Provision Of Infrastructure For Installation Of Asr With Mssr At Ins Hansa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Sep-2022 date amendment Date 14-10-2022
2 06-Oct-2022 dateamendment Date 25-10-2022
3 18-Oct-2022 Date amendment 18 Oct 2022 Date 09-11-2022
4 31-Oct-2022 Date amendment 31 Oct Date 18-11-2022
5 11-Nov-2022 Date amendment 11 Nov Date 30-11-2022
6 17-Nov-2022 Revised BOQ, Sch and Revised pages BOQ 06-12-2022
7 17-Nov-2022 Date amendment 17 Nov Date 06-12-2022
8 22-Nov-2022 Re Revised BOQ, sch and amdt pages BOQ 06-12-2022
9 22-Nov-2022 Date amendment 22 Nov Date 06-12-2022
10 06-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-12-2022

Key Value

Document Fees
INR 3000 /-
EMD
INR 580000.0 /-
Tender Value
INR 5.10 Crore /-

BOQ Items

Name of Work:PROVISION OF INFRASTRUCTURE FOR INSTALLATIONOF ASR WITH MSSR AT INS HANSA
Sl. No. Item Description
1SCHEDULE "A" Part - I (BUILDINGS & STRUCTURES WORKS) Total of Sch-"A" Part-I B/F
2SCHEDULE "A" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) Total of Sch-"A" Part-II B/F
3SCHEDULE "A" PART-III ( INTERNAL ELECTRIFICATION & CONDUIT FOR TELEPHONE/ TV) Total of Sch-"A" Part-III B/F
4SCHEDULE "A" PART-IV (INTERNALWATER SUPPLY) Total of Sch-"A" Part-IV B/F
5SCHEDULE "A" PART-V ( ROAD , HARD STANDING & PATH WAY ) Total of Sch-"A" Part-V B/F
6SCHEDULE "A" PART-VI ( SEWAGE DISPOSAL ) Total of Sch-"A" Part-VI B/F
7SCHEDULE "A" PART-VII ( AREA DRAINAGE ) Total of Sch-"A" Part-VII B/F
8SCHEDULE "A" PART-VIII ( EXTERNAL ELECTRIFICATION ) Total of Sch-"A" Part-VIII B/F
9SCHEDULE "A" PART-IX (EXTERNAL WATER SUPPLY) Total of Sch-"A" Part-IX B/F
10SCHEDULE "A" PART-X ( FIRE ALARM SYSTEM) Total of Sch-"A" Part-X B/F
11SCHEDULE "A" PART-XI ( LIGHTNING PROTECTION ) Total of Sch-"A" Part-XIB/F
12SCHEDULE "A" PART-XII (AIR CONDITIONING) Total of Sch-"A" Part-XII B/F
13SCHEDULE "A" PART-XIII (LIFT ) Total of Sch-"A" Part-XIII B/F
14SCHEDULE "A" PART-XIV ( ARBORICULTURE) Total of Sch-"A" Part-XIV B/F
15SCHEDULE "A" PART-XV ( CABLE DUCT) Total of Sch-"A" Part-XIV B/F
16SCHEDULE "A" PART -XVI(MISCELLANEOUS ITEMS)
17EXCAVATION & EARTHWORK
18Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Notes (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site. (iii) All excavation earthwork covered under Sch "A" part III to part XIV shall be measured and paid under this item.
19INTERNAL ELECTRIFICATION & CONDUIT FOR TELEPHONE & TV
20S & F Area Flood light fitting LED250/260 Watts, energy saving environmental friendly, long life exclusive innovatiive die cast aluminium IP 66 flood light with high power LED as light source suitable for high lighting architectural features or retail spaces FloodTune is easy to use, reliable and cost effective color changing outdoor flood light for creating dynamic lighting effects by just using your smart phone to control lights. . make- WIPRO /HAVELLS /JAQUAR /PHILLIPS (For Top of Radar Tower)
21S & F LED Security/Street light fittings 25 Watt wall mounting type extruded metal/aluminium body,andelectronic LED driver,etc with all accessories internal prewired &including connecting up with 2 core flexible cppper conductor cable with suitable sizeincluding fabricattion,supply & fix GI pipe bracket 25mm dia- 0.9m long & 2 sets of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 25W ssecurity light fitting Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
22S&F Fresh air Exhaust fanof size 230 mm sweepPVCbody complete withlouvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make :Crompton Greaves/ Bajaj/Orient/Havells
23S&F Heavy duty Exhaust fanof size 450 mm sweepmetal body complete withlouvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make :Crompton Greaves/ Bajaj/Orient/Havells
24S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed.-Make :Crompton Greaves/ Bajaj/Orient/Havells
25S & FMCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link,IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913// schneider/ ABB ( main DB)
26Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flatincluding earthingpit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pitcover includingnecessary excavation & earth work complete all as shown in electrical plate No-5 of SSR-2009 (part-I) [ Qty 04 Int Elect + 02 Ext WS + 02 AC
27Supply and fixing of cable tray made up of galvanised perforated sheated size 250mm x 50mmand12 gauge includingfixing duly supported on angle iron 40x40x3 mm made in triangular shape , bracing, support, clamps etcfabricated from structured steel, sections, cutting to required length bent to any shape ,drilling holes, fixed to wall or jointed by means of elect welding complete,and fixingto wall by using galvanised steel anchor fastnar bolt of size 12/16 mm dia.and 100/110 mm long & ,equal distance of 2 meter maximum on wall/floor/through wall crossing and making good the surface as per directions of Engineer in Charge.
