| 1 | MCB Single Pole 240/415V, 50 Hz. Channel Mounted |
| 2 | 2A |
| 3 | 4A |
| 4 | 6A |
| 5 | 10A |
| 6 | 16A |
| 7 | 20A |
| 8 | 25A |
| 9 | 32A |
| 10 | 63A |
| 11 | MCB Double Pole 240/415V, 50 Hz, AC Supply,Channel Mounted |
| 12 | 2A |
| 13 | 4A |
| 14 | 6A |
| 15 | 10A |
| 16 | 16A |
| 17 | 20A |
| 18 | 25A |
| 19 | 32A |
| 20 | 40A |
| 21 | 63A |
| 22 | MCB TriplePole 240/415V, 50 Hz, AC Supply, Channel Mounted |
| 23 | 32A |
| 24 | 63A |
| 25 | 6A |
| 26 | 10A |
| 27 | MCB Four Pole 240/415V, 50 Hz, AC Supply, Channel Mounted |
| 28 | 2A |
| 29 | 16A |
| 30 | 20A |
| 31 | 32A |
| 32 | 63A |
| 33 | 6A |
| 34 | RCCB Four pole 240/415V, 50Hz, AC Supply, DIN Rail mounted |
| 35 | 63A, 100mA |
| 36 | 40A, 100mA |
| 37 | MCB Double pole DC, Breaking capacity: Ue=220 VDC, lcu=20kA, Ue=440 VDC, lcu=10kA, Ue=500 VDC, lcu=6kA, Uimp=6kV 10kA, Ics=75%lcu, DIN rail mounted |
| 38 | 1A |
| 39 | HRC Fuse Links conforming to IS:13703-II, 80 KA, 415 V, 50 Hz ,NS Type with staggered tag in following ratings: |
| 40 | 2A, NS-2 |
| 41 | 4A, NS-4 |
| 42 | 6A, NS-6 |
| 43 | 10A, NS-10 |
| 44 | 16A, NS-16 |
| 45 | 20A, NS-20 |
| 46 | 32A, NS-32 |
| 47 | DIN Fuse 415 V, 50 Hz, Breaking capacity: 100kA, Type: HN, Confirms to IEC 60269-2, IS 13703 part-2 |
| 48 | 125A Size-000 |
| 49 | 200A Size-0 |
| 50 | 125A Size-00 |
| 51 | DIN Fuse 500 V, 50 Hz, Breaking capacity: 120kA, Type: NH, Confirms to IEC 60269-2, IS 13703 part-2 |
| 52 | 63A Size-000 |
| 53 | 100A Size-000 |
| 54 | Bolted Fuse 240 V, 50 Hz, Breaking capacity: 200kA, Type: 160LET (Semiconductor Fuse), Confirms to IEC 60269-2, IS 13703 part-2 |
| 55 | 160A |
| 56 | Bolted Fuse 415 V, 50 Hz, Breaking capacity: 80kA, confirms to IEC 60269-2, IS 13703 part-2 |
| 57 | 200A Type: DD200 |
| 58 | Bolted Fuse 690 V, 50 Hz, Breaking capacity: 200kA, (Semiconductor Fuse), Confirms to IEC 60269-2, IS 13703 part-2 |
| 59 | 350A Type: 350FM |
| 60 | 63A Type: ET |
| 61 | 80A Type: ET |
| 62 | DIN Type HT HRC Fuse: 100 A, 6.6 KV, Model: FEHVP, Short circuit withstand current rating: 40kA, Confirms to IEC 60282-1 |
| 63 | DIN Type PT Fuse: 3.15 A, 12 KV Model: ABCNA Breaking capacity 45 KA |
| 64 | DIN Type PT Fuse: 2 A, 6.6 KV Model: FEVT |
| 65 | 690/700 V, 50 Hz, 200 kA, Type: Square body DIN 43 653, Stud Mount 1100 A Size:3 |
| 66 | Ceramic Fuse R055: Rating: 250V, 2A |
| 67 | HRC Fuse Link 80 KA HF Type |
| 68 | 2A |
| 69 | 4A |
| 70 | 6A |
| 71 | 10A |
| 72 | 16A |
| 73 | 20A |
| 74 | 25A |
| 75 | 63A |
| 76 | 32A |
| 77 | LT HRC Fuse operating voltage 500V 50 Hz Breaking capacity 80KA Performance requirement of IS 9224 Part-II 1979 and IS:13703/1993 & Mark ISI NH -Type |
| 78 | 6A Size 00 |
| 79 | 10A Size 00 |
| 80 | 16A Size 00 |
| 81 | 25A Size 00 |
| 82 | 32A SIZE 00 |
| 83 | 63A Size 00 |
| 84 | 100A Size 00 |
| 85 | 160A Size 01 Grade-Ii |
| 86 | 200A Size 00 |
| 87 | 250A Size 01 Grade-II |
| 88 | 200A Size 01 Grade-II |
| 89 | 315A Size 02 Grade-II |
| 90 | 400A Size 02 Grade-II |
| 91 | Type of rating TIA Type |
| 92 | 32A |
| 93 | 63A |
| 94 | 16A |
| 95 | LT HRC Fuse operating voltage 500VAC ,50 Hz Breaking capacity 80KA Performance requirement of IS 9224 Part-II 1979 and IS:13703/1993 & Mark ISI |
| 96 | NH Type 250 Amp Size 02 |
| 97 | NH Type 80 Amp Size 00 |
| 98 | NH Type 6 Amp Size 00 |
| 99 | TIA Type HRC Fuse base & carrier of rating 32 Amp |
| 100 | PVC Insulating Tape Rolls (Type F-PVC/90/0) with nominal thickness 0.125 mm Exp. Date must be 12 month from the date of supply in Size :- (0.125 mm x 1.8 cm x 8 m) |
| 101 | Red Colour |
| 102 | Yellow Colour |
| 103 | Blue Colour |
| 104 | Green Colour |
| 105 | Black Colour |
| 106 | Insulated Copper Lugs (Pin Type) in following sizes: |
| 107 | 0.5mm Sq. |
| 108 | 1.5mm Sq. |
| 109 | 2.5mm Sq. |
| 110 | 4mm Sq. |
| 111 | 6mm Sq. |
| 112 | 10mm Sq. |
| 113 | 16mm Sq. |
| 114 | 25mm Sq. |
| 115 | 35mm Sq. |
| 116 | Insulated Copper Lugs (Fork Type) in following sizes: |
| 117 | 0.5mm Sq. |
| 118 | 1.5mm Sq. |
| 119 | 2.5mm Sq. |
| 120 | 4mm Sq. |
| 121 | 6mm Sq. |
| 122 | 10mm Sq. |
| 123 | 16mm Sq. |
| 124 | Insulated Copper Lugs (Ring Type) in following sizes: |
| 125 | 0.5mm Sq. |
| 126 | 1.5mm Sq. |
| 127 | 2.5mm Sq. |
| 128 | 4mm Sq. |
| 129 | 6mm Sq. |
| 130 | 10mm Sq. |
| 131 | 16mm Sq. |
| 132 | 25mm Sq. |
| 133 | 35mm Sq. |
| 134 | 50mm Sq. |
| 135 | 70mm Sq. |
| 136 | Ring & Tongue Type heavy dutyCopper Lugs, Tin plated confirming to DIN 46235 / equit.; in following sizes: |
| 137 | 35mm Sq. |
| 138 | 50mm Sq. |
| 139 | 70mm Sq. |
| 140 | Aluminium Lugs(Pin Type) in following sizes: |
| 141 | 6mm Sq. |
| 142 | 10mm Sq. |
| 143 | 16mm Sq. |
| 144 | 35mm Sq. |
| 145 | Aluminium Lugs(Hole Type) in following sizes: |
| 146 | 6mm Sq. |
| 147 | 10mm Sq. |
| 148 | 16mm Sq. |
| 149 | 25mm Sq. |
| 150 | 35mm Sq. |
| 151 | 70mm Sq. |
| 152 | 120mm Sq. |
| 153 | 150mm Sq. |
| 154 | 185mm Sq. |
| 155 | 240mm Sq. |
| 156 | 300mm Sq. |
| 157 | 400mm Sq. |
| 158 | 90mm Sq. |
| 159 | Copper Lugs Hole type (Heavy duty) |
| 160 | 6mm Sq. |
| 161 | 10mm Sq. |
| 162 | 16mm Sq. |
| 163 | 25mm Sq. |
| 164 | 35mm Sq. |
| 165 | 70mm Sq. |
| 166 | 120mm Sq. |
| 167 | 150mm Sq. |
| 168 | 185mm Sq. |
| 169 | Aluminium Lug In Line Connector |
| 170 | 2.5mm Sq. |
| 171 | 6mm Sq. |
| 172 | 16mm Sq. |
| 173 | 25mm Sq. |
| 174 | 35mm Sq. |
| 175 | 70mm Sq. |
| 176 | 120mm Sq. |
| 177 | 185mm Sq. |
| 178 | 240mm Sq. |
| 179 | 300mm Sq. |
| 180 | Copper In Line Connector (Long size) |
| 181 | 6mm Sq. |
| 182 | 10mm Sq. |
| 183 | 16mm Sq. |
| 184 | 25mm Sq. |
| 185 | 35mm Sq. |
| 186 | Ring type Aluminium Lug (heavy duty) confirming to DIN46329/IEC1238 part-I/IS 8309 |
| 187 | 10mm Sq. |
| 188 | 16mm Sq. |
| 189 | 35mm Sq. |
| 190 | 50mm Sq. |
| 191 | 70mm Sq. |
| 192 | 120mm Sq. |
| 193 | 150mm Sq. |
| 194 | 240mm Sq. |
| 195 | 300mm Sq. |
| 196 | 630 Sq mm chamfered mouth for 11 KV XLPE cable |
| 197 | 185 Sq mm chamfered mouth for 11 KV XLPE cable |
| 198 | 150 Sq mm chamfered mouth for 11 KV XLPE cable |
| 199 | Straight thru \"Cu\" Lugs |
| 200 | 0.5mm Sq. |
| 201 | 1.5mm Sq. |
| 202 | 2.5mm Sq. |
| 203 | 10mm Sq. |
| 204 | 16mm Sq. |
| 205 | 25mm Sq. |
| 206 | Insulated Copper Lugs (U type) in following sizes |
| 207 | 0.5mm Sq. |
| 208 | 1.5mm Sq. |
| 209 | CABLE GLAND: Double compression heavy duty brass cable gland; Ni plated, confirming to BS 6121/IEC62444/IEC 60529, IP 66/67 for armoured Al XLPE cable |
| 210 | 3C X 240Sq. mm |
| 211 | 3C X 185Sq. mm |
| 212 | 3C X 150Sq. mm |
| 213 | 3C X 120Sq. mm |
| 214 | 3C X 35Sq. mm |
| 215 | 3C X 25Sq. mm |
| 216 | 3C X 6Sq. mm |
| 217 | 5C X 2.5Sq. mm |
| 218 | Cable Gland SS 1/2\" |
| 219 | Cable Gland SS 1\" |
| 220 | Insulating Hand Gloves (pair) workingVoltage 1100VTest Voltage =11000 V ACSize- 355mm |
| 221 | Cotton Hand Gloves (pair) for opening and closing Steam Valves and other heat areas; Size- Medium; Thickness- 5-10mm; Plain; Leather (Buff/Split/Chrome) |
| 222 | INDICATING LAMPS: Cluster LED Type-3PLBRL 220V DC (Red, Green, Amber, Milky 100 Nos.each)Dia 22.5 mm with adaptor plate (2 Nos.) for 30.5 mm Dia Hole |
| 223 | INDICATING LAMPS: LED Type indicating Lamp Assembly ?-22.5mm, 110V AC AC/DC (Red, Green, Amber, Milky). |
| 224 | INDICATING LAMPS: RCB7-IVL-73-110, LED PILOT LIGHT, 110 AC, GREEN COLOR |
| 225 | INDICATING LAMPS: RCB7-IVL-73-110, LED PILOT LIGHT, 110 AC, RED COLOR |
| 226 | GEN X Cluster LED Type (LVGP),220 V DC |
| 227 | Blue |
| 228 | White |
| 229 | Clear |
| 230 | Amber |
| 231 | Green |
| 232 | Red |
| 233 | GEN X Cluster LED Type (LVGP),240 V AC |
| 234 | Blue |
| 235 | GEN X Cluster LED Type (LVGP),64 V AC/ DC |
| 236 | Red |
| 237 | Yellow |
| 238 | Blue |
| 239 | Cluster LED Type, 110 V AC |
| 240 | Green |
| 241 | Red |
| 242 | Amber |
| 243 | Indicating Lamp Assembly Type-RB2-BVL as per IS-13947-5-1 IEC-947-5-1(Red/Green/Amber/Blue), |
| 244 | Red(RB2-BVL74) |
| 245 | Green(RB2-BVL73) |
| 246 | Amber (RB2-BVL75) |
| 247 | Blue(RB2-BVL76) |
| 248 | Cluster LED Type-3PLBRL 220V AC (Red, Green, Amber, Milky ) Dia 22.5 mm with adaptor plate (2 Nos.) for 30.5 mm Dia Hole |
| 249 | Illuminated Push Button BCH 30.5MM with 1 NO +1 NC, 240 V, Red/Green colour lense |
| 250 | TERMINAL BLOCKS: Stud Type terminal block (Melamine Housing) Khaki color |
| 251 | 4 Sq mm (current rating 36A) |
| 252 | 10 Sq mm (current rating 45A) |
| 253 | 16 Sq mm (current rating 87A) |
| 254 | 35 Sq mm (current rating 145A) |
| 255 | 25 mmsq screw type TB |
| 256 | Bus bar Type terminal block (Melamine Housing) Khaki color |
| 257 | 16-50 Sq mm (current rating 145A) |
| 258 | 50-95 Sq mm (current rating 250A) |
| 259 | 70-120 Sq mm (current rating 300A) |
| 260 | 120-185 Sq mm (current rating 450A) |
| 261 | Clip on Type terminal block (Melamine Housing) Khaki color |
| 262 | 35 mmsq |
| 263 | 25 mmsq |
| 264 | 16 mmsq |
| 265 | 10 mmsq |
| 266 | 6 mmsq |
| 267 | 4 mmsq |
| 268 | 2.5 mmsq |
| 269 | Rubberized Cork Sheets confirming to IS 4253 PT-II of 1980 RC-70C Grade Size of sheet : 915x610 mm of following Thickness |
| 270 | 2.00 mm |
| 271 | 4.00 mm |
| 272 | 6.00 mm |
| 273 | 8.00 mm |
| 274 | 10.00 mm |
| 275 | 12.00 mm |
| 276 | Switch fuse unit with HRC 100A TPN |
| 277 | Switch fuse unit with HRC 63A TPN |
| 278 | Switch fuse unit in steel box 63 Amp 4 Pole(3P+1N) |
| 279 | Switch fuse unit with steel box 100 Amp 4 Pole(3P+1N) |
| 280 | Rewireable Porcelain Main Switch Fuse Unit TPN 200A, withsteel enclosures and side operating handle |
| 281 | Change Over Switvh 200A, 3PH, 4Pole |
| 282 | Control transformer 415v/110v AC 150 VA |
| 283 | STOP (RED) PB PUSH BUTTON WITH 1NC CONTACT 22.5 MM |
| 284 | START (GREEN) PB PUSH BUTTON WITH 1NO CONTACT 22.5 MM |
| 285 | 6 AMP SP AUTO/OFF/MANUAL SELECTOR SWITCH |
| 286 | Water proof,Puncture Resistant,Good Mechanical strength,Non Corrosive Electrical grade Adhesive,Fire Retardent,: Size 1.9 cm (W) x 0.3 mm (T) x 20 Mtr.(L) Specification:-Thickness-0.3mm+/-10%,Adhesion to steel-100 Gms/Cm,Tensile Strength-8 Kg/Cm,BDV-2KV with 50% Overlap |
| 287 | Polimeride Film Tape,0.05mm thick Polymide film coated uniformly on one side with with silicon adhesive :Size 2.5cm (W) x .05mm (T) x 25 Mtr. (L), Specification:-Total thickness (mm)0.08mm Minimum, Adhesive to Steel (gm/2.54cm)-800 Minimum,Tensile Strength (Kg/2.54cm)-30.0 Minimum, Elogation (%)-70.0 Minimum. BDV (Kv) (50% overlap)-11.0 Minimum, Flammability-Self Extingiuishing, |
| 288 | HT insulation Sleeves equivalent to permagrip |
| 289 | Size 25 mm dia |
| 290 | Size 16 mm dia |
| 291 | Size 8 mm dia |
| 292 | ControlTransformer resin cast 415/240V AC, 15KVA ,1-PH, freq:50Hz, Type:AN, HSV/IL: 0.66/3KV, INS CLASS: B, STD. IS: 12021/1987 |
| 293 | Control Transformer :-voltage 415/240V, capacity:250VA, 1-phase,freq-50Hz,line volts: I.L.0.66/3.0KV INS class:B,STD. IS:15/07/115803/9 |
| 294 | Lighting Transformer:-voltage 415/240V, capacity:1000VA, 1-phase,freq-50Hz, INS class:B |
| 295 | Lighting Transformer:-voltage 415/240V, capacity:2500VA, 1-phase,freq-50Hz, INS class:B |
| 296 | welding Transformer:-voltage 415/415V, capacity:50KVA, 1-phase,freq-50Hz,Dyn 11 INS class:B |
| 297 | Switch Fuse Unit with 32 A,TPN HRC fuse |
| 298 | Switch Fuse Unit with 125 A TPN HRC fuse |
| 299 | 11/6.6 kV PT Fuse, 3.15 Amp, 12 ABCNA3-15,12kVAC, Interrupt rating 45 kA,carridge ,Length : 195.3mm,Diameter : 25.4mm |