on the rough side of brick/concrete/stone walls for interior plastering up to floor to level i/c arises, internal rounded angles, chamfers and/or rounded anglesnot exceeding 80 mm in girth and finished even and smooth in c:m 1:6 (1 cement : 6 sand).
376 mm Cement plaster to ceiling ( a) in cement mortar 1:3 ( 1 Cement : 3 Sand )
38Applying priming coat over new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign sand papering and knotting. Ready mixed paint brushing with white wood primer pink.
39Painting two coats ( Excluding priming coat) on new wood and wood based surface with ready mixed paint, brushing to give an even shade including cleaning oil, grease, dirt, dust and other foreign matter sand papering and stopping:-Ready mixed paint other than white.
40Providing 40X3 Flat iron hold fast 40cm long i/c fixing to frame with 10m.m dia bolts nut and wooden pugs and embedded in cement conc. Block 30x10x15 (1 cement: 3 sand:6 graded stone aggregate 20mm nominal size).
41P/F anodized aluminium sliding door bolts and nuts screws etc. complete
42250x16
43P/F anodized aluminium tower bolt anodized transparent or dyed to required shade and colour with screws etc. complete
44250x10
45200x10
46P/F anodized aluminium Handles anodized transparent or dyed to required shade and colour with screws etc. complete.
47125 m.m
48100 mm.
49P/F Oxidized M.S. hooks and eyes
50Boulder filling dry hand packed tightly under floors.
5140 mm thick cement conc. Flooring 1:2:4 ( 1 cement : 2 sand : 4 graded stone agg. 20 m.m nominal size) laid in one layer finished with a floating coat of neat cement.
52Pointing on Brick work with cement mortar 1:3 (1cement : 3 sand) raised and cut.
53Providing Plinth Protection 50 mm thick in cement concrete1:3:6 (1 cement: 3 sand:6 graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth.
54Providing & Placing in horizontal layers Filtering media duly graded, screened,washedand cleaned as specified by the Engineer - in -Charge
55Top Layer
56Second Layer
57Third Layer
58Fourth Layer
59BottomLayer
60Providing and placing Ist class standard bricks in filter bed in two layers so as to make cross drains as per direction of Engineer-in-charge.
61Pumping Machinery 1st Stage
62Providing horizontal spindle horizontal/radial split casing/end section (back pull out arragement) single/double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti WASP/ASPEE as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on acommon C.I/Cast steel base plate(base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof induction motor of standard make such as Kiloksar/Crompton/Bhel/NGEF/ GEC/SIEMEN/ JAYOTI/ABB suitable for operation on 415(+)/-5% volts, 50 cycles/second, 3 phase AC electric supply.The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the opeation range of (+)10% and(-) 15 % of the duty point head.The motor should be as per IS: 325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:-Scheme :-Shakrori Side 1) Discharge (Q) LPS-2.77, LWL in sump well (h)-760.00 mtr, Suction lift 3.00 mtr, Residual Head-03 mtrs., Static Head- 550.00 mtrs. , Total Head - 0586.80 Rising main Length- 1600.00 mtrs., Dia- 65 mm, Pumping hours- 8, Altitude of Installation above MSL:-- mtrs., Characterstic of Water Temperature 0C, Abient Temp 0C, Turbidity Clear water JTU, Alkalanity Mg/CA CO3, Size of the solids Mm, Other
63Providing ICTP Main switchofKilburn/L&T/Siemens/Crompton/Standard/Havells make and having Capacity 30% extra of the Operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
64Providing MS .sheet,steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:
65A.C.B./Oil circuit breaker ofKilburn/L&T/MEI/GEC make& of suitable capacity on incoming feeder with or without initial oil filling as the case may bewith neutral linked under voltage releases as per IS: 2516-1985 with upto date ammendments with.
66Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per 2516-1977 withuptodate ammendment and of suitable range which should have control box operating handle and trip/ reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection.The circuit should be equipped with magnet thermal release with metallic tape etc. It shouldalso befitted with earth fault for tripping of breaker onoccurrence of earth fault on off breaker load side end.
67The voltage monitor relay three phase with all protection and usual indicator and electric siren against single phasing low voltage,high voltage reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition).
6865 mm diameter circular diaA.C. Supply voltmeter of recommended make AE/IMP/ Havells of suitable range with selector switches as per IS:4064-1978 with upto date ammendments.
69Power factor meter of standard make as per relevant IS code with upto date ammendments of suitable rating.
70Frequency meter of standard make as per relevant IS code with upto date ammendments of suitable rating.
71Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current,one copper bar of half the rating of full length for neutral phase as per IS:8084-1976 and IS: 11353-1985 read with BIS 5578-1985 with upto date ammendments
72ICTP switches with HRC fuses of L&T/ Crompton /Kilburn/ Siemens/ standard /Havells make and of suitable capacity as per IS 4064-1978 with upto date ammendments.
73Three phase Indicator lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments.
7465 mm dia circular dialAC supply Ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:1248(P-II) 1983 with upto date ammendments…
75Capacitor of Mechneil/Bhel/GEC/ L&T/ make as per IS:2834-1986 with upto date ammendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to HP offered including cables chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date ammendments.
76Providing suitable Oil immersedstar delta/direct on line /auto -tran former/starter rotor starter of MEI/Kilburn/Jyoti/L&T/Siemens make as per IS8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on pannel board with magnetic type overload release and dashpot, time lag,under voltage release with or without initialoil filling as the case may be with single phase preventor as per IS 1248(P-V)- 1983 with upto date ammendments.
77Providing Hour run meter of recommended make of suitable capacity as per IS:722(Latest edition).
78Prov. Antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS; 6337-1971
79Prov. Cast iron flanged/screw type foot valves with straineras per IS: 4098-1986 with upto date ammendments of Kirloskar/ Mechneil/ Kilburn/ Leader/make65mm
80Providing double flanged Cast Ironsluice valve of leader / Bhel/Kirloskar/Kilburn/GLED/Fouress/ make and of 65mm dia for the delievery line of pump and capable of with standing normal seat pressure as per IS-780-1984 with upto date ammendments
81Providing double flanged Cast Ironsluice valve of leader / Bhel/Kirloskar/Kilburn/GLED/Fouress/ make and of 65mm dia for the delievery line of pump and capable of with standing normal seat pressure as per BS-1414 with upto date ammend
82Providing double flanged(Swing type) Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouressmake and of…65mm dia..mm diahavingbye pass arrangement on the deliveryline of pump and capable of with standingnormal seat pressure as perBS:1868 (P.I) with upto date ammendments
83Providing double flanged Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouressmakeand of 65mm dia.havingbye pass arrangement for Rising Main and capable of with standingnormal seat pressureas perBS:1868 (P.I) with upto date ammendments.
84Providing 65mm diacircular dia pressure gauge of Fiebing/Bourden Prega/precision make complete with all accessories such as stop cock, copper tubing etc. as per IS 3624-1987 with upto date ammendments.
85Precision make complete with all accessories such as stop cock,copper tubing etc. as per IS 3624-1987 with upto date ammendments
86Prov.discharge meter standard make to be tiked on the rising main near the storage tank as per the directions of the Engineer-in-charge as per IS-2373-1981 with upto date ammendments.
87Installation of all the items appearing at Serial No. 40 to 64…as per the systematic drawing attached with the tender documents
88Providing and fixing double flanged MS/GI piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the the rising main respectively complete with all specials such as bends, tees reducers/increasers with companion flanges matching with the relevant specifications of the accessoresasindicated in the drawing No 2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS 1364-1983.The pipes shall be as per relevant IS code and towithstand 1.5 times total head stipulated under item No.1 The size of the various componentsto be asunder:-(I) Suction pipe…65mm dia. (ii)Delivery pipe…65 mm dia.(iii)Common Header65mm dia.andwill extended upto 5 mtrs from the outer wall of the pump house in the direction to be jointed. Providing andlaying copper PVC insulated armoured power cable(one cable carrying all the three phases)of suitable size and capacity to and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of Siemens/Gloster/ JEC/ICC/EICO National/Grandlaymake including all other accessores such as thimbles, flexible,pipes solder,nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
89Providing and fixing double loop earthing and copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts,charcoal and commonsalt,25mmx3mm copper strips/as per IS: 3043-1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc,complete in all respect.
902nd Stage
91Providing horizontal spindle horizontal/radial split casing/end section (back pull out arragement) single/double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti WASP/ASPEE as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on acommon C.I/Cast steel base plate(base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof induction motor of standard make such as Kiloksar/Crompton/Bhel/NGEF/ GEC/SIEMEN/ JAYOTI/ABB suitable for operation on 415(+)/-5% volts, 50 cycles/second, 3 phase AC electric supply.The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the opeation range of (+)10% and(-) 15 % of the duty point head.The motor should be as per IS: 325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:-Scheme :- Sunni Side1) Discharge (Q) LPS-2.77, LWL in sump well (h)-1295.00 mtr, Suction lift 3.00 mtr, Residual Head-03 mtrs., Static Head- 635.00 mtrs. , Total Head :- 696.52 , Rising main Length- 2800 mtrs., Dia- 65 mm, Pumping hours- 8, Altitude of Installation above MSL:-- mtrs., Characterstic of Water Temperature 0C, Abient Temp 0C, Turbidity Clear water JTU, Alkalanity Mg/CA CO3, Size of the solids Mm, Other
92Providing ICTP Main switchofKilburn/L&T/Siemens/Crompton/Standard/Havells make and having Capacity 30% extra of the Operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
93Providing MS .sheet,steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:
94A.C.B./Oil circuit breaker ofKilburn/L&T/MEI/GEC make& of suitable capacity on incoming feeder with or without initial oil filling as the case may bewith neutral linked under voltage releases as per IS: 2516-1985 with upto date ammendments with.
95Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per 2516-1977 withuptodate ammendment and of suitable range which should have control box operating handle and trip/ reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection.The circuit should be equipped with magnet thermal release with metallic tape etc. It shouldalso befitted with earth fault for tripping of breaker onoccurrence of earth fault on off breaker load side end.
96The voltage monitor relay three phase with all protection and usual indicator and electric siren against single phasing low voltage,high voltage reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition).
9765mm diameter circular diaA.C. Supply voltmeter of recommended make AE/IMP/ Havells of suitable range with selector switches as per IS:4064-1978 with upto date ammendments.
98Power factor meter of standard make as per relevant IS code with upto date ammendments of suitable rating.
99Frequency meter of standard make as per relevant IS code with upto date ammendments of suitable rating.
100Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current,one copper bar of half the rating of full length for neutral phase as per IS:8084-1976 and IS: 11353-1985 read with BIS 5578-1985 with upto date ammendments
101ICTP switches with HRC fuses of L&T/Crompton/Kilburn/Siemens/standard/Havells make and of suitable capacity as per IS 4064-1978 with upto date ammendments.
102Three phase Indicator lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments.
10365mm dia circular dialAC supply Ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:1248(P-II) 1983 with upto date ammendments…
104Capacitor of Mechneil/Bhel/GEC/ L&T/ make as per IS:2834-1986 with upto date ammendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to HP offered including cables chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date ammendments.
105Providing suitable Oil immersedstar delta/direct on line /auto -tran former/starter rotor starter of MEI/Kilburn/Jyoti/L&T/Siemens make as per IS8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on pannel board with magnetic type overload release and dashpot, time lag,under voltage release with or without initialoil filling as the case may be with single phase preventor as per IS 1248(P-V)- 1983 with upto date ammendments.
106Providing Hour run meter of recommended make of suitable capacity as per IS:722(Latest edition).
107Prov. Antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS; 6337-1971
108Prov. Cast iron flanged/screw type foot valves with straineras per IS: 4098-1986 with upto date ammendments of Kirloskar/Mechneil/Kilburn/Leader/make65 mm Dia
109Providing double flanged Cast Ironsluice valve of leader / Bhel/Kirloskar/Kilburn/GLED/Fouress/ make and of 65mm dia for the delievery line of pump and capable of with standing normal seat pressure as per IS-780-1984 with upto date ammendments
110Providing double flanged Cast Ironsluice valve of leader / Bhel/Kirloskar/Kilburn/GLED/Fouress/ make and of 65mm dia for the delievery line of pump and capable of with standing normal seat pressure as per BS-1414 with upto date ammend
111Providing double flanged(Swing type) Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouressmake and of…65mm dia..mm diahavingbye pass arrangement on the deliveryline of pump and capable of with standingnormal seat pressure as perBS:1868 (P.I) with upto date ammendments
112Providing double flanged Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouressmakeand of 65mm , dia.havingbye pass arrangement for Rising Main and capable of with standingnormal seat pressureas perBS:1868 (P.I) with upto date ammendments.
113Providing 65mm diacircular dia pressure gauge of Fiebing/Bourden Prega/precision make complete with all accessories such as stop cock, copper tubing etc. as per IS 3624-1987 with upto date ammendments.
114Precision make complete with all accessories such as stop cock,copper tubing etc. as per IS 3624-1987 with upto date ammendments
115Prov.discharge meter standard make to be tiked on the rising main near the storage tank as per the directions of the Engineer-in-charge as per IS-2373-1981 with upto date ammendments.
116Installation of all the items appearing at Serial No. 67 to 91…as per the systematic drawing attached with the tender documents
117Providing and fixing double flanged MS/GI piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the the rising main respectively complete with all specials such as bends, tees reducers/increasers with companion flanges matching with the relevant specifications of the accessoresasindicated in the drawing No 2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS 1364-1983.The pipes shall be as per relevant IS code and towithstand 1.5 times total head stipulated under item No.1 The size of the various componentsto be asunder:-(I) Suction pipe…65 mm dia. (ii)Delivery pipe…65mm dia.(iii)Common Header 65mm dia.andwill extended upto 5 mtrs from the outer wall of the pump house in the direction to be jointed. Providing andlaying copper PVC insulated armoured power cable(one cable carrying all the three phases)of suitable size and capacity to and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of Siemens/Gloster/ JEC/ICC/EICO National/Grandlaymake including all other accessores such as thimbles, flexible,pipes solder,nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
118Providing and fixing double loop earthing and copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts,charcoal and commonsalt,25mmx3mm copper strips/as per IS: 3043-1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc,complete in all respect.
119Rising Main
120Providing , LayingJointing & Testing of plain ended API Pipe with steel gradeconfirming to IS 3183-2007 of thickness as mentioned and The Pipe Shall be bevelled Suitable forbutt Welding including cost of joint with butt welding conforming to BIS 816:1969i/c cost of bends tail pieces tees , reducers , increaser etc. as per site condition nd zinc coating inside & outer Side as per IS 4736-1986 or latest with up todate ammendments . the Laying shall confirm to BIS 5822 - 1970 or latest with up to date ammendments as per directions of Engineer - Incharge (Earth work to be measured and paid for separately including all leads and lifts and carriage of miterial at site.)
121Sr.No.RD LengthDiaClass Thick
1221st Stage0 - 1200 1200 65 mmGr B or L2454.80
1232nd Stage 0 - 35035065 mm Gr B or L245 5.20
124350 - 21001750 65 mm Gr B or L245 4.80
125Laying and Jointing in trenches to be leveled to grades,IS marked GI pipes GMS ( Heavy / Medium grade) of following diameters conforming to IS 1239-1991 ( PartII ) latest with up to date amendments ) having minimum wall thickness as for class of pipe specified below jointed with pipe conforming to tables as specified below of BIS 6392-1971 ( Lautest with up to date amendments ) butt. welded at Both ends according to relevant BISstandards & detailed specifications complete in all respect of technical specifications as per site conditions including flushingt,cleaning & hydraulic testing complete to the best satisfaction of Engineer in charge.
1261st Stage 1200 - 1400200 150 mm GI (H)
1271400 - 1600200 150 mm GI (M)
1282nd Stage2100 - 2450350 150 mm GI (H)
1292450- 2800 350 150 mm GI (M)
130Providing , Welding and Fixing of M.S. Flanges ISI marked conforming to IS : 6392-1971 capable of with standing the test pressure of 1.60 N/mm2 welded on both sides with the pipe complete with nut & 3 mm thcikferrado gasket . The welding is conforming to IS : 3183-1986. including hydraulic testing at site and painting with anticorreshive pasint in side and outside confirming to relevant specfication . the work shell be done including all leads and lifts as per entire satisfaction of Engineer - in - Charge.
131Sr.No.RDLength Dia Class Table
1321st Stage0 - 1000 1000 65 mm Gr B 28
1331000 - 140040065 mm GI (H) 17
1341400 - 1600 20065 mmGI (M)5
1352nd Stage0 - 700 70065 mmGr B34
136700 - 2100 140065 mmGr B 28
1372100 - 2800 70065 mmGI (M)17
138Laying & Jointing in trenches, GMS Tubes (Light Grade), Tube fittings (earth work in trenches to be measured and paid for separately).
13915 mm Dia
14020 mm Dia
14125 mm Dia
14232 mm Dia
14340 mm Dia
14465 mm Dia
145Providing & fixing of brass full way wheel valve.
14615 mm Dia
14720 mm Dia
14825 mm Dia
14932 mm Dia
15040 mm Dia
15165 mm Dia
152Making connection of galvanised steel distribution branch with galvanised mild steel main 20mm to 40mm nominal bore by providing and fixing tee including cutting and threading the pipes complete.