Special Repair Replacement To Summer Cooling Appliance Against Ber Under Ge ( East ) , Ber Zone B Area And Other Sanctioned Works Of Cod And Cqa ( W ) Under Age Em Of Ge ( East ) Jabalpur As Per Boq, jabalpur-Madhya Pradesh

Military Engineer Services-MES has published Special Repair Replacement To Summer Cooling Appliance Against Ber Under Ge ( East ) , Ber Zone B Area And Other Sanctioned Works Of Cod And Cqa ( W ) Under Age Em Of Ge ( East ) Jabalpur As Per Boq. Submission Date for this Tender is 06-10-2022. Air Conditioner Tenders in jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33872214
Corrigendum : Special Repair Replacement To Summer Cooling Appliance Against Ber Under Ge ( East ) , Ber Zone B Area And Other Sanctioned Works Of Cod And Cqa ( W ) Under Age Em Of Ge ( East ) Jabalpur As Per Boq
Open Tender
Indian
Madhya Pradesh
jabalpur
06-10-2022

Tender Details

Special Repair Replacement To Summer Cooling Appliance Against Ber Under Ge ( East ) , Ber Zone B Area And Other Sanctioned Works Of Cod And Cqa ( W ) Under Age Em Of Ge ( East ) Jabalpur As Per Boq

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 94500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : SPECIAL REPAIR/REPLACEMENT TO SUMMER COOLING APPLIANCE AGAINST BER UNDER GE (EAST),BER ZONE ‘B’AREA AND OTHER SANCTIONED WORKS OF COD AND CQA (W) UNDER AGE E/M) OF GE (EAST) JABALPUR
Sl. No. Item Description
1Supply and fix single pole and neutralsheet metal enclosuerwith 2 pin and earth plug with socket complete with one single pole MCB 20 Amps.Make - L&T /HAVELLS/ LEGRAD.
2Supply and fix Voltage stabilizer for automatic operation, single phase, 230 Volt, 50 Hz naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA.Make- Sanitrac/Volina
3Supply and fix desert cooler electric driven (single phase), 230 Volt, 50 Hz, having nominal air flow capacity of 6000 CuM per hour (or nearest size). (*Steel body).Make : Khetan/Bajaj/Crompton
4Supply and fix air cooled split unit air conditioner electric driven, single phase, 230 Volt, 50 Hz of capacity of 2.0 TR, BEE 5 star rated all as specified and directed.Make : Llyod-Havells/Whirlpool/LG/Samsung/Voltas Cat Part No 183 VCZJ.
5Supply, installation, commissioning of Water cooler partially stainless steel, electric driven single phase, 230 Volt, 50 Hz, having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour. Make : Whirlpool/Shriram/Voltas/Blue Star Cat Part NoSD LX4080B.
6Supply and fix refrigerators, electric driven (single phase), 230 Volt, 50 Hz capacity more than 310Litres .BEE 5 star rated. Make : Voltas/Whirlpool/LG/Voltas/Samsung Cat Part No 34 A4622S8.
7M&L for sub main wiring with two run of2.5 sqmm single core multi stranded PVC insulated and unsheathed copper conductor(red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduitsof desired colour not less than1.2 mm thick and 25 mm wide& 1.5 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
8Supply andlayingcable XLPE insulated screened PVC bedded, galvanisedsteel strip or wire, armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminiumconductor 10 Sqmm 2 core. Make:- Havells or Gloster or Polycab as approved by GE.
9M&L for Earthing complete with galvanized steel earth plate electrods of size 60cm x 60cm x 6mm thick burried directly in ground vertically (earth pit not less than 3.35 mtr deep below normal ground level) with top edge of the plate not less than 2.75 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm as earthing lead by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.5 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and commansalt in alternate layers 25 mm dia light grade GI pipe, funnel, wire mesh. concrete 1:3:6 type C-1 for pit and RCC pit cover. PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the watering pipe, bends, elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4 type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm.
10Taking down carefully VCB, incomer/outgoing feeder complete removing with connectiong material complete and diposited to MESstore for keeping in safe custody or re-use at site.
11Supply and installation of HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp of indoor complete.Make:- ABB, GE, CG or equvelent as approved by GE.
12Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm. Make:- Havells or Gloster or Polycab as approved by GE.
13Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
14Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
15Removal of surplus/spoil on a distance n.exc 25 cm thick in soft loose soil all as specified.
16Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm laid in trenches for under ground cable all as specified.
17M&L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified.
18M&L for cable protection GI tubinglight grade fixed long the pole/under road/along the wall of size 80 mm bore with necessary clamps all as directed.
19Material and labour for end termination out door 11 KV (Earthed) grade cold shrink type jointing kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm all as specified and directed.
20Supply and fix HT Rubber mat of 1 meter x 2 meter x 10 mm thick complete all as specified and as directed.
21Supply andlayingcable XLPE insulated screened PVC bedded, galvanisedsteel strip or wire, armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminiumconductor 25 Sqmm 4 core. Make:- Havells or Finolex or Gloster or Polucab as approved by GE.
22Supply and fixing LED flood light 70 Watt with high luminous with front toughened glass,protection class IP-66 White Warmof Make Bajaj Cat Part No BJFL200 WLED IWW or eqivelent Havells/Philips/Halonix
23Schedule of credit amount of Rs. NIL to be deducted during AOC