Repairs Maintenance To Em Installation And Repair Repalcement Of Electric Fittings And Fixtures Wiring At Mes 352 I Asc Supply Stn Hq Aro And Other Connected Wks At Gms Under Ge I Gos
Tender Value
25 Lakhs
Estimated cost
Bid Submission
23 Sep 2022
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
gopalpur → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repairs Maintenance To Em Installation And Repair Repalcement Of Electric Fittings And Fixtures Wiring At Mes 352 I Asc Supply Stn Hq Aro And Other Connected Wks At Gms Under Ge I Gos
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 2 | Dismantling posts or struts (wood, steel or RCC) embedded in natural ground etc any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 3 | Excavation in soft / loose soilfor post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed. |
| 4 | M&L for PCC 1:3:6 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | Mild SteelFe-410-W Gde E-250 or Fe-290 Gde E-165 round bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 6 | S&Frolled mild steel section in framed work as in doors or gates of angle or other section withgusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging of grade Fe- 290 (Gde E-165) complete all as specified and directed. |
| 7 | M & L for angle iron posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. incl embedding in concreate including all necessary drilling, bolting or riveting, etc. and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed. |
| 8 | Supply only PVC coated chain link fencing 100 x 100 mm mesh size made out of GI wire from 2.5 to 2.85 mm dia having minimum 1mm thick PVC coating over it including inner woven wire.Weight of wire mess not exc 4kg/sqm complete all as specified and directed. |
| 9 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standars, rails, straining bolts etc including provision of building wire. |
| 10 | S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 11 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10 cm but not exc15 cm long and11 to 15 mm dia of shank complete all as specified and directed. |
| 12 | S&F Galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of posts, straining bolts,standard bolt, including securing or tying at crossing with and including provision of galvanized mild steel wire staples or steel pins, etc complete all as specified and directed (Each line of wire to be measured for the purpose of payment). |
| 13 | Dismantling of AC corrugated / semi corrugated sheet as in roof coverings complete all as specified and directed. |
| 14 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 15 | Excavation in any type of soil for post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed. |
| 16 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 17 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed |
| 18 | M & L Cement concrete type C-2, 1:3:6 using 40 mm graded crushed stone aggreates 50 mm thick as in flooring finished even and fair complete all as specified and directed. |
| 19 | M & L for Screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 20 | M&L chequered cement concrete tiles 20 cm X 20 cm X 25 mm thick, set , jointed and pointed in neat cement surry in floors with pigments complete all as specified and directed. |
| 21 | Hacking out old broken glass panes of any thickness, size ,quality or description from wooden frames, aluminium frame glazed with putty or fixed with beads in repairs complete all as specified and directed. |
| 22 | S&F glass pan ordinary quality 3mm thick and glazing with oil putty/ wooden beads in square n. exc 0.5 m each pane complete all as specified and directed. |
| 23 | Taking down cement plaster of any description including raking outjoints, hackisng for key, scrubbing down with water etc complete all as specified and directed. |
| 24 | M&L for rendering plaster 10 mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surface of ceiling/chajjas etcand finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L for rendering on fair faces of brick workor concrete surfaceof wall 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 26 | M&L rendering 5 mm thick in cement and sand mortar 1:4 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 27 | Dismantling PVC water tanks exc 500 ltr but n. exc 1000 ltr capacity and removing to store complete all as specified and directed. |
| 28 | S&F 500 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified and directed in SSR Part I complete all as specified and directed. |
| 29 | S&F Mild steel framed workas in grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-290, Gde-E-165 complete all as specified and directed. |
| 30 | M&L for preparation of new plastered or unplastered surfaces of wall including removal of vegetation and applying two coat of cement base paint complete all as specified and directed. |
| 31 | M&L for preparation of old plastered surfaces of walls and apply three coat of white wash complete all as specified and directed. |
| 32 | Taking down chowkhats with shutters not exc. 1.5 sqm each complete all as specified and directed. |
| 33 | Taking down chowkhats with shutters exc. 1.5sqm but.not exc. 4 sqm each complete all as specified and directed. |
| 34 | S&F 2nd class Hard wood in plain, solid, straight chowkats and frames wrought framed, rebated on the solid, rounded or chamfered puttogether with glue pinned joints complete all as specified and directed. |
| 35 | S&F Bands, straps, clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming toFe -290 Gde E-165complete complete all as specified and directed. |
