Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #33839360

Electrification Work Of Implements Shed For The Development Of Infrastructure Facilities At Rrss Oaz Manikchak E

Issued by Boards / Undertakings / PSU · manikchak, West Bengal
Tender Value
1.75 Lakhs
Estimated cost
Bid Submission
27 Sep 2022
0 days left
EMD
3515
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
manikchak → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Electrification Work Of Implements Shed For The Development Of Infrastructure Facilities At Rrss Oaz Manikchak E

BOQ

Name of Work: Electrification work of Implements Shed for the Development of Infrastructure Facilities at RRSS (OAZ) Manikchak under U.B.K.V, Pundibari, Cooch Behar. (Electrical Work)
Sl. No. Item Description
1Distribution wiring in 1.1 KV, 3x1.5 sq.mm. single core stranded \"FR\" PVC insulated& unsheathed copper wire (Finolex, Havell’s) in19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light /fan / ex-haust fanpoints with Modular type switch ( Legrand) fixed on Modular GIswitch boaed with top cover plate flushed in wall incl. mending good damages to flushed in mending n good damages yo original finish. Total points -8 nos ( Ceiling fan -3 nos, Tube light - 05 nos.) Average length- 12 mtr.
2Distribution wiring in3x1.5 sq.mm. single core stranded \"FR\" PVC insulated& unsheathed copper wire (Finolex, Havell’s) inin 19 mm bore, 3 mm thick polythene pipe complete with allaccessories embedded in wall to 240 V,6A 3/5 pin plugpoint incl. S& F 240 V, 6A , 3/5 pin Modular type Socket & switch ( Legrand ) fixed on Modular GIswitch boaed with top incl. earth continuity wire with Modular top cover plate flushed in wall incl. mending good damages to original finish. On boardsocket
3S and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Finolex, Havell’s) of the following sizes inthe prelaid polythene pipe and by the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.a) 3x1.5 sq.mmfor additional 6 Amp. Plug and SPN DB to Switch board ,
4b) 2x 2.5 +1x1.5 Sq mm forComputer and power points,
5Fixing only single LED tube lightfitting suspended 25 -30 cm bellow the ceiling with 2 No 20 mm dia EI condit (14 SWG) supports incl. S&F EI conduit,and complete with all accessories directly onceiling through U type iron clamp and suitable size of MS fastene and S&F 3x1.5 sq mm flexibale copper wire of 1.5 mt .
6Extra for suspention additional 2 no 20 mm dia EIconduit (14 SWG)supports & necy. PVC insulated wire and painting etc. as required by 2x1.5 mm flexible wire of 1.10 mt. length.
7Fixing of240 volt, 1200 mm sweepceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 3x1.5 sq.mm. flexible copper wire.
8S & F. 240V, 2 Modular socket type fan regulator (Step type) (Crabtree) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
9S & F. MS fan clam of two piece type for RC ceiling fabricated from 40 mm x 9 mm MS flat incl. making good damages to building roof with satisfactory finishing and painting.
10Supplying and fixing 63 amp,4 way double door HTPN MCB DBwith IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and painting for AC, SPNDB and Geyser.(Make- Legrand )
11Supplying and fixing 415 V63 A,4 pole MCB Isolator on din rail of existing DBs and necessary connection.( Legrand)
12Supplying and fixing 415 V32 A,4 pole MCB Isolator on din rail of existing DBs and necessary connection.( Legrand)
13S & F. 10-32 amp, 240V SPN MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Legrand). For HTPN MCB DB
14Supplying and fixing double-door (2+4) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Legrand)
15S & F. 240 volt, 40 amp. MCB DP Isolator on din rail of existing DB and necessary connection ( Legrand).
16S & F. 240 volt, 16 amp. MCB DP Isolator on din rail of existing DB and necessary connection ( Legrand).
17S & F. 10-32 amp, 240V SP MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Havell’s). For SPN MCB DB.
18Supply & Fixing 240 V, 6/16 A, 3/5 pin Modular type plug socket (Legrand) with 16A Modular type switch, without plug top on GI Modular type switch board with top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. forpower points.
19Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooksincl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. 19 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire.
20Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooksincl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.. 25 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire
21Laying of one No. cable 3.5 core 25sqmm in underground trench 460mm wide x 760mm average depth, with brick pro tection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed from proposed main panel at proposed seed godown at proposed HTPN MCB DB at proposed implement shed.
22Laying of followingcablesafter cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish.a) 4 core16 sqmm at an average depth of 75 mm in floor/pavement/wall etc.from HTPN TO 4 poleMCBDB.
23b) 2 core16 sqmm at an average depth of 75 mm in floor/pavement/wall etc.from HTPN TO SPN MCBDB.
24S&F compression type gland complete for following XLPE/PVC armoured cables.3.5 core 25 Sq. mm
254 core 16 Sq. mm
262 core 16 Sq. mm
27Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.3.5 core 25 Sq. mm
284 core 16 Sq. mm
292 core 16 Sq. mm
30Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
31Earthing with 50 mm dia. ISI medium GI pipe 3.64 mm thick x 3.04 mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 mts. long), 13 mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia. GI pipe protection (1 mt. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mts. below the ground level.2 nos for existing panel and rest for proposed panel
32Supplying and fixingMCB SS enclosure with IP-20/30 protection, powder coatedMCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachmen. Make- Legrand.a) 2 way for operation of security light. .
33b) 4 way for operation of security light. .
34Connecting the equipments to earth busbar including S & F. 8 SWG copper solid wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.Earth wire should beconnected earth pit to all bushbar and earth bus bar to VTPN, HTPN, SPN MCB DB etc..
35Supply of 240 volt,20 watt single LED tube light fittings (Cat. No – Frame – Crompton ECO – model – DIJB12L-T8-20, Tube – Crompton – Secure -model – LTT8-20 or equivalent Havells, Philips).
36Supply ofXLPE/ PVC ArmouredAluminium cable (GLOSTER, CRYSTOL, Havells)..1.1 kv grade, 3.5 core ,25 sq mm XLPE/PVCarmoured aluminium cable,
371.1 kv grade, 4 core ,16 sq mm XLPE/PVCarmoured aluminium cable
381.1 kv grade, 2 core ,16 sq mm XLPE/PVCarmoured aluminium cable.
39Supply of 230volt, 1200 mm sweep , AC ceiling Fan ( Orient - Summer King, SummerCool, Summer Breeze,)

AI Tender Summary

OUR REF NO 33839360
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.75 Lakhs
LAST DATE 27-09-2022
Authority
Authority Name Uttar Banga Krishi Viswavidyalaya
Work Description Electrification Work Of Implements Shed For The Development Of Infrastructure Facilities At Rrss Oaz Manikchak E
Basic Detail
Tender No NIeT-03/2022-23
Bidding Type Tender
Location
City manikchak
State West Bengal
Key Dates
Publish Date 07 Sep 2022
Submission Date 27 Sep 2022
Open Date 29 Sep 2022
Finance
Tender Value 1.75 Lakhs
Tender Fee 500
EMD 3515
Exemption Not Available
Document List
250a327c-390f-4256-9d3e-e8f9332d140e.html
BOQ_791230.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 27, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 29, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

250a327c-390f-4256-9d3e-e8f9332d140e.html

xls

BOQ_791230.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders