All India Institute Of Medical Sciences-AIIMS has published Repair, Replacement And Maintenance Of Water Distribution Pumping Station At Aiims Hospital Complex, Raipur . Submission Date for this Tender is 26-09-2022. Water Pump Tenders in raipur Chhattisgarh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Material and labour for Rewinding of centrifugal motor of capacity 5HP to 10HP AC, 3 Phase, 415 Volts with super enamelled copper winding wire having appropriate class of insulation to the existing class including dismantling of motor pump set and after rewinding, refixing, recoupling with driven equipment, commssioning complete all as specified and directed by Engineer-in-charge. |
2 | Material and labour for Rewinding of centrifugal motor of capacity 15HP AC, 3 Phase, 415 Volts with super enamelled copper winding wire having appropriate class of insulation to the existing class including dismantling of motor pump set and after rewinding, refixing, recoupling with driven equipment, commssioning complete all as specified and directed by Engineer-in-charge. |
3 | Material and labour for Rewinding of centrifugal motor of capacity 25HP AC, 3 Phase, 415 Volts with super enamelled copper winding wire having appropriate class of insulation to the existing class including dismantling of motor pump set and after rewinding, refixing, recoupling with driven equipment, commssioning complete all as specified and directed by Engineer-in-charge. |
4 | Material and labour for servicing, overhauling of Monoblock type centrifugal motor pumps set of capacity 5HP to 10HP AC, 3 Phase, 415 Volts by replacing all unservicable parts/component (Except rewinding and replacement of major items mentioned below from para 1 and 7 to 9) required to ensure uninterrupted smooth and safe operation along with mandatory safety check complete all as specified and directed by Engineer-in-charge. |
5 | Material and labour for servicing, overhauling of Monoblock type centrifugal motor pumps set of capacity 25HP AC, 3 Phase, 415 Volts by replacing all unservicable parts/component (Except rewinding and replacement of major items mentioned below from para 3 and 7 to 9) required to ensure uninterrupted smooth and safe operation along with mandatory safety check complete all as specified and directed by Engineer-in-charge. |
6 | Material and labour for servicing, overhauling of split type centrifugal motor pumps set of capacity 15HP/75HP AC, 3 Phase, 415 Volts by replacing all unservicable parts/component (Except rewinding and replacement of major items mentioned below from para2 and 7 to 9) required to ensure uninterrupted smooth and safe operation along with mandatory safety check complete all as specified and directed by Engineer-in-charge. |
7 | Supply and fixing in replacement of Terminal Box of centrifugal motor of capacity 5HP to 75HP AC, 3 Phase, 415 Voltsincluding connection etc. complete all as specified and directed by Engineer-in-charge. |
8 | Supply and fixing in replacement of Cooling Fan of centrifugal motor of capacity 5HP to 75HP AC, 3 Phase, 415 Voltsincluding connection etc. complete all as specified and directed by Engineer-in-charge. |
9 | Supply and fixing in replacement of Cooling Fan Cover of centrifugal motor of capacity 5HP to 75HP AC, 3 Phase, 415 Voltsincluding connection etc. complete all as specified and directed by Engineer-in-charge. |
10 | Supplying and fixing 0-16kg/cmsq, 100 mm dia, Bourdon type, Class-I, Direct Mounting Industrial Pressure Gauge having Dampening liquid- Liquid glycerine complete all as specified and directed by Engineer- in - Charge. |
11 | Supplying and fixing 0-7kg/cmsq, 100 mm dia, Bourdon type, Class-I, Direct Mounting Industrial Pressure Gauge having Dampening liquid- Liquid glycerine complete all as specified and directed by Engineer- in - Charge. |
12 | Supplying and fixing in replacement of pressure switch KP-36 Range- 2-14 bar, Diff 1-4 bar complete all as specified and directed by Engineer- in - Charge. |
13 | Supplying of Power contactor of capacity 18A/25A Three poles, 415 V to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
14 | Supplying of Power contactor of capacity 40A Three poles, 415 V to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
15 | Supply of Single phase preventor (VSP2) to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
16 | Supply of Phase Sequence Relay (Built-in Aux.Supply, 1 CO Contact)to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
17 | Supply of 3 Ph Digital Ammeter/ Voltmeter with built in Selector Switch having accuracy class of 1 to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
18 | Supply of 6A Ammeter Selector Switch (ASS)/ 6A Voltmeter Selector Switch (VSS)/ 6A A/M Selector Switch (Auto- Manual) to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
19 | Supply of Front Mounted Add on block 2NO+2NC in the existing LT cubicle panel board to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
20 | Supply of O/L relay of rating 45-63A to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
21 | Supply of O/L relay of rating 14-23A/ 12-18A to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
22 | Supply of O/L relay of rating 9-15A/6-10A to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
23 | Supply of Digital timer On Delay to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
24 | Supply of Digital timer Star Delta to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
25 | Supply of R,Y,B (phase) / On-Off indicating LED to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
26 | Supply of Start Stop Push Buttom to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
27 | Supply of 32A Neutral link to replace in the existing LT cubicle panel board as directed by Engineer-in-Charge. |
28 | Supply of Four pole, 100A/200A Standard DMC connection terminal plate with R,Y,B & Bl colour cap to replace in existing LT cubicle panel board as directed by Engineer-in-Charge. |