| 36 | M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate for fixing of hold fast and making good complete all as specified and directed. |
| 37 | S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides to match complete all as specified and directed. |
| 38 | S&F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes, as per specifications and drawing complete all as specified and directed. |
| 39 | S&FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing shown in section 8 of SSR part -II complete all as specified and directed. |
| 40 | S&F 100mm size butt hinges medium weight (ISI Marked), rolled mild steel complete complete all as specified and directed. |
| 41 | S&F 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed. |
| 42 | S&F 150mm size Aluminium anodizedbarrel Tower bolts of extruded sectionand fixed complete all as specified and directed. |
| 43 | S&F Aluminium alloy, anodized, sliding door bolt (ISI Marked) of 300mm with hasp & staple (Bolt type) and fixing clips of sheets, coat or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 44 | S&F Galvanized mild steel wire-cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 45 | M&LDismantling floot/wall tiling including cement mortar ( but not backing) removing of unserveable tiles from site and rubbish of the premises complete all as specified and directed. |
| 46 | M&L Demolition of cement concrete (un reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 47 | M&L 25 mm thickPCC 1:2:4, type B-0using 12.50mm graded crushed aggregates as in floor surface complete all as specified and directed. |
| 48 | M&L Screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 49 | S&F non skid ceramiccoloured anti skid tiles 300x300x7mm thick in floors etc.Set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 50 | M&L rendering 10mm thick in CM 1:4 to wall as a backing coat to dados complete all as specified and directed. |
| 51 | S&F Glazed ceramic tiles in vertical surface 350X250X7mm / 450X350X7mm thick coloured designedtiles. Set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 52 | Taking up or down steel water tubing and connections of 15 mm bore complete all as specified and directed. |
| 53 | All as per item No 52 above, but 20 mm bore |
| 54 | S&F medium grade galvanised iron 20mm bore with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 55 | All as per item No 54 above,but 15 mm bore |
| 56 | S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with internal footrest (excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 57 | S&F in repair PVC low level flushing cistern (white) 10 Ltrs capacity with internal fitting, push button operated type with and including bracket, PVC flush pipe etc complete all as specified and directed. |
| 58 | S&F Angle valve 15mm bore brass chromium plated with captan head screwed for iron pipe, fixed in repair complete all as specified and directed. |
| 59 | S&F in repair PVCconnection 15 mm bore size, of length 450 mm, with PTMT nuts complete all as specified and directed. |
| 60 | S&F in repairs gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 20 mm bore complete all as specified and directed. |
| 61 | S&F in repair 15 mmfancy type pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered ‘Hot’ or ‘cold’ with long screwed shanks and fly nuts complete all as specified and directed. |
| 62 | S&F in repair 15 mm fancy type stop valve cast copper alloy chromium plated screwed high pressure with crutch or butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube complete all as specified and directed. |
| 63 | S&F in repair 15mm borebib tap cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube complete all as specified and directed. |
| 64 | Taking down existing water proofing membrane and cleaning roof, 15mm thick plastered surface etc preparing the surface to receive plaster by brushing whith wire brush and fanning the surface to remove all loose dirt etc and brushing neat cement slurry @ 3.00 Kg/Sqm including 15 mm thick plastered in cement morter 1:4 withwater proofing comound complete all as specified and directed. |
| 65 | M&L for water proofing treatment for roof slabs by applying bitumen primer @ 0.3 ltr/sqm then applying hot blown bitumen 85/25 @ 1.20kg/sqm and laying 3 mm thickwater proofing membrance modified with glass mat reinforcement weight not less than 3 kg /sqm with overlap of 100 mm and end lap 150 mmand finally applying aluminium based pain on top complete all as specified and directed. |
| 66 | S&F glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat (II nd class hard wood) complete all as specified and directed. |
| 67 | Taking down cover hood of existing rolling shutters(gear operated/ manually size any type ) carefully and completely over hauling the shutters by applying grease and oil in bearing, springs, guide cannels, operating rods, shaft gear boxes, gear wheel etc straightening thoroughly shutter blades, guide channels anchoring rods etc and fixing back the over hood in position and ensure smooth functioning of shutters complete all as specified and directed.(Note : worn out part for replacement will be measured and paid separately.) |
| 68 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 69 | S&F in repairs MS gear box complete incl handle and anchoring rod as of approved quality of steel rolling shutters complete all as specified and directed. |
| 70 | All as per item No 69 above, but Ball bearing suitable for rolling shutter |
| 71 | All as per item No 69 above, but Guide channel 3\" (3.50 mm thick) |
| 72 | All as per item No 69 above, but Hood Cover made of 1 mm thick GI Sheet pattern |
| 73 | All as per item No 69 above,but Bottom plate 5\" (2.25mm) |
| 74 | All as per item No 69 above,butC Class pipe 50 mm dia in shaft |
| 75 | All as per item No 69 above,butAnchoring rod of 25 mm dia of MS pipe |
| 76 | All as per item No 69 above,but Safety lever locks MS with 4 levers |
| 77 | All as per item No 69 above,but MS Curtains of 1 mm thickRolling Shutter consisting of the assembly of lath sections end-locking clips and the connecting pieces at the top complete all as specified and directed. |
| 78 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed. |
| 79 | M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 80 | M&L two coat of synthetic enamel paint over one coat of pink primer including preparation of new wooden surface of any descriptioncomplete all as specified and directed. |
| 81 | M&L two coat of synthetic enamel paint over one coat of pink primer including preparation of old wooden surface of any descriptioncomplete all as specified and directed. |
| 82 | M&L for taking down carefully old UNSV aluminium point wiring with wooden batten /concealed and all accessories of(light, fan, socket or power) such as switches socket ceiling rose, fan regulators, light fitting, main switches DB’s etc and making good disturb surface complete all as specified and directed. |
| 83 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN Dbs/TPN DBs/ Main switch including old unserviceable MCCBs/ MCBs isolators etc and making good to disturbed surface all as specified and directed at site complete all as specified and directed. |
| 84 | Taking down care fully copper/ aluminium sub main wiring of any size from surface / concealed / esisrting conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 85 | M&L for point wiring in repairs with 1.5 Sqmm signle core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size 20/25 MM ISI marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminted 3mm thick sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal incuding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. |
| 86 | All as per item No 85 Above but for Onefan point controlled by one, one way switch. |
| 87 | All as per item No 85 Above but for One exhaust fan point controlled by one, one way switch. |
| 88 | All as per item No 85 Above but for One 5 Amp socket point controlled by one switch on independent board |
| 89 | All as per item No 85 Above but for One 5 Amp socket point controlled by one switch on same board |
| 90 | All as per item No 85 Above but for One light point controlled by two 02 ways switches 5Amp |
| 91 | All as per item No 85 above but with cable PVC insulated 4.0 Sq mmin and including PVC Conduitincl continuous earthing with cable PVC insulated 4.0 Sq mm copper conductor for power socket 15Amps. |
| 92 | M&L for point wiring in repairs with 1.5 Sqmm signle core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including PVC casing capping of size 20/25 MM ISI marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminted 3mm thick sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal incuding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. |
| 93 | All as per item No 92 Above but for Onefan point controlled by one, one way switch. |
| 94 | All as per item No 92 One exhaust fan point controlled by one, one way switch. |
| 95 | All as per item No 92 One 5 Amp socket point controlled by one switch on independent board |
| 96 | All as per item No 92 One 5 Amp socket point controlled by one switch on same board |
| 97 | All as per item No 92 One light point controlled by two 02 ways switches 5Amp |
| 98 | All as per item No 92 above but with cable PVC insulated 4.0 Sq mmin and including PVC Conduitincl continuous earthing with cable PVC insulated 4.0 Sq mm copper conductor for power socket 15Amps |
| 99 | M&L for point wiring with 1.5 Sqmm signle core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size 20/25 MM ISI marked inclusive of tees, bend, elbows etc upto and including GI sunk boxes of size 1.2 mm thick and 60mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switch/ socket of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal incuding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. |
| 100 | All as per item No 99 Above but for Onefan point controlled by one, one way switch. |
| 101 | All as per item No 99Above but for One exhaust fan point controlled by one, one way switch. |
| 102 | All as per item No 99 Above but for One 5 Amp socket point controlled by one switch on independent board |
| 103 | All as per item No 99 Above but for One 5 Amp socket point controlled by one switch on same board |
| 104 | All as per item No 99 Above but for One light point controlled by two 02 ways switches 5Amp |
| 105 | All as per item No 99 above but with cable PVC insulated 4.0 Sq mmin and including PVC Conduitincl continuous earthing with cable PVC insulated 4.0 Sq mm copper conductor for power socket 15Amps. |
| 106 | M&L forin repairs switch socket combination 2-in-1, 5 pin 5 Amp. |
| 107 | M&L for in repairs socket outlet 5 pin 5 Amp. |
| 108 | M&L for in repairs switch socket combination 2-in-1, 5 pin 5 and 15 Amp. |
| 109 | M&L for in repairs switch piano (Flush type) 5 amps, 240 Volts, single pole one way. |
| 110 | M&L for in repairs switch piano (Flush type) 5 amps, 240 Volts, single pole two way. |
