Special Repairs To Drain And Sewage Lines In Domestic And Special Repairs To Drain And Sewage Lines In Domestic And Technical Area, Special Repair / Replacement Of Amf, Apfc Panel And Dg Set, Provision Of Prepaid Meters At Omqs And Smqs And Provision Of , tezpur-Assam

Military Engineer Services-MES has published Special Repairs To Drain And Sewage Lines In Domestic And Special Repairs To Drain And Sewage Lines In Domestic And Technical Area, Special Repair / Replacement Of Amf, Apfc Panel And Dg Set, Provision Of Prepaid Meters At Omqs And Smqs And Provision Of . Submission Date for this Tender is 21-09-2022. Diesel Generators Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

33827738
Corrigendum : Special Repairs To Drain And Sewage Lines In Domestic And Special Repairs To Drain And Sewage Lines In Domestic And Technical Area, Special Repair / Replacement Of Amf, Apfc Panel And Dg Set, Provision Of Prepaid Meters At Omqs And Smqs And Provision Of
Open Tender
Indian
Assam
tezpur
21-09-2022

Tender Details

Special Repairs To Drain And Sewage Lines In Domestic And Special Repairs To Drain And Sewage Lines In Domestic And Technical Area, Special Repair / Replacement Of Amf, Apfc Panel And Dg Set, Provision Of Prepaid Meters At Omqs And Smqs And Provision Of Split Type Ac In Various Locations

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 73000.0 /-
Tender Value
INR 36.50 Lakhs /-

BOQ Items

Name of Work:SPECIAL REPAIRS TO DRAIN AND SEWAGE LINES IN DOMESTIC AND TECHNICAL AREA,SPECIAL REPAIR/REPLACEMENT OF AMF,APFC PANEL AND DG SET PROVISION OF PREPAID METERS AT OMQs AND SMQs AND PROVISION OF AC IN VARIOUS LOCATIONS AT AF STN TEZPUR UNDER GE (AF) TEZPUR.
Sl. No. Item Description
1Site clearance in soft/loose soil,complete all as specified and directed.
2Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil , complete all as specified and directed.
3Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
4Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and directed.
5Cleaning of existing drains,channels and culvert beds by taking out silts, sludge,mud,debries etc.for free flow of storm water including removingsilts, sludge,mud,debries etc to a distancen exc 50 m and depositing where directed at a leveln exc 1.5m above the starting point,complete all as specified and as directed.
6Dismantling of brick (laid flat or on edge) in floors, channels, kerbs, approns, etc. (each layer) laid, bedded and pointed in any mortar complete all as directed.
7Removing mortar from and cleaning bricks,stackingfor measurement including all extrahandling, removing and disposing off rubbishes complete all as directed.
8Materials and Labour for plain cement concrete (1:4:8) Type D-2 using 40 mm graded aggregate,in foundations, filling and mass concrete, complete all as specified and directed.
9Materials and Labour for plain cement concrete (1:3:6) Type C-2 using 40 mm graded aggregate,in foundations, filling and mass concrete including demolition of existing cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for,complete all as specified and directed.
10Materials and Labour for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.
11Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work and including demolition of existing cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for,complete all as specified and directed.
12Materials and Labour for plain cement concrete (1:3:6) type C2 using 40 mm graded aggregate as in surface channels and drains including demolition of existing cement concrete(un reinforced) of any description and in any position not otherwise specifically provided for,complete all as specified and directed.
13Materials and Labour Extra for forming fair finishing to surfaces channels/drain 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, etc complete all as specified and directed.
14Add or deduct from serial item No 13 here in before for each 25 mm girth or part thereof over or under 30 cm for forming fair finished drain or channel in cement concrete, using extra cement including forms, moulds, mitered /stopped ends etc. complete.
15Materials and Labour forproviding precast reinforced cement concrete (1:2:4) type B1 using 20 mm graded aggregate, in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and setting in mortar (1:4) complete with joints to match including demolition of existing reinforced cement concrete(reinforcement cut as required to facilitate demolition) in landings,cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces,all as specified and directed.Note:- Reinforcement will be measured and paid seperately.
16Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:4), including demolition of existing brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches,pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles,complete all as specified and directed.
17Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
18Materials and Labour for,bricks,sub class B,laid flat, in floors,old size bricks,bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3),complete all as specified and directed.
19All as per Serial Item No.18 Here in Before but except bricks. Note:- Old Bricks obtained from Serial Item No 6 and 7 Here in Before shall be re-used.
20Materials and Labour for,bricks,sub class B,laid on edge,in floors,old size bricks,bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3),complete all as specified and directed.
21All as per Serial Item No.20 Here in Before but except bricks. Note:- Old Bricks obtained from Serial Item No 6 and 7 Here in Before shall be re-used.
22Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface other than fair face of brickwork or concrete surface in wall,complete all as specified and directed.
23Materials and Labour for rendering 10 mm thick, cement plaster, in cement mortar (1:4) mixed with waterproofing compound as per manufacturer"s instructions on fair faces of brick work or concrete surface in walls and finishing surface even and smooth without using extra cement,complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
24Supply Only, integral water proofing compound,complete all as specified.
25Materials and Labour for rendering 10 mm thick, cement plaster, in cement mortar (1:4) on fair faces of brick work or concrete surface in walls including taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc.,complete all as specified and directed.
26Raking out joints/ pointing to brick work built in cement or cement lime mortar in walls or to bricks on edge in floors,surface channels, roofs, etc.,complete all as directed.
27Material and Labour for,flush pointing to brick on edge pavings in cement mortar (1:4),complete all as specified and directed.
28Material and Labour for,flush pointing to bricks laid flat or brick tiles in pavings in cement mortar (1:4),complete all as specified and directed.
29Material and Labour for,preparing new surfaces on walls,plastered or unplastered and applying two coats of cement based paint over and including priming with alkali resistant priming paint,complete all as specified and directed.
30Supply, laying, jointing and testing of,150 mm internal dia.,salt glazed stoneware drain pipes, conforming to IS 651:2007, class ‘SP1’, laid in trenches and jointed including demolition and breaking up existing drain pipes (Salt glazed ware, AC or reinforced concrete), 150 mm internal diameter,set in cement mortar,complete all as specified and directed.
31Materials and Labour for,150 mm bore, Class SN 8, SDR 34, ISI Marked(IS 15328) Unplasticised Non Pressure Poly Vinyl Chloride (PVC-U) pipes for use in underground drainage and sewarage system,single socketed, with elastometric sealing ring joints,laid in trenches or in floorsincluding demolition and breaking up existing drain pipes (Salt glazed ware, AC or reinforced concrete), 150 mm internal diameter,set in cement mortar, complete all as specified and directed.
32Materials and Labour for,200 mm bore, Class SN 8, SDR 34, ISI Marked(IS 15328) Unplasticised Non Pressure Poly Vinyl Chloride (PVC-U) pipes for use in underground drainage and sewarage system,single socketed, with elastometric sealing ring joints,laid in trenches or in floorsincluding demolition and breaking up existing drain pipes (Salt glazed ware, AC or reinforced concrete), 150 mm internal diameter,set in cement mortar, complete all as specified and directed.
33Materials and Labour for,concrete bed to 150 mm bore drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested; in plain cement concrete (1:3:6) type C1 using 20 mm graded aggregate,complete all as specified and directed.
34Materials and Labour for,concrete bed to 200 mm bore drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested; in plain cement concrete (1:3:6) type C1 using 20 mm graded aggregate,complete all as specified and directed.
35Materials and Labour for,cutting into existing manholes for connecting new drains,internal diameter of pipe 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required,complete all as specified and directed.
36Materials and Labour for,cutting into existing manholes for connecting new drains,internal diameter of pipe 200 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required,complete all as specified and directed.
37Disconnection of existing APFC Panel of any capacity/rating, form all incoming and outgoing electrical connections,checking serviceability of each components viz. capacitors,contactors,relays,MCB"s, MCCB"s, indicator lights, display meters, PF controller etc., replacement of burnt out internal wirings with with suitable size FRLSH PVC insulated multistranded copper conductor wires,replacement of defective lugs,thimbles etc.,replacement of defective parts,through cleaning of panel both internally and externally, re interconnection of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning, complete all as specified and directed.Notes:-(i) The work shall be carried out through Authorised Original Equipment Manufacturer"s Service Centre Engineers or through OEM Certified Agencies as approved by the Engineer in Charge.(ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
38Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 5 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
39Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 7.5 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
40Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 10 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
41Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 12.5 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
42Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 15 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
43Supply Only, power factor correction capacitors,box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 20 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
44Supply Only, power factor correction capacitors,box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 25 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
45Supply Only,capacitor duty contactors, type MO C5, built in auxillary contacts 1NO, rating 5 kVAr, 440 V, 3 phase, 50 Hz all as specified. [Cat No.CS96127 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
46Supply Only,capacitor duty contactors, type MO C8.5, built in auxillary contacts 1NO, rating 8.5 kVAr, 440 V, 3 phase, 50 Hz all as specified. [Cat No.CS96320 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
47Supply Only,capacitor duty contactors, type MO C12.5, built in auxillary contacts 1NO, rating 12.5 kVAr, 440 V, 3 phase, 50 Hz all as specified. [Cat No.CS96321 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
48Supply Only,side mounting add on auxillary contacts 1NO + 1NC suitable for capacitor duty contactors,type MO C 3-100,all as specified. [Cat No.CS94580/CS94581/CS94582/CS94583 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
49Supply Only,APFC controller for contactor switching with 1 CT input 1/ 5 Amp, 415 V, 8 steps (For Contactor Switching) all as specified. [Cat No.CS90902OOOO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
50Supply Only,LED Indicator 16 mm with power consumption < 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC, colour Red/Green/ Yellow/Blue all as specified. [Cat No. SIL of Make “L&T” or equivalent Model of Make HPL/ AE]
51Supply Only, 3 Phase LED Ammeter, Accuracy Class 1.0, Aux supply 80-300 VAC, CT secondary site selectable 1A / 5A, flush mounting 96 x 96 mm, with inbuilt selector switch all as specified. [Cat No. WL131010OOOO of Make “L&T” or equivalent Model of Make HPL/ AE ]
52Supply Only, 3 Phase LED Voltmeter, Accuracy Class 1.0, Input voltage measurement range 50-550 VAC (P-P), Aux supply 80-300 VAC, CT secondary site selectable 1A / 5A, flush mounting 96 x 96 mm, with inbuilt selector switch all as specified. [Cat No. WL132010OOOO of Make “L&T” or equivalent Model of Make HPL/ AE]
53Supply Only, miniature circuit breaker (MCBs) single pole and neutral, 240 Volts,10KA, "C" curve,6 to 32 Amps, complete all as specified. [Cat No. BB20060C/BB20100C/BB20160C/BB20200C/BB20250C/ BB20320C of Make L&T or equivalent Model of Make Legrand/ Hager/Seimens/GE/ Schneider/ABB]
54Disconnection of existing AMF Panel of DG Sets of any capacity/rating (62.5-500KVA), form all incoming and outgoing electrical connections, checking serviceability of each components viz. capacitors, contactors, relays, timers, MCB"s, MCCB"s, indicator lights,display meters,controller etc.,replacement of burnt out internal wirings with with suitable size FRLSH PVC insulated multistranded copper conductor wires,replacement of defective lugs,thimbles etc.,replacement of defective parts,through cleaning of panel both internally and externally, re interconnection of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning,complete all as specified and directed. Notes:-(i) The work shall be carried out through Authorised Original Equipment Manufacturer"s Service Centre Engineers or through OEM Certified Agencies as approved by the Engineer in Charge.(ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
55Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 70, AC-3 rating 70 Amps and AC-1 rating 100 Amps,complete all as specified. [Cat No.CS97076 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
56Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 80, AC-3 rating 80 Amps and AC-1 rating 100 Amps,complete all as specified.[Cat No.CS97077 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
57Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 140, AC-3 rating 140 Amps and AC-1 rating 160 Amps,auxillary contacts 2 NO + 2 NC,complete all as specified.[Cat No.CS94138 of Make “L&T” or equivalent Model of Make Siemens/ Schneider/ABB.]
58Supply Only, 4 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1,Type MCX 32,AC-1 rating 160 Amps,auxillary contacts 2 NO + 2 NC,complete all as specified.[Cat No.CS97020 of Make “L&T” or equivalent Model of Make Siemens/ Schneider/ABB.]
59Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 225, AC-3 rating 225 Amps and AC-1 rating 300 Amps,auxillary contacts 2 NO + 2 NC,complete all as specified.[Cat No.CS94140 of Make “L&T” or equivalent Model of Make Siemens/ Schneider/ ABB.]
60Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 400, AC-3 rating 400 Amps and AC-1 rating 425 Amps,auxillary contacts 2 NO + 2 NC,complete all as specified. [Cat No.CS94144 of Make “L&T” or equivalent Model of Make Siemens/ Schneider/ ABB.]
61Supply Only,AMF panel battery charger with short and reverse polarity protection,single phase,output voltage 12 Volts DC,charge current 10 Amps,as per OEM"s specifications.
62Supply,laying, jointing and testing of industrial cable,PVC insulated and FR PVC round sheathed with copper conductor (flexible),nominal area of conductor 2.5 sq mm, 8 core, 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable,complete all as specified and directed.
63Supply and fix in repair,electronic meters temper proof LCD display withpolycarbonate cover single phase 230 V,5-30 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH,complete all as specified and directed. [Cat No.WM101BC5DL0BOX of Make L&T/"Liberty 200" of Make Secure Meters or equivalent models of the Makes mentioned in the particular specifications.]Note:- The existing energy meter(s) shall be deposited by the Contractor in the store yard of AGE E/M (AF) Tezpur and receipt voucher obtained.
64Supply and fix in repair,electronic meters temper proof LCD display withpolycarbonate cover 3 Phase 415 V,10-60 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time,current reading, load, PF,voltage and KWH,complete all as specified and directed.[Cat No.WR301BC7D10 of Make L&T/"Secure Sprint-350" of Make Secure Meters/Cat No. 30002568 of Make Schnieder or equivalent models of Makes mentioned in the particular specifications.]Note:- The existing energy meter(s) shall be deposited by the Contractor in the store yard of AGE E/M (AF) Tezpur and receipt voucher obtained.
65Supplying and fixing,smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board /panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition,complete all as specified and directed.[Cat No.WM101BC7ASPREPAIDB of Make L&T/ "Liberty+single-phase prepayment meter" of Make Secure Meters or equivalent models of Makes mentioned in the particular specifications.]
66Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG,capable to define for tariff slabs, happy hours and holiday definition,complete all as specified and directed. [Cat No.WR300BC7ASPREPAIDB of Make L&T/"Liberty 3P Three phase prepaid electricity meter" of Make Secure Meters or equivalent models of Makes mentioned in the particular specifications.]Notes:-(Applicable for Serial Item No. 65 and 66)(i) The cost for taking down existing meter(s),connecting the new meter(s) to the existing metering system and other connected item(s) including provision of 3 pair(s) of 0.5 sqmm size annealed copper connecting wire for connection between meter(s) and consumer interface unit(s) etc. required for installation,testing and commissioning of the meter(s) as per OEM"s reccommendations including necessary training to MES personnel(s) for manning of the system shall be deemed to be included in the quoted rate.(ii) The existing energy meter(s) shall be deposited by the Contractor in the store yard of AGE E/M (AF) Tezpur and receipt voucher obtained.
67One time vending charges for a period of 01(one) year for the dual source prepaid energy meter(s), including providing facilities to access all necessary software(s),data base defining,mapping of consumer(s), running of the vending system etc. from the OEM (Original Equipment Manufacturer) for monitoring and enabling uploading of payments in the meters by the end user(s),complete all as specified and directed.
68Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
69Supply,installation,testing and commissioning of Inverter type Split AC unit 1.5 Ton capacity, indoor & outdoor units with cordless remote control for indoor unit and with in built air ioniser and plasma filter for better indoor air quality with BEE 5 star rating and EER 3.2,operated in single phase AC supply, including necessary interconnection refrigerent copper tubing of required dia. & length duly insulated,condense water PVC rigid piping not less than 19 mm external dia.and 2 mm wall thickness,outdoor unit mounting bracket made out of mild steel including leakage testing duly filed with CFC free refrigerant for fixing of compressor as upto the required pressure as per manufacturer"s instructions and including necessary civil work i.e. making hole, PCC work, MS stand/bracket,duly painted and connection etc., complete all as specified and directed. Notes:- (i) AC refrigerant shall be Non CFC. (ii) Quoted rate shall be deemed to be inslusive of the cost of pipes,cables for connection of outdoor and indoor unit and nothing extra shall be admissible on this account.
70Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring,complete all as specified and directed.
71Supply and Fix,single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V, complete all as specified and directed. [Cat No. 5078 11 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/ GE/ Schneider/ABB]
72Supply and Fix,voltage stabilizer for automatic operation, single phase, naturally air cooled designed for input voltage variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5%, capacity 4 KVA,complete all as specified and directed.
73Supply and Fix,Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts,8 way, with 200 Amps rated bus bar, Single Pole & Neutral,complete all as specified and directed.[Cat No. 5076 11 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
74Supply and Fix, miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA,"C" curve, 6 to 32 Amps complete all as specified and directed. [Cat No. 4085 87-4085 95 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/ GE/Schneider/ABB]
75Supply and fix miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA,"C" curve,40 Amps complete all as specified and directed.[Cat No. 4086 18 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/ GE/Schneider/ABB]
76Supply and fix miniature circuit breaker (MCBs) triple pole and neutral,415 Volts,10KA,"C" curve,63 Amps complete all as specified and directed.[Cat No. 4086 83 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/ GE/Schneider/ABB]
77Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
Disclaimer :