| 1 | Supply Installation Testing Commissioningof Mono (3000K) linear wallwasher made of aluminium extrusion, LED Make : CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG, exterior-rated linear luminaire (1000mm), Input Power 24W, Rated input supply of Input Voltage 24V DC, Luminaire luminous flux Minimum range 960Lm. IP protection rating : IP66. The luminaire should have multiple beam angle options : 10°, 20, 40, 60°, 10X20° ( as per site requirement ). Approved makes:Philips,GE, Ligman, Orient Electric |
| 2 | Supply Installation Testing Commissioningof following Luminaries: Supply of LED projector light fixture 200W LED, MONO (3000k), IP 66. The housing should be made of high strength pressure die cast aluminium with 3-4mm thick safety glass and coated by static powder making it weather resistant.Protection screen with tempered glass with high impact resistance IK07. Voltage input AC240V . The luminaire should have options for beam angle: 10°. Estimated LED Lifetime is L70-50,000 hours minimum@ 25degree Ambient Temperature and LEDs of CREE / OSRAM / NICHIA to be used. Minimum Light fixture Lumen output atleast 12000 Lumens @ full power. Operating Temperature : - 20°C to +50°C. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements.Approved makes:Philips,GE, Ligman, Orient Electric |
| 3 | Supply Installation Testing Commissioningof following Luminaries: Supply of LED projector light fixture 72W LED, RGB (DMX512 Compatible), IP 66. The housing should be made of high strength pressure die cast aluminium with 3-4mm thick safety glass and coated by static powder making it weather resistant.Protection screen with tempered glass with high impact resistance IK07. Voltage input AC240V . The luminaire should have options for various beam angle:25°. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt the light fixture. Estimated LED Lifetime is L70-100,000 hours minimum@ 25degree Ambient Temperature and LEDs of CREE / OSRAM / NICHIA to be used. Minimum Light fixture Lumen output atleast 2880 Lumens @ full power. Operating Temperature : - 20°C to +50°C. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements.Approved makes:Philips,GE, Ligman, Orient Electric |
| 4 | Supply Installation Testing Commissioningof following Luminaries: Supply of LED projector light fixture 200W LED, RGB (DMX512 Compatible), IP 66. The housing should be made of high strength pressure die cast aluminium with 3-4mm thick safety glass and coated by static powder making it weather resistant.Protection screen with tempered glass with high impact resistance IK07. Voltage input AC240V . The luminaire should have beam angle:25°. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt the light fixture. Estimated LED Lifetime is L70-100,000 hours minimum@ 25degree Ambient Temperature and LEDs of CREE / OSRAM / NICHIA to be used. Minimum Light fixture Lumen output atleast 8000 Lumens @ full power. Operating Temperature : - 20°C to +50°C. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements.Approved makes:Philips,GE, Ligman, Orient Electric |
| 5 | Supply Installation Testing Commissioningof Signal Booster/Splitter with 4-Way output for spreading and amplyfing the DMX Data signals in multiple directions, Input-220-240V AC.Approved makes:Philips,GE, Ligman, Orient Electric |
| 6 | Supply Installation Testing Commissioningof2X512 DMX 512 Controller.Approved makes:Philips,GE, Ligman, Nicolaudie,Orient Electric |
| 7 | Supply Installation Testing Commissioningof IP67 power supply 24V output. Power consumption- 200W.Approved makes:Philips,GE, Ligman, Orient Electric, Meanwell |
| 8 | Supply Installation Testing Commissioningof DMX Special cable DMX cable (single pair) having one 22AWG pair stranded (7x30) tinned copper conductors, Datalene (FHDPE) insulation, twisted pairs, overall Beldfoil shield (100% coverage) plus tinned copper braid, PVC jacketCable.Make: krystal, Beldon,Sommer, Chetan |
| 9 | Supply Installation Testing Commissioningof Programming, Testing, Troubleshooting and synchronization of exisitng DMX control system with the new controller. The shifting of various data wire connections for the proper scene settings including the addressing of fixtures with the multiple scenes(atleast 20Themes) as per instruction of engineer in charge.Make: custom |
| 10 | Supply Installation Testing Commissioningof Mounting Brackets/ Cages for fixtures.Make: Custom |
| 11 | Supply Installation Testing Commissioningofenclosure for DMX splitter, controller : Plain sides, grey cover, Degree of protection: IP 66/ IP 67, Impact strenght: IK 08, Material, base: Fiberglass reinforced polycarbonate, Material, cover: Polycarbonate, Material, cover screws: Polyamide, Material, gasket: Polyurethane, Colour: RAL 7035Make:Hengle, Orient electric, philips, Datus |
| 12 | Electrical Items |
| 13 | Timer Based Light Control Panel (Feeder Pillar) |
| 14 | Supply Installation Testing Commissioningoffollowing CPRI tested Timer Based Light Control Panel (Feeder Pillar) including MS Stand suitable for 415V, 3 phase, 4 wire, 50 Hz, power supply distribution system. The panel shall be 2.0mm sheet metal enclosed, double door conforming to IP 54. The painting process shall conform to relevant IS code for out door application. |
| 15 | INCOMING : |
| 16 | 32A 10KA FP MCB - 1 No. + Indication Lamp + 32A FP CONTACTOR (AC-1 duty) + A/M Selector switch + Time switch including making connection, etc. as required |
| 17 | OUTGOING : 10A 10KA SP MCB - 20 Nos. |
| 18 | Complete Set of Feeder Pillar as above |
| 19 | LTCABLE |
| 20 | Supply Installation Testing Commissioningof P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in existing pipe including making necessary connection, testing etc. as required of sizeMakes: HAvells , Polycab, Finolex, Kei |
| 21 | 4.0C x 10 Sqmm Al. Ar. LT XLPE |
| 22 | Cable Termination |
| 23 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Makes: HAvells , Polycab, Finolex, Kei |
| 24 | 4.0C x 10 Sqmm Al. Ar. LT XLPE |
| 25 | Copper Flexible Wire |
| 26 | P/Laying P.V.C. insulated & P.V.C. sheathed cable of 1.1 KV grade with flexible copper conductor confirming to IS:694 in existing pipe/ conduit including making necessary connection, testing etc. as required of size.Makes: HAvells , Polycab, Finolex, Kei |
| 27 | 3.0C x 2.5 Sqmm Copper Flexible Wire |
| 28 | 3.0C x 1.5 Sqmm Copper Flexible Wire |
| 29 | Pipes & Conduits: Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. Make: Ashoka, jain, Jindal, Telerex, kissan |
| 30 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 31 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: 25 mm. Make: Anchor/Polycab/Diplast |
| 32 | Supply & fixing of outdoor type cable junction box IP65/66 with terminals suitable for terminating 2.5/1.5 sqmm Cu flexible cable including all acessories.Makes: Custom |
| 33 | EARTHING:- Supply Installation Testing Commissioningof chemical Gel earthing system of Dual Pipe Technology made of with \"B\" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :-(a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second.(b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts(c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell |
| 34 | GI pipe 2000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip |
| 35 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 36 | Supply Installation testing Commissioning of High quality music horn for excellent speech and music reproduction, Two-way systemHigh sensitivity,Wide opening angle, Simple power setting,Sound pressure level at 30 W / 1 W (1 kHz, 1 m) 112 dB / 97 dB (SPL) ,Sound pressure level,at 30 W / 1 W (2 kHz, 1 m),113 dB / 98 dB (SPL),Effective frequency range (-10 dB)125 Hz to 20 kHz,Opening angle 1 kHz / 4 kHz (-6 dB),horizontal 105° / 90° vertical 110° / 125°Make: Bosch, Audio technica, Martin Audio, Aties |
| 37 | Supply Installation testing Commissioning of 480 watt amplifier . Make: Bosch, Audio technica, Martin Audio, Aties |
| 38 | Providing and fixing 25 mm X 3 mm G.I. strip on surface or in recess for connections etc. as required. |