| 111 | M&L for in repairs switch piano (flush type) 15 Amps , 240 volts, 50 Hz one way. |
| 112 | M&L for in repairs Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed. |
| 113 | M&L for in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed. |
| 114 | M&L for in repairs Bell push, flush type, 5 amp, 240 volts, 50 Hz |
| 115 | S&F in repairs modular socket 6A , 2/3 pin combined 2 module complete all as specified and directed. |
| 116 | S&F in repairs modular switch6A complete all as specified and directed. |
| 117 | S&F in repairs modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 118 | S&F modular socket 6A / 16A, 2/3 pin combined 2 modulecomplete all as specified and directed. |
| 119 | S&F in repairs modular6A 1 module 2 way switchcomplete all as specified and directed. |
| 120 | S & Fin repairs for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 121 | S & F in repairsfor for Bell push modular 6 Amps single module complete all as specified and directed. |
| 122 | S&F Ceiling rose 3 termianlcomplete all as specified and directed. |
| 123 | S&F Modular switch 2 way 6A, 1 module, 240 volts complete all as specified and directed. |
| 124 | S&F modular white cover plate with frame for module 3 complete all as specified and as directed |
| 125 | All as per item No 124 above, but for 4 module complete all as specified and directed. |
| 126 | All as per item No 124 above, but for 6 module complete all as specified and directed. |
| 127 | All as per item No 124 above, but for 08 module complete all as specified and directed. |
| 128 | S&F Metal flush box 1/2 module complete all as specified and directed |
| 129 | S&F Metal flush box 3 module complete all as specified and directed |
| 130 | S&F Metal flush box 4 module complete all as specified and directed |
| 131 | S&F Metal flush box 6 module complete all as specified and directed |
| 132 | S&F Bakelite Sheetcover plateof size (5x5) complete all as specified and as directed |
| 133 | S&F Bakelite Sheetcover plateof size (8x5) complete all as specified and as directed |
| 134 | S&F Bakelite Sheetcover plateof size (11x13) complete all as specified and as directed |
| 135 | S& F In ReplacementPVC Gang box Square type for fittings complete all as specified and directed |
| 136 | S& F In ReplacementPVC Board box of (4x4) Size complete all as specified and directed. |
| 137 | S& F In ReplacementPVC Board box of (6x8) Size complete all as specified and directed |
| 138 | S& F In ReplacementPVC Board box of (8x10) Size complete all as specified and directed |
| 139 | M&L for in repairs Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed. |
| 140 | S&F repair LED light fitting18/ 20 Watt T5 batten type,PVC extruded batten with decorative end caps complete with polycarbonate /glass tube 4Ft White ,internally pre-wired and including connecting up with suitable twisted flexible copper conductor cable with suitable size.Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 141 | S & F in repair of light fittings (2Ft) with wall mounted LED pattern with polycarbonate housing & integrated electronic driver of 10W cap T5(max lenght upto 600mm) complete all as specified and directed.Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 142 | S&F in repair LED globe light decorative wall light fixture made up of polycarbonate, suitable for 9W LED bulb B22 base complete incl 9 watt bulb complete all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 143 | S&Fin repair aesthetically designed, decorative recess mounted 3Watts (Round) 3000 K spot light for low ceiling height complete all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 144 | S&Fin repair aesthetically designed, decorative recess mounted 5 Watts (Round) 3000 K spot light for low ceiling height complete all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 145 | S&Fin repair aesthetically designed, decorative recess mounted 12 Watts (Round) 6500K spot light for low ceiling height complete all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 146 | S&Fin repair aesthetically designed, decorative recess mounted 06 Watts (Round) 6000K spot light for low ceiling height complete all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 147 | S&F in repairs crysta chip on board (COB) swivel downlight with crisp light throw and high CRI with capacity 3Watts complete 220 volts all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 148 | S&F in repairs crysta chip on board (COB) swivel downlight with crisp light throw and high CRI with capacity 6 Watts complete 220 volts all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 149 | S&F in repairs LED recessed panels with inbuild occupancy sensorwith inbuilt capability of switching on/off basis the occupancy in any space and is perfect for general and office lighting with capacity 36 watts 2x2 ft complete all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 150 | S & F in repairs high efficiency 2x1 ft recess LED flat panel with high brightness LED for glare free homogenous illumnination with capacity 20 watts complete all as specified and directed. Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 151 | S&F in replacement of bldg security light fitting LED type of 25watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 luminaire with high power LEDsas light source and electronic driver. mounting bracketsuitable to house the light fittinhg , with its Galvanised Flat Iron clamps conntected nuts bolts etccomplete all as specified & directed Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 152 | S&F in repairs baybrite flare multi functional LED luminaire of capaity 120 watts complete all as specified and directed.Note : Contractor will write in permt maker CA No and date of instllation on the light fitting |
| 153 | M&L for replacement of 2 Runs of cable PVC insulated but unsheathed 4.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 2.5 Sq mm, stranded copper conductor complete all as specified and directed. |
| 154 | M&Lin replacement of 2 Runs of cable PVC insulated but unsheathed 1.5 Sq mm, stranded copper conductor in and including PVC conduitwith continuous earthing cable PVC insulated 1.0 Sq mm, stranded copper conductorcomplete all as specified and directed.Note : 2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre. |
| 155 | M&Lin replacement of 2 Runs of cable PVC insulated but unsheathed 2.5 Sq mm, stranded copper conductor in and including PVC conduitwith continuous earthing cable PVC insulated 1.5 Sq mm, stranded copper conductorcomplete all as specified and directed.Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre. |
| 156 | M&L replacement of 2 Runs of cable PVC insulated but unsheathed 6.0 Sq mm, stranded copper conductor in and including PVC conduitwith continuous earthing cable PVC insulated 4.0 Sq mm, stranded copper conductorcomplete all as specified and directed.Note : 2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre. |
| 157 | M&Lreplacementof 2 Runs of cable PVC insulated but unsheathed 10 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 6.0 Sq mm, stranded copper conductorcomplete all as specified and directed.Note : 2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre. |
| 158 | S& F In Replacement3 core 1 Sqmm round Sheathed copper wire complete all as specified and directed |
| 159 | S&F in replacement sheet metal enclosure vertical DBs with provision for FP MCCB frame upto 100A in 16,KAas incomer4 waydouble door madecomplete all as specified and directed. |
| 160 | S&F replacement sheet metal enclosure double doorMCB DB, 220 volts, SPN 12 way complete all as specified and directed. |
| 161 | S&F replacement sheet metal enclosure double doorMCB DB 220 Volts, SPN 8 way complete all as specified and directed. |
| 162 | S&F replacement sheet metal enclosure double doorMCB DB 220 volts , TPN 4 way complete all as specified and directed. |
| 163 | S&F replacement sheet metal enclosure double doorMCB DB 415 Volts, TPN 8 way complete all as specified and directed. |
| 164 | S&F replacement sheet metal enclosure double doorMCB DB 415 Volts, TPN 12 way complete all as specified and directed. |
| 165 | S&F in repairs 5-32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) Single pole to be fixed in DB complete with connection testing and commissioning. |
| 166 | S&F in repairs 32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) Single pole neutralto be fixed in DB complete with connection testing and commissioning. |
| 167 | S&F in repairs 40-63 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) Single pole neutralto be fixed in DB complete with connection testing and commissioning. |
| 168 | S&F in repairs MCCB 4 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed |
| 169 | S&F in repairs MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed |
| 170 | S&F in repairs 415V 10KA \"C\" curve miniature circuit breaker (MCB) TPN 16 to 32 Amps current carrying capacity in the DB complete with connection testing and commissioning. |
| 171 | S&F in repairs 415V 10KA \"C\" curve miniature circuit breaker (MCB) TPN TPN 40 To 100 AMPs current carrying capacity in the DB complete with connection testing and commissioning. |
| 172 | S&F in replcment of single pole and neutral enclosure with a two pin and earth plug socket 240 V with one MCB SP ‘C’ series rating 20 to 30 Amp complete all as specified and directed. |
| 173 | M&L replacement for earthing with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground(earth pit not less than 2.25 mtrs deep below ground level)with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers protected with & including 15 mm dia light grade GI pipenecessary excavation and earth works, charcoal and common salt filling, watering arrangement with 20 mm GI pipe light gradeincluding PCC pit with Pre cast RCC (1:2:4) cover, GI funnel with mesh test point, testing & commissioning complete all as specified and directed. |
| 174 | Supply testing and commissioning AC three phase ,3x 240V ,50Hz, digital,electronictamper proof energy meter of rating 10 to 60 Amps covered with PVC transparent cover with optical communication port incl taking down the unsv meter complete all as specified and directed. |
| 175 | Supply testing and commissioning AC single phase,50Hz, digital,electronictamper proof energy meter of rating 5 to 30 Amps covered with PVC transparent cover with optical communication port incl taking down the unsv meter complete all as specified and directed. |
| 176 | Supply, testing and commissioning in repairs serviece wire 6 Sqmm 2 core aluminium conductor PVC insulated 240 volts, 50 Hz complete all as specified and directed. |
| 177 | Supply, testing and commissioning in repairs serviece wire 4 Sqmm 2 core aluminium conductor PVC insulated 240 volts, 50 Hz complete all as specified and directed. |
AI Tender Summary
Tender Timeline
Sep 03, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedSep 23, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 26, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
Completed