28M&L for Chemical earthing with one No of copper earth plate of size 900 x 600 x 5 mm & copper earth strip 32 x 6 mm buried in ground vertically to a depth not less than 3.0 metre below ground level with top edge earth electrode at a depth not less than 2.40 metre deep below ground level including suitable quantity of backfill chemical compound for filling in each pit to cover earth electrode minimum 100 mm all around and electrode shall be jointed with the copper strip of size 32 x 6 mm by exhothermic weldcompletewith earth pit chamber of size 300 x300 mm and RCC cover for demarking the location of earth electrode location.Make of Back Fill Compound: Tercel (Isogel) (Australia)/ Indelec (Xgel) (France)/ ERICO (GEM) (USA)/ LPF (Reslo) (Australia) (Note :- (i) The quantity of Backfill compound and depth of earth pit can be increased by the contractor without any extra cost to Govt. The Contractor shall ensure thatearth resisitance shall be less than 1 ohmson completion andtesting. The testing of each earthingshall be carried outin presence of Engr-in-charge and test results shall be submitted duly signed by all concered while claiming payments.) (ii)Earth strip with protection pipe 50mm GI light grade upto 7.5 meter is deemed to be included in the rates quoted. [ Qty- 4 Int Elect + 4 Ext Elect +
29M & L for Copper strip 32 x 6 mm as earth continuity conductor 600 mm long, duly drilled with 10 mm dia hole in every 50 mm on entire strip for taping earthing ,fixed on wall with PVC insulated back plate/FRP Insulator at 250 mm distance with copper nuts and bolts including anchor fastner pin type complete all as specified and directed.
30Supply & Fix DLP PVC trunking System of size 150 mm x 50 mm complete with all assocessarries like Trunking Cover,, joints , Internal & External angles , Flat angles ,Tee joints,End Cap ,Cable Holding clops & additional assocessries if required , Make Legrand/ABB/ L&T
31M&L for TV socketmodulemetal flushed including flushed Box cover plate Box for 2 way module complete all as specified.
32M&L for telephone jak with modulemetal flushed including flushed Box cover plate Box for 2 way module complete all as specified.
33Supply and lay coexal cable for TV Cabledrawn through conduit
34EXTERNALELECTRIFICATION
35Supply, install, testing and commisioning of Distribution transformerstepdown Level 3 , 11KV0.433KV , Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments , Indoortype double copper wound suitable for 50 Hz system of capacity 200 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in steP of 2.5 %.Losses should be confined to the limits specified as follows: :maximum allowable losses atfull load (100 % ) & Half Load ( 50 % )shall not be exceeded 1.35 % & 0.93 % Respectivly as per GRlHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers shall be supplied with first filling of oil confirming to IS 335 .The transformer shall have both side cable end box with neutral brought out completeall as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications : -
36(a) Lifting lug for transformer and tank.
37(b) Earthing terminal rating and diagram plate.
38(c ) Air release device.
39(d) Oil filling inlet pipe with plug.
40(e) Drain outlet pipe with brass gate valve.
41(f) Conservator tank with oil level indicator
42(g) Silica jel breather
43(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.
44(k) Type of connection Delta/Star
45(l) Type of cooling: Oil and Natural Air.
46(m) Vector group:DYN 11.
47(n) Temperature rise over an ambient of 50 °C maximum.
48(o) Cable end box on both side for HT/LT cables of suitable size.
49(p) Provision of thermometer with pocket.
50(q) Provision of oil and winding temperature gauge.
51Supply, installation, commissioning and testing the following Vacume Circuit breaker 11 KV, 3 phase 50 cycle ( 50 HZ) totally enclosed metal clad switch gear panel factory made, powder coated board with indoor vacuum circuit breaker floormounted with common coppertinned bus bar complete all asspecified ( Incoming For Transformer)
52(a)  One No 630 Amps capacity triple pole metal clad HT control panel totally enclosed extendable pattern air insulated metal clad housing, floor mounting vertically isolated, vermin proof, fully interlocked horizontal draw out type having double isolation features & control device with grounded neutral system and equipped with the following equipment.
53(i)  One set of 3 phase 630 Amps air insulated, tinned copper bus bar with insulated colour coating.
54(ii)    One set of side frame for housing for circuit breaker carriage.
55(iii)   6 Nos630 amps isolators plugs.
56(iv)  One set of mechanical interlock and automatic shutter system,
57(v)    One 630 Amp triple pole 350 MVA rupturing capacity VCB with automatic drop out and manually charged and motor operated spring closed mechanism complete with auxiliary switches, truck mounted draw out, vacume circuit breaker, incorporating mechanical as well as electrical ON/OFF indication, mechanical indication "ON" push button for emergency trip & 30 Volts DC trip coil.
58(vi) One cable box suitable for reception for 95/120 sqmm HT XLPE 3 core under ground cable 11000 volts pressure.
59(vii) 03 Nos double wound current transformer dual ratio 150/100/ 5-5 amps for protection and metering having adequate VA burden and accuracy.
60(viii)  One set of 4 Nos LED lamp for indicate ON/OFF/Trip/charging.
61(ix)  One 3 phase horizontal draw out type voltage transformer 100 VA burden and accuracy mounted on the draw able housing for 11000 volts/ 110 volts with protection fuse.
62(x)    144 mm square type CT operated flush pattern digital amps meter scaled with dual range 0-200amps with three way on/off rotary selector switch.
63(xii)  One set of 3 pole micro processrelay 3 phase over current , earth fault relay MC – 61 CNXMake L&T. suitable for incoming panel.
64(xiii)  One 144 mm squarePT operated flush pattern analog volt meter 0-15 KV scaled operated with and including three way rotary type selector switch.
65(xiv)  OneNo volt coil to trip the VCB on failure of electric supply.
66(xv)  One set of mechanical interlock and automatic shutter gear.
67(xvi)  230 volts AC single phase 80 watt rated strip heater with switch and thermostat space heating.
68(xvii)  Provision of 30 volts DC tripping system with suitable power pack including, siren/ horn alarm and accept switch and over voltage protecting relay.
69(xviii) Provision of motorcharging withAC motor.
70(xvix) Inbuild Power pack 30 v dc to be provided with panel at least for 30 minuite Back Up.
71Supply, installation, commissioning and testing the following Vacume Circuit breaker 11 KV, 3 phase 50 cycle ( 50 HZ) totally enclosed metal clad switch gear panel factory made, powder coated board with indoor vacuum circuit breaker floormounted with common coppertinned bus bar complete all asspecified (For Outgoing)
72(a)  One No 630 Amps capacity triple pole metal clad HT control panel totally enclosed extendable pattern air insulated metal clad housing, floor mounting vertically isolated, vermin proof, fully interlocked horizontal draw out type having double isolation features & control device with grounded neutral system and equipped with the following equipment.
73(i)      One set of 3 phase 630 amps air insulated tinned copper bus bar with color coating.
74(ii)    One set of side frame houring with circuit breaker carriage.
75(iii)   06 Nos 630 amps isolating plugs.
76(iv)  One set of mechanical interlock and automatic safety shutter gear.
77(v)    One 630 Amp triple pole 350 MVA rupturing capacity VCB with automatic drop out and manually charged and motor operated spring closed mechanism complete with auxiliary switches, truck mounted draw out, vacume circuit breaker, incarporating mechanical as well as electrical ON/OFF indication, mechanical indication "ON" push button for emergency trip & 30 Volts DC trip coil.
78(vi)  One rear cable box for reception of one 95/120 sqmm HT XLPE 3 core cable 11 KV pressure.
79(vii) Three nos primary wound current transformer ratio 50/25/ 5-5 amps for the protection and metering having adequate VA burden and averaging.
80(viii)  One set of 4 Nos LED lamps for indicates on/off/trip charging
81(ix)  144 mm square Type CT operated digital amp meter with 3 way rotary switch.
82(x)    One No microprocessor relay 3 phaseover current earth faultrelay MC 61-CNX make : L&T
83(xi)  Provision of DC 30 volts tripping system connected to common siren / horn alarm but with separated reception switch ( accept switch).
84(xii) Provn of motor chargingwith AC motor.
85(xvix) Inbuild Power pack 30 v dc to be provided with panel at least for 30 minuite Back Up.
86NOTE -proposed VCB shall be fixed with exsisting VCB panel at 33 KV Sub Station Hansa, with all necessary extension of busbar chember . Rate is inclusive of extention of busbar chember andincluding making of fixing arrangements ,making suitable size of ductetcall as specified and as directed.
87Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated,indoor type, APFC capacitor bank Panel Board of size as recommended by manufactrer 50 KVAR with 6 steps ( 10+10+10+10+ 5+5)WITH MD-XL CAPACITOR AND MCCB AS INCOMER Automatic Power Factor Correction panel , made out of 2 mm thick CRCA Sheet Dust and Vermin Proof,single door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032., including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installationcomplete all as specified .The panel shall be factory fabricated comprosing of following. Make of pannelL&T/ SCHNEIDER/ABB
88SL NOParticulars
89A INCOMER
90MCCB 125 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & DN2-250D,CAT NO- CM920083OOM1OG- 1 no (Thermal Magnetic Release)
91ROM+SPDR - 1 no
92Auxiliary 1 c/o +TAC 1 c/o- 1 no
931 10 KVAr Capacitor feeder comprising of:- ( 4 Nos. )
9440A, BUSSMANN FUSE- 12 NOS
95Thyristor switching module 10 kVAR, 440V,TSM,LTTSM - 4 NOS
967% Detuned Aluminium Reactor 10 KVAr 440V LTAL,CAT NO-0710B2- 4 NOS
97Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 12.5 kVAr,sutable for 480V
98Push Button ON/OFF -8nos
99Indicating lamps 8 NOS
100Auxiliary Contactor {2NO+2NC}24V DC Coil Voltage MXO-4
1016A DP MCB , C CURVE 4 NOS
10225 KVAr Capacitor feeder comprising of:- (2 Nos. )
10316A, BUSSMANN FUSE 6 nos
104Thyristor switching module 10kVAR, 440V,TSM,LTTSM - 2 nos
1057% Detuned Aluminium Reactor 5 KVAr 440V,LTAL,CAT NO-0712B2-2 no
106Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 7.5 kVAr,sutable for 480V ,LTXL- 2nos
107Push Button ON/OFF -4nos
108Indicating lamps 4 NOS
109Auxiliary Contactor {2NO+2NC}24V DC Coil Voltage MXO- 2
1106A DP MCB , C CURVE 2 NOS
1113. Incomer Metering
112APFC relay 6 stage {BLR CM – 06T MB } -1 NO [230/ 110 V, 1/5A, 50 Hz] [Transistor output+ Single CT sensing + RS 485 MODBUS]
113Digital Voltmeter (3Ph, Class 1) -1 NO
114Digital Ameter (3Ph, Class 1, 5A) -1 NO
115Metering CT --/5A, Class-1- 3 NOS
116SMPS 5A, Input 230V AC Output 24V DC -1 NO
117ON Delay Timer 0-10 Sec.,Coil 24V DC -1 NO
118Auxiliary Contactor {4NO} with 24V DC}-3 NOS
119Auto Manual selector switch -1 NO
120Indicating Lamp(R,Y,B)-3 NOS
1216A SP MCB-3 NOS
1226A DP MCB
1236A FP MCB-1 NO
1248" {EBM NADI} Fan -1 NO
125Supply & installation of indoor Voltage stabilizer with control panel (automatic/servo voltage controller) three phase 50 Hz for "Automatic controlling/Regulating of voltage comprising auto transformer, buck & boost transformer, wiring and terminations all in Copper ( with new filtered and dehydrated transformer oil), servo motor, auto controlled microprocessor based control circuit (Suitable for supply from DG Set also) , auto and bypass arrangement and other fittings & accessories as under:- (i) S&F digital type volt meter to read input/output voltage (0-415)V,Ammeter suitable CT"s andFrequency meter, Mains/Low/High limit indicators, Manual increase/decrease push button, Auto/Manual mode control switch and output adjustment with the following specifications:- (a) Rated Capacity 200 KVA Copper wound Oil cooled (b) System 03 Phase , 50Hz, AC Supply (c) Input Voltage 300V to 480 V (d) Output voltage Set 415V+1% speed of correction 8V/Sec (e) Type of Cooling Naturally Oil Cooled (f) Type of System Unbalanced (g) Operating Temp 15 to 60° C (h)High/Low Voltage cut off feature (j)Protection Under Voltage, Over Voltage, Phase Failure, Reverse phase protection, Over Load protections. (k) Over Voltage cut off (l) Two digital Volt meters (For Incoming and outgoing)with inbuilt selector switch (r)One digital Ammeter(inbuilt selector switch) with suitable CTs of Class 1.0 (s) end Terminations with suitable bus bar for terminating 3.5 Core x 240 Sqmm with the end terminationbox along with suitable glands for cables complete. (t) Wheels for uni directional movement
126Supply, Installation, test and Commissioning, factoryfabricated LT panel board, type tested by CPRI /Authorised Govt. Agencies ,confirming toIEC 60349-1 & 2,up to 400 Amps incommer OR confirming toIEC 61349-1 & 2, above 400 Amps incommer,LT panel board made out of 2 mm thick GI Sheet multifold design, chemically treated surface with multi tank process powder coating,indoor modular type,dust free ,Vermin Proof , totally enclosed with Confirming to IP 43 for indoor panel & Confirming to IP 54 for outdoor panel ,single door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Galvanised iron Angle Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following :– Make of panel board-L&T / ABB / Schneider/Seimens or by their authorised channel partners duly authenticated by th company. (Main Panel-1 )
127INCOMING:-
128(a)MCCB 400 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&Tcat no- CM98403OOROOG /Legrand ./schneider.- 1 no
129(b) Aluminium TPN Busbar 600 Amps - 1 Set
130OUTGOINGS:-
131(a) MCCB 320 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&Tcat no- CM98401OOQOOG /Legrand /schneider- 2 no (STABILIZER & SPARE)
132(b) MCCB 125 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu L&T CAT NO-SL98653OOOO/ LEGRAND CAT NO-420086 /equivalent of ABB- 1 nos ( APFC)
133(c) Elecronic energy trivactor meter,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240v AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), with optical port,deficiency metering with either phase/netral current, IP 51 protection, as per IS13779,make of meter -L&T model no- ER300P & Cat no-WR300BC52RSof L&T or equivalant of secure
134(d) CT 400X5 Amps 3 nos ( for Meter)
135( e) Ammeter Class-1,digital pannal mounting type 96mmx96mm L&T cat no WDS301FCA00 including CT& selector switch for each outgoing
136(f) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch
137(g) LED TYPE indicator lamp1 set (set of three for R,Y,B)
138Supply, Installation, test and Commissioning, factoryfabricated LT panel board, type tested by CPRI /Authorised Govt. Agencies ,confirming toIEC 60349-1 & 2,up to 400 Amps incommer OR confirming toIEC 61349-1 & 2, above 400 Amps incommer,LT panel board made out of 2 mm thick GI Sheet multifold design, chemically treated surface with multi tank process powder coating,indoor modular type,dust free ,Vermin Proof , totally enclosed with Confirming to IP 43 for indoor panel & Confirming to IP 54 for outdoor panel ,single door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Galvanised iron Angle Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following :– Make of panel board-L&T / ABB / Schneider/Seimens or by their authorised channel partners duly authenticated by th company. (Main Panel-2 )
139INCOMING:-
140(a)MCCB 320 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&Tcat no- CM98403OOQOOG /Legrand ./schneider.- 1 no
141(b) Aluminium TPN Busbar 600 Amps - 1 Set
142OUTGOINGS:-
143(a) MCCB 250 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&Tcat no- CM92009OOP1OG /Legrand /schneider- 2 no (AMF PANAL & SPARE)
144(b) MCCB 125 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu L&T CAT NO-SL98653OOOO/ LEGRAND CAT NO-420086 /equivalent of ABB- 1 nos ( RADAR PANEL)
145( c ) Ammeter Class-1,digital pannal mounting type 96mmx96mm L&T cat no WDS301FCA00 including CT& selector switch for each outgoing
146(d) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch
147(e) LED TYPE indicator lamp1 set (set of three for R,Y,B)
148Supply, Installation, test and Commissioning, factoryfabricated LT panel board, type tested by CPRI /Authorised Govt. Agencies ,confirming toIEC 60349-1 & 2,up to 400 Amps incommer OR confirming toIEC 61349-1 & 2, above 400 Amps incommer,LT panel board made out of 2 mm thick GI Sheet multifold design, chemically treated surface with multi tank process powder coating,indoor modular type,dust free ,Vermin Proof , totally enclosed with Confirming to IP 43 for indoor panel & Confirming to IP 54 for outdoor panel ,single door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Galvanised iron Angle Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following :– Make of panel board-L&T / ABB / Schneider/Seimens or by their authorised channel partners duly authenticated by th company. (DG Panel )
149INCOMING:-
150(a)MCCB 250 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&Tcat no- CM92109OOP1OG /Legrand ./schneider.- 1 no
151(b) Aluminium TPN Busbar 400 Amps - 1 Set
152OUTGOINGS:-
153(a) MCCB 125 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu L&T CAT NO-SL98653OOOO/ LEGRAND CAT NO-420086 /equivalent of ABB- 3 nos ( Build DB , AC, & Sapre )
154(b) MCB TPN,4P, 63 Amps, 50 Hz, 415 Volts, 10 KA -01 Nos (Lift)
155(c) MCB TPN, 4P, 32 Amps, 50 Hz, 415 Volts, 10 KA -01 Nos (Water Supply)
156(d) MCB SPN, 2P, 32 Amps, 50 Hz, 415 Volts, 10 KA -02 Nos (St Lt , aviation light )
157( e ) Ammeter Class-1,digital pannal mounting type 96mmx96mm L&T cat no WDS301FCA00 including CT& selector switch for each outgoing
158(f) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch
159(g) LED TYPE indicator lamp1 set (set of three for R,Y,B)
160(h) Astronomical, digital time swithces -1 No
161(j) Power contactor MR 13 ,with 230 coil 1 No
162Supply and fixing Fin less design LED streetlight45 watt with pressurised die-cast housing LM6 alloy with IP66 protection and polycarbonate cover with IK07 impact resistance. It should have 10kV external surge protection. The product to have L70 life of 50000 hours and designed to operate from -10 to +45 degree celsius. The system efficacy to be 120Lm/w with system lumen of 8400 (+/- 1%) lumen output. Protection: High voltage cutoff & restart @ 320V +/- 15V and phase to phase 440Vprotection for 8 hrs is mandatory. The luminaire should have CRI 70.The driver should be potted to protect againt moisture.Make Philips / GE/ Osram/ Ligman/ havells /crompten
163Supply and fix M & L Hot dip galvanised Iron octagonal pole of height 7 mtrs minimum galavnising of 70 microns, top 70 mm , bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225x225x12 mm, foundation bolts of sizeM-24x750 mm long - 4 nos, single arm GI bracket of 900x1000 mm for mounting the light fitting at an angle of 120 degree,backelite sheet with one 6 A SP MCB and 16 mm stud type connectors -04 nos inside the pole at the door opening for cable connections,common template s minimum 01 for each 15 poles all fixed and bolted on and including suitable RCC pedestal of minimum size 0.4mx0.4mx1.4m including form work as per manufacturers design & Drawing recommendations and specifications all as directed Mast and pole shaft shall be be as per BSEN 10025,IS 5986, ASTM A572 , Galvanization as per IS-4759/2629 Make of pole- Bajaj / Jindal /Crompton/Shubham-
164Supply & fix in repair PVC insulated and sheathed copper multistranded cablethree core 1.5 sqmm, heavy dutythrough or on poleconnecting to cable looping box of street light fitting all as specified & directed
165Supply and fix cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revited withangle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
166Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited withangle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
167Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth strip 32x 6mm by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flatincluding earthingpit , charcoal common salt ,earth strip 32x 6mm up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 40 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pitcover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I)(VCB -4, Tranformer-4,LT panel-6, APFC panel -2 , Votage stabilizer-2 , UPS- 2)Note :- (1) Earth lead and GI pipe light grade 40 mm dia for protection against mechanical damage beyond 7.5 mtrfrom electrode to earth terminal point/main switch board. Etc shall be measured separately .
168Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
169S & F ON LOAD change over switch 4 pole 125amps with sheet metal enclosure,L&Tcat no-CO11250OSOO /schneider (For OEM DG Set)
170Supply and fix aviation obstruction light of 9 W LED twintype twin with doom and other fixing accessories
171EXTERNAL WATER SUPPLY
172Construction of brick masonry valve chamber of size 900 x 900 x 1200 mm (internal dia) suitable for 80 mm diavalve with necessary earth work excavation, plain cement concrete (1:4:8 )using 40 mm graded stone aggregate, 75 mm thick in cement mortar ( 1:6 ), 15 mm thick plastering (1:6) internally including flooring and externally upto 15 mm below ground level,plain cement concrete 1:4:8 type B1 using 20 mm graded stone aggregate in coping, MS sheet cover made out of 3mm thick MS sheet" flat iron frame and bracing with locking arrangement,applying two coats of synthetic enamel paint including dismantling removing the existing damage chamber completely, removal of debris & depositing all as specified & directed by Engr-in-charge [EXT WS 01]
173Supply, installation, testing and commissioninng of Openwell submersible pump, suitable for pumping water 40 LPM discharge at 40 m head, IP 55, cast iron body with gun metal impellers including fixing of safety valve, pressure guage and priming valve etc direct coupled suitable for operation on 3 phase, 415 V, AC, 50 Hz and mounted on channeliron base frame including nut, bolts & washers etc. PCC foundation, foundation nuts, bolts & washer as per manufacturer"s instructions including proper size cupper cable from starter to motor of suitable size all as specified & directed.(Pump-2 Nos: 1 Running & 1 Standby)
174Supply, Installation, test and Commissioning, factoryfabricated LT panel board, type tested by CPRI /Authorised Govt. Agencies ,confirming toIEC 60349-1 & 2,up to 400 Amps incommer OR confirming toIEC 61349-1 & 2, above 400 Amps incommer,LT panel board made out of 3.15 mm thick GI Sheet multifold design, chemically treated surface with multi tank process powder coating,indoor modular type,dust free ,Vermin Proof , totally enclosed with Confirming to IP 43 for indoor panel & Confirming to IP 54 for outdoor panel ,double door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Galvanised iron Angle Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following :– Make of panel board-L&T / ABB / Schneider/Seimens or by their authorised channel partners duly authenticated by th company. (Pump Panel )
175(a) Incoming MCB TPN 32 Amp and 10 KA breaking capacity, 415 volts-01 No
176(b) Outgoing MCB, 2 pole 25 Amp, 10ka-03 Nos
177(c)Voltmeter with selector switch -01 No
178(d)Ammeter with CT-03-01No
179(e) Indicator lamp -03 No
180(f) Single phasing preventer -01No
181(g) DOL starters including connected accessories such as indicators, motor protection devices & selector switches - 02 Nos. (For 1.5 to 2 HP)
182(h) Including suitable size ofgland for passing cable and lugs etc
183FIRE ALARM SYSTEM
184Read-M & L for Low smoke Zero helogen flame retardent fire alaram cable2 core, 1.5 mm² copper conductor confirming to BS7629-I , BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrierType LT53 outer sheathconfirming to BS 7655 , red in colourdrawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed.
185AIR CONDITIONING
186Supply, installation, testing & commissioning Split Air Conditioner 2 Ton, 5 star rating, inverter type technology, 230 V, 50 Hz, refrigerant -R32, single phase, indoor/ outdoor unit complete with cordless remote control unit and compressor- inverter rotary type, condenser-100% Copper type, noise level outdoor-60 dB and high cooling performance and desirable cooling mode for different types of climate. Make- Blue star/Voltas/LG
187Supply and fixing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variaiton between 170 volt to 280volt with output voltage stabilised at 230Volt with accuracy of ± 2.5% and of capacity of 5.0 KVA. (For 2 Ton Split AC)
188Supply, installation, testing & commissioning Split Air Conditioner 1.5 Ton, 5 star rating, inverter type technology, 230 V, 50 Hz, refrigerant -R32, single phase, indoor/ outdoor unit complete with cordless remote control unit and compressor- inverter rotary type, condenser-100% Copper type, noise level outdoor-60 dB and high cooling performance and desirable cooling mode for different types of climate. Make- Blue star/Voltas/LG
189Supply and fixing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variaiton between 170volt to 280volt with output voltage stabilised at 230Volt with accuracy of ± 2.5% and of capacity of 4.0 KVA.(For 1.5 Ton Split AC)
190Supply & fix MCCB DB vertical type, suitable for 125amp MCCB as ncomer mae of steel powder painted with neutral busbar 200A neutral link, IP 43, IK 09 protection grade, 415V TPN with 4 way double door all as specified & directed. make- L&T / Schenieder / ABB (AC main DB)
191INTERNAL WATER SUPPLY & WATER COOLER
192Supply and fix Chromium plated health faucet (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hinging the faucet
193Supply and fix Voltage stabilizer forautomatic operation, single phase naturallyair cooled indoor type & designed for inputvariation between 130 V to 290 V with output voltage stabilized at 230 V withaccuracy of ± 2.5% and of capacity 2 KVA
194ARBORICULTURE
195Supply, stacking and laying including spreading in layers to a uniform thickness of 10cm with approved sweet soil / garden soil obtained from outside MD land as approved by GE complete all as specified and directed.
196Supply and planting palm trees, approx height 1.2 mtr including necessary forming pit of size 90 cm x 90 cm x 110 cmand providingand filling manure mix sweet soil , watering daily and maintaining for a period of 11 months from the certified date of completion of Phase Icomplete all as specified and directed.
197M & L for development of lawn area and planting of carpet grass of any other approved by GEincluding watering for a period of 3 months and uniform cutting so as togive green surfacecomplete all as specified and directed.
198LIFT
199Material & labour of Earthing complete with copper plate electrode 60×60cm ×3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to copper strip 20x3 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, GIpipe medium grade of dia 40mm for protection of copper earth strip & 20mm dia medium grade GI watering pipe, PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pitcover including earth work all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and all as direction of Eingeer-in-Charge.[ Lift 02 + 04 LP +
200Comprehensive maintenance for Goods Lift
201Comprehensive maintenance and repairs of fully automatic electrically operatedgoods lift ,speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended suitable to serve up to G+6 (Totat height 31 m), two landing door at ground floor & upper floors with AC VariableVoltage & VariableFrequency Drive (VVVF drive)complete suitable to carry 1000 Kg load with all standard accessories, simplex automatic& manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03Nos, one each in car, Machine room & near Ground floor landing door) complete all asspecified. comprising of all devices and accessories through 36 months for all days including holidays etc after expiry of defects liability period as shown below and all as specified and directed to Engr-in-Charge Note : Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) as per attached Performa and maintain all the lifts in serviceable condition 24 hrs x 365 days with out any extra cost.
2021st year after expiry of defect liability period.
2032 nd year after expiry of defect liability period.
2043 rd year after expiry of defect liability period.
205Note :- (a) The Contractor shall Employ General mechanic/Electrician/FGM having minimum ITI qualification from Govt Recognised institute with adequate knowledge & minimum 2 years experience in maint/operation of lift installations.The operator must competent to carry out the minor maint all as directed. (TOTAL number of operators required per day are 02 nos.) (b) Contractor shall pay the wages to the employees through e-payment i.e Adhaar linked bank accounts (credit to their bank account). Engineer-in-charge shall ensure that e-payment made to employees and their wages shall not be less than minimum wages fixed by state Govt or Central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Eng.-in-charge and the same shall be kept in record duly verified. (c) It is the responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevaling scales as laid down by Ministry of labour for all operator/helper (as appliable) and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record.The quoted rates shall be deemed to be included of above provisions.In case contractor fails to produce the proof of EPF, the same shall be recovered from his dues as per the prevailing scale plus 15 percent.
206(d) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to the Engineer-in-Charge as well as officers detailed by central labour department. (e) Each shift duration shall be 8 hours & duty timing will be decided by Eng.-in-Charge. (f) The unit rate quoted shall deemed to be included for cost of labour for daily routine maintenance for trouble free functioning of installation. (g) In case of any abnormal noise/ complaint the plant should be put off and same should be brought to the notice of Eng.-in-charge. (h)The operator employed by the contractor shall be capable of carrying out minor repair/ maintenance & should have well experience in lift installation as applicable. . (j)The quoted rate is deemed to be inclusive of cotton waste, cleaning material etc. & Contractorwill ensure general area cleanliness and upkeep of the installation on daily basis. (k) The quoted rate is deemed to be inclusive of tools & testing instruments required for operation & maintenance of lift installation. (l)The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance.In case of failure to provide tools kit & safety kit (spanner sets, hand gloves), a penalty of Rs 3000/- will be recovered and levied
207(q)The Contractor shall not employ same tradesman continuously for more than 11 months during the Contract period. (r) The contractor shall provide 02 uniforms to each operatorand design of uniform shall be got approved.In case of failure, a penalty of Rs 2000/- per uniform will be levied and recovered from their dues. (s) In case of failure due to absence of operative staff, the contractor shall be liable to pay compensation at twice the cost of a day’s Manning & Operation derived from pro rata rate ofSch ‘A’ quoted rates. (t) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maint is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly. (u) The contractor shall provide board at proper location near each installations duly writing the name of operators and Mobile Numbers shiftiest.