Housing Urban and Rular Development Government Departments Closing in 0 days TDR #33891829

Electric Repair Work Of Govt Residence And Electrical Work For Main Wall Central Jail Ajmer ( Sr-23 )

Issued by Government Departments · ajmer, Rajasthan
Tender Value
10.95 Lakhs
Estimated cost
Bid Submission
29 Sep 2022
0 days left
EMD
21900
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ajmer → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Electric Repair Work Of Govt Residence And Electrical Work For Main Wall Central Jail Ajmer ( Sr-23 )

BOQ

Name of Work : ELECTRICAL WORKS FOR MAIN WALL ATJAIL BULDINGAJMER)
Sl. No. Item Description
1Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet\"s &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR
2Short point (up to 3 mtr.)
3Medium point (up to 6 mtr.)
4Long point (up to 10 mtr.)
5Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
6On board
7Medium point (up to 6 mtr.)
8Long point (up to 10 mtr..)
9Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
10Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy = 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.=0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate/ Report from OEMshall besubmitted. All asper pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
111170mm(+/-10%) LED batten with min. lumen output 2200 lm
12Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and dinbar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
13Metal door (single phase) IK-09 and IP-43 with Metal end box
148 Way (8+2)
15Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure\"A\" attached with this BSR
16Double pole MCB(With B/C curve tripping Characteristics)
1740 A rating
186 A to 32 A rating
19Single pole MCB (With B/C curve tripping Characteristics)
206 A to 32 A rating
21Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure \"A\" attached with this BSR
222 x 2.5 sq. mm. + 1x1.5sqmm
232 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
243x 1.5 sq.mm
25S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure \"A\" attached with this BSR
2620 mm
2725 mm
28Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-ArrmouredAluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %,Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware /PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testingetc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additionaltechnical parameters of product / work refer Annexure \"A\" attached with this BSR
296.0 Sq. mm
303 core
3116.0 Sq. mm
322 core
33Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb inexisting holder or fixture as required with system lumen efficacy =100 lm/Watt output ,pf0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating andFixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . foradditional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR
349 Watt
35Providing & Fixing of of Double ball bearing, copper wounded capacitorstart single phase metallic blade fresh air fan, in existing openingincluding cost of hardware , flexible 3 core copper conductor ,makingconnections, testing etc. as required. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR
36300 mm sweep
37Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 forwater supply suitable for submersible & jet pump with requiredfittings ie socket, elbows, tee etc. complete in all respect. All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR
38for vertical installation
3975 mm OD 6 kg / cm2
40Supply and installation of high tensile low carbon steel rod molecularlybonded with 99.9 % Copper thickness (250 microns) and confirming toUL 467, IS/IEC 62561-2 of following size and length and as per pointmentioned (a), (b), [c), (d), (e) below :-(a) Bore a hole of dia. 100 mm of required length, Place the rod in thecentre of Hole
41filled with anti corrosive conductive compounds with the permanentsealings at both the ends, CPRI/ ERDA tested with RMS capacity ofminimum 30 KA for withstanding 1 second .To ensure the moisturecontent and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for3000mm of resistance lowering earth enhancement material shall beused as a backfill compound. The compound shall be tested form NABLacredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & highconductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 withlatest amendemnts
42Connect the rod with copper Strip/Conductor/Wire with suitableclamp made from tinned copper and SS 304 BoltPlace Heavy duty weather proof poly-propylene earth pit chamberwith lockable Jam free lid suitable for safe working load 5000 Kg or moreof size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.
43Testing of earth resistance for value of 5 ohms or less as required &must record by engineer in charge during site visit and ensure to enter inmeasurment book. Test certificates for confirming above standards from OEM ismandatory. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attachedwith this BSR .
4425 mm thick and 3 Mtr. Long
45Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with this BSR .
468 SWG G.I. ( Hot Dipped ) Wire
47Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressurediecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beamangles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number havingefficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System levelLuminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff@>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA.driver should be Phase to phase protectionof 440 V for 4 Hrs. Electrical Connector , Surge Protection Min>=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hourswith 70% of Initial Lumens maintained, CRI>70 andCCT5700K355K.ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbe IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LEDfixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shallbe submitted. All as per pre approved by Engineer in charge. Foradditionaltechnical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR
48High Power LED Flood Light Minimum lumen output 14800 lm
49High Power LED Flood Light Minimum lumen output 22400 lm
50P & Fixing Powder coated CRCA sheet enclosures on existing angleiron frame by means of nuts and bolts and making holes , Din rail etc.as required.For additional technical parameters of product / workrefer Annexure \"A\" attached with this BSR
512.5 mm thick
52Providing & Fixing of BEE Star rated copper wounded double ballbearing capacitor start, aluminium body & Metallic blade ceiling fanConforming to all the performance requirements laid down in IS374:2019 including all amendments, as applicable ; & Carry BIS licensing(i.e. ISI marking) with down rod up to 80 cm with secondary supportsafety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulatedflexible copper conductor making connection testing etc. as required. Allas per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with thisBSR .
531400 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
54Providing & Fixing of extra down rod of 15 mm dia . ERW (Electricalresistance welded ) of 1.6mm nominal thick medium duty steel pipeincluding cutting, threading, drilling, fixing quarter pin etc as reqd. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with thisBSR
55P/Laying ISI marked P.V.C. insulated submersible cable confirmingto(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemade from 99.90 % purity copper, stranding in acc. to IS:8130/IEC60228 for lower watt loss , oxygen free for less chances of oxidization,insulation PVC type A/C/D , flame retardant as per IS 10810-53, betteramperage rating as per IS:3961 part 5, existing pipe / open trench /Cable tray / on surface including making connection etc. as required.For additional technical parameters of product / work refer Annexure\"A\" attached with this BSR
561.5 Sq.mm 3 core flat / Round
57S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVCtrunking along with accessories like coupler, inner, outer, elbow,square box, tee, end cap etc. on surface with screws, expansionfasteners as required. For additional technical parameters of product /work refer Annexure \"A\" attached with this BSR
5850 mm x 50 mm
59Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.
601400 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
