Rewiring With Copper Conductor In 11 Houses 151 152 201 203 204 207 208 209 237 239 241 At Pec
Tender Value
14.52 Lakhs
Estimated cost
Bid Submission
12 Sep 2022
0 days left
EMD
29043
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Rewiring With Copper Conductor In 11 Houses 151 152 201 203 204 207 208 209 237 239 241 At Pec
BOQ
| Sl. No. | Item Description |
| 1 | WIRING |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecorecableinsurface /recessedmediumclassPVC conduit, with modular switch, modular plate, suitable GI box and earthingthepointwith 1.5sq.mm FRLSPVC insulated copper conductor single core cable etc. as required. |
| 3 | Group B |
| 4 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulatedcopperconductorsinglecorecableinsurface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 6 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 7 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 8 | Group B |
| 9 | Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 10 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required. |
| 11 | 1 x 1.5 sq. mm |
| 12 | 3 x 1.5 sq. mm |
| 13 | 3 x 2.5 sq. mm |
| 14 | 3 x 4 sq. mm |
| 15 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 16 | 2 Pair |
| 17 | Supplying and fixing of following sizes of medium class PVC conduitalongwithaccessoriesinsurface/recessincluding cutting the wall and making good the same in case of recessed conduit as required. |
| 18 | 20 mm |
| 19 | 25 mm |
| 20 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 21 | 5/6 A switch |
| 22 | 2 way 5/6 Amp switch |
| 23 | 15/16 A switch |
| 24 | 3 pin 5/6 A socket outlet |
| 25 | 6 pin 15/16 A socket outlet |
| 26 | Telephone socket outlet |
| 27 | Bell push |
| 28 | TV antenna socket outlet |
| 29 | Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 30 | Supplying and fixing modular blanking plate on the existing modularplate&switchboxexcludingmodularplateas required. |
| 31 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 32 | 1 or 2 Module (75mmX75mm) |
| 33 | 3 Module (100mmX75mm) |
| 34 | 6 Module (200mmX75mm) |
| 35 | 8 Module (125mmX125mm) |
| 36 | 4 Module (125mm x75mm) |
| 37 | 12 Module (200mmX150mm) |
| 38 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 39 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 40 | Supplying and fixing 3pin, 5A ceiling rose on the existing junctionbox/woodenblockincludingconnectionsetc.as required. |
| 41 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 42 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 43 | SupplyingandfixingPVC batten/angle holderincluding connections etc. as required. |
| 44 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 45 | 4 way (4 + 12), Double door |
| 46 | 6 way (4 + 18), Double door |
| 47 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. |
| 48 | Single pole |
| 49 | Triple pole with neutral |
| 50 | EarthingwithG.I.earthpipe 4.5metrelong,40mmdia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 51 | Providing and laying earth connection fromearth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 52 | Supply, installation , testing and commissioning of 1200mm sweep BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, clas of insulation :B, 3 nos. blades, 30cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, air delivery minimum 215 CMM, 350 RPM (tolerence as per IS: 374-2019), THD less than 10% remote or electronic regulator unit fo speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.) inulation resistance more than 2 mega ohm, suitable for 23 V, 50Hz, single phase AC supply, earthing etc complete as required |
| 53 | Suppply and erection of AC ceiling fans with copper winding but without regulator complete with MS blades, plastic canopies 2 nos double ball bearing, MS hanging rods (As per site requirement), condenser, reels, clamps erc. The body of fan and blades should be white in colour. The job includes the cost of making necessary connections from the adjacent light point with 1.5mm2 single core copper consuctor cable and 3mm thick white BL sheet cover for fan box of suitable size. The sample of fans shall be got approved from the SDE in charge of work before installation at site. The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer in charge.Makes Havells-Velocity/Orient-New Breeze/Crompton-High Speed/ Usha-Strikers/Bajaj- Speedster only |
| 54 | Size 56\" (1400mm) |
| 55 | Supply and errection of 1x20 watt 4\" long LED box type fittings with decortative end caps of make Crompton CAT no. DMLNILT8-16+LT8-20-865-2 or equivalent models of make Philips/Surya make only .The LED tube rod 20 watt polycarbonate with inbuilt driver, extruded aluminium heat sink, 30000 burning hours at 70% lumens maintenance of makes Philips/Havells/Wipro/Crompton/Bajaj. The job includes carriage, erection, making connections with 3x1.5 sq.mm copper wire from adjacent light point, testing and commissioning of the fittings etc. as requried to complete the same to the entire satisfaction of engineer in charge. |
| 56 | Supply and erection of exhaust fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing wirh minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the exisiting opening including cost of carriage charges, making connection, testing,commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer in charge. |
| 57 | Size 12\"\" sweep 900 RPM with louver complete in all respect with necessary connections. Makes:- Havells- turbo force SP/crompton- EXHD 300-6-1/Bajaj-Supreme DLX. |
| 58 | Supply installtion testing and commission of 10\" exhaust fan 1350 rpm in plastic body, make Orient, Usha, GEC, Crompton (for toilet/WC) |
| 59 | Providing and fixing of MS 10mm dia S type fan hook which includes fixing in the steel bar of RCC slab and repairing the same in good condition. |
| 60 | Supply, installation, testing and commissioning of bulk head LED 10 watt IP65/66 fitting to be fixed on wall. Make and model of fitting as underPhilips:- WT202W LED65 CW PSU S2 PC Bajaj: IVORA LED Bulk head 10W CDLCrompton: LBHP-10-CDL |
| 61 | Supply erection ofGI flexible pipe 1\" dia including couplers |
| 62 | Making hole for installation of exhausht fan/fresh air fan of size upto 450mm sweep by demolishing brick work manually/by mechanically means including disposal of mabla within 50 mtr. lead and making good the wall by plastering etc as required. |
| 63 | Supp1y and erection of 63 amp MCB TPN 10 KA, C series in original sheet steel enclosure to be fixed on existing surface make L&T, Havells, Schnieder, Legrand,ABB |
AI Tender Summary
Tender Timeline
Sep 05, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedSep 12, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 12, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender