Revamping Of Existing Ductable Ac System In Sri Kalyana Venkateswara Swamy Temple, Srinivasamangapuram , Dx Type Aircooled Condensing Units: Supply , Installation , Testing And Commisioning Of 11 Tr Nominal Capacity Air Cooled Condensing Unit Cons, guntur-Andhra Pradesh

Tirumala Tirupati Devasthanams-TTD has published Revamping Of Existing Ductable Ac System In Sri Kalyana Venkateswara Swamy Temple, Srinivasamangapuram , Dx Type Aircooled Condensing Units: Supply , Installation , Testing And Commisioning Of 11 Tr Nominal Capacity Air Cooled Condensing Unit Cons. Submission Date for this Tender is 16-09-2022. Spare Part Tenders in guntur Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33850885
Revamping Of Existing Ductable Ac System In Sri Kalyana Venkateswara Swamy Temple, Srinivasamangapuram , Dx Type Aircooled Condensing Units: Supply , Installation , Testing And Commisioning Of 11 Tr Nominal Capacity Air Cooled Condensing Unit Cons
Open Tender
Indian
Andhra Pradesh
guntur
16-09-2022

Tender Details

Revamping Of Existing Ductable Ac System In Sri Kalyana Venkateswara Swamy Temple, Srinivasamangapuram , Dx Type Aircooled Condensing Units: Supply , Installation , Testing And Commisioning Of 11 Tr Nominal Capacity Air Cooled Condensing Unit Consisting Of Scroll Compressor, Copper Condenser Coil Of Copper Tubes And Blue Hydrophilic Coated Aluminium Fins , Condenser Fans, Etc Suitable For Operating On Eco Friendly Refrigerant R- 407C Including Necessary Accessories Like Rubber Pads Etc.Make : Voltas / Blue Star / Daikin / Toshiba / Mitsubishi, Copper Refrigerant Pipingsupply, Installation And Testing Of 19 G Hard Copper Piping Of Following Sizes ( The Suction Line To Be Insulated With 19 Mm Thick Class O Armaflex With Gc Closed Cell Nitrile Rubber Precovered Tubes With Factory Laminated Glass Cloth ) Including Supporting Fixtures And Accessories Etc. Complete.7 / 8 Inches Dia Copper Pipe, Copper Refrigerant Pipingsupply, Installation And Testing Of 19 G Hard Copper Piping Of Following Sizes ( The Suction Line To Be Insulated With 19 Mm Thick Class O Armaflex With Gc Closed Cell Nitrile Rubber Precovered Tubes With Factory Laminated Glass Cloth ) Including Supporting Fixtures And Accessories Etc. Complete.1.1 / 8 Inches Dia Copper Pipe With Insulation, Supply And Installation Of Suitable New Thermostatic Expansion Valve And Catch All Filter Driers Along With Necessary Fittingsmake : Sporlan / Alco, Providing Of R-407C Refrigerant, Supply And Installation Of Microprocessor Based Electrical Panel With Suitable Rating Incoming Mccb With Digital Kwh Meter And Outgoing Feeders With Suitable Rating Mcbs To The 3 No.S 11 Tr Condensing Units And 1 No. Ahu .Make : Softhard / Bluevolt, Supply And Laying Power / Control Cabling Of Following Sizes.Make : Finolex / Polycabpower Cabling From Panel To Condensing Units ( Compressor ) - 3C X 6 Sqmm Copper Armoured, Supply And Laying Power / Control Cabling Of Following Sizes.Make : Finolex / Polycabpower Cabling From Panel To Ahu Fan Motor - 3C X 4 Sqmm Copper Armoured, Supply And Laying Power / Control Cabling Of Following Sizes.Make : Finolex / Polycabpower Cum Control Cabling From Panel To Condensing Unit ( Condenser Fans Plus Control ) -7C X 1.5 Sqmm Copper Armoured, Supply And Laying Power / Control Cabling Of Following Sizes.Make : Finolex / Polycabcontrol Cabling Between Thermostat And Panel - 3C X 1.5 Sqmm Copper Armoured, Supply, Transportation And Installation Of Following Sizes Of Hot Dipped Galvanized Iron Perforated Cable Trays Without Cover, Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling / Wall With Suspenders Etc., Complete ( Nb: Add 30% Extra For Perforated Cable Tray With Cover ) 100Mm X 50Mm X 1.6Mm, Supply, Transportation And Installation Of Following Sizes Of Hot Dipped Galvanized Iron Perforated Cable Trays Without Cover, Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling / Wall With Suspenders Etc., Complete ( Nb: Add 30% Extra For Perforated Cable Tray With Cover ) 300Mm X 50Mm X 1.6Mm, Earthing 8 Swg Gi Wire, Air Handling Unit ( Ahu ) Supply , Installation , Testing And Commissioning Of New Air Handling Unit ( Horizontal Floor Mounted ) In Double Skin Construction With 0.8 Mm Plain G.I. Inner Skin And 0.8 Mm Pre-Coated Gi Outer Skin , Thermal Break Aluminium Profile With Thermal Barrier , 43Mm Thick Puf Panels . The Air Handling Unit Shall Consist Of Face Mounted 50Mm Thick 20 Micron Filters , Coil Section With 6-Rows Deep 3-Circuit Interlaced Dx Cooling Coil Of 12.5 Mm Od Copper Tubes With Aluminium Fins And G.I. Casing , Suitable Number Of Distributors , 18G Ss-304 Drain Pan Duly Insulated With 13Mm Closed Cell Nitrile Rubber Insulation , Fan Section With Didw Centrifugal Fan , Eff2 Motor . The Air Handling Units Shall Consist Of Suitable Vibration Isolators, Access Door, Gss Channel Base Frame And Aluminium Volume Control Damper At Outlet . The Face Velocity Across Coils And Filters Shall Be Maximum 500 Fpm. The Fans Shall Be Selected Considering A Maximum Outlet Velocity Of 10 M / S. Fire Retardant Type Flexible Duct Connector And Vibration Isolation Rubber Pads Shall Also Be Provided. The Ahu Shall Be Suitable For Outdoor Installation With Canopy. Apart From Thefilters Fixed In The Ahu , One Additional Set Of Spare Filters Shall Also Be Provided. Capacity 4300 Cfm Airflowrate At The Rate Of 60 Mmwc Static Make : Flaktwoods / Systemair / Sagar Air Fan : Nicotra / Kruger , Motor : Crompton / Abb, Air Handling Unit ( Ahu ) Dismantling And Shifting Of Existing 1 No. Of 15Tr Air Handling Unit Along With Its Air Cooled Condenser., Supply And Installation Of Rectangular G.S.S. Ducting With Ms Angle Flanges , Complete With Gaskets And Supporting Arrangement Using Ms Angles / Gi Threaded Rods Etc.Make : Jindal / Tata24g, Duct Thermal Insulationsupply And Fixing Of External Duct Insulation With 19 Mm Thick Closed Cell Elastomeric Nitrile Rubber Covered With 24G Aluminium Cladding., Duct Thermal Insulationsupply And Fixing Of Internal Duct Insulation With 12 Mm Thick Closed Cell Elastomeric Nitrile Rubber - Anti Microbial, Painting Of Ducts With One Coat Of Zinc Chromate Yellow Primer And 2 Coats Of Enamel Paint Of Approved Colour., Supply And Installation Of 32 Mm Diameter Drain Piping Using Upvc Pipes Along With Necessary Fittings .Make : Tata / Jindal, Supply And Fixing Of Fusible Link Type Fire Damper ( Sleeve Mounted ) Make : Ruskin / Greenheck, Supply And Fixing Of Extruded Aluminium Duct Mounted Volume Control Dampersmake : Systemair / Vj Air, Supply And Fixing Of Extruded Aluminium Double Deflection Type Supply Air Grilles With Volume Control Dampers Make : Systemair / Vj Air, Providing And Fixing For Ms Support Structure For Laying Of Duct From Garden To Inside Temple Along Horizontal And Vertical Runs Upto The Height Including Cutting, Welding Etc., And Applying Two Coats Of Red Oxide And Two Coats Of Synthetic Enamelled Paint Of Colour And Shade As Directed By Engineer-In-Charge. The Design Of The Support Structure Shall Be Done And Also To Get The Approval From The Site Incharge, Buy Back Of Old Ahu-1 No , Out Door Units ( 7.5 Tr X 2Nos And Other Related Piping, Ducting Etc ) , Comprehensive Annual Maintenance Charges Of Ac Plant After Warranty Period Of 2 Years For Srinivasa Mangapuram Temple Amc Charges For First Year After Warranty Period Of 2 Years, Comprehensive Annual Maintenance Charges Of Ac Plant After Warranty Period Of 2 Years For Srinivasa Mangapuram Temple Amc Charges For Second Year After Warranty Period Of 2 Years, Comprehensive Annual Maintenance Charges Of Ac Plant After Warranty Period Of 2 Years For Srinivasa Mangapuram Temple Amc Charges For Third Year After Warranty Period Of 2 Years

Key Value

Document Fees
Refer document
EMD
INR 47000.0 /-
Tender Value
Refer document

BOQ Items

Sl. No. Item Name
1DX TYPE AIRCOOLED CONDENSING UNITS: Supply , installation , testing and commisioning of 11 TR nominal capacity Air cooled condensing unit consisting of scroll compressor, copper condenser coil of copper tubes and blue hydrophilic coated aluminium fins , condenser fans, etc suitable for operating on eco friendly refrigerant R- 407C including necessary accessories like rubber pads etc. Make : Voltas / Blue star / Daikin / Toshiba / Mitsubishi
2COPPER REFRIGERANT PIPING Supply, installation and testing of 19 G Hard copper piping of following sizes (the suction line to be insulated with 19 mm thick class O Armaflex with GC closed cell Nitrile Rubber precovered tubes with factory laminated glass cloth) including supporting fixtures and accessories etc. complete. 7/8 inches Dia copper pipe
3COPPER REFRIGERANT PIPING Supply, installation and testing of 19 G Hard copper piping of following sizes (the suction line to be insulated with 19 mm thick class O Armaflex with GC closed cell Nitrile Rubber precovered tubes with factory laminated glass cloth) including supporting fixtures and accessories etc. complete. 1.1/8 inches Dia copper pipe with insulation
4Supply and installation of suitable new thermostatic expansion valve and catch all filter driers along with necessary fittings Make : Sporlan / Alco
5Providing of R-407C Refrigerant
6Supply and installation of Microprocessor based Electrical panel with suitable rating incoming MCCB with digital KWH meter and outgoing feeders with suitable rating MCBs to the 3 no.s 11 TR condensing units and 1 no. AHU . Make : Softhard / Bluevolt
7Supply and laying power / control cabling of following sizes. Make : Finolex / Polycab power cabling from panel to condensing units (compressor) - 3C x 6 Sqmm copper armoured
8Supply and laying power / control cabling of following sizes. Make : Finolex / Polycab power cabling from panel to AHU fan motor - 3C x 4 Sqmm copper armoured
9Supply and laying power / control cabling of following sizes. Make : Finolex / Polycab power cum control cabling from panel to condensing unit (condenser fans plus control) -7C x 1.5 Sqmm copper armoured
10Supply and laying power / control cabling of following sizes. Make : Finolex / Polycab control cabling between thermostat and Panel - 3C X 1.5 sqmm copper armoured
11Supply, transportation and installation of following sizes of Hot Dipped Galvanized Iron perforated cable trays without cover, including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling / Wall with suspenders etc., complete (NB: Add 30% Extra for perforated cable tray with cover) 100mm x 50mm x 1.6mm
12Supply, transportation and installation of following sizes of Hot Dipped Galvanized Iron perforated cable trays without cover, including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling / Wall with suspenders etc., complete (NB: Add 30% Extra for perforated cable tray with cover) 300mm x 50mm x 1.6mm
13Earthing 8 swg GI wire
14Air Handling Unit (AHU)Supply , installation , testing and commissioning of new Air handling unit (horizontal floor mounted) in double skin construction with 0.8 mm plain G.I. inner skin and 0.8 mm pre-coated GI outer skin , thermal break Aluminium profile with thermal barrier , 43mm thick PUF panels . The air handling unit shall consist of face mounted 50mm thick 20 micron filters , coil section with 6-rows deep 3-circuit interlaced DX cooling coil of 12.5 mm OD copper tubes with Aluminium fins and G.I. casing , suitable number of distributors , 18G SS-304 drain pan duly insulated with 13mm closed cell nitrile rubber insulation , fan section with DIDW centrifugal fan , EFF2 motor . The air handling units shall consist of suitable vibration isolators, access door, GSS channel base frame and aluminium volume control damper at outlet . The face velocity across coils and filters shall be maximum 500 FPM. The fans shall be selected considering a maximum outlet velocity of 10 m/s. Fire retardant type flexible duct connector and vibration isolation rubber pads shall also be provided. The AHU shall be suitable for outdoor installation with canopy. Apart from the filters fixed in the AHU , one additional set of spare filters shall also be provided. Capacity 4300 cfm airflowrate at the rate of 60 mmwc static Make : Flaktwoods / Systemair/ Sagar Air Fan : Nicotra / Kruger , Motor : Crompton / ABB
15Air Handling Unit (AHU) Dismantling and shifting of existing 1 No. of 15TR Air handling unit along with its Air cooled condenser.
16Supply and installation of Rectangular G.S.S. Ducting with MS angle flanges , complete with gaskets and supporting arrangement using MS angles/GI threaded rods etc. Make : Jindal / Tata 24G
17Duct thermal insulation Supply and fixing of external duct insulation with 19 mm thick closed cell elastomeric nitrile rubber covered with 24G Aluminium cladding.
18Duct thermal insulation Supply and fixing of internal duct insulation with 12 mm thick closed cell elastomeric nitrile rubber - anti microbial
19Painting of ducts with one coat of zinc chromate yellow primer and 2 coats of enamel paint of approved colour.
20Supply and installation of 32 mm diameter drain piping using UPVC pipes along with necessary fittings . Make : Tata / Jindal
21Supply and fixing of fusible link type fire damper (sleeve mounted) Make : Ruskin / Greenheck
22Supply and fixing of extruded aluminium duct mounted volume control dampers Make : Systemair / VJ Air
23Supply and fixing of extruded aluminium double deflection type supply air grilles with volume control dampers Make : Systemair / VJ Air
24Providing and fixing for MS support structure for laying of duct from Garden to inside temple along horizontal and vertical runs upto the height including cutting, welding etc., and applying two coats of red oxide and two coats of synthetic enamelled paint of colour and shade as directed by Engineer-in-charge. The design of the support structure shall be done and also to get the approval from the site incharge
25Buy Back of Old AHU-1 No , Out door units ( 7 .5 TR X 2Nos and other related piping, Ducting etc)
26Comprehensive annual maintenance charges of AC plant after warranty period of 2 years for Srinivasa mangapuram temple AMC charges for first year after warranty period of 2 years
27Comprehensive annual maintenance charges of AC plant after warranty period of 2 years for Srinivasa mangapuram temple AMC charges for second year after warranty period of 2 years
28Comprehensive annual maintenance charges of AC plant after warranty period of 2 years for Srinivasa mangapuram temple AMC charges for Third year after warranty period of 2 years