61P & F ISI marked (IS:3854) 6 amp. flush type non modular switch withCM/L no.printed and made out from industrial grade Polycarbonate or fireresistant ABS materialincluding cutting hole in tile and making connectiontesting etc. as required. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \"A\"attached with this BSR .
62Providing & Fixing of 16 amp. Combined flush type non modular socketand switch set with indicator and fuse set as per PWD specification forelectrical Works, made out from industrial grade Polycarbonate or fireresistant ABS material including cutting hole in tile and making connectiontesting etc. as required. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \"A\"attached with this BSR .
63P & F paper phenolic resin bonded laminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, withbrass screws, washers/ zinc plated nut and bolts as required. Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR
643.0 mm thick
65SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB)made of flame retardent & heat resistant material having followingcurrent rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L &S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face andcentralised adjustable, trip free mechanisum, true contact positionindicator, line load interchangeability, designed for both horizontal &vertical mounting without any adverse effect on electrical performance,suitable for operation upto 55 degree and without derating upto 40degree, pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breakingcapacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock &rotary handle , including making connections etc. as required.OEM shallhave submit NABL / CPRI / ERDA accrediated lab type test certificatebefore execution All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR
663 pole MCCB With Thermal Magnetic release
67up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
68Electric repair and maintenance work for govt residence at ajmer jail
69Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet\"s &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR
70Short point (up to 3 mtr.)
71Medium point (up to 6 mtr.)
72Long point (up to 10 mtr.)
73Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
74On board
75Medium point (up to 6 mtr.)
76Long point (up to 10 mtr..)
77Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
78Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.
791200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5
80Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
81Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy = 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.=0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate/ Report from OEMshall besubmitted. All asper pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
821170mm(+/-10%) LED batten with min. lumen output 2200 lm
83Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and dinbar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
848 Way (8+2)
85Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure\"A\" attached with this BSR
86Double pole MCB(With B/C curve tripping Characteristics)
8740 A rating
88Single pole MCB (With B/C curve tripping Characteristics)
896 A to 32 A rating
90Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure \"A\" attached with this BSR
912 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
922 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
932 x 2.5 sq. mm. + 1x1.5sqmm
94S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure \"A\" attached with this BSR
9520 mm
9625 mm
97Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb inexisting holder or fixture as required with system lumen efficacy =100 lm/Watt output ,pf0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating andFixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . foradditional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR
989 Watt
99Providing & Fixing of of Double ball bearing, copper wounded capacitorstart single phase metallic blade fresh air fan, in existing openingincluding cost of hardware , flexible 3 core copper conductor ,makingconnections, testing etc. as required. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR
100225 mm sweep
101Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceilingrose with CM/L no. printed and made out from industrial gradePolycarbonate or fire resistant ABS material, brass terminal & captivescrews including making connection testing etc. as required.All as per preapproved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR
102Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder withCM/L no. printed and made out from industrial grade Polycarbonate or fireresistant ABS material, brass terminal & captive screwsincluding makingconnection testing etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR .
103Providing & Fixing of ISI marked (IS:2268-1994) gong bell with CM/L no.printed including making connection testing etc. as required. All as per preapproved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR .
104Providing & Fixing of following modular accessories as per PWDspecification for electrical Works, made out of unbreakable and fireretardant vergin poly carbonate with brass terminals and captive screws &silver alloy contact tip with IP-20 rating , including all as per pre approvedby Engineer in charge,making connections, testing etc. as required. Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR
105T.V. coaxial socket
106Providing & Fixing of Wiring Accessories OEM fabricated following size GIbox of 1.2 mm thick with earthing terminal and adjustable floating clamp inrecess/ surface suitable for modular accessories as required.All as per preapproved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR .
1071-2 Module
108Providing & Fixing of following size mounting grid plates with cover platesmade from fire retardent UV established high performance engineeringplastic suitable for all universal metal boxes for front installation & removaldirect fit type complete in all respect.All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR .
1091/2 Module
110Supply and installation of high tensile low carbon steel rod molecularlybonded with 99.9 % Copper thickness (250 microns) and confirming toUL 467, IS/IEC 62561-2 of following size and length and as per pointmentioned (a), (b), [c), (d), (e) below :-(a) Bore a hole of dia. 100 mm of required length, Place the rod in thecentre of Hole
111filled with anti corrosive conductive compounds with the permanentsealings at both the ends, CPRI/ ERDA tested with RMS capacity ofminimum 30 KA for withstanding 1 second .To ensure the moisturecontent and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for3000mm of resistance lowering earth enhancement material shall beused as a backfill compound. The compound shall be tested form NABLacredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & highconductivity in nature with carbon as a major content as per referance ofIS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 withlatest amendemnts
112© Connect the rod with copper Strip/Conductor/Wire with suitableclamp made from tinned copper and SS 304 Bolt(d) Place Heavy duty weather proof poly-propylene earth pit chamberwith lockable Jam free lid suitable for safe working load 5000 Kg or moreof size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.(d) Testing of earth resistance for value of 5 ohms or less as required &must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM ismandatory. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
11317.2 mm thick and 3 Mtr. Long
114Supply & Laying following size earth wire in horizontal or vertical run inground/surface/recess including riveting, soldering, saddles, makingconnection with GI/Cu purity purity >95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with thisBSR .
1158 SWG G.I. ( Hot Dipped ) Wire
116Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %,round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cabletray(with cable tie) including testing etc. as required of following size. OEM musthave it\"s own in house NABL accrediated Laboratory for testing procedure as perIS:10810.For additional technical parameters of product / work refer Annexure\"A\" attached with this BSR
11710.0 Sq. mm
1182 core

AI Tender Summary

OUR REF NO 33891829
AUTHORITY Government Departments
TENDER VALUE 10.95 Lakhs
LAST DATE 29-09-2022
Authority
Authority Name Rajasthan Police Housing & Construction Corporation Limited
Work Description Electric Repair Work Of Govt Residence And Electrical Work For Main Wall Central Jail Ajmer ( Sr-23 )
Basic Detail
Tender No NIT No 10 of 2022-23MD, RPIDCL, Jaipur
Bidding Type Tender
Location
City ajmer
State Rajasthan
Key Dates
Publish Date 12 Sep 2022
Submission Date 29 Sep 2022
Open Date 30 Sep 2022
Finance
Tender Value 10.95 Lakhs
Tender Fee 590
EMD 21900
Exemption Not Available
Document List
List-of-approved-make.pdf
Special-Condition.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
Tendernotice_6.pdf
66e0ce2b-d6c4-4730-8007-e2ae662f39ba.html
10-23-Front_Page.pdf
BOQ_525242.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 12, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 30, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

List-of-approved-make.pdf

pdf

Special-Condition.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

Tendernotice_6.pdf

html

66e0ce2b-d6c4-4730-8007-e2ae662f39ba.html

pdf

10-23-Front_Page.pdf

xls

BOQ_525242.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders