Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #33804824

Special Repairs To Hanger Nos P 4 And 5 Building Nos P 4 And P 5 At Ins Kalinga Under Ge Kalinga

Issued by Statutory Bodies & Commissions/Committees · Kalinga, Andhra Pradesh
Tender Value
66 Lakhs
Estimated cost
Bid Submission
03 Oct 2022
0 days left
EMD
1.24 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kalinga → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Repairs To Hanger Nos P 4 And 5 Building Nos P 4 And P 5 At Ins Kalinga Under Ge Kalinga

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Sep-2022 TENDER DOCUMENTS Technical Bid 26-Sep-2022
2 16-Sep-2022 BOQ BOQ 26-Sep-2022
3 26-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-Oct-2022

BOQ

Name of Work: SPECIAL REPAIRS TO HANGER NO 4 & 5 (BUILDING NO P-4 & P-5) AT INS KALINGA, BHEEMUNIPATNAM (BOARD NO KLG/30/2021)
Sl. No. Item Description
1Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and directed
2M&L pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
3M&L pre-painted galvalume aluminum zinc coating GI based plainsteel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
4M&L 6 mm thick asbestos cementplain building boards, fixed to timber frame work with screws in ceiling and including dismantling complete all as specified and directed.
5M&L asbestos cement building board cover strips 50 mm x 5 mm with bevelled edges over joints and including all mitres, fixed with screws complete all as specified and directed
6M&L second class hardwood plain fillets, square, rectangular or triangular sectional area exc. 13 & n. exc 25 Sqcm in section, clean sawn, secured with nails and including dismantling complete all as specified and directed
7M&L roof treatment in order of precedence as given below complete all as specified and as directed:-(i) Taking out of existing water proofing treatment and including padding, cleaning the surface using wire brush, brooming down and washing down with water to remove dust etc, and brushing with neat cement slurry @ 3.00 kg of cement per Sqm.(ii) 15 mm thick screed bed in CM 1:4 on surface mixed with WPC as per manufacturers instructions.(iii) Cleaning of plastered surface and applying one coat of oil based bituminous primer conforming to IS -3384 (latest) @ 0.30 Ltr / Sqm.
8(iv) Supply and laying 3 mm (Minimum) thick APP based polymeric membrane of approved manufacturer with weight not less than 3.80 Kg per Sqm, reinforced with non-woven polyester fabric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 30 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(v) Applying one coat of bituminous aluminium primer @ 0.1. Lit / Sqm.Note :- (a) Primer, APP membrane & bituminous aluminium paint shall be of same manufacturer and executed through applicator authorised by the approved manufacturer only.(b) Membrane shall be laid with side overlap of 100 mm and end overlap of 150 mm as per manufacturers instruction.(c) WPC will be measured and paid seperately.
9Demolition of concrete in ground floors and pavings n.exc.15 cm thickness (below or above ground level) complete all as specified and directed.
10M&L PCCtype B1, 1:2:4 ( 20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed
11M&L PCC 1:2:4, type B1 (20 mm graded aggregate) in lintels upto 1.5 m clear span, cills, steps; plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed
12M&L 100 mm thik PCC 1:2:4, type B1 (20 mm graded aggregate) in floors finished spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed
13M&L 75 mm thick PCC 1:3:6, type C1 (20 mm graded aggregate) as in plinth protection,finished even and fair without using extra cement complete all as specified and directed
14M&L pressure guniting averaging 30 mm thick in CM 1:3 for concrete surfaces of columns, beams, slabs etc, after cutting / chipping the spaling concrete and trimming & claning the surfaces to receive the guniting byapplyingFOSROCNITOBOND AR (epoxy bonding agent) prior to guniting with a coverage of 6-8 Sqm / Litre and including necessary double scaffolding as required and removal of the same on completion of the work complete all as specified and directed.
15M&L making good broken / damaged RCC chajjas / beams etc, with PCC 1:2:4 type B1 or cement mortar 1:3 and including rendering 15 mm thick in CM 1:4 mixed with water proofing compound as per manufacturer\"s instruction to top, sides and soffits, including necessary scaffolding, formwork and reinforcement duly welded if required to a height up to 8 m complete all as specified and directed.Note:- Water proofing compound shall be measured and paid seperately
16M&Lhigh strength corrosion resistant TMT bars, grade Fe - 500 D,6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
17Dismantling of brick, PCC block or stone masonry built in cement mortar complete all as specified and directed
18M&L walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specifiedand directed.
19All as per Sl Item No. 17 above but except stone.NOTE: Serviceable quantity of stone obtained from Sl. Item No. 16 shall be reused under this item.
20M&L extra over stone walling for hammer dressing to face sones and dressing of the face bed & joits as speified for squarred rubble walling reqular coursed, Jodhpur type with maximum depression of face from straight edge held against the dressed surface n.exc 20 cm complete all as specified and directed.
21Taking down cement plaster of any description on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed
22M&L 15 mmthick renderingin CM 1:6 on fair faces of brick work or concrete surfaces finished even and smoothwithout using extra cement complete all as specified and directed
23M&L 15 mmthick rendering in CM 1:4, on stone masonry surfsce or surface other than fair face of brick work using WPC complete all as specified and directed.Note:- WPC shall be measured and paid separately.
24Supply only integral water proofing compound complete all as specified and directed.
25Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
26M&L rolled mild steel conforming to Fe 290 (Gde E-165), in rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel orflatsections) and including distance pieces, cleats etc. complete all as specified and directed.
27All as per Sl. Item No. 25 above but fabriation & erection fixing only.NOTE: Serviceable quantity obtained from Sl. Item No. 24 shall be reused under this item.
28S&F mild steel rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common raftersof Fe 410W (Grade E-250 quality A) complete all as specified and directed
29All as per Sl. Item No. 27 above but fabriation & erection fixing only.NOTE: Serviceable quantity obtained from Sl. Item No. 24 shall be reused under this item.
30M&L ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre / hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed
31M&L treatment of soil under plinth protection ATT at the rate of 5 litre of emultion per sqm of surface area complete all as specified and directed
32M&L providing and injecting chemical emulsion for post construction anti termite treatment along external wall below concrete apron using chemical emulsion @ 2.25 Ltrs / linear metre and including drilling and plugging holes etc, in apron complete all as specified and directed
33S&F 1.25 mm thick lath, steel rolling shutters,withgear operated type with bevel gear box and crank handle and including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated and including dismantling existing rolling shutters complete all as specified and directed
34M&L preparation of new plastered wall surfacesand including applying two coats of plastic emulsion paintover a coat of priming paintprimer complete all as specified and directed.
35M&L complete removing existing wall surface and including applying two coats of plastic emulsion paintover a coat of primer complete all as specified and directed.
36M&L preparation of new plastered wall surfacesand including applying two coats of cement based paint over a coat of primercomplete all as specified and directed.
37M&L complete removing existing wall surface andincluding applying twocoats of cement based paint over a coat of primercomplete all as specified and directed.
38M&L preparation of oldwooden surfaces and including applying onecoat of synthetic enamel paint complete all as specified and directed.
39M&L preparation of new asbestos cement boardsurfacesin celing and including applying two coats of synthetic enamel paintover a coat of primer as per manufacturers instructions complete all as specified and directed.
40M&L preparation of new steelsurfaces of anydescription over 10 cm in width or girth, not otherwise described and including applying two coats of aluminiumpaint over a coat of aluminium red oxide primer complete all as specified and directed.
41M&L preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and including applying one coat of synthetic enamel paint complete all as specified and directed.
42M&L grouting of column, beam etc,with cement slurry by mixing 50 Kg of cement with 18 to 22 litre of water with admixture of FOSROC CEBEX 100 (Plastized expanding grout admixture) about 225 gms per 50 Kg of cement) by drilling upto 12 mm dia. hole in RCC Surface upto required depth and grouting /pumping the grout with mechanically powered grout mixer upto 10 Kgfor each hole as per manufacturer\"s instructions and sealing the hole after grouting (GROUT= WATER+ CEMENT+ FOSROC CEBEX 100 in proportion) complete all as specified and as directed.
43M&L 100 mm thickPCC M-20 nominal mix flooring (1:1.5:3)type B-1 using20 mmgradedstoneaggregateas in flooringcomplete all as specified as directed.
44M&L 20 mm thick hardonite topping as specified (incorporated an approvednon metalic floor hardner), laid on concrete floor and pavings, and finished even and smooth surface complete all as specified and directed.Note : Non metalic floor hardner will be measured & paid separately
45Supply only non metalic floor hardner complete all as specified and directed.
46M&L forming Construction joint 30 mm deep x 10 mm wide filled with sealing compound of Grade A complete all as specified and directed.
47M&L insulation with 50 mm thickglass wool roll of density 16 Kg / Cumover false ceilingcomplete all as specified and directed.
48M&L 2 mm thick stainless steel 304 gradeplain sheet as in valley gutter and including fixing of stainless steel collar for drainage complete all as specified and directed.
49Taking down chowkhats or frames exc. 1.5 Sqm but n. exc. 4.0 Sqm each with shutters complete all as specified and directed.
50Taking down chowkhats or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
51Taking down shutters of any description n. exc. 1 Sqm each complete all as specified and directed.
52M&L second class hard wood plain solid straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
53S&F second class hard wood 30 mm thick glazed and skeleton shutters for window , open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(b), supplied and fitted to chowkats complete all as specified and directed.
54S&F second class hard wood 35 mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers: suppliedand fitted to chowkats complete all as specified and directed.
55S&F 100 mm butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
56All as per Sl. item No. 54 above but 125 mm long.
57S&F 100 mmaluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
58All as per Sl. item No. 56 above but 150 mm long.
59S&F 100 mm long aluminium handles, cast type anodised complete all as specified and directed.
60All as per Sl. item No. 58 above but 150 mm long.
61S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
62Hacking out old broken glass (any thickness, size, quality or description) from wooden / steelframes or stone, concrete or brick surrounds, glazed with putty or fixed with beads etc, complete all as specified and directed.
63S&F 4 mm thick plain sheet glass, ordinary quality and glazing with oil putty in square not exc. 0.5 sq. m in each pane complete all as specified and directed.
64S&F angle iron / flat iron as in hold fast, support of valley gutter and nosing etc, conforming to Fe-290 Gde-165 complete all as specified and directed.
65M&L PCC 1:3:6 type C-1 (using 20 mm graded aggregate)as in bedblock etc, complete all as specified and directed.
66M&L preparing new wooden surfaces of any description not otherwise described, over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed .
67S&F ball bearing for rolling shutters complete all as specified and directed.
68M&L excavation in trenches n.exc. 1.50 m wide and n.exc. 1.5 m deep for foundation or for shafts, wells, cesspits, manholes, pier holes not exceeding 10 Sqm on plan and getting out in soft / loosesoil complete all as specified and directed.
69M&LPCC 1:4:8, type D-2 (using 40 mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed.
70M&LPCC coping 1:2:4, type B-0 (using 12.5 mm graded aggregate) as in coping and including necessary form work, weathering, slightly roundedor chamferedangles and throating complete all as specified and directed.
71M&L PCC 1:2:4, type B-1 (using 20 mm graded aggregate) as in surface channels and drains etc, complete all as specified and directed.
72M&L framed work such as grills, gratings etc,with ends of bars shouldered and / or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
73M&L removing surplus excavatedmaterial notexc. 50 m and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed.
74Taking down carefully existing copper / aluminium conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc, and removing materials from site and making good the disturbed surfaces of walls roof and floor etc, as per existing specification complete all as specified and directed.
75Taking down carefully existing light fittingsand including keep in safe custody and refixing the same after completion of repairs complete all as specified and directed.
76M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including suitable dia stove enamelled ERW MS conduit, ISImarked and conduit accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed,FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories for one light / fan / exhaust fan point controlled by one 5 / 6 Amps switch cand including taking down complete all as specified and directed.
77M&L point wiring with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing / new concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes, readily available (having wall thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 2 mm thick bakelite sheet cover for mounting switches, sockets etc,for one light / fan point controlled by one 5 / 6 Amps switch and including cutting chasing (as required) and making good surfaces to match with adjoining surface & taking down complete all as specified and directed.
78All as per Item no. 76 above or one 5 / 6 Amps socket outlet point on independent board.
79M&L point wiring with 2.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing / new concealed conduit along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes, readily available (having wall thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 2 mm thick bakelite sheet cover for mounting switches, sockets etc,for one 5 / 6 Amps socket outlet point on independent board and including cutting chasing (as required) and making good surfaces to match with adjoining surface & taking down complete all as specified and directed.
80S&F switch socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed.
81S&Fswitch pianoflush typeone way, 5 Amp, 240 voltcomplete all as specified and directed.
82S&F switch socket combination2 in 1,6 Pin, 5 & 15 Amp, flush type universal complete all as specified and directed.
83S&F ceiling rose, surface bakelite 65 x 50 mm three terminalcomplete all as specified and directed.
84S&F flame proof rotary switch with separate cable terminal box and including rubber gasket as per IS 2149, SP 16 amps, singlepole, 250 volts ISI marked for ON / OFF light made out aluminium alloy LM-6 marked in high tensile steel withanticorrosive epoxy paint grey shade CMRI certified with cable entries and including taking down complete all as specified and directed.
85S&F 40 mm bore galvanised steel water tubing, light grade with necessary fittings fixed laid in trenches / wall / floor for cable protection complete all as specified and directed.Note: Earthwork excavation earth workshall be measured and paid separately
86S&F flame proof switch socket & plug combined inLM6 cable termination box in LM6 16 A 250 V 2P+ Earthand including taking down complete all as specified and directed.
87S&F flame proof threaded junction boxes in LM6- 2 / 3 / 4 way suitable for 20 / 25mm diaERW Steel coundit, certified CIMFR for gas group I, IIA &IIB for Zone I & II and including taking down complete all as specified and directed.
88S&F LED light fitting 2 x 16 watt flame proof, CMRI certified recommended for gas / vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc, complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size and includingtaking down complete all as specified and directed.
89S&F flame proof wellglass LED lightfitting suitaible for 60watt LED as per IS 13947body made out of aluminium alloy LM-6 epoxy painted with guard, reflector, flameproof clear glass along with all accessories prewired CMRI certified and hardware in high tensile with corrosive epoxy grey shade paint fixed to wall / ceilling and including flameproof flexible wire from fitting to terminal pointand including taking down complete all as specified and directed.
90S&F indoor luminaredecorative batten for wall / ceiling mounting box type, extruded aluminiumhousing, PC diffuser, energy efficient saving LED batten light 20 W, 230 V, 50 HZ, slim integrated design easyinstalland including twin twisted copper conductor flexible wire from ceiling rose to connectorand including taking down complete all as specified and directed. Make: CG Cat Part no.CCS-100-20-65-HL2-DP-NWH or equivalent inPhilips / Havells / Surya Roshni Ltd / Wipro / GE / Bajaj / M/s Gold Medal Electricals Pvt. Ltd as approved by GE.
91S&F security LED light luminaire fitting 1 x 25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable and 25 mm GI bracket medium grade 1m long fixed on wall, bent to shape with necessary bolt, nut, washer, clamp etcand including taking down complete all as specified and directed.
92S&F flame proof weather proof encloser for MCCB DB TPN incoming 63 amp MCCB andincluding gas cutring endless Neoprene rubber gas kitIP 66 as per IS 2147/1962, ISI marked made out of cast aluminium alloy LM-6,epoxy painted CMRI certified 63 amps AC supply 230 volts one incomming and 6 nos out going and including taking down complete all as specified and directed. Make: Sudhir cat no MCDB / 186 or or equivalent in Baliga / Shyam as approved by GE.
93S&F Flame proof, weather proof encloser for MCB DBincoming 40amp DP including gas cutring endless Neoprene rubber gas kitIP 66 as per IS 2147/1962 ISI marked made out of cast aluminium alloy LM-6,epoxy painted CMRI certified 63 amps AC supply 230 volts one incomming and 4 nos out going including taking down old unserviceable DB complete all as specified and directed.Make: Sudhir cat no. CDB / 186 or equivalent in Baliga / Shyam as approved by GE.
94S&F sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4 way with dim rail earth and neutral bar complete all as specified and as directed.
95S&F MCB Single Pole (SP) C curve 10kA breaking capacity of6 to 32 amps, 240 Volts in proper positionall as specified and directed.
96S&F MCB Double Pole of capacity up to 40 amps, 240 Volts c-series with 10 KA breaking capacity complete all as specified and directed
97M&L sub main wiringwith two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and including sutaible dia stove enameled ERW MS conduit medium grade 25 mm dia ISI marked complete with fittings and fixings accessories fixed in surface of wall / ceilling / floors etc, and taking down complete all as specified and directed.Note :- copper conductor 2 run of 2.5 sq mm and 1 run of 2.5 sq mm of copper earth wire along with MS conduit shall be measured as one lenth complete all as specified and directed
98M&L sub main wiringwith two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including steelconduit medium grade 25 mm dia ISI marked with fittings and fixings accessories complete and including taking down complete all as specified and directed.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
99All as per item No. 97 above but with 2 runs of6 sqmm main wire along with 1 run of 6 sqmm earth wire.
100S&F air termination single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed
101M&L aluminiumstrip 25 x3.15 mm and including insulating block, saddle and fixing screws etc,fixing arrangementfor all earthing connections complete all as specified and directed.
102S&F GIstrip 25 x 6 mm with saddles and fixed with screws etc, for wall conductorsconnected with equipment andabove ground(proper insulation should be provided between strip & walls) and including taking down complete all as specified and directed.
103M&L test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed and including 3 nos. 8 mm dia 25 mm long hex, head screws and including taking down complete all as specified and directed.
104M&L earthing complete with 3 m long CI pipe 80 mm dia with flanged ends, centifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 2.5 mlength buried directly and preferably vertically in ground with top flanged ended 2.5 mbelow ground level welded / connected with GI strip 32 × 6 mm size on the top edge of the flange to bottom edge of the flanged for earthing andincluding filling the pit with charcol common salt surrounding the earth pipe, drilling 400 mm dia bore in any strata of soil to lower the CI pipe, necessary excavation and earth work, PCC(1:3:6) type C-1 with 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab etc,complete all as specified and directed . .

AI Tender Summary

OUR REF NO 33804824
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 66 Lakhs
LAST DATE 03-10-2022
Authority
Authority Name Military Engineer Services
Work Description Special Repairs To Hanger Nos P 4 And 5 Building Nos P 4 And P 5 At Ins Kalinga Under Ge Kalinga
Basic Detail
Tender No 82583
Bidding Type Tender
Location
City Kalinga
State Andhra Pradesh
Key Dates
Publish Date 26 Sep 2022
Submission Date 03 Oct 2022
Open Date 05 Oct 2022
Finance
Tender Value 66 Lakhs
Tender Fee 1000
EMD 1.24 Lakhs
Exemption Not Available
Document List
23f8a6fe-2157-4d7b-8dbf-b39ec4280490.html
82583TENDER.pdf
BOQ_615069.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 26, 2022
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 03, 2022
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 03, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 05, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

23f8a6fe-2157-4d7b-8dbf-b39ec4280490.html

pdf

82583TENDER.pdf

xls

BOQ_615069.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders