Supply Of Regulated Dc Power Supply 0-128V / 5Aregulated Dc Power Supply 0-128V / 5A, Regulated Dc Power Supply 0-128V / 5A As Per The Technical Specification And Features Given Below. Technical Specification 1. Metering: It Should Be 3 Digit Dphs For Vol, Visakhapatnam-Andhra Pradesh

East Coast Railway has published Supply Of Regulated Dc Power Supply 0-128V / 5Aregulated Dc Power Supply 0-128V / 5A, Regulated Dc Power Supply 0-128V / 5A As Per The Technical Specification And Features Given Below. Technical Specification 1. Metering: It Should Be 3 Digit Dphs For Vol. Submission Date for this Tender is 28-09-2022. Digital Panel Meters Tenders in Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33911828
Supply Of Regulated Dc Power Supply 0-128V / 5Aregulated Dc Power Supply 0-128V / 5A, Regulated Dc Power Supply 0-128V / 5A As Per The Technical Specification And Features Given Below. Technical Specification 1. Metering: It Should Be 3 Digit Dphs For Vol
Tender
Indian
Andhra Pradesh
Visakhapatnam
28-09-2022

Tender Details

Supply Of Regulated Dc Power Supply 0-128V / 5Aregulated Dc Power Supply 0-128V / 5A, Regulated Dc Power Supply 0-128V / 5A As Per The Technical Specification And Features Given Below. Technical Specification 1. Metering: It Should Be 3 Digit Dphs For Voltage And Current Measurement. 2. Meter Accuracy: Plus Or Minus 3 Counts 3. Constant Voltage Mode: Regulation : Line Plus Or Minus 0.01%, Plus Or Minus 2Mv For Plus Or Minus 10% Change In Line Voltage. Load: Plus Or Minus 0.01%, V 2Mv For Load Change From Zero To Full Load, Ripple An Noise: 1Mv Rms Max. 20Hz To 20Mhz 4. Constant Current Mode: Regulation: Line Plus Or Minus 0.05% Plus Or Minus 10Ma For Plus Or Minus 10%Change In Line Voltage, Load: Plus Or Minus 0.05% Plus Or Minus 10Ma For Change In Output Voltage From 0 Volt To Maximum Output Voltage. 5. It Should Be Provided With Led Indication For Constant Voltage / Constant Current Operation Mode. 6. It Should Be Constant Current Type Overload Protection. 7. Opertating Temperature: 0 To 50 Degree Centigrade 8. Temp. Coefficient: Plus Or Minus 0.05% Plus Or Minus 5Mv Per Degree C After Initial Warm Up To 30 Minutes In Voltage Mode. 9. Liine Voltage: 230V Ac Plus Or Minus 10%, Single Phase 50Hz Features: [ 1 ] 1. It Should Be Available With Constant Voltage / Constant Current Operation. [ 2 ] It Should Be Provided With 3 Digit Dpms Two Digital Meters [ 3 ] It Should Be Available With Remote Sensing Facility. [ 4 ] It Should Be High Stability And Close Regulation Plus Or Minus 0.01%

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy