tender for Water Supply Scheme Jal Jeevan Mission At Honmurgi Tal - South Solapur Dist.Solapur
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Sep 2022
0 days left
EMD
1.18 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
solapur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
tender for Water Supply Scheme Jal Jeevan Mission At Honmurgi Tal - South Solapur Dist.Solapur
BOQ
| Sl. No. | Item Description |
| 1 | PERCOLATION WELL ITEM NO 1 Excavation in general in soft material comprising of soft soil, soft murum,sand, hard murum with boulders in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-incharge, etc. complete excluding refilling. ((b) For Head Works on nalla or any other site of GSDA for initial lift lift15.0 -16.5 m.MJP DSR-2021-) |
| 2 | lift16.5 -18.0 m |
| 3 | lift18.0 - 19.5m |
| 4 | lift19.5 - 21.0m |
| 5 | ITEM NO 3Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261).MJP DSR-2021-22, P.No-45(14) |
| 6 | ITEM NO 4Taking Horizontal bore well with boring machine in soil,Hard murrum & Hard rock upto 150mm dai etc.. Complete. |
| 7 | ITEM NO 7 Desilting the Supply Well, Intake Well / HeadWorks, Sump of water supply / sewerage works etc. in wet or dry condition including lifts upto 9 M and lead upto 150 M as required beyond the work site, stacking, spreading, including necessary guarding, etc. complete, as directed by Engineer-in-charge upto 9 m |
| 8 | lift 9-10.5 m |
| 9 | lift 10.5-12 m |
| 10 | lift 12-13.5 m |
| 11 | lift 13.5- 15m |
| 12 | SWITCH ROOM ITEM NO 1 Excavation for foundation/pipe trenches in earth soil, of all types sand, gravel & soft murum including removing the excavated material upto a lead of 50 m & lift as blow, stacking & spreadingas directed, dewatering, Shoring, strutting, preparing the bed for the foundation & excluding back filling. |
| 13 | ITEM NO 2Excavation for foundation/pipe trenches in hard murum including removing the excavated material upto a lead of 50 m lifts below, stacking & spreading as directed by engineer incharge normaldewatering preparing the bed for the foundation & excluding back filling.etc complete. |
| 14 | ITEM NO 3Excavation for foundation/pipe trenches in soft rock & old cement &lime masonry foundation asfalt road including removing the excavated material uptoa lead of 50 m beyond the area & lifts as below, stacking as directed by engineer incharge normal , dewatering preparing the bed for the foundation & excluding back filling etc complete. |
| 15 | ITEM NO 4 Providing dry trap/granite querizate/gneiss rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting etc. complete. |
| 16 | ITEM NO 5Providing & laying insitu cement concrete in 1:4:8of trap/granite/quartziegneiss metal for foundation &bedding including belling out water ,formwork compacting & curing etc. complete.M-150 |
| 17 | ITEM NO 6 Providing UCR masonry of trap/granite/quartzite/aneiss stones in cement mortar 1:6 inin foundation & plinth of inner walls or in plinth inner walls or in plinth of external walls including bailing out water manually striking out joints on unexposed faces.& watering complete. |
| 18 | ITEM NO 7 Filling in plinth and floors/ trenches with contractors murum for15 to 20 cm layers including watering and compaction complete |
| 19 | ITEM NO 8 Prov& laying in situC.C. of trap/granite/quartziegneiss metal for RCC work in foundation like raft ,grillage /strip found. &footing of RCC columns and steel stanchon including dewatering formwork compaction / finishing & curing etc. complete.RCC M-150( 1:2:4) |
| 20 | ITEM NO 9 Providing second class BB masonary with conventional IS type bricks in cement mortor (1:6) in superstructure including striking out jointwatering & scaffolding etc complete |
| 21 | ITEM NO 10 Providing and fixing solid core flush door shutter in single leaf 32mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromiumplated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. |
| 22 | ITEM NO 11 Providing & fixing steel window of various szies as per detailed drawing without hot dip zinccoating without ventilator including fabricaton /glazing withplainobsecured glass panels of approved quality thick plates all fixtures and fastening without /with teak wood boxing architraves fininshing without painting etc complete. |
| 23 | ITEM NO 12 Providing&casting in situ.C.C. of trap /granite / quartzite / gneiss metal of approved quality for RCC workas per detailed drawing & designs or as directed by directed engineer in charge including normaldewatering, centering, formwork, compaction finishing the formed surface with C.M. 1:3 of sufficient minimum thickness to give smooth &even surface wherever necessary or roughening if special finish is to be provided & curing etc. complete.RCC M-200( 1:11/2:3)For lintel/ braces/beam |
| 24 | ITEM NO 13 Providing&casting in situ.C.C. of trap /granite / quartzite / gneiss metal of approved quality for RCC workas per detailed drawing & designs or as directed by directed engineer in charge including normal dewatering, centering, formwork, compaction finishing the formed surface with C.M. 1:3 of sufficient minimum thickness to give smooth & even surface wherever necessary or roughening if spe cial finish is to be provided & curing etc. complete. RCC M-150( 1:1 1/2:3)For Slab |
| 25 | ITEM NO 14Providing inernal cement plaster 20 mm thickin two coats in cement morter1:4 in without nerru finish to concrete, brick surface in all positions including scaffolding & curing etc. complete. |
| 26 | ITEM NO 15 Providing tuck pointing with cement morter 1:3for stone masonry work including scaffolding & curing etc. complete. |
| 27 | ITEM NO 16 Providing &laying cement concreteflooring40 mm thick with 1:2:4 cement concrete laid to proper leveland slope in alternate bays including compn filling joints marking lines to give appearance of tiles ,of 30 cm x 30 cm or laid digonally /square etc finishing smooth (with extra cement ) in any color as directedand curing complete |
| 28 | ITEM NO 17 Providing &applying white washin two coats onold/new plasterd or masonary surface & asbestos cement including scaffolding& prepairing thesurfaceby brushing and brooming down complete. |
| 29 | ITEM NO 18 Providing & applyingwashable oilbond distember of approoved color and shade to old & new plasterd surfacein two coats including scaffolding prepairing the surface curng etc complete |
| 30 | ITEM NO 19Providing & fixing in position steel bar reinforcement of various dia. For RCC piles cap footing foundation s slabs / beams / canopyes etc as per detailed design & drawing &schedules including cutting bending ,hooking the bars binding with wires or tac welding and supportingetc. complete. (including cost of binding wire) Tor Steel |
| 31 | PUMPING MACHINERYItem No 1-Submersible Pump set Providing erecting testing and commissioning of submersible pumpset (with Bronze / Stainless steel(CF8M)Impeller) ,capable of discharging requireddischarge at suitable head from all causes as per detailed specification attached. |
| 32 | Item no.-2-Cubical Panel Board-Providing erecting commissiono.ng of cubical type panel board as per specification (Details of panel board as sheet attached) |
| 33 | A)1x 4 x 16 sqmm from MSEDCL topanel boardB) |
| 34 | B)Submersible Cable-Supplying and erecting, Flat flexible submersible cable with, Copper Conductor,PVC insulated, and PVC sheathed.1x3x 2.5 sqm fromstarter to Motor |
| 35 | Item No-3-A-GI Pipe 65 mm dia-Providing erecting jointing 65 mm Dia 6.63 kg/m GI pipe Medium Duty B Class with flanges welded etc. |
| 36 | Item no.4-a-Pressure Gauge-Providing fixing pressure guage with U tube and cock arrangement etc complete.100mm dia. |
| 37 | Item No.5:- Sluice valve 80 mm Dia-Providing,erecting,testing and commissioning C.I. Glandless Sluice valves 80 mm Dia.suitable for working pressure of 10 kg/cm2 with standard non rising spindle, handwheel, cap etc and manufactured as per IS 2906/14846. |
| 38 | Item No.6 :- Reflux valve 80 mm Dia-Providing,laying,jointing commissioningand testing of 80 mm dia.withbypassPN-1 rating C.I.D.F.Reflux valve as per detailed specification attached. |
| 39 | Item No.7:- Kinetic Air valve 40 mm Dia- PN 1 - Providing, ereting, commissioning andtestingof40mm dia.PN-1 rating D.I.Flanged Kinetic Air Valve with isolating valve jointing material etc.as per detailed specification attached. |
| 40 | Item no. 8- Electrification-Providing internal and external electrification \"to the pump house.etc complete. |
| 41 | Item No.9- UFM Meter 80 mm Dia -Providing,installing testing and commissioning of in line battery operated ultrasonic bulk type water meters ISO 4064 with built in data logger and GSM/GPRS modem for transfer of data communication to remote central computer as per working on following conditions and specifications.The meter shall be suitable for 50oC and provided with IP 68 protection class with complete immersion of water.The meter shall have battery life of min.10 years should be able to detect the reverse flow volume and tampering.The accuracy of the meter shall be +/- 1 % of measured value including 36 months guarantee etc complete.( With Simcard and its charges,valid for 36 months) |
| 42 | Item no.10 -- Chamber for Flow meter.-Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B.masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge of 1.2 x 1.2 M internal size and depth upto 1.2 M with precast R.C.C slab cover. |
| 43 | Item No.11-- MS/GIPipes and Specials-Providing and supplying ISI standard MS specials of required thickness with 3coats of approved make epoxy paint ( Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excludingall statutory duties & taxes such as GST levied by GOI & GOM in all respect,inspection charges, transportation to stores / site, and stacking, etc. complete |
| 44 | Item no.12- MS flanges - Providing fabricating erecting MS flanges sleep on typeof requierd size and thickness with both side machined. etc. complete |
| 45 | Item No.13-Earthing-Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification |
| 46 | Item no.14 -Test and Trial-Giving satisfactory test and trial of pumping machinery and allied equipment for one month period. |
| 47 | Rasing mainITEM NO 1Providing and supplying in standard lengths HDPE Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint /compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading /unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. completeHDPE 125 mm dia. PE-100,8 kg/cm2 |
| 48 | ITEM NO 2 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading,stacking excluding GST levied by GOI & GOM in all respect etc. completeSluice Valve with PN-1.0125 mm dia |
| 49 | ITEM NO 3 Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia includ-ing railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984)125 mm dia |
| 50 | ITEM NO 4 Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of ap-proved make and quality of following diameters includ-ing railway freight, inspection charges, unloading from railway wagons, loading into truck, trans-portation upto departmental stores, unloding and stack-ing excluding GST levied by GOI & GOM in all re-spect etc. complete 50 mm dia |
| 51 | ITEM NO 5 Excavation for foundation / pipeline trenches in earth, soils of all types sand,graveland soft murum, including removing the excavated material upto a distance of 50m and lifts as below, stacking and spreading as directed by engineer in charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.lift 0-1.5m |
| 52 | ITEM NO 6 Excavation for foundation / pipeline trenches in hard murum, including removing the excavated material upto a distance of 50m and lifts as below, stacking and spreading as directed by engineer in charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.lift 0-1.5m |
| 53 | ITEM NO 7 Excavation for foundation / pipeline trenchesin soft rock and old cement and lime masonry foundation , asphalt road including removing the excavated material upto the lead of 50m beyond the area & lifts as below,stacking and spreading as directed by engineer in charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete. lift 0-1.5m |
| 54 | ITEM NO 8 Excavation for foundation / pipeline trenches in hard rock by controlled blasting including trimming and levelling the bed by chiselling where necessary and removing the excavated material& stacking it in measurable heaps within a distance of 50m from the area and lifts as below, normal dewatering excluding, back filling etc. complete. lift 0-1.5m |
| 55 | ITEM NO 9 Excavation for foundation / pipeline trenches in hard rock and cocrete road by chiselling ,wedging, line drilling by mechanical means or by all means other than blastingincluding trimming and levelling the bed ,removing the exavated material upto adistance of 50m beyond the areaandlifts as below, stacking as directed by Engineer- in- charge, normal dewatering,excluding back filling etc. complete. HDPE 125 mm dia. PE-100,8 kg/cm2 |
| 56 | ITEM NO 10 Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634Part IIHDPE 125 mm dia. PE-1258 kg/cm2 |
| 57 | ITEM NO 11Lowering laying & jointing in position following C.I D/F Reflux Valves, Butterfly Valves & Sluice including cost of all labour,jointing material, including nut bolts & giving satisfactory hydraulic testing, etc. complete. Sluice Valve /Reflux Valve 100 mm dia |
| 58 | ITEM NO 12 Lowering,laying and fixing in proper alignment and position all types of CI,air valves as directed by Engineer-in charge including cost of conveyance from stores to site of work,cost of all material and giving satisfactory hydraulic testing,etc complete(for all class of valves)50 mm dia |
| 59 | ITEM NO 13 Filling in plinth and floors murum bedding in trenches with approved murum from exavated materials from foundation in 15 cm to 20 cm layers including watering and compaction complete. |
| 60 | ITEM NO 14 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation,surcharging etc.complete |
| 61 | ITEM NO 15 Providing and constructing chamber of clear inside size as below in B.B .masonry 2nd sort in CM(1:6), 225mm thick wall with 12mm thick cement plaster1:3 from inside and CM pointing (1;2) from outside, bedding15mm thick inC.C.( M-100) Including excavation in soft /hard strata etc. complete.including curing as directed, including fixing C.I. M.H. frame and frame cover 0.6 x0.45m ,PCC coping 10 cm. thick and grade m150 etc. complete.clear size :0.90x0.45 .x 0.60 m |
| 62 | ITEM NO 16 providing and fixing in positionair valve shaft including providing and fixing GI medium class or 6mm thick MS pipe shaft 2.70 M long over branch flange of air valve tee,providing PCC block of M-150 concrete 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type desing together with providing and making flanged joints wherever required flanged air valve tee.etc. complete.asper type design and asdirected by Engineer-in-charge for following dia of pipe lines (type design attached)upto 150 mm pipeline |
| 63 | ITEM NO 17 Providing and laying in situ cement concrete of trap/ granite/ quartzite/ gneiss metal for RCC work in foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compacting and curing,finishing etc. complete..M-150 |
| 64 | ITEM NO 18 Bulk MetersRemovable mechanism type Bulk water meter as per ISO 4064 ( without remote reading facility) Providing,installing and giving satisfactory field testing of bulk water meter,horizantal inferential multijet type with magnetic drive and dry dial suitable for ambient 50* c temperature duly sealed against tampering complete with flanges at both ends and confirming to class B as per ISO 4064 along with manufacturers test certificate and guarantee certificate,including cost of all materials and labour etc.with EEC / OIML.MID certification for abroad meter and FCRI for india including 36 months guarantee etc. complete150 mm dia. |
| 65 | ITEM NO 19Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. |
| 66 | E.S.R ITEMNO :- 1Designing (aesthetically ) and consrtucting RCC elevated service reservoirof following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5m center to center for ESR having capacity upto 500 cum. and not more than 6m c/c for ESRs having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling desposing off the surplus stuff within a lead of 50m, all labour and material charges including lowering , laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangement as per departmental design,providing and fixing accesories such as MS.ladder,CI manhole frame and covers, water level indicators, lightening conductor, GI pipe railing around walkway and top slab, providing spiral staircase from ground level to roof level,MSgrill gate of 2m height with locking arrangement of approved designB.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of cement paint to the structure including roof slab epoxy painting to internal surface & anti termite treatment for underground parts of the str.and giving satisfactory water tightness test as per i.s. code, the job too includes painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in - charge.a) 50000 lit. ESR. staging ht.12mupto 50000 liters add for10000 lit |
| 67 | add 5 % sesmic zone |
| 68 | add 7.5 % for raft |
| 69 | ITEM NO.2 Providing and supplying ISI standard CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to stores, unloading etc. complete as directed by Engineer-in-charge 100 mm diaC.I.Pipes |
| 70 | ITEM NO.3Errecting,hoisting in position and jointing ,testing M.S./C.I. D/Fpipes and specials in verticalposition including cost of alljointing materials (rubber packing,nut bolts,etc.),labour, scaffolding, hydraulic testing etc. complete. 125 mm diaC.I.Pipes |
| 71 | 100 mm dia.C.I.Pipes |
| 72 | ITEM NO.4 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.150 mm dia. Sv & washout |
| 73 | 100 mm dia. Sluice Valve |
| 74 | ITEM NO.5 Providing and supplying ISI standard CI flanged / S& S specials excluding GST levied by GOI & GOM in all re-spect including railway freight, insurance, unloading from railway wagon, loading into truck transport to departmen- tal store, unloading stacking etc. complete |
| 75 | ITEM NO.6Providing & FixingM S gate 2.5 m.wide or compound with 40mm dia, GI. pipe, aproud grill work, rcc m-150 side pillers 25cm x 45cm x 2.5m.higeth, foundation,finishing, painting, etc, complte. |
| 76 | DistributionsystemITEM NO 1 providing and supplying in standard lengthsPolyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointingmaterial like mechanical connector i. e. thread /insert joint / quick release coupler joint /compression fitting joint or flanged jointexcluding coupler/specials, includingtransportation and freight charges, inspectioncharges, loading / unloading charges,conveyance to the departmental stores &stacking the same in closed shade dulyprotecting from sunrays & rains, excluding GSTlevied by GI & GOM in all respect etc. complete.Note:- PVC. Pipes shall be as per latest ISSpecifications Also HDPE pipes upto 140 mmDia shall be in coil formA.) PE-100 a) 6 Kg/Sq. cm : \"Provide 180mm Dia. PVC 6 Kg/cm2PE 100 |
| 77 | Provide 90 mm Dia. PVC 6 Kg/cm2PE 100 |
| 78 | ITEM NO 2 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading,stacking excluding GST levied by GOI & GOM in all respect etc. complete left0-1.5 mmSluice Valve with PN-1.0 |
| 79 | ITEM NO 3Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia includ-ing railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) |
| 80 | ITEM NO 4 Excavation for foundation / pipeline trenches in soft soils and all types of soils, including removing the excavated material upto a distance of 50m and lifts as below, stacking and spreading as directed by engineer in charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.Lift 0 to 1.5 m |
| 81 | ITEM NO 5 Excavation for foundation / pipeline trenches in hard murum, including removing the excavated material upto a distance of 50m and lifts as below, stacking and spreading as directed by engineer in charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.Lift 0 to 1.5 m |
| 82 | ITEM NO 6 Excavation for foundation / pipeline trenchesin soft rock and old cement and lime masonry foundation , asphalt road including removing the excavated material upto the lead of 50m beyond the area & lifts as below,stacking and spreading as directed by engineer in charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete. Lift 0 to 1.5 m |
| 83 | ITEM NO 7 Excavation for foundation / pipeline trenches in hard rock by controlled blasting including trimming and levelling the bed by chiselling where necessary and removing the excavated material& stacking it in measurable heaps within a distance of 50m from the area and lifts as below, normal dewatering, back filling etc. complete. Lift 0 to 1.5 m |
| 84 | ITEM NO 8 Excavation for foundation / pipeline trenches in hard rock and cocrete road by chiselling ,wedging, line drillingby mechanical means or by all means other than blasting controlled including trimming and levelling the bed ,removing the exavated material upto adistance of 50m beyond the areaandlifts as below, stacking as directed by Engineer- in- charge, normal dewatering,excluding back filling etc. complete.lift 0-1.5m |
| 85 | ITEM NO 9 Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634Part II\"Provide 140mm Dia. PVC 6 Kg/cm2PE 100 |
| 86 | Provide 90mm Dia. PVC 6 Kg/cm2PE 100 |
| 87 | ITEM NO 10Lowering laying & jointing in position following C.I D/F Reflux Valves, Butterfly Valves & Sluice including cost of all labour,jointing material, including nut bolts & giving satisfactory hydraulic testing, etc. complete. |
| 88 | ITEM NO 11Filling in plinth and floors murum bedding in trenches with approved murum from exavated materials from foundation in 15 cm to 20 cm layers including watering and compaction complete. |
| 89 | ITEM NO 12Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation,surcharging etc.complete. |
| 90 | ITEM NO 13 Providing and constructing chamber of clear inside size as below in B.B .masonry 2nd sort in CM(1:6), 225mm thick wall with 12mm thick cement plaster1:3 from inside and CM pointing (1;2) from outside, bedding15mm thick inC.C.( M-100) Including excavation in soft /hard strata etc. complete.including curing as directed, including fixing C.I. M.H. frame and frame cover 0.6 x0.45m ,PCC coping 10 cm. thick and grade m150 etc. complete.clear size :0.90x0.45 .x 0.60 m |
| 91 | ITEM NO 14 Providing and laying in situ cement concrete of trap/ granite/ quartzite/ gneiss metal for RCC work in foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compacting and curing,finishing etc. complete..M-150 |
| 92 | ITEM NO 15Bulk Meters Removable mechanism type Bulk water meter as per ISO 4064 ( without remote reading facility) Providing,installing and giving satisfactory field testing of bulk water meter,horizantal inferential multijet type with magnetic drive and dry dial suitable for ambient 50* c temperature duly sealed against tampering complete with flanges at both ends and confirming to class B as per ISO 4064 along with manufacturers test certificate and guarantee certificate,including cost of all materials and labour etc.with EEC / OIML.MID certification for abroad meter and FCRI for india including 36 months guarantee etc. complete150 mm dia. |
| 93 | ITEM NO 16 Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position..\"Provide 90mm Dia. PVC 6 Kg/cm2PE 100 |
| 94 | \"Provide 140 mm Dia. PVC 6 Kg/cm2PE 100 |
| 95 | FHTC CONNECTIONS AS PER DEPARTMENT ORDER |
| 96 | TRIAL & RUN Commissioning, running andmaintaining the scheme to quantities,rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and for regional scheme, together with training of personnel spared by MJP / Local Body and handing over the scheme to Local Body after completion of the above period as directed byEngineer-in-charge.Note : Required chemicals to be supplied by Department free of cost and electricity bill willalso be paid by the Department For single village without WTP[MJP SSR 2021-22/232/1a ] |
| 97 | Add 18 % GST |
AI Tender Summary
Tender Timeline
Sep 07, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedSep 20, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 21, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender