Developement Of Distribution Infrastructure For Loss Reduction In Distt Mandi Hp Under Rdss Developement Of Distribution Infrastructure For Loss Reduction In Distt Mandi Hp Under Rdss , Schedule-I ( Supply Part ) , New Dtr 11 / 22 Kv ( Hvds, mandi-Himachal Pradesh

Himachal Pradesh State Electricity Board-HPSEB has published Developement Of Distribution Infrastructure For Loss Reduction In Distt Mandi Hp Under Rdss Developement Of Distribution Infrastructure For Loss Reduction In Distt Mandi Hp Under Rdss , Schedule-I ( Supply Part ) , New Dtr 11 / 22 Kv ( Hvds. Submission Date for this Tender is 03-10-2022. Coats and Jackets Tenders in mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33777682
Corrigendum : Developement Of Distribution Infrastructure For Loss Reduction In Distt Mandi Hp Under Rdss Developement Of Distribution Infrastructure For Loss Reduction In Distt Mandi Hp Under Rdss , Schedule-I ( Supply Part ) , New Dtr 11 / 22 Kv ( Hvds
Open Tender
Indian
Himachal Pradesh
mandi
03-10-2022

Tender Details

Developement Of Distribution Infrastructure For Loss Reduction In Distt Mandi Hp Under Rdss Developement Of Distribution Infrastructure For Loss Reduction In Distt Mandi Hp Under Rdss , Schedule-I ( Supply Part ) , New Dtr 11 / 22 Kv ( Hvds, Feeder Bifurcation, Feeder Segregation And Extension Of New Ht, Dt, Lt As Per Technical Specification, Approved Drawings And Scope Of Work. , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Is 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Pre-Fabricated Galvanised Steel ( Zinc Coating 610Gms / Sqm ) , Items Like Dc Cross Arm ( 100X50x6 Mm ) , Back Clamps ( 50X6 Mm ) , Pole Clamp ( 65X8 Mm ) , Do Fuse Mounting Channel ( 75X40x6 Mm ) , Transformer Mounting Channel ( 100X50x6 Mm ) , Transformer Clamping Set ( 50X50x6 Mm ) , Transformer Belting Set ( 50X50x6 Mm ) As Per Technical Specification, Approved Drawings And Scope Of Work. , Gs Nuts, Bolts With Washers As Per Technical Specification, Approved Drawings And Scope Of Work. , Stay Set ( Galvanised ) With 50X8 Mm Stay Clamp, Guy Insulator ( 1Nos. ) , Anchor Plate ( 200X200x6mm ) , Nut Bolts, 2 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. , 11 Kv Disc Insulator B&S Type Conformimg To Is-731 / 1971 All Latest Version Thereof For Suspension & Tension String Ball And Socket Type Having Pin Ball. The Minumum And Maximum Creepage Distance With Diameter Of Insulator- 255 Mm & Having Electromechanical Strength 90Kn. The Insulator Shall Have W Type Phosphors Bronze Security Clips For Ball Socket Porcelain Conforming Is: 2486-1971 ( 90Kn ) Complete In All Respect. Heavilypolluted Atmospheres Creepage Distance-400 Mm , 22 Kv Disc Insulator B&S Type ( 2 Nos. Disc ) Conformimg To Is-731 / 1971 All Latest Version Thereof For Suspension & Tension String Ball And Socket Type Having Pin Ball. The Minumum And Maximum Creepage Distance With Diameter Of Insulator- 225 Mm & Having Electromechanical Strength 90Kn. The Insulator Shall Have W Type Phosphors Bronze Security Clips For Ball Socket Porcelain Conforming Is: 2486-1971 ( 90Kn ) Complete In All Respect. Heavily Polluted Atmospheres Creepage Distance400 Mm , Distribution Transformer Substation Using New Outdoor Type, Oil Immersed, Distribution Transformer Up To And Including 630 Kva As Per Is1180 ( Part-1 ) : 2014 And Its Amendments 1, 2, 3 And 4, Rgo / Amorphous Core, Energy Efficiency Level 1, Carrying Bureau Of Indian Standard Certificate Mark, In Following Preferred Ratings As Per Detailed Scope Of Work And Technical Specifications: , 22 / 0.230 Kv Distribution Transformer 10 Kva 3Phasedtr , 11 / 0.230 Kv Distribution Transformer 16 Kva 3 Phase Dtr , 11 / 0.4 Kv Distribution Transformer 25 Kva 3 Phase Dtr , 22 / 0.4 Kv Distribution Transformer 25 Kva 3 Phase Dtr , 11 / 0.4 Kv Distribution Transformer 63 Kva 3 Phasedtr , 22 / 0.4 Kv Distribution Transformer 63 Kva 3 Phase Dtr , 11 / 0.4 Kv Distribution Transformer 100 Kva 3 Phase Dtr , 22 / 0.4 Kv Distribution Transformer 100 Kva 3 Phasedtr , 11 / 0.4 Kv Distribution Transformer 250 Kva 3 Phasedtr , Outdoor Mounting Type Distribution Box Made Of Ms Sheet Of Thickness Not Less Than 18 Swg Crca Sheet / Smc Distribution Box, Dust And Moisture Vermin, Weather Proof With Degree Of Protection With Suitable Bus Bars, Earthing Cum Neutral Bus, Earthing Terminals, Box Illumination, Front Door Operated With Proper Locking Arrangement, Lugs, Mounting Channel Frame, Internal Wiring With Frls Cables, Danger Plate, Numbering, Back Clamps, Hardware As Per Scope Of The Work, Technical Specifications And Approved Drawings Suitable For Following Transformer: , 3 Ph 10Kva Transformer 80 A Tpn Mccb ( Incomer ) And 2 Nos. 50 A Sp Mccb ( Outgoing ) , 3 Ph 16 Kva Transformer 80 A Tpn Mccb ( Incomer ) And 2 Nos. 50 A Sp Mccb ( Outgoing ) , 3 Ph 25 Kva Transformer 40 A Tpn Mccb ( Incomer ) And 6 Nos. 25 A Sp Mccb ( Outgoing ) , 3 Ph 63 Kva Transformer Having 200 A Tpn Isolator, 100 A Hrc Fuse ( Incomer ) And 6 Nos. 60 A Sp Mccb ( Outgoing ) , 3 Ph 100 Kva Transformer Having 200 A Tpn Isolator, 160A Hrc Fuse ( Incomer ) And 6 Nos. 90 A Sp Mccb ( Outgoing ) , Lt Distribution Panel Box Suitable For 250Kva S / Stn Of Size 1100X800x275mm + / - 5% Made Of Steel Sheet Of 1.63 Mm Thickness Having Doubledoor Locking Arrangement Duly Powder Coated Painted Complete With 2 No. Mccbs ( 1Main + 1 Spare ) Rating 400Amp, 3 Poles Having Following Specifications ( 1 ) Minimum Frame Size 400Amp ( 2 ) Type Variable Trip Free, ( 3 ) Breaking Capacity- Isu & Lcs At 415, 50 Hz ( Ka: Not Less Than 50 Ka ) ( 4 ) , Thermal Release Range: 320-440Amp ( 5 ) Mecanicallife ( Operation ) 20000 No. ( 6 ) Electrical Life ( Operation ) 4000 No. ( 7 ) Rated Insulation Voltage ( V ) 690V ( 8 ) Tripping Thermal Releasing Setting : Thermal-O / L Variable Setting ( 9 ) Tripping Magnetic Releasing Setting : Magnetic- S / C Fixed Setting ( 12 ) In ( 10 ) ( Operation ) Volatge 415V, Ac ( 11 ) Caliberation Temperature: 40 Degree C ( 12 ) High Voltage Withstand Voltage : 3Kv For 1 Minute ( 13 ) Confirming To Is : 1993 / 60947-2, 1989 ( 14 ) Make L&T / Havells / Abb / Hpl / Schneider ( 15 ) Ics : 100% Icu , 9Kv, 10 Ka Porcelain Station Surge Arrestor / Lightening Arrestorcomplete With Accessories For 11Kv System , 18 Kv, 10 Ka Porcelain Station Surge Arrestor / Lightening Arrestorcomplete With Accessories For 22 Kv System , 11 Kv, 3-Ph, 400 A, 3 Pin Type, Horizontal / Vertical Mounting Type ( As Desired By Discom ) , Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 22 Kv, 3-Ph, 400 A, 3 Pin Type, Horizontal / Vertical Mounting Type ( As Desired By Discom ) , Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 11 Kv, 3-Ph, Drop Out Fuse Units ( Set Of 3 Units ) Along With Support Insulators, Base Channel, Fuse Barrel Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 22 Kv, 3-Ph, Drop Out Fuse Units ( Set Of 3 Units ) Along With Support Insulators, Base Channel, Fuse Barrel Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 3 Nos Pipe Earthing Using 40Mm Dia Gi Pipe 3000 Mm Long, Making Earth Grid Using 50X6mm Gi Flat And Riser As Per Scope Of Work Of Distribution Transformer Substations, As Per Scope Of Work, Approved Drawings And Technical Specifications, , 8 Swg Gi Wire For Earthing As Per Technical Specifications, Approved Drawings And Scope Of Works. , Pvc 3.5 Core Aluminium Conductor, Stranded, Unarmoured Cable I / C Thimbles Of Suitable Size For Connection Of Transformer Lv Bushing To Distribution Box And Distribution Box To Overhead Line I / C Proper Clamping Clamping Of Cablesas Per Scope Of Work, Technical Specification And Approved Drawings: , 3.5 Cx16 Sqmm Aluminium Conductor Cable , 3.5 Cx35 Sqmm Aluminium Conductor Cable , 3.5Cx70 Sqmm Aluminium Conductor Cable , 3.5Cx120 Sqmm Aluminium Conductor Cable , 3.5Cx185 Sqmm Aluminium Conductor Cable , Danger Plate Size: 250X200x1.6 Mm Made Of Mild Steel Plates 1.6 ( Minimum ) Thick Vitreous Enameled White Letter Figure, Conventional Skill And X-Boxes And Signal Red Colour On Front Side For Use In Hpsebl. The Rear Side Of The Plate Shall Be Black Enameled And Conforming To Is Specifiction No. Is-1351 / 1982 Suitable For 11 / 22Kv System , Galvanised Steel Barbed Wire Of 9.8 Kg / 100Metre , Aluminium Paint For All Poles And Steel Fitting , Red Oxide , 3 Kvar Power Factor Correction Capacitor Along With Mc O Capacitor Duty Contractorfor New 25 Kva , 11 / 0.4 Kv Dtr , 7 Kvar Power Factor Correction Capacitor Along With Mc O Capacitor Duty Contractorfor New 63 Kva , 11 / 0.4 Kv Dtr , 10 Kvar Power Factor Correction Capacitor Along With Mc O Capacitor Duty Contractorfor New 100 Kva , 11 / 0.4 Kv Dtr , Acsr Rabbit Conductor For Jumpering Including Pg Clamps, Bi- Metallic Connectors, Hardware Etc As Per Technical Specifications, Approved Drawings And Scope Of Works. , New Lt Line 3 Ph 4 Wire Rabbit , Support For Lt Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work. , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Is 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Galvanised Stay Set With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 2 Nos Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. , Earthing As Per Approved Drawings, Technical Specifications And Scope Of Work , 40 Mm Dia., 3000 Mm Long Gi Pipe Earth Electrode With Test Link, Rcc Pit, Rcc Cover Plates On Gi Frame, Bentonite Powder And Spike Earthing 20Mm Solid Rod I / C Other Accessories Complete , 8 Swg Gi Wire For Earthing & Gi Nuts, Bolts & Washers , Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work , 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit , Angle Iron ( 75X75x6 ) [ Length- 1.50 Mtr + 0.02 Mtr ] , Shackle Insulator ( 16 Kn ) , D-Iron ( U- Clamps ) , Earth Knob , Kit Kat I.C , Full Clamps [ 2 No For A.I + 1 No For Stay Set ] , Spool Tie , Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] , Aluminium Paint , Spiral Pvc Spacer , Red Oxide , New Lt Line 1 Ph 2 Wire Rabbit , Support For Lt Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work. , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Is 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Galvanised Stay Set With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 2 Nos Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. , Earthing As Per Approved Drawings, Technical Specifications And Scope Of Work , 40 Mm Dia., 3000 Mm Long Gi Pipe Earth Electrode With Test Link, Rcc Pit, Rcc Cover Plates On Gi Frame, Bentonite Powder And Spike Earthing 20Mm Solid Rod I / C Other Accessories Complete , 8 Swg Gi Wire For Earthing & Gi Nuts, Bolts & Washers , Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work , 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit , Angle Iron ( 75X75x6 ) [ Length- 1.50 Mtr + 0.02 Mtr ] , Shackle Insulator ( 16 Kn ) , D-Iron ( U- Clamps ) , Earth Knob , Kit Kat I.C , Full Clamps [ 2 No For A.I + 1 No For Stay Set ] , Spool Tie , Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] , Aluminium Paint , Spiral Pvc Spacer , Red Oxide , Augmentation & Renovation Of 11 / 0.4 Kv Distribution Transformer Substation , Augmentation Of Distribution Transformer Substation Using New Outdoor Type, Oil Immersed, Distribution Transformer Up To And Including 630 Kva As Per Is1180 ( Part-1 ) : 2014 And Its Amendments 1, 2, 3 And 4, Crgo / Amorphous Core, Energy Efficiency Level 1, Carrying Bureau Of Indian Standard Certificate Mark, In Following Preferred Ratings As Per Detailed Scope Of Work And Technical Specifications Under: , New 63 Kva ( 11 / 0.4 Kv ) Dtr ( Replacing 25Kva Old Dtr ) , , New 63 Kva ( 22 / 0.4 Kv ) Dtr ( Replacing 25Kva Old Dtr ) , , New 100 Kva ( 11 / 0.4 Kv ) Dtr ( Replacing 63 Kva Old Dtr ) , , New 100 Kva ( 22 / 0.4 Kv ) Dtr ( Replacing 63 Kva Old Dtr ) , , New 250 Kva ( 11 / 0.4 Kv ) Dtr ( Replacing 100 Kva Old Dtr ) , , New 250 Kva ( 22 / 0.4 Kv ) Dtr ( Replacing 100 Kva Old Dtr ) , , New 400 Kva ( 11 / 0.4 Kv ) Dtr ( Replacing 250 Kva Old Dtr ) , , New 400 Kva ( 22 / 0.4 Kv ) Dtr ( Replacing 250 Kva Old Dtr ) , , New 630 Kva ( 11 / 0.4 Kv ) Dtr ( Replacing 400 Kva Old Dtr ) , , New 630 Kva ( 22 / 0.4 Kv ) Dtr ( Replacing 400 Kva Old Dtr ) , , Augmentation Of Dtr Substation By Using New 3.5 C Pvcaluminium Conductor, Stranded, Unarmoured Cable For Connection Of Transformer Lv Bushing To Distribution Box And Distribution Box To Overhead Line As Per Scope Of Work, Technical Specification And Approved Drawings. Replaced Cables To Be Deposited In Employers Store. , 3.5 Cx70 Sqmm Aluminium Conductor Cable , 3.5Cx120 Sqmm Aluminium Conductor Cable , 3.5Cx185 Sqmm Aluminium Conductor Cable , 3.5Cx300 Sqmm Aluminium Conductor Cable , 3.5Cx400 Sqmm Aluminium Conductor Cable , Augmentation Of Dtr Substation By Using New Outdoor Mounting Type Distribution Box Made Of Ms Sheet Of Thickness Not Less Than 1.8 Mm / Smc Distribution Box, Dust And Moisture Vermin, Weather Proof With Degree Of Protection Ip 33 As Per Is 13947 With Suitable Bus Bars, Earthing Bus, Earthing Terminals, Box Illumination, Front Door Operated With Proper Locking Arrangement, Non Magnetic 4 Mm Thick Gland Plate, Double Compression Brass Cable Glands, Lugs, Mounting Channel Frame, Internal Wiring With Frls Cables, Danger Plate, Numbering, Back Clamps, Hardware As Per Scope Of The Work, Technical Specifications And Approved Drawings Suitable For Following Transformer: , 3 Ph 63 Kva Transformer Having 200 A Tpn Isolator, 100 A Hrc Fuse ( Incomer ) And 6 Nos. 60 A Sp Mccb ( Outgoing ) , 3 Ph 100 Kva Transformer Having 200 A Tpn Isolator, 160A Hrc Fuse ( Incomer ) And 6 Nos. 90 A Sp Mccb ( Outgoing ) , Lt Distribution Panel Box Suitable For 250Kva S / Stn Of Size 1100X800x275mm + / - 5% Made Of Steel Sheet Of 1.63 Mm Thickness Having Doubledoor Locking Arrangement Duly Powder Coated Painted Complete With 2 No. Mccbs ( 1Main + 1 Spare ) Rating 400Amp, 3 Poles Having Following Specifications ( 1 ) Minimum Frame Size 400Amp ( 2 ) Type Variable Trip Free, ( 3 ) Breaking Capacity- Isu & Lcs At 415, 50 Hz ( Ka: Not Less Than 50 Ka ) ( 4 ) , Thermal Release Range: 320-440Amp ( 5 ) Mecanicallife ( Operation ) 20000 No. ( 6 ) Electrical Life ( Operation ) 4000 No. ( 7 ) Rated Insulation Voltage ( V ) 690V ( 8 ) Tripping Thermal Releasing Setting : Thermal-O / L Variable Setting ( 9 ) Tripping Magnetic Releasing Setting : Magnetic- S / C Fixed Setting ( 12 ) In ( 10 ) ( Operation ) Volatge 415V, Ac ( 11 ) Caliberation Temperature: 40 Degree C ( 12 ) High Voltage Withstand Voltage : 3Kv For 1 Minute ( 13 ) Confirming To Is : 1993 / 60947-2, 1989 ( 14 ) Make L&T / Havells / Abb / Hpl / Schneider ( 15 ) Ics : 100% Icu , Lt Distribution Panel Box Suitable For 400Kva S / Stn. Made Of Steel Sheet Of 1.63 Mm Thickness Having Doubledoor Locking Arrangement Duly Powder Coated Pained Complete With Acb Rating 1000Amp, Duty Circle 0.3 Sec, Rating Symmetrical Breaking Capacity 50Ka, Service Breaking Capacity 100% Icu, Rating Making Capacity 105Ka Peak, Short Circuit Time For Seconds ( Ka Rms ) 50Ka, Thermal Current Set Value 1000 Amp, Time For Which Breaker Can Carry Its Rating Breaking Current <40 Ms, Endurance ( Co ) Cycle Mechanical Not Less Than 8000 Operations, Electrical Not Less Than 5000 Operations, Electrical Life For Arcing Contacts Not Less Than 2500 Operations, Insultion Voltage 1100 Volts, Impulse With Stand Voltage 8Kv, Closing Mechanism Mannual Independent Mannual, Version Required Fixed And Make L&T / Havells / C&S / Hpl / Schneider , Lt Distribution Panel Box Suitable For 630Kva S / Stn. Made Of Steel Sheet Of 1.63 Mm Thickness Having Doubledoor Locking Arrangement Duly Powder Coated Pained Complete With Acb Rating 1000Amp, Duty Circle 0.3 Sec, Rating Symmetrical Breaking Capacity 50Ka, Service Breaking Capacity 100% Icu, Rating Making Cap. 105Ka Peak, Short Circuit Time For Seconds ( Ka Rms ) 50Ka, Thermal Current Set Value 1000 Amp, Time For Which Breaker Can Carry Its Rating Breaking Current <40 Ms, Endurancec ( Co ) Ciycle Mechanical Not Less Than 8000 Operations, Electrical Not Less Than 5000 Operations, Electrical Life For Arcing Contacts Not Less Than 2500 Operations, Insulation Voltage 1100 Volts, Inpulse With Stgand Voltage 8Kv, Closing Mechanism Mannual Independent Mannual, Version Required Fixed And Make L&T / Havells / C&S / Hpl / Schiender. , Renovation Of Dtr Substation Earthing As Per Technical Specification, Approved Drawings And Scope Of Work: , Revamping Of Distribution Transformer Substation Earthing By Using 40 Mm Dia 3 Meter Long Gi Pipe Earthing, Using 50X6 Mm Gs Flat For Earth Mat And Riser And 25X3mm Gs Flat For Connecting Equipment, Using 200 Kg Bentonite Powder Of Substation In Normal Soil , Augmentation Of Dtr Substation By New Pre-Fabricated Galvanised Steel Items Like Dc Cross Arm ( 100X50x6 Mm ) , Back Clamps ( 65X8 Mm ) , Pole Clamp ( 65X8 Mm ) , Do Mounting Channel ( 75X40x6 Mm ) , Transformer Mounting Channel ( 100X50x6 Mm ) , Transformer Clamping Set ( 50X50x6 Mm ) , Transformer Belting Set ( 50X50x6 Mm ) As Per Technical Specification, Approved Drawings And Scope Of Work. , Augmentation Of Dtr Substation By New Galvanised Steel ( Gs ) Nuts, Bolts With Washers As Per Technical Specification, Approved Drawings And Scope Of Work. , Augmentation Of Dtr Substation By New 9Kv, 11 Ka Distribution Class Lightening Arrester For Dt As Per Technical Specification, Approved Drawings And Scope Of Work. , Augmentation Of Dtr Substation By 18 Kv, 10 Ka Porcelain Station Surge Arrestor / Lightening Arrestorcomplete With Accessories For 22 Kv System , Augmentation Of Dtr Substation By New 11 Kv, 3-Ph, 200 A, 3 Pin Type, Vertical Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , Augmentation Of Dtr Substation By New22 Kv, 3-Ph, 400 A, 3 Pin Type, Horizontal / Vertical Mounting Type ( As Desired By Discom ) , Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , Aluminium Paint For Substaion Structure And Steel Fitting , 11Kv, 200 A, 3-Ph Drop Out Fuse Assembly Including Insulators And Mounting Arrangements, Jumpering From Bus Bar, Hardware, Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. , 22 Kv, 3-Ph, Drop Out Fuse Units ( Set Of 3 Units ) Along With Support Insulators, Base Channel, Fuse Barrel Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , Conversion Of Existing Lt Bare Conductor Line With Following Arrangements Using New Areal Bunched Xlpe Cable, Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral, Piercing Connectors Type-I & Type-Ii, 16 Mm Dia Ms Nuts & Bolts, Pole Clamps, Spring Loaded Bus Bar Suitable For Single Phase And Three Phase Systems Etc. As Required As Per Technical Specification, Approved Drawings And Scope Of Work: , Aerial Bunchedcable 3 X 70+50+16 Sq.Mm , Lt Ab Cable Cable On Poles [ Size: 3 X 70+50+16 Sq.Mm { Additional 1% Sagging & Wastage ) , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Is 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Galvanised Stay Set With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 2 Nos Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. , Half Clamp For Cross Arm , Anchoring Assembly For Lt , Suspension Assembly For Lt , Facade Hooks For Lt , Distribution Boxes , Earthing Set Complete , Red Oxide , Aluminium Paint , Augmentation Of 33 / 11 Kvfully Outdoor Type Substation , 33 / 11 Kv, 3 Ph, 50 Hz, Onan, Cu Wound, Outdoor Conventional Type Power Transformer Along With Transformer Oil, Buchholtz Relay, Breather, Oti & Wti, Marshalling Box, Conservator Tank, Oil Level Indicator, Valves, 2 Sets Of 50X8 Mm Gs Neutral Earthing Strips { ( With Braided Conductor On Bushing End ) , Isolating Link, Isolation With Insulators } , Vent Explosion Plug, Control Wiring Between Sensing Equipment And Marshalling Box, Cable Supporting Tray On The Body Of Transformer, Transformer Wheels, Lv / Hv Bushing Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Work. , 3.15 Mva Without Tap Changer , 6.30 Mva With Off Load Tap Changer , 33Kv Superstructure Andequipment Structure , Galvanised Super Structure Comprisinggantries And Columns , Galvanised Equipment Structure For Mounting 33Kv Isolators And Post Insulators , 36Kv, 1250A, 25Ka For 3 Seconds, 3-Ph, Outdoor Type Vacuum Circuit Breaker Along With 36Kv, 1-Phase, 25Ka / 3 Seconds, 200-100 / 5-5 Amps Or 300-150 / 5-5 Amps 1 Set ( 3 Nos ) Outdoor Type Current Transformers Along With Junction Box ( 1 No Junction Box For 3 No Of 1-Phase Cts ) , Jumpers, Earthing, Supporting Structures, Bi- Metallic Clamps, Permanent Maintenance Platform, Marshalling Box Etc Required As Per Technical Specifications, Scope Of Works And Approved Drawings , 33 Kv , 1250A , 25 Ka For 3Sec Auto Reclosure ( O / D Channel Mounted ) With Built In Feederprotections, Communicable For Remote Operation Through Scada System Iec 61850 , 104Compatible , 33 Kv , 1250A , 25 Ka For 3Sec Auto Reclosure ( O / D Channel Mounted ) With Built In Power Transformer Protections, Communicablefor Remote Operation Through Scada System Iec 61850 , 104 Compatible , 33Kv, Indoor, Control & Relay Panel Along With E / F & O / C Relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays And Other Components Etc As Per Approved Drawings, Specifications And Scope Of Works Controlling: , 33 Kv Feeder Panel ( 33 Kv Incomer Bus ) [ Numeric Relay, Iec 61850 ] , Power Transformerprotection Panel ( With Numericdifferential Relay / Ref Relay , Iec 61850 ) , 36Kv, 1250A, 25Ka For 3 Seconds, 3-Ph Double Break Center Rotating Type ( Dbcr ) , Gang Operated Motorised Isolator Along With Support Insulators, Operating Mechanism, Base Channel Down Pipe And All Required Accessories Complete As Per Technical Specifications, Scope Of Works And Approved Drawings With Out Earth Switch. , 36Kv, 1250A, 25Ka For 3 Seconds, 3-Ph Double Break Center Rotating Type ( Dbcr ) , Gang Operated Motorised Isolator Along With Support Insulators, Operating Mechanism, Base Channel Down Pipe And All Required Accessories Complete As Per Technical Specifications, Scope Of Works And Approved Drawings With Earth Switch , 30 Kv, 10Ka, 1-Ph Station Class Lightening Arrester With Surge Counter, Mounting Platform, Jumpering From Bus Bar, Earthing Connection Using 50X6mm Gs Flat, Hardware Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. , 9Kv, 10Ka, 1-Ph Station Class Lightening Arrester With Mounting Platform, Jumpering From Bus Bar, Earthing Connection Using 50X6mm Gs Flat, Hardware, Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. , Indoor Type Control And Relay Panel As Per Technical Specifications, Approved Drawings And Scope Of Works: , Indoor Type Control And Relay Panel For 11Kv, 3Phase, 1250 A Vcb ( Transformer Breaker ) Consisting Of Ct 800-400 / 1-1-1 A, Pt 11000 / 110 V-Meter, Volt-Meter, Relays & Accessories Complete As Per Specifications For Transformer Breaker Protection ( 12 Kv, 1250 A, 25Ka ) [ Numeric Relay, Iec 61850 ] , Indoor Type Control And Relay Panel For 11 Kv 3 Phase, 1250 A Vcb ( Feeder Breakers ) Consisting Of Ct 400-200 / 1-1-1 A , 11000 / 110 V -Meter, Volt-Meter, Relays, Energy Meter ( Tvm ) & Accessories Complete As Per Specifications For Feeder Breaker Protection ( 12 Kv, 1250 A, 25Ka ) [ Numeric Relay, Iec 61850 ] , 12 Kv, 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breakeralong With 12 Kv, 1-Phase, 800-400 / 1-1-1 , 3 Nos Indoor Type Current Transformer, Indoor Mounting Type Control Panel For Bus Coupler, Control Cabling Between Vcb And Indoor Control Panel And Required Accessories, Bi-Metallic Clamps, A-Meter, Volt-Meter, 3- Phase Electronic Energy Meter, Relay & Accessories Complete As Per Specifications For Bus Coupler Protection ( 12 Kv, 1250 A, 25Ka ) ( Numeric Relay , Iec 61850 ) , Numerical Directional Relay For 33 Kv Feeder Protectionwith Iec 61850 Complitant With Rj 45 Port , Numerical Directional Relay For 11 Kv Feeder Protectionwith Iec 61850 Complitant With Rj 45 Port , Numerical Differentialrelay For Transformer Protection On 11 Kv Incomer With Iec 61850 Compliant With Rj 45 Port , 11 Kv , 800 A , 25 Ka For 3Sec Auto Reclosure ( O / D Channel Mounted ) With Built In Feederprotections, Communcablefor Remote Operation Through Scada System Iec 61850 , 104 Compatible , 30 V, 100 Ah Pb Acid Battery, Battery Stand Made Of Teak Wood Duly Painted With Anti Rusting Paint, Battery Insulators, Inter-Battery Wiring Using 30 Sqmm, 1.1 Kv, Copper Single Core Multi Strand Cable, Terminal Connectors, & All Other Accessories And Connectors And 30V, 40 Amp. ( Or As Per State Practice ) Float-Cum-Boost Battery Charger With Six Wave Rectification For 440 V, 3 Phase, 50 Hz Ac Input Supply As Per Technical Specifications, Approved Drawings And Scope Of Works , Acsr Conductor For Bus-Bars & Jumpers / Droppers / Terminations Including Hardware Fittings, Hardware, T-Claimp Etc As Per Technical Specifications, Approved Drawings And Scope Of Works , 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther , Earthing & Grounding Conductor As Per Approved Electrical Layout For Each Sub-Station As Per Technical Specifications, Approved Drawings And Scope Of Works With , 65 X 8 Mm Gi Flat For Ground Mat , 50 X 6 Mm Galvanized Gi Flat ( Risers ) , 25Mm Dia Gi Rod 3 M Long For Earth Mat , 50 Mm Dia., 3000 Mm Long Gi Pipe Earth Electrode With Test Link, Rcc Pit, Rcc Cover, Placed On Gi Frame, Bantonide Powder And Other Accessories Complete As Per Technical Specification. ( For Power Transformer Neutral, Station Transformer Neutral And Lightening Arresters Direct Earthing ) As Per Technical Specifications, Approved Drawings And Scope Of Works. , 33 Kv Post Insulators Along With Strurcture, Suitable Hardware & Accessories Suitable For Panther / Dog Conductors As Per Approved Drawings & Specifications. , Control Cables Including Their Termination Materials Like Glands, Lugs Etc. As Per Technical Specifications, Approved Drawings And Scope Of The Work. , 2 Core 2.5 Sqmm Armoured, Stranded Copper Conductor, Pvc Insulated And Pvc Sheathed Cable , 10 Core 2.5 Sqmm Armoured, Stranded Copper Conductor, Pvc Insulated And Pvc Sheathed Cable , 12 Core 2.5 Sqmm Armoured, Stranded Copper Conductor, Pvc Insulated And Pvc Sheathed Cable , 7Core 6.0 Sqmm Armoured, Stranded Copper Conductor, Pvc Insulated Screened And Pvc Sheathed Cable , 4 Core 6.0 Sqmm Armoured, Stranded Copper Conductor, Pvc Insulated Screened And Pvc Sheathed Cable , 3Core 400 Sqmm Xlpe , Al , Armoured , Cable , Lt Power Cable Pvc 1.1 Kv , 4 Core, Al , 16 Mm2, Un-Armoured , 11Kv , Xlpe , Outdoor Type 3X 400Sqmm Termination Kit , 11Kv , Xlpe , Indoor Type 3X400sqmm Termination Kit , 11 Kv Isolator Motorised ( 12 Kv, 630A, 25 Ka With Earthswitch Outdoor ) , 11.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-56. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Is 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) , Extension Of 33Kv And 11 Kvcontrol Bays , Rs Joists Size 12800X250x125 Mm , Ms Channel Iron 125X65x6, X-Arms @ 12.1 Kg / M, 7 Mtr Long, 5.5Mtr Long , Msai 50X50x6 Mm For 33 And 11 Kv Yard , Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) ( With Flat And Spring Washers ) ] , Bus Bar , I ) 33 Kvdisc Insulator Tension Stringcomplete , Ii ) 33 Kv Disc Suspension Tension String Complete , Acsr Conductor 200Sqmm @ 10% , Pg Clamps , Sub Station Automation System ( Scada ) With Necessary Hardware And Software And Any Modification / Retro-Fitting In Existing Control And Monitoring System Of 33Kv / 11Kv Switch Gears And Equipments , Field Sensors , Transducers , Limit Switches And Wiring, Ups Having Capacity Of 02 Kva With 1 Hour Battery Backupfor Complete Control, Monitoring And Data Logging Ofsub-Stations Along With Substattion Survelliance System Including Ip Cameras And Nvri P Phones Etc. At Thalout Substation , Tanihar And Sandhole Substation , Sub Station Automation System ( Scada ) With Necessary Hardware And Software And Any Modification / Retro-Fitting In Existing Control And Monitoring System Of 33Kv / 11Kv Switch Gears And Equipments , Field Sensors , Transducers , Limit Switches And Wiring, Ups Having Capacity Of 02 Kva With 1 Hour Battery Backupfor Complete Control, Monitoring And Data Logging Ofsub-Stations Along Along With Adss , Fo Cable Link 15 Km With Accesories On Existiing Poles Between Thalout Substationand Nagwain Substation , With Substatation Survelliance System Including Ip Cameras And Nvr, I P Phones Etc. , Sub Station Automation System ( Scada ) With Necessary Hardware And Software And Any Modification / Retro-Fitting In Existing Control And Monitoring System Of 33Kv / 11Kv Switch Gears And Equipments , Field Sensors , Transducers , Limit Switches And Wiring, Ups Having Capacity Of 02 Kva With 1 Hour Battery Backupfor Complete Control, Monitoring And Data Logging Ofsub-Stations Along Along With Adss , Fo Cable Link 16 Km On Existing Poles With Accesories Between Kalkhar Substationand Rati Substation , With Subsatation Survelliance System Including Ip Cameras And Nvr I P Phones Etc.. , New 11Kv Ht Line , Support For 11 Kv Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work , 11.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-56 , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Pre-Fabricated Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Mounting Structure , Angle Iron For Road Crossings Etc Made Of Ms Channels ( 100X50x6mm ) , Ms Angle ( 65X65x6mm ) , Ms Flats ( 50X6 Mm ) Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. , Ms Nuts, Bolts With Washers As Per Technical Specification, Approved Drawings And Scope Of Work. , Stay Set ( Galvanised ) With 50X8 Mm Stay Clamp, Stay Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 2 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. , Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work. , 11 Kv Disc Insulator B&S Type Conformimg To Is-731 / 1971 All Latest Version Thereof For Suspension & Tension String Ball And Socket Type Having Pin Ball. The Minumum And Maximum Creepage Distance With Diameter Of Insulator- 255 Mm & Having Electromechanical Strength 90Kn. The Insulator Shall Have W Type Phosphors Bronze Security Clips For Ball Socket Porcelain Conforming Is: 2486-1971 ( 90Kn ) Complete In All Respect. Heavilypolluted Atmospheres Creepage Distance400 Mm , 11 Kv Pin Insulator Brownglazed Porcelain Insulator Alongwith Gi Pin Confirming To Is-731 / 1971 Or Latest Version Thereof With Minimum And Maximum Creepage Distance Distance & Duly Fitted With Lead / Zinc Thimble Suitable For Use With Gi Forged Pin Having Small Steel Head As Per Is:2486 ( Part-I & Ii ) Of 1993 & Latest Amendment If Any. Moderately Polluted Atmospheres Creepage Distance- 320Mm , Earthing Arrangement As Per Technical Specificatons, Approved Drawings And Scope Of Work. , Ht Earthing Set ( Rec Construction Standard J-1 ) , 8 Swg Gi Wire, Gi Nuts, Bolts & Washers For Earthing And Guarding , Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work , 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit , 11 Kv, 3-Ph, 400 A, 3 Pin Type, Horizontal / Vertical Mounting Type ( As Desired By Discom ) , Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 11 Kv, 3-Ph, Drop Out Fuse Units ( Set Of 3 Units ) Along With Support Insulators, Base Channel, Fuse Barrel Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , Danger Plate Size: 250X200x1.6 Mm Made Of Mild Steel Plates 1.6 ( Minimum ) Thick Vitreous Enameled White Letter Figure, Conventional Skill And X-Boxes And Signal Red Colour On Front Side For Use In Hpsebl. The Rear Side Of The Plate Shall Be Black Enameled And Conforming To Is Specifiction No. Is-1351 / 1982 Suitable For 11Kv , Eye Hook For Earth Wire , Galvanised Steel Barbed Wire Of 9.8 Kg / 100Metre , Aluminium Paint For All Poles And Steel Fitting , Red Oxide , New 22Kv Ht Line , Support For 22Kv Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work , 11.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-56 , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Pre-Fabricated Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Transformer Mounting Structure Etc Made Of Ms Channels ( 100X50x6mm ) , Ms Angle ( 65X65x6mm ) , Ms Flats ( 50X6mm ) Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. , Ms Nuts, Bolts With Washers As Per Technical Specification, Approved Drawings And Scope Of Work. , Stay Set ( Galvanised ) With 50X8 Mm Stay Clamp, Stay Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 2 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. , Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work. , 22 Kv Disc Insulator B&S Type ( 2 Nos. Disc ) Conformimg To Is-731 / 1971 All Latest Version Thereof For Suspension & Tension String Ball And Socket Type Having Pin Ball. The Minumum And Maximum Creepage Distance With Diameter Of Insulator- 225 Mm & Having Electromechanical Strength 90Kn. The Insulator Shall Have W Type Phosphors Bronze Security Clips For Ball Socket Porcelain Conforming Is: 2486-1971 ( 90Kn ) Complete In All Respect. Heavily Polluted Atmospheres Creepage Distance400 Mm , 22Kv Pin Insulator Brownglazed Porcelain Insulator Alongwith Gi Pin Confirming To Is-731 / 1971 Or Latest Version Thereof With Minimum And Maximum Creepage Distance Distance & Duly Fitted With Lead / Zinc Thimble Suitable For Use With Gi Forged Pin Having Small Steel Head As Per Is:2486 ( Part-I & Ii ) Of 1993 & Latest Amendment If Any. Moderately Polluted Atmospheres Creepage Distance- 560Mm , Earthing Arrangement As Per Technical Specificatons, Approved Drawings And Scope Of Work. , Ht Earthing Set ( Rec Construction Standard J-1 ) , 8 Swg Gi Wire, Gi Nuts, Bolts & Washers For Earthing And Guarding , Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work , 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit , 6 / 4.72 + 4 / 3.72 Mm ( 100 Mm² Al. Area ) - Dog , 22 Kv, 3-Ph, 400 A, 3 Pin Type, Horizontal / Vertical Mounting Type ( As Desired By Discom ) , Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 22 Kv, 3-Ph, Drop Out Fuse Units ( Set Of 3 Units ) Along With Support Insulators, Base Channel, Fuse Barrel Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , Danger Plate Size: 250X200x1.6 Mm Made Of Mild Steel Plates 1.6 ( Minimum ) Thick Vitreous Enameled White Letter Figure, Conventional Skill And X-Boxes And Signal Red Colour On Front Side For Use In Hpsebl. The Rear Side Of The Plate Shall Be Black Enameled And Conforming To Is Specifiction No. Is-1351 / 1982 Suitable For 22Kv , Eye Hook For Earth Wire , Galvanised Steel Barbed Wire Of 9.8 Kg / 100Metre , Aluminium Paint For All Poles And Steel Fitting , Red Oxide , Augmentation Of Lt Lines -1 Phase To 3-Phasewith 50 Sq. Mm Rabbit Conductor , Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work , 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32 , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Shackle Insulator ( 16 Kn ) , D-Iron ( U- Clamps ) , Earth Knob , Lt Stay Set , Stay Wire ( 7 / 3.15 Mm ) ( 6.0 Kg Per Stay Set ) , Full Clampsfor 1 No For Stay Set , Earthing Set Complete , Spool Tie , Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] , Aluminium Paint , Spiral Pvc Spacer , Red Oxide , Augmentation Of Lt Lines -2Phase To 3-Phasewith 50 Sq. Mm Rabbit Conductor , Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work , 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32 , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Shackle Insulator ( 16 Kn ) , D-Iron ( U- Clamps ) , Earth Knob , Lt Stay Set , Stay Wire ( 7 / 3.15 Mm ) ( 6.0 Kg Per Stay Set ) , Full Clamps 1 No For Stay Set , Earthing Set Complete , Spool Tie , Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] , Aluminium Paint , Spiral Pvc Spacer , Red Oxide , Reconductoring Of Lt Lines -1 Phase 2 Wire With 50 Sq. Mm Rabbit Conductor , Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work , 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32 , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Shackle Insulator ( 16 Kn ) , D-Iron ( U- Clamps ) , Earth Knob , Lt Stay Set , Stay Wire ( 7 / 3.15 Mm ) ( 6.0 Kg Per Stay Set ) , Full Clamps 1 No For Stay Set , Earthing Set Complete , Spool Tie , Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] , Aluminium Paint , Spiral Pvc Spacer , Red Oxide , Reconductoring Of Lt Lines -3 Phase 4 Wire With 50 Sq. Mm Rabbit Conductor , Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work , 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32 , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Shackle Insulator ( 16 Kn ) , D-Iron ( U- Clamps ) , Earth Knob , Lt Stay Set , Stay Wire ( 7 / 3.15 Mm ) ( 6.0 Kg Per Stay Set ) , Full Clamps 1 No For Stay Set , Earthing Set Complete , Spool Tie , Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] , Aluminium Paint , Spiral Pvc Spacer , Red Oxide , Cabling Of Lt Line With Ab Cable , Lt Ab Cable On Poles [ Size: ( 3X95 Sq, Mm ) { Additional 1% Sagging & Wastage ) , Lt Ab Cable On Poles [ Size: ( 3X95 Sq, Mm ) { Additional 1% Sagging & Wastage ) , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Pre-Fabricated Steel Items Like Cross Arm, Clamps, Knee-Bracings, Belts, Back Clamp Etc. Made Of Ms Channels ( 600X100x50x6mm ) , Ms Angle ( 750X50x50x6mm ) , Ms Flats ( 50X6 Mm ) Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work And Clapmps For Hangiing Assembles, Nut & Bolts , Galvanised Stay Set With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 2 Nos Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. , Full Clamp For Stay , Anchoring Assembly For Lt , Suspension Assembly For Lt , Facade Hooks For Lt , Distribution Boxes , T-Jointing Kit , Lt Earthing Set Complete ( Preferbly Coil Earthing ) , Red Oxide , Aluminium Paint , Ipc , Pvc 2 Core 10 Sqmm , Lt , Abcable3x185 Sq. Mm { Additional 1% Sagging & Wastage ) , Lt , Ab Cable3x185 + 16+70 Sq. Mm , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Pre-Fabricated Steel Items Like Cross Arm, Clamps, Knee-Bracings, Belts, Back Clamp Etc. Made Of Ms Channels ( 600X100x50x6mm ) , Ms Angle ( 750X50x50x6mm ) , Ms Flats ( 50X6 Mm ) Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work And Clapmps For Hangiing Assembles, Nut & Bolts , Stay Set ( Galvanised ) With 50X8 Mm Stay Clamp, Stay Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 2 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. , Full Clamp For Stay , X-Arm ( Horizontal ) - Ms Channel Iron: 100X50x6, Length [ 600 Mm ] , Half Clamp For Cross Arm , Anchoring Assembly For Lt , Suspension Assembly For Lt , Facade Hooks For Lt , T-Jointing Kit , Lt Earthing Set Complete ( Preferbly Coil Earthing ) , Red Oxide , Aluminium Paint , Distribution Boxes , Ipc , Pvc 3.5 Core 10 Sqmm , Ht , Abcable 11 / 22 Kv3x95 Sq. Mm { Additional 1% Sagging & Wastage ) , 11 Kv Ht Ab Cable On Poles [ Size: ( 3X95 Sq, Mm ) { Additional 1% Sagging & Wastage ) , 22 Kv Ht Ab Cable On Poles [ Size: ( 3X95 Sq, Mm ) { Additional 1% Sagging & Wastage ) , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Stay Set ( Galvanised ) With 50X8 Mm Stay Clamp, Stay Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 2 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. , Pre-Fabricated Steel Items Like Cross Arm, Clamps, Knee-Bracings, Belts, Back Clamp Etc. Made Of Ms Channels ( 600X100x50x6mm ) As Per Technical Specification, Approved Drawings And Scope Of Work. , Anchoring Assembly For Ht , Suspension Assembly For Ht , Facade Hooks For Ht , Heat Shrinkable Straight Through Jointing Kit Suitable For 11 Kv Cable Size ( 3X95 ) , Heat Shrinkable Straight Through Jointing Kit Suitable For 22 Kv Cable Size ( 3X95 ) , Cable Termination Kit Suitable For 11 Kv Cable Size ( 3X95 ) , Cable Termination Kit Suitable For 22 Kv Cable Size ( 3X95 ) , Ht Earthing Set Complete ( Preferbly Coil Earthing ) , Red Oxide , Aluminium Paint , Ht 22 / 11Kv Xlpecable3x120 Sq. Mm { Additional 1% Sagging & Wastage ) , Ht Xlpecable11 Kv On Poles [ Size: ( 3X120 Sq, Mm ) { Additional 1% Sagging & Wastage ) , Ht Xlpecable22 Kv On Poles [ Size: ( 3X120 Sq, Mm ) { Additional 1% Sagging & Wastage ) , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Stay Set ( Galvanised ) With 50X8 Mm Stay Clamp, Stay Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 2 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. , Pre-Fabricated Steel Items Like Cross Arm, Clamps, Knee-Bracings, Belts, Back Clamp Etc. Made Of Ms Channels ( 600X100x50x6mm ) , Ms Angle ( 750X50x50x6mm ) , Ms Flats ( 50X6 Mm ) Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work And Clapmps For Hangiing Assembles, Nut & Bolts , Heat Shrinkable Straight Through Jointing Kit 11 Kv , Heat Shrinkable Straight Through Jointing Kit 22 Kv , Cable Termination Kit 11 Kv , Cable Termination Kit 22 Kv , Ht Earthing Set Complete ( Preferbly Coil Earthing ) , Aluminium Paint , Steel Rope Of Suitable Size For Holding Of Xlpe Cable 3X120 Sqmmalongwithfixing Clampsand Allied Material. , Ht Ab Cable On Poles [ Size: ( 3X185 Sq, Mm ) { Additional 1% Sagging & Wastage ) , 11 Kv Abcablesize: ( 3+1X185 Mm² ) { Additional 1% Sagging & Wastage ) , 9.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-32. , Rcc Pipe ( Muff ) Isi Marked Suitable For Different Sizes Of Steel Poles. 2000 Mm In Length And 25 Mm Thick With 250 Mm Internal Dia Duly Fabricated By Using Un-Galvanized Ms Wires Of 12 Swg Rings And 6 Mm Ms Round In Vertical Direction Conforming To Isi 458-1988 Or Latest Version If Anyincluding Cement Concrete Filling 1:3:6 ( 1 Cement : 3 Sand : 6 Aggrigate 20 Mm Nominal Size ) . , Stay Set ( Galvanised ) With 50X8 Mm Stay Clamp, Stay Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 2 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. , Pre-Fabricated Steel Items Like Cross Arm, Clamps, Knee-Bracings, Belts, Back Clamp Etc. Made Of Ms Channels ( 600X100x50x6mm ) As Per Technical Specification, Approved Drawings And Scope Of Work. , Anchoring Assembly For Ht , Suspension Assembly For Ht , Facade Hooks For Ht , Heat Shrinkable Straight Through Jointing Kit , Cable Termination Kit , T-Jointing Kit , Ht Earthing Set Complete ( Preferbly Coil Earthing ) , Red Oxide , Aluminium Paint , Schedule-Ii ( Erection Part & Civil Works ) , Complete Survey Ofdivision Wise Scope Of Work I.E. Preliminary, Actual Surveying Profiling And Final Survey, Stacking Of Materials, Camp Shifting And Geo Tagging Of Newly Constructed Assetson Gis Portaletc. Complete Job , Ed Thalout , Ed Mandi , Ed J / Nagar , Eds / Ghat , Ed Gohar , Ed Dharampur , Ed Sunder Nagar , Ed Karsog , New Dtr 11 / 22 Kv ( Hvds, Feeder Bifurcation, Feeder Segregation And Extension Of New Ht, Dt, Lt As Per Technical Specification, Approved Drawings And Scope Of Work. , Erection Of 10 Kva, 16Kva, 25 Kva, 63 Kva, 100 Kvadtr, Complete Viz Digging Of Pit For Poles & Earthing ( 2 No. For Pole & 3 No. For Earthing ) , Drilling Of Holes In X Arms & Poles Prepration Of Plateformstructure Member Ci, Ai I.E. X-Arm & Knee Bracing Set, Erection Ofdouble Pole Structure, Concreting Of Rcc Muffs , Erection Of Plateform, Erection Of X-Arms, Erection Of G.O. Switch, Erection Ofdrop-Out Fuse Unit, Erection Of Lightning Arrestor, Erection Of Lt Box, Providingearthing Connection Including G.I.Wire To G.O Switch, Transformer, Lightning Arrestor, Etc , Erection Of 4 Nos. Stay Set , Erection Of Jumper, Pipe Earthing 3 No. Sets , Layingof Lt Cable, Barbed Wire & Painting Complete In All Respect , Erection Of 250Kva, 400Kva , 630Kvadtr, Complete Viz Digging Of Pit For Poles & Earthing ( 2 No. For Pole & 3 No. For Earthing ) , Drilling Of Holes In X Arms & Poles Prepration Of Plateformstructure Member Ci, Ai I.E. X-Arm & Knee Bracing Set, Erection Ofdouble Pole Structure, Concreting Of Rcc Muffs , Erection Of Plateform, Erection Of X-Arms, Erection Of G.O. Switch, Erection Ofdrop-Out Fuse Unit, Erection Of Lightning Arrestor, Erection Of Lt Box, Providingearthing Connection Including G.I.Wire To G.O Switch, Transformer, Lightning Arrestor, Etc , Erection Of 4 Nos. Stay Set , Erection Of Jumper, Pipe Earthing 3 No. Sets , Layingof Lt Cable, Barbed Wire & Painting Complete In All Respect , New Lt Line , 3 Ph 4 Wire Rabbit , Support For Lt Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work. , Erection Of 3 Phase Overhead Lt Line I / C Complete In All Respect I.E. Erction Of Pole , Stay Set Earthig , Rcc Muff, Jumpering, Earth Wire Etc ( Punching Of The Poles Is Stricitly Not Allowed ) , 1 Ph 2 Wire With Rabbit , Erection Of Single Phase Overhead Lt Line I / C Complete In All Respect I.E. Erction Of Pole , Stay Set Earthig , Rcc Muff, Jumpering, Earth Wire Etc ( Punching Of The Poles Is Stricitly Not Allowed ) , Augmentation & Renovation Of 11 / 0.4 Kv Distribution Transformer Substation , Augmentation Of Distribution Transformer Substation Using New Outdoor Type, Oil Immersed, Distribution Transformer Up To And Including 630 Kva As Per Is1180 ( Part-1 ) : 2014 And Its Amendments 1, 2, 3 And 4, Crgo / Amorphous Core, Energy Efficiency Level 1, Carrying Bureau Of Indian Standard Certificate Mark, In Following Preferred Ratings As Per Detailed Scope Of Work And Technical Specifications Under: , Dismantling Of Old 25Kva, 63, Kva Dtr A / W Lt Box, Meter & Cableand Erection Of New 63, 100, Kva Dtr A / W Lt Box, Meter & Cable And Transportation Of Dismantled Material From Site Of Work To Concerned Divisional Store , Dismantling Of Old 100, 250Kva, 400Kva Dtr A / W Lt Box, Meter & Cableand Erection Of New 250, 400Kva, 630Kva Dtr A / W Lt Box, Meter & Cable And Transportation Of Dismantled Material From Site Of Work To Concerned Divisional Store , Renovation Of Dtr Substation Earthing As Per Technical Specification, Approved Drawings And Scope Of Work: , Revamping Of Distribution Transformer Substation Earthing By Using 40 Mm Dia 3 Meter Long Gi Pipe Earthing, Using 50X6 Mm Gs Flat For Earth Mat And Riser And 25X3mm Gs Flat For Connecting Equipment, Using 200 Kg Bentonite Powder Of Substation In Normal Soil , Augmentation Of Dtr Substation By New Pre-Fabricated Galvanised Steel Items Like Dc Cross Arm ( 100X50x6 Mm ) , Back Clamps ( 65X8 Mm ) , Pole Clamp ( 65X8 Mm ) , Do Mounting Channel ( 75X40x6 Mm ) , Transformer Mounting Channel ( 100X50x6 Mm ) , Transformer Clamping Set ( 50X50x6 Mm ) , Transformer Belting Set ( 50X50x6 Mm ) As Per Technical Specification, Approved Drawings And Scope Of Work. , Augmentation Of Dtr Substation By New 9Kv, 11 Ka Distribution Class Lightening Arrester For Dt As Per Technical Specification, Approved Drawings And Scope Of Work. , Augmentation Of Dtr Substation By 18 Kv, 10 Ka Porcelain Station Surge Arrestor / Lightening Arrestorcomplete With Accessories For 22 Kv System , Augmentation Of Dtr Substation By New 11 Kv, 3-Ph, 400 A, 3 Pin Type, Vertical Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , Augmentation Of Dtr Substation By New22 Kv, 3-Ph, 400 A, 3 Pin Type, Horizontal / Vertical Mounting Type ( As Desired By Discom ) , Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 11Kv, 200 A, 3-Ph Drop Out Fuse Assembly Including Insulators And Mounting Arrangements, Jumpering From Bus Bar, Hardware, Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. , 22 Kv, 3-Ph, Drop Out Fuse Units ( Set Of 3 Units ) Along With Support Insulators, Base Channel, Fuse Barrel Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , Conversion Of Existing Lt Bare Conductor Line With Following Arrangements Using New Areal Bunched Xlpe Cable, Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral, Piercing Connectors Type-I & Type-Ii, 16 Mm Dia Ms Nuts & Bolts, Pole Clamps, Spring Loaded Bus Bar Suitable For Single Phase And Three Phase Systems Etc. As Required As Per Technical Specification, Approved Drawings And Scope Of Work: , Aerial Bunched Xlpe Cable 3 X 70+50+16 Sq.Mm , Laying, Installtion Of Suspension & Tension Assembly Etc., Sagging Of Lt Ab Cable Of Size: 3 X 70+50+16 Sqmm, Jointing And Termination Kits Etc. Complete , Erection Of Steel Tubular Pole 9Mtr Long ( Single Pole ) For Lt Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms & Ab Cable Fitting, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of Stay Set Lt ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Erection Of Lt Distibution Box Complete , Dismantling Of Old Conductor I / C Rolling Of Conductor , De-Stringing& Lifting Ofall Dismantled Material From Site Of Work To Concerned Divisional Store , Augmentation Of 33 / 11 Kvfully Outdoor Type Substation , Erection Of 33 / 11 Kv, 3 Ph, 50 Hz, Onan, Cu Wound, Outdoor Conventional Type Power Transformer Along With Transformer Oil, Buchholtz Relay, Breather, Oti & Wti, Marshalling Box, Conservator Tank, Oil Level Indicator, Valves, 2 Sets Of 50X8 Mm Gs Neutral Earthing Strips { ( With Braided Conductor On Bushing End ) , Isolating Link, Isolation With Insulators } , Vent Explosion Plug, Control Wiring Between Sensing Equipment And Marshalling Box, Cable Supporting Tray On The Body Of Transformer, Transformer Wheels, Lv / Hv Bushing Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Work. , 3.15 Mva Without Tap Changer , 6.30 Mva With Off Load Tap Changer , Erection Of 33Kv Gantries Structure / Super Structure Andequipment Structure For Mounting Isolators And Post Insulators, Bas Bar, Jumper Set , T-Sets Cross Arm Etc. , Erection Of 36Kv, 1250A, 25Ka For 3 Seconds, 3-Ph, Outdoor Type Vacuum Circuit Breaker Along With 36Kv, 1-Phase, 25Ka / 3 Seconds, 200-100 / 5-5 Amps Or 300-150 / 5-5 Amps 1 Set ( 3 Nos ) Outdoor Type Current Transformers Along With Junction Box ( 1 No Junction Box For 3 No Of 1-Phase Cts ) , Jumpers, Earthing, Supporting Structures, Bi- Metallic Clamps, Permanent Maintenance Platform, Marshalling Box Etc Required As Per Technical Specifications, Scope Of Works And Approved Drawings , Erection Of 33 Kv , 1250A , 25 Ka For 3Sec Auto Reclosure ( O / D Channel Mounted ) With Built In Feederprotections, Communicable For Remote Operation Through Scada System Iec 61850 , 104Compatible , Erection Of 33 Kv , 1250A , 25 Ka For 3Sec Auto Reclosure ( O / D Channel Mounted ) With Built In Power Transformer Protections, Communicablefor Remote Operation Through Scada System Iec 61850 , 104 Compatible , Erection Of 33Kv, Indoor, Control & Relay Panel Along With E / F & O / C Relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays And Other Components Etc As Per Approved Drawings, Specifications And Scope Of Works Controlling: , Erection Of 33 Kv Feeder Panel ( 33 Kv Incomer Bus ) [ Numeric Relay, Iec 61850 ] , Erection Of Power Transformerprotection Panel ( With Numericdifferential Relay / Ref Relay , Iec 61850 ) , Erection Of 36Kv, 1250A, 25Ka For 3 Seconds, 3-Ph Double Break Center Rotating Type ( Dbcr ) , Gang Operated Motorised Isolator Along With Support Insulators, Operating Mechanism, Base Channel Down Pipe And All Required Accessories Complete As Per Technical Specifications, Scope Of Works And Approved Drawings With Out Earth Switch. , Erection Of 36Kv, 1250A, 25Ka For 3 Seconds, 3-Ph Double Break Center Rotating Type ( Dbcr ) , Gang Operated Motorised Isolator Along With Support Insulators, Operating Mechanism, Base Channel Down Pipe And All Required Accessories Complete As Per Technical Specifications, Scope Of Works And Approved Drawings With Earth Switch , Erection Of 30 Kv, 10Ka, 1-Ph Station Class Lightening Arrester With Surge Counter, Mounting Platform, Jumpering From Bus Bar, Earthing Connection Using 50X6mm Gs Flat, Hardware Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. , Erection Of 9Kv, 10Ka, 1-Ph Station Class Lightening Arrester With Mounting Platform, Jumpering From Bus Bar, Earthing Connection Using 50X6mm Gs Flat, Hardware, Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. , Erection Of Indoor Type Control And Relay Panel As Per Technical Specifications, Approved Drawings And Scope Of Works: , Erection Of Indoor Type Control And Relay Panel For 11Kv, 3Phase, 1250 A Vcb ( Transformer Breaker ) Consisting Of Ct 800-400 / 1-1-1 A, Pt 11000 / 110 V-Meter, Volt-Meter, Relays & Accessories Complete As Per Specifications For Transformer Breaker Protection ( 12 Kv, 1250 A, 25Ka ) [ Numeric Relay, Iec 61850 ] , Erection Ofindoor Type Control And Relay Panel For 11 Kv 3 Phase, 1250 A Vcb ( Feeder Breakers ) Consisting Of Ct 400-200 / 1-1-1 A , 11000 / 110 V -Meter, Volt-Meter, Relays, Energy Meter ( Tvm ) & Accessories Complete As Per Specifications For Feeder Breaker Protection ( 12 Kv, 1250 A, 25Ka ) [ Numeric Relay, Iec 61850 ] , Erection Of 12 Kv, 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breakeralong With 12 Kv, 1-Phase, 800-400 / 1-1-1 , 3 Nos Indoor Type Current Transformer, Indoor Mounting Type Control Panel For Bus Coupler, Control Cabling Between Vcb And Indoor Control Panel And Required Accessories, Bi-Metallic Clamps, A-Meter, Volt-Meter, 3- Phase Electronic Energy Meter, Relay & Accessories Complete As Per Specifications For Bus Coupler Protection ( 12 Kv, 1250 A, 25Ka ) ( Numeric Relay , Iec 61850 ) , Erection Ofnumerical Directional Relay For 11 Kv Feeder Protectionwith Iec 61850 Complitant With Rj 45 Port , Erection Ofnumerical Differentialrelay For Transformer Protection On 11 Kv Incomer With Iec 61850 Compliant With Rj 45 Port , Erection Of 11 Kv , 800 A , 25 Ka For 3Sec Auto Reclosure ( O / D Channel Mounted ) With Built In Feederprotections, Communcablefor Remote Operation Through Scada System Iec 61850 , 104 Compatible , Erection Of30 V, 100 Ah Pb Acid Battery, Battery Stand Made Of Teak Wood Duly Painted With Anti Rusting Paint, Battery Insulators, Inter-Battery Wiring Using 30 Sqmm, 1.1 Kv, Copper Single Core Multi Strand Cable, Terminal Connectors, & All Other Accessories And Connectors And 30V, 40 Amp. ( Or As Per State Practice ) Float-Cum-Boost Battery Charger With Six Wave Rectification For 440 V, 3 Phase, 50 Hz Ac Input Supply As Per Technical Specifications, Approved Drawings And Scope Of Works , Erection Of 33 & 11 Kv Bus-Bars & Jumpers / Droppers / Terminations Including Hardware Fittings, Hardware, T-Claimp Etc As Per Technical Specifications, Approved Drawings And Scope Of Works , Erection Of 33 & 11 Kv Yard And Switch Gear Earthing & Grounding Conductor Etc. As Per Approved Electrical Layout For Each Sub-Station As Per Technical Specifications, Approved Drawings And Scope Of Works With , Erection Of Laying Dressing And Erection Of Control Cables, Power Cables Including Their Termination Materials Like Glands, Lugs, Ferruls Etc. As Per Technical Specifications, Approved Drawings And Scope Of The Work. , Erection Of 11 Kv Isolator Motorised ( 12 Kv, 630A, 25 Ka With Earthswitch Outdoor ) , Erection Of11.00 Mtr. Long Isi Marked Swaged Steel Tubular Pole / Joists As Per Is: 2713 / 1980 ( Part-Ii ) As Amended From Time To Time, Along With Cap Welded On Top & Cast Iron Base Plate Of Designation 410Sp-56. With Earthing And Jumper Isolator Etc Of 11 Kv Bay , Sub Station Automation System ( Scada ) With Necessary Hardware And Software And Any Modification / Retro-Fitting In Existing Control And Monitoring System Of 33Kv / 11Kv Switch Gears And Equipments , Field Sensors , Transducers , Limit Switches And Wiring, Ups Having Capacity Of 02 Kva With 1 Hour Battery Backupfor Complete Control, Monitoring And Data Logging Ofsub-Stations Along With Substattion Survelliance System Including Ip Cameras And Nvri P Phones Etc. At Thalout Substation , Tanihar And Sandhole Substation , Sub Station Automation System ( Scada ) With Necessary Hardware And Software And Any Modification / Retro-Fitting In Existing Control And Monitoring System Of 33Kv / 11Kv Switch Gears And Equipments , Field Sensors , Transducers , Limit Switches And Wiring, Ups Having Capacity Of 02 Kva With 1 Hour Battery Backupfor Complete Control, Monitoring And Data Logging Ofsub-Stations Along Along With Adss , Fo Cable Link 15 Km With Accesories On Existiing Poles Between Thalout Substationand Nagwain Substation , With Substatation Survelliance System Including Ip Cameras And Nvr, I P Phones Etc. , Sub Station Automation System ( Scada ) With Necessary Hardware And Software And Any Modification / Retro-Fitting In Existing Control And Monitoring System Of 33Kv / 11Kv Switch Gears And Equipments , Field Sensors , Transducers , Limit Switches And Wiring, Ups Having Capacity Of 02 Kva With 1 Hour Battery Backupfor Complete Control, Monitoring And Data Logging Ofsub-Stations Along Along With Adss , Fo Cable Link 16 Km On Existing Poles With Accesories Between Kalkhar Substationand Rati Substation , With Subsatation Survelliance System Including Ip Cameras And Nvr I P Phones Etc.. , Dismantling Works , Dismantling Of Old Power Transformers Along With Associated Material From Substation To Concerned Divisional Store , 3.15 Mva Without Tap Changer , 6.30 Mva With Off Load Tap Changer , Dismantling Of Old 33 Kv Cr&M Panels Along With Associated Material And Its Transportationfrom Substation To Concerned Divisional Store , Dismantling Of Old 33Kvcircuit Breakersalong With Associated Material And Its Transportationfrom Substation To Concerned Divisional Store , Dismantling Of Old 33Kvauto -Reclosers Along With Associated Material And Its Transportationfrom Substation To Concerned Divisional Store , Dismantling Of Old 11 Kv C&M Panels Along With Associated Material And Its Transportationfrom Substation To Concerned Divisional Store , Dismantling Of Old 11Kvauto -Reclosers Along With Associated Material And Its Transportationfrom Substation To Concerned Divisional Store , Dismantling Of Old 33Kvisolatorsalong With Associated Material And Its Transportationfrom Substation To Concerned Divisional Store , Dismantling Of Old 11Kvisolatorsalong With Associated Material And Its Transportationfrom Substation To Concerned Divisional Store , New 11Kv Ht Line , Support For 11 Kv Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work , Erection Charges Of 11 Kv Ht Line I / C Erction Of Single And Double Pole Strc, Stay Set , Earthing, Concreting Of Rcc Muff , Jumpering And Earth Wire Complete In All Respectsof Ht Line ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of 11 Kv, 3-Ph, 400 A, 3 Pin Type, Vertical Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 11Kv, 3-Ph Drop Out Fuse Assembly Including Insulators And Mounting Arrangements, Jumpering From Bus Bar, Hardware, Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. , New 22Kv Ht Line , Support For 22Kv Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work , Erection Charges Of 22 Kv Ht Line I / C Erction Of Single And Double Pole Strc, Stay Set , Earthing, Concreting Of Rcc Muff , Jumpering And Earth Wire Complete In All Respectsof Ht Line ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of 11 Kv, 3-Ph, 400 A, 3 Pin Type, Vertical Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete As Per Technical Specifications, Scope Of Works And Approved Drawings , 11Kv, 3-Ph Drop Out Fuse Assembly Including Insulators And Mounting Arrangements, Jumpering From Bus Bar, Hardware, Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. , Augmentation Of Lt Lines -1 Phase To 3-Phasewith 50 Sq. Mm Rabbit Conductor , Erection Of Steel Tubular Pole 9Mtr Long ( Single Pole ) For Lt Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms And Shackle Insulators, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Laying, Stringing , Sagging& Binding With Insulator Of Acsr Rabbit Conductor Of Size6 / 1 / 3.35 Mm ( 50Mm2 ) I / C Jumpering Etc. Complete , Erection Of Stay Set Lt ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Augmentationof Lt Lines -2Phase To 3-Phasewith 50 Sq. Mm Rabbit Conductor , Erection Of Steel Tubular Pole 9Mtr Long ( Single Pole ) For Lt Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms And Shackle Insulators, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Laying, Stringing , Sagging& Binding With Insulator Of Acsr Rabbit Conductor Of Size6 / 1 / 3.35 Mm ( 50Mm2 ) I / C Jumpering Etc. Complete , Erection Of Stay Set Lt ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Reconductoring Of Lt Lines -1 Phase 2 Wire With 50 Sq. Mm Rabbit Conductor , Erection Of Steel Tubular Pole 9Mtr Long ( Single Pole ) For Lt Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms And Shackle Insulators, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Laying, Stringing , Sagging& Binding With Insulator Of Acsr Rabbit Conductor Of Size6 / 1 / 3.35 Mm ( 50Mm2 ) I / C Jumpering Etc. Complete , Erection Of Stay Set Lt ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Dismantling Of Old Conductor I / C Rolling Of Conductor , De-Stringing& Lifting Ofall Dismantled Material From Site Of Work To Concerned Divisional Store , Reconductoring Of Lt Lines -3 Phase 4 Wire With 50 Sq. Mm Rabbit Conductor , Erection Of Steel Tubular Pole 9Mtr Long ( Single Pole ) For Lt Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms And Shackle Insulators, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Laying, Stringing , Sagging& Binding With Insulator Of Acsr Rabbit Conductor Of Size6 / 1 / 3.35 Mm ( 50Mm2 ) I / C Jumpering Etc. Complete , Laying, Stringing , Sagging& Binding With Insulator Of Acsr Rabbit Conductor Of Size6 / 1 / 4.72 Mm ( 100Mm2 ) I / C Jumpering Etc. Complete , Erection Of Stay Set Lt ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Dismantling Of Old Conductor I / C Rolling Of Conductor , De-Stringing& Lifting Ofall Dismantled Material From Site Of Work To Concerned Divisional Store , Cabling Of Lt Line With Ab Cable , Laying, Installtion Of Suspension & Tension Assembly Etc., Sagging Of Lt Ab Cable Of Size: 3 X 95 Sqmm, Jointing And Termination Kits Etc. Complete , Erection Of Steel Tubular Pole 9Mtr Long ( Single Pole ) For Lt Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms & Ab Cable Fitting, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of Stay Set Lt ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Erection Of Lt Distibution Box Complete , Erection Of Ipc , Erection Of Pvc 3.5 Core 16 Sqmm , Lt , Abcable3x185 Sq. Mm { Additional 1% Sagging & Wastage ) , Laying, Installtion Of Suspension & Tension Assembly Etc., Sagging Of Lt Ab Cable Of Size:3X185 Sq. Mm, Jointing And Termination Kits Etc. Complete , Erection Of Steel Tubular Pole 9Mtr Long ( Single Pole ) For Lt Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms & Ab Cable Fitting, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of Stay Set Lt ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Erection Of Lt Distibution Box Complete , Erection Of Ipc , Erection Of Pvc 3.5 Core 16 Sqmm , Ht , Abcable3x95 Sq. Mm { Additional 1% Sagging & Wastage ) , Laying, Installationof Suspension & Tension Assembly Etc., Sagging Of 11 Kv Ht , Abcable3x95 Sq. Mm, Jointing And Termination Kits Etc. Complete , Laying, Instalhtion Of Suspension & Tension Assembly Etc., Sagging Of 22 Kv Ht , Abcable3x95 Sq. Mm, Jointing And Termination Kits Etc. Complete , Erection Of Steel Tubular Pole 9Mtr Long For Ht Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms & Ab Cable Fitting, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of Stay Set Ht ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Ht Xlpecable3x120 Sq. Mm { Additional 1% Sagging & Wastage ) , Laying, Installationof Suspension & Tension Assembly Etc., Sagging Of Ht Xlpecable3x120 Sq. Mm, Jointing And Termination Kits Etc. Complete , Erection Of Steel Tubular Pole 9Mtr Long For Ht Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms & Xlpecable Fitting, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of Stay Set Ht ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Erection Of Steel Ropefor Holding Of Xlpe Cable 3X120 Sqmmalongwithfixing Clampsand Allied Material. , Ht Ab Cable On Poles [ Size: ( 3 C+1 ) X185 Sq, Mm ) ( 3X120, 3C+1 Messenger ) { Additional 1% Sagging & Wastage ) , Laying, Installation Of Suspension & Tension Assembly Etc., Sagging Of 11 Kv Ht , Abcable 3X185 ( 3C+1 Messenger ) / Sq. Mm, Jointing And Termination Kits Etc. Complete , Laying, Installation Of Suspension & Tension Assembly Etc., Sagging Of 11 Kv Ht , Abcable3x120 ( 3C+1 Messenger ) Sq. Mm, Jointing And Termination Kits Etc. Complete , Erection Of Steel Tubular Pole 9Mtr Long For Ht Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms & Ab Cable Fitting, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of Stay Set Ht ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Ht Ab / Xlpe Cable On Poles [ Size: ( 3X240 Sq, Mm ) { Additional 1% Sagging & Wastage ) , Laying, Installationof Suspension & Tension Assembly Etc., Sagging Of Ht Xlpecable3x240 Sq. Mm, Jointing And Termination Kits Etc. Complete , Erection Of Steel Tubular Pole 9Mtr Long For Ht Line Viz Digging Of Pit, Drilling Of Holes In X-Arms, Erection Of Pole, Erection Of X-Arms & Xlpecable Fitting, Filling Of Pit & Ramming , Painting Of Pole & Filling Of Concrete In Rcc Muffcomplete ( Punching Of The Poles Is Stricitly Not Allowed ) , Erection Of Stay Set Ht ( Digging Of Pit, Fixing Of Stay Rod, Filling Of Pit , Nozzeling & Tighting ) , Erection Of Earthing Set ( Digging Of Pit, Fixing Of Gi Wire To The Earth System & Filling Of Pit ) , Erection Of Steel Ropefor Holding Of Xlpe Cable 3X240 Sqmmalongwithfixing Clampsand Allied Material. , Civil Works , Construction Offoundation For 6.30Mva Sub-Station, 33 / 11Kv Power Transformer, Baffle Wall , R.S. Joist Foundation, Vcb Foundation, Ct / Pt, Oil Sump, Cable Trenches, Screening And Spreading Stone Shingle On Pcc And Foundation & Fencing For 250 To 630Kva Dtrs. Etc. , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge.:-Hard Rock ( Blasting Prohibited ) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:3:6 ( 1 Cement : 3 Coarse Sand ) : 6 Graded Stone Aggregate 40 Mm Nominal Size ) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 ( 1 Cement : 4 Coarse Sand ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: , Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. , Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) , Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm. , Supplying, Filling, Spreading & Leveling Gravels Of Approved Size In Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-Incharge. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:1½:3 ( 1 Cement: 1½ Coarse Sand ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) , Providing And Fixing G.I. Chain Link Fabric Fencing Of Required Width In Mesh Size 50X50 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer-In-Charge. Made Of G.I. Wire Of Dia 4 Mm , Providing And Fixing Isi Marked M.S. Pressed Butt Hinges Bright Finished With Necessary Screws Etc. Complete :100X58x1.90 Mm , Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete :250X16 Mm , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes For Weep Holes In Fire Protection Wall Complete In All Respect.75 Mm Diameter. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:- 1:5:10 ( 1 Cement : 5 Coarse Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size ) , Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge Nominal Concrete 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Sep-2022 new boq BOQ 20-09-2022
2 12-Sep-2022 corrigendum Other 20-09-2022
3 15-Sep-2022 Corrigendum of Bid Security appearing at ITB 18.1 (P-56) in Bid Data Sheet read as Other 20-09-2022
4 17-Sep-2022 extension of bid submission Date 03-10-2022
5 17-Sep-2022 submission of bid security Fee 03-10-2022

Key Value

Document Fees
INR 2950 /-
EMD
INR 38730211.0 /-
Tender Value
INR 193.65 Crore /-

BOQ Items

Name of Work: Tender for Development of Distribution Infrastructure for “Loss Reduction in District Mandi, Himachal Pradesh under RDSS (Revamped Reforms-Based and Results-Linked, Distribution Sector Scheme)
Sl. No. Item Description
1SCHEDULE-I (SUPPLY PART)
2New DTR 11/22 kV (HVDS, Feeder Bifurcation, Feeder Segregation and Extension of New HT, DT, LT as per technical specification, approved drawings and scope of work.
39.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
4RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
5Pre-fabricated galvanised steel (zinc coating 610gms/sqm), items like DC cross arm (100x50x6 mm), back clamps (50x6 mm), pole clamp (65x8 mm), DO fuse mounting channel (75x40x6 mm), transformer mounting channel (100x50x6 mm), transformer clamping set (50x50x6 mm), transformer belting set ( 50x50x6 mm) as per technical specification, approved drawings and scope of work.
6GS Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.
7Stay Set (Galvanised) with 50x8 mm stay clamp, Guy insulator ( 1Nos.), anchor plate (200x200x6mm), nut bolts, 2 Nos turn-buckles,1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
811 KV Disc insulator B&S type conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 255 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavilypolluted atmospheres Creepage distance-400 mm
922 KV Disc insulator B&S type ( 2 nos. disc)conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 225 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavily polluted atmospheres Creepage distance400 mm
10Distribution Transformer Substation using new outdoor type, oil immersed, distribution transformer up to and including 630 KVA as per IS1180 (Part-1): 2014 and its amendments 1, 2, 3 and 4,RGO/Amorphous core, Energy Efficiency Level 1, carrying Bureau of Indian Standard Certificate mark, in following preferred ratings as per detailed scope of work and technical specifications:
1122/0.230 kV Distribution Transformer 10 KVA 3PhaseDTR
1211/0.230 kV Distribution Transformer 16 KVA 3 Phase DTR
1311/0.4 KV Distribution Transformer 25 KVA 3 phase DTR
1422/0.4 KV Distribution Transformer 25 KVA 3 phase DTR
1511/0.4 KV Distribution Transformer 63 KVA 3 phaseDTR
1622/0.4 KV Distribution Transformer 63 KVA 3 phase DTR
1711/0.4 KV Distribution Transformer 100 KVA 3 phase DTR
1822/0.4 KV Distribution Transformer 100 KVA 3 phaseDTR
1911/0.4 KV Distribution Transformer 250 KVA 3 phaseDTR
20Outdoor mounting type Distribution box made of MS sheet of thickness not less than 18 SWG CRCA sheet/ SMC Distribution Box, dust and moisture vermin, weather proof with degree of protection with suitable bus bars, earthing cum neutral bus, earthing terminals, box illumination, front door operated with proper locking arrangement, lugs, mounting channel frame, internal wiring with FRLS cables, danger plate, numbering, back clamps, hardware as per scope of the work, technical specifications and approved drawings suitable for following transformer:
213 Ph 10KVA transformer 80 A TPN MCCB (incomer) and 2 Nos. 50 A SP MCCB (outgoing)
223 Ph 16 KVA transformer 80 A TPN MCCB (incomer) and 2 Nos. 50 A SP MCCB (outgoing)
233 Ph 25 KVA transformer 40 A TPN MCCB (incomer) and 6 Nos. 25 A SP MCCB (outgoing)
243 Ph 63 KVA Transformer having 200 A TPN isolator, 100 A HRC fuse (incomer) and 6 Nos. 60 A SP MCCB (outgoing)
253 Ph 100 KVA Transformer having 200 A TPN isolator, 160A HRC fuse (incomer) and 6 Nos. 90 A SP MCCB (outgoing)
26LT Distribution Panel Box suitable for 250KVA S/Stn of size 1100x800x275mm +/- 5% made of steel sheet of 1.63 mm thickness having doubledoor locking arrangement duly powder coated painted complete with 2 no. MCCB"s ( 1main + 1 spare) Rating 400Amp, 3 Poles having following specifications (1) Minimum frame size 400Amp (2) Type variable trip free, (3) Breaking capacity- Isu & LCS at 415, 50 Hz (KA: not less than 50 KA) (4) , Thermal release range: 320-440Amp (5) Mecanicallife (operation) 20000 No. (6) Electrical life (operation) 4000 No. (7) Rated insulation voltage (V) 690V (8) Tripping thermal releasing setting : Thermal-O/L variable setting (9) Tripping magnetic releasing setting : Magnetic- S/C fixed setting (12) in (10) (Operation) volatge 415V, AC (11) Caliberation temperature: 40 degree C(12) High voltage withstand voltage : 3KV for 1 minute (13) Confirming to IS : 1993/60947-2, 1989 (14) Make L&T/ Havells/ABB/ HPL/ Schneider (15) ICS : 100% ICU
279kV, 10 kA Porcelain Station Surge Arrestor/Lightening Arrestorcomplete with accessories for 11KV system
2818 kV, 10 kA Porcelain Station Surge Arrestor/Lightening Arrestorcomplete with accessories for 22 KV system
2911 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
3022 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
3111 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings
3222 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings
333 Nos pipe earthing using 40mm dia GI pipe 3000 mm long, making earth grid using 50x6mm GI Flat and riser as per scope of work of Distribution Transformer Substations, as per scope of work, approved drawings and technical specifications,
348 SWG GI wire for earthing as per technical specifications, approved drawings and scope of works.
35PVC 3.5 Core Aluminium Conductor, Stranded, unarmoured cable i/c thimbles of suitable size for connection of transformer LV bushing to Distribution Box and Distribution box to overhead line i/c proper clamping clamping of Cablesas per Scope of work, technical specification and approved drawings:
363.5 Cx16 sqmm aluminium conductor cable
373.5 CX35 sqmm aluminium conductor cable
383.5Cx70 sqmm aluminium conductor cable
393.5Cx120 sqmm aluminium conductor cable
403.5Cx185 sqmm aluminium conductor cable
41Danger Plate Size: 250x200x1.6 mm made of mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and signal red colour on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to IS specifiction no. IS-1351/1982 suitable for 11/22KV System
42Galvanised steel barbed wire of 9.8 kg /100metre
43Aluminium Paint for all poles and steel fitting
44Red Oxide
453 kVAR power factor correction capacitor along with MC O capacitor duty contractorfor new 25 kVA , 11/0.4 kV DTR
467 kVAR power factor correction capacitor along with MC O capacitor duty contractorfor new 63 kVA , 11/0.4 kV DTR
4710 kVAR power factor correction capacitor along with MC O capacitor duty contractorfor new 100 kVA , 11/0.4 kV DTR
48ACSR Rabbit Conductor for jumpering including PG Clamps, bi- metallic connectors, hardware etc as per technical specifications, approved drawings and scope of works.
49New LT Line 3 Ph 4 Wire Rabbit
50Support for LT overhead Line as per technical specification, approved drawings and scope of work.
519.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
52RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
53Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.
54Earthing as per approved drawings, technical specifications and scope of work
5540 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and Spike Earthing 20mm solid Rod i/c other accessories complete
568 SWG GI wire for earthing & GI nuts, bolts & washers
57ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
586/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
59Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
60Shackle Insulator (16 kN)
61D-Iron (U- Clamps)
62Earth Knob
63Kit kat I.C
64Full Clamps [ 2 No for A.I + 1 No for Stay Set]
65Spool Tie
66Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
67Aluminium Paint
68Spiral PVC Spacer
69Red Oxide
70New LT Line 1 Ph 2 Wire Rabbit
71Support for LT overhead Line as per technical specification, approved drawings and scope of work.
729.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
73RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
74Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.
75Earthing as per approved drawings, technical specifications and scope of work
7640 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and Spike Earthing 20mm solid Rod i/c other accessories complete
778 SWG GI wire for earthing & GI nuts, bolts & washers
78ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
796/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
80Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
81Shackle Insulator (16 kN)
82D-Iron (U- Clamps)
83Earth Knob
84Kit kat I.C
85Full Clamps [ 2 No for A.I + 1 No for Stay Set]
86Spool Tie
87Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
88Aluminium Paint
89Spiral PVC Spacer
90Red Oxide
91Augmentation & Renovation of 11/0.4 kV Distribution Transformer Substation
92Augmentation of Distribution Transformer Substation using new outdoor type, oil immersed, distribution transformer up to and including 630 KVA as per IS1180 (Part-1): 2014 and its amendments 1, 2, 3 and 4, CRGO/Amorphous core, Energy Efficiency Level 1, carrying Bureau of Indian Standard Certificate mark, in following preferred ratings as per detailed scope of work and technical specifications under:
93New 63 KVA (11/0.4 kV) DTR (Replacing 25KVA old DTR),
94New 63 KVA (22/0.4 kV)DTR (Replacing 25KVA old DTR),
95New 100 KVA (11/0.4 kV)DTR (Replacing 63 KVA old DTR),
96New 100 KVA (22/0.4 kV)DTR (Replacing 63 KVA old DTR),
97New 250 KVA (11/0.4 kV)DTR (Replacing 100 KVA old DTR),
98New 250 KVA (22/0.4 kV)DTR (Replacing 100 KVA old DTR),
99New 400 KVA (11/0.4 kV) DTR (Replacing 250 KVA old DTR),
100New 400 KVA (22/0.4 kV)DTR (Replacing 250 KVA old DTR),
101New 630 KVA (11/0.4 kV)DTR (Replacing 400 KVA old DTR),
102New 630 KVA (22/0.4 kV) DTR (Replacing 400 KVA old DTR),
103Augmentation of DTR Substation by using new 3.5 C PVCAluminium Conductor, Stranded, unarmoured cable for connection of transformer LV bushing to Distribution Box and Distribution box to overhead line as per Scope of work, technical specification and approved drawings. Replaced cables to be deposited in Employer"s store.
1043.5 Cx70 sqmm aluminium conductor cable
1053.5Cx120 sqmm aluminium conductor cable
1063.5Cx185 sqmm aluminium conductor cable
1073.5Cx300 sqmm aluminium conductor cable
1083.5Cx400 sqmm aluminium conductor cable
109Augmentation of DTR Substation by using new outdoor mounting type Distribution box made of MS sheet of thickness not less than 1.8 mm/ SMC distribution box, dust and moisture vermin, weather proof with degree of protection IP 33 as per IS 13947 with suitable bus bars, earthing bus, earthing terminals, box illumination, front door operated with proper locking arrangement, non magnetic 4 mm thick gland plate, double compression brass cable glands, lugs, mounting channel frame, internal wiring with FRLS cables, danger plate, numbering, back clamps, hardware as per scope of the work, technical specifications and approved drawings suitable for following transformer:
1103 Ph 63 KVA Transformer having 200 A TPN isolator, 100 A HRC fuse (incomer) and 6 Nos. 60 A SP MCCB (outgoing)
1113 Ph 100 KVA Transformer having 200 A TPN isolator, 160A HRC fuse (incomer) and 6 Nos. 90 A SP MCCB (outgoing)
112LT Distribution Panel Box suitable for 250KVA S/Stn of size 1100x800x275mm +/- 5% made of steel sheet of 1.63 mm thickness having doubledoor locking arrangement duly powder coated painted complete with 2 no. MCCB"s ( 1main + 1 spare) Rating 400Amp, 3 Poles having following specifications (1) Minimum frame size 400Amp (2) Type variable trip free, (3) Breaking capacity- Isu & LCS at 415, 50 Hz (KA: not less than 50 KA) (4) , Thermal release range: 320-440Amp (5) Mecanicallife (operation) 20000 No. (6) Electrical life (operation) 4000 No. (7) Rated insulation voltage (V) 690V (8) Tripping thermal releasing setting : Thermal-O/L variable setting (9) Tripping magnetic releasing setting : Magnetic- S/C fixed setting (12) in (10) (Operation) volatge 415V, AC (11) Caliberation temperature: 40 degree C(12) High voltage withstand voltage : 3KV for 1 minute (13) Confirming to IS : 1993/60947-2, 1989 (14) Make L&T/ Havells/ABB/ HPL/ Schneider (15) ICS : 100% ICU
113LT Distribution Panel Box suitable for 400KVA S/Stn. made of steel sheet of 1.63 mm thickness having doubledoor locking arrangement duly powder coated pained complete with ACB Rating 1000Amp, Duty Circle 0.3 Sec, Rating Symmetrical breaking capacity 50KA, Service Breaking Capacity 100% Icu, Rating Making Capacity 105KA Peak, Short circuit time for seconds (KA rms) 50KA, Thermal Current set value 1000 Amp, Time for which breaker can carry its rating breaking current <40 MS, Endurance (CO) Cycle Mechanical not less than 8000 operations, Electrical Not less than 5000 operations, Electrical life for Arcing contacts not less than 2500 operations,Insultion Voltage 1100 Volts, Impulse with stand voltage 8KV, Closing Mechanism Mannual independent mannual, Version required fixed and make L&T/Havells/C&S/HPL/Schneider
114LT Distribution Panel Box suitable for 630KVA S/Stn. made of steel sheet of 1.63 mm thickness having doubledoor locking arrangement duly powder coated pained complete with ACB Rating 1000Amp, Duty Circle 0.3 Sec, Rating Symmetrical breaking Capacity 50KA, Service Breaking Capacity 100% Icu, Rating Making Cap. 105KA Peak, Short circuit time for seconds (KA rms) 50KA, Thermal Current Set Value 1000 Amp, Time for which breaker can carry its rating breaking current <40 MS, Endurancec (CO) Ciycle Mechanical not less than 8000 operations,Electrical Not less than 5000 operations, Electrical life for Arcing Contacts not less than 2500 operations, Insulation Voltage 1100 Volts, Inpulse with stgand voltage 8KV, Closing Mechanism Mannual independent mannual, Version Required Fixed and Make L&T/Havells/C&S/HPL/Schiender.
115Renovation of DTR substation Earthing as per technical specification, approved drawings and scope of work:
116Revamping of Distribution Transformer substation earthing by using 40 mm dia 3 meter long GI pipe earthing, using 50x6 mm GS flat for earth mat and riser and 25x3mm GS flat for connecting equipment, using 200 kg bentonite powder of substation in normal soil
117Augmentation of DTR substation by new Pre-fabricated galvanised steel items like DC cross arm (100x50x6 mm), back clamps (65x8 mm), pole clamp (65x8 mm), DO mounting channel (75x40x6 mm), transformer mounting channel (100x50x6 mm), transformer clamping set (50x50x6 mm), transformer belting set ( 50x50x6 mm) as per technical specification, approved drawings and scope of work.
118Augmentation of DTR substation by new Galvanised Steel (GS) Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.
119Augmentation of DTR substation by new 9KV, 11 KA Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work.
120Augmentation of DTR substation by 18 kV, 10 kA Porcelain Station Surge Arrestor/Lightening Arrestorcomplete with accessories for 22 KV system
121Augmentation of DTR substation by new 11 kV, 3-ph, 200 A, 3 Pin type, Vertical Mounting type, Gang Operated,AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
122Augmentation of DTR substation by new22 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
123Aluminium Paint for substaion Structure and steel fitting
12411kV, 200 A, 3-ph Drop Out fuse assembly including insulators and mounting arrangements, jumpering from bus bar, hardware, etc as required as per technical specifications, approved drawings and scope of the works.
12522 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings
126Conversion of existing LT bare conductor line with following arrangements using new areal bunched XLPE cable,tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, 16 mm dia MS nuts & bolts, pole clamps, spring loaded bus bar suitable for single phase and three phase systems etc. as required as per technical specification, approved drawings and scope of work:
127AERIAL BUNCHEDCABLE 3 X 70+50+16 SQ.MM
128LT AB Cable Cable on poles [Size: 3 X 70+50+16 SQ.MM {additional 1% sagging & wastage)
1299.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
130RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
131Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.
132Half Clamp for Cross Arm
133Anchoring Assembly for LT
134Suspension Assembly for LT
135Facade Hooks for LT
136Distribution Boxes
137Earthing Set complete
138Red Oxide
139Aluminium paint
140Augmentation of 33/11 KVFully outdoor type substation
14133/11 kV, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type Power Transformer along with transformer oil, Buchholtz relay, breather, OTI & WTI, Marshalling Box, Conservator tank, oil level indicator, valves, 2 sets of 50x8 mm GS Neutral Earthing strips {(with braided conductor on bushing end), isolating link, isolation with insulators}, Vent explosion plug, control wiring between sensing equipment and marshalling box, cable supporting tray on the body of transformer, transformer wheels, LV/HV bushing etc as required as per technical specifications, approved drawings and scope of the work.
1423.15 MVA without tap changer
1436.30 MVA with off load tap changer
14433KV Superstructure andequipment structure
145Galvanised super structure comprisinggantries and columns
146Galvanised equipment structure for mounting 33KV Isolators and Post insulators
14736kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 36kV, 1-Phase, 25kA/3 seconds, 200-100/5-5 Amps or 300-150/5-5 Amps 1 Set( 3 nos) outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), Jumpers, earthing, supporting structures, bi- metallic clamps, permanent maintenance platform, marshalling box etc required as per technical specifications, scope of works and approved drawings
14833 kV , 1250A , 25 kA for 3sec Auto reclosure(o/d channel mounted) with built in feederprotections,communicable for remote operation through SCADA system IEC 61850 , 104compatible
14933 kV , 1250A , 25 kA for 3sec Auto reclosure (o/d channel mounted) with built in power transformer protections,communicablefor remote operation through SCADA system IEC 61850 , 104 compatible
15033kV, Indoor, Control & Relay panel along with E/F & O/C relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, specifications and scope of works controlling:
15133 kV feeder panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
152Power transformerprotection Panel (with NumericDifferential Relay / REF Relay , IEC 61850)
15336kV, 1250A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated motorised isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings with out earth switch.
15436kV, 1250A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated motorised isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings with earth switch
15530 kV, 10kA, 1-ph Station Class Lightening Arrester with Surge Counter,mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware etc as required as per technical specifications, approved drawings and scope of the works.
1569kV, 10kA, 1-ph Station Class Lightening Arrester with mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware, etc as required as per technical specifications, approved drawings and scope of the works.
157Indoor type control and relay panel as per technical specifications, approved drawings and scope of works:
158Indoor type control and relay panel for 11kV, 3phase, 1250 A VCB (Transformer Breaker)consisting of CT 800-400/1-1-1 A, PT 11000/110 V-meter, volt-meter, Relays & accessories complete as per specifications for transformer breaker protection (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
159Indoor type control and relay panel for 11 KV 3 phase, 1250 A VCB (Feeder Breakers) consisting of CT 400-200/1-1-1 A , 11000/110 V -meter, volt-meter, Relays, energy meter (TVM) & accessories complete as per specifications for feeder breaker protection(12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
16012 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor typeVacuum Circuit breakeralong with 12 kV, 1-Phase, 800-400/1-1-1 , 3 Nos indoor type Current Transformer, indoor mounting type control panel for bus coupler, control cabling between VCB and indoor control panel and required accessories, bi-metallic clamps, A-meter, volt-meter, 3- phase electronic energy meter, Relay & accessories complete as per specifications for bus coupler protection (12 kV, 1250 A, 25KA)(Numeric relay , IEC 61850)
161Numerical directional relay for 33 KV feeder Protectionwith IEC 61850 complitant with RJ 45 Port
162Numerical directional relay for 11 KV feeder Protectionwith IEC 61850 complitant with RJ 45 Port
163Numerical Differentialrelay for transformer protection on 11 KV incomer with IEC 61850 compliant with RJ 45 Port
16411 kV ,800 A , 25 kA for 3sec Auto reclosure(o/d channel mounted) with built in feederprotections,communcablefor remote operation through SCADA system IEC 61850 , 104 compatible
16530 V, 100 AH Pb Acid battery, battery stand made of teak wood duly painted with anti rusting paint, battery insulators, inter-battery wiring using 30 sqmm, 1.1 kv, copper single core multi strand cable, terminal connectors, & all other accessories and connectors and 30V, 40 Amp. (or as per State practice) Float-cum-Boost Battery Charger with six wave rectification for 440 V, 3 phase, 50 Hz AC Input Supply as per technical specifications, approved drawings and scope of works
166ACSR Conductor for Bus-Bars & Jumpers/Droppers/Terminations including hardware fittings, hardware, T-claimp etc as per technical specifications, approved drawings and scope of works
16730/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther
168Earthing & Grounding conductor as per Approved Electrical Layout for each sub-station as per technical specifications, approved drawings and scope of works with
16965 x 8 mm GI flat for ground mat
17050 x 6 mm Galvanized GI flat (risers)
17125mm dia GI rod 3 m long for earth mat
17250 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover, placed on GI frame, bantonide powder and other accessories complete as per technical specification. (for Power Transformer Neutral, Station Transformer Neutral and Lightening Arresters direct earthing) as per technical specifications, approved drawings and scope of works.
17333 KV Post insulators along with Strurcture, suitable hardware & accessories suitable for Panther/Dog conductors as per approved drawings & specifications.
174Control cables including their termination materials like glands, lugs etc. as per technical specifications, approved drawings and scope of the work.
1752 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable
17610 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable
17712 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable
1787Core 6.0 sqmm armoured, stranded copper conductor, PVC insulated screened and PVC sheathed cable
1794 Core 6.0 sqmm armoured, stranded copper conductor, PVC insulated screened and PVC sheathed cable
1803Core 400 sqmm XLPE , Al , armoured , Cable
181LT power cable PVC 1.1 KV ,4 core, Al ,16 mm2, un-armoured
18211kV , XLPE , outdoor type 3x 400sqmm termination kit
18311kV , XLPE , indoor type 3x400sqmm termination kit
18411 kV Isolator motorised (12 kV, 630A, 25 kA with Earthswitch outdoor)
18511.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56.
186RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size)
187Extension of 33kV and 11 KVcontrol bays
188RS Joists size 12800x250x125 mm
189MS Channel Iron 125x65x6, X-Arms @ 12.1 kg/m, 7 mtr long, 5.5mtr long , MSAI 50x50x6 mm for 33 and 11 KV yard
190Nuts and Bolts of Various Sizes (Galvanised / Coated)(with flat and spring washers)]
191Bus Bar
192i) 33 kVDisc Insulator Tension Stringcomplete
193ii) 33 kV Disc Suspension Tension String complete
194ACSR Conductor 200sqmm @ 10%
195PG Clamps
196Sub Station Automation System ( SCADA)with necessary hardware and software and any modification/retro-fitting in existing control and monitoring system of 33KV/11KV switch gears and equipments , field sensors , transducers , limit switches and wiring, UPS having capacity of 02 KVA with 1 hour Battery backupfor complete control, monitoring and data logging ofSub-Stations along with substattion survelliance system including IP cameras and NVRI P phones etc. at thalout substation , Tanihar and Sandhole Substation
197Sub Station Automation System ( SCADA)with necessary hardware and software and any modification/retro-fitting in existing control and monitoring system of 33KV/11KV switch gears and equipments , field sensors , transducers , limit switches and wiring, UPS having capacity of 02 KVA with 1 hour Battery backupfor complete control, monitoring and data logging ofSub-Stations along along with ADSS , FO cable link 15 kM with accesories on existiing poles between Thalout substationand Nagwain Substation , with substatation survelliance system including IP cameras and NVR, I P phones etc.
198Sub Station Automation System ( SCADA)with necessary hardware and software and any modification/retro-fitting in existing control and monitoring system of 33KV/11KV switch gears and equipments , field sensors , transducers , limit switches and wiring, UPS having capacity of 02 KVA with 1 hour Battery backupfor complete control, monitoring and data logging ofSub-Stations along along with ADSS , FO cable link 16 kM on existing poles with accesories between Kalkhar substationand Rati Substation , with subsatation survelliance system including IP cameras and NVR I P phones etc..
199New 11KV HT Line
200Support for 11 KV overhead line as per technical specification, approved drawings and scope of work
20111.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56
202RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
203Pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, mounting structure , angle iron for road crossings etc made of MS Channels (100x50x6mm), MS angle (65x65x6mm), MS flats (50x6 mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.
204MS Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.
205Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
206Insulator and hardware as per technical specification, approved drawings and scope of work.
20711 KV Disc insulator B&S type conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 255 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavilypolluted atmospheres Creepage distance400 mm
20811 kV Pin Insulator BrownGlazed Porcelain insulator alongwith GI Pin confirming to IS-731/1971 or latest version thereof with minimum and maximum creepage distance distance & duly fitted with lead/zinc thimble suitable for use with GI forged pin having small steel head as per IS:2486 (Part-I & II) of 1993 & latest amendment if any. Moderately polluted atmospheres Creepage distance- 320mm
209Earthing arrangement as per technical specificatons,approved drawings and scope of work.
210HT Earthing set (REC Construction Standard J-1)
2118 SWG GI wire, GI nuts, bolts & washers for earthing and guarding
212ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
2136/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
21411 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
21511 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings
216Danger Plate Size: 250x200x1.6 mm made of mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and signal red colour on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to IS specifiction no. IS-1351/1982 suitable for 11KV
217Eye Hook for earth wire
218Galvanised steel barbed wire of 9.8 kg /100metre
219Aluminium Paint for all poles and steel fitting
220Red Oxide
221New 22KV HT Line
222Support for 22KV overhead line as per technical specification, approved drawings and scope of work
22311.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56
224RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
225Pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, transformer mounting structure etc made of MS Channels (100x50x6mm), MS angle (65x65x6mm), MS flats (50x6mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.
226MS Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.
227Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
228Insulator and hardware as per technical specification, approved drawings and scope of work.
22922 KV Disc insulator B&S type ( 2 nos. disc)conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 225 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavily polluted atmospheres Creepage distance400 mm
23022kV Pin Insulator BrownGlazed Porcelain insulator alongwith GI Pin confirming to IS-731/1971 or latest version thereof with minimum and maximum creepage distance distance & duly fitted with lead/zinc thimble suitable for use with GI forged pin having small steel head as per IS:2486 (Part-I & II) of 1993 & latest amendment if any. Moderately polluted atmospheres Creepage Distance- 560mm
231Earthing arrangement as per technical specificatons,approved drawings and scope of work.
232HT Earthing set (REC Construction Standard J-1)
2338 SWG GI wire, GI nuts, bolts & washers for earthing and guarding
234ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
2356/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
2366/4.72 + 4/3.72 mm (100 mm² Al. Area) - Dog
23722 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
23822 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings
239Danger Plate Size: 250x200x1.6 mm made of mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and signal red colour on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to IS specifiction no. IS-1351/1982 suitable for 22KV
240Eye Hook for earth wire
241Galvanised steel barbed wire of 9.8 kg /100metre
242Aluminium Paint for all poles and steel fitting
243Red Oxide
244Augmentation of LT Lines -1 phase to 3-phasewith 50 Sq. mm Rabbit conductor
245ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
2466/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
2479.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32
248RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
249Shackle Insulator (16 kN)
250D-Iron (U- Clamps)
251Earth Knob
252LT Stay Set
253Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
254Full Clampsfor 1 No for Stay Set
255Earthing Set complete
256Spool Tie
257Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
258Aluminium Paint
259Spiral PVC Spacer
260Red Oxide
261Augmentation of LT Lines -2phase to 3-phasewith 50 Sq. mm Rabbit conductor
262ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
2636/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
2649.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32
265RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
266Shackle Insulator (16 kN)
267D-Iron (U- Clamps)
268Earth Knob
269LT Stay Set
270Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
271Full Clamps 1 No for Stay Set
272Earthing Set complete
273Spool Tie
274Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
275Aluminium Paint
276Spiral PVC Spacer
277Red Oxide
278Reconductoring of LT Lines -1 phase 2 wire with 50 Sq. mm Rabbit conductor
279ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
2806/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
2819.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32
282RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
283Shackle Insulator (16 kN)
284D-Iron (U- Clamps)
285Earth Knob
286LT Stay Set
287Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
288Full Clamps 1 No for Stay Set
289Earthing Set complete
290Spool Tie
291Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
292Aluminium Paint
293Spiral PVC Spacer
294Red Oxide
295Reconductoring of LT Lines -3 phase 4 wire with 50 Sq. mm Rabbit conductor
296ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
2976/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
2989.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32
299RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
300Shackle Insulator (16 kN)
301D-Iron (U- Clamps)
302Earth Knob
303LT Stay Set
304Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
305Full Clamps 1 No for Stay Set
306Earthing Set complete
307Spool Tie
308Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)]
309Aluminium Paint
310Spiral PVC Spacer
311Red Oxide
312Cabling of LT line with AB Cable
313LT AB Cable on poles [Size: (3x95 Sq, mm ) {additional 1% sagging & wastage)
314LT AB Cable on poles [Size: (3x95 Sq, mm ) {additional 1% sagging & wastage)
3159.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
316RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
317Pre-fabricated steel items like cross arm,clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm), MS angle (750x50x50x6mm),MS flats (50x6 mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work and clapmps for hangiing assembles, nut & bolts
318Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.
319Full Clamp for stay
320Anchoring Assembly for LT
321Suspension Assembly for LT
322Facade Hooks for LT
323Distribution Boxes
324T-Jointing kit
325LT Earthing set complete (preferbly coil earthing)
326Red Oxide
327Aluminium paint
328IPC
329PVC 2 Core 10 sqmm
330LT ,ABCable3x185 Sq. mm {additional 1% sagging & wastage)
331LT ,AB Cable3x185 + 16+70 Sq. mm
3329.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
333RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
334Pre-fabricated steel items like cross arm,clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm), MS angle (750x50x50x6mm),MS flats (50x6 mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work and clapmps for hangiing assembles, nut & bolts
335Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
336Full Clamp for stay
337X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
338Half Clamp for Cross Arm
339Anchoring Assembly for LT
340Suspension Assembly for LT
341Facade Hooks for LT
342T-Jointing kit
343LT Earthing set complete (preferbly coil earthing)
344Red Oxide
345Aluminium paint
346Distribution Boxes
347IPC
348PVC 3.5 Core 10 sqmm
349HT ,ABCable 11/ 22 KV3x95 Sq. mm {additional 1% sagging & wastage)
35011 kV HT AB Cable on poles [Size: (3x95 Sq, mm ) {additional 1% sagging & wastage)
35122 kV HT AB Cable on poles [Size: (3x95 Sq, mm ) {additional 1% sagging & wastage)
3529.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
353RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
354Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
355Pre-fabricated steel items like cross arm,clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm)as per technical specification, approved drawings and scope of work.
356Anchoring Assembly for HT
357Suspension Assembly for HT
358Facade Hooks for HT
359Heat Shrinkable Straight Through Jointing Kit suitable for 11 kV Cable Size (3x95)
360Heat Shrinkable Straight Through Jointing Kit suitable for 22 kV Cable Size (3x95)
361Cable Termination kit suitable for 11 kV Cable Size (3x95)
362Cable Termination kit suitable for 22 kV Cable Size (3x95)
363HT Earthing set complete (preferbly coil earthing)
364Red Oxide
365Aluminium paint
366HT 22/11KV XLPECable3x120 Sq. mm {additional 1% sagging & wastage)
367HT XLPECable11 kv on poles [Size: (3x120 Sq, mm ) {additional 1% sagging & wastage)
368HT XLPECable22 kv on poles [Size: (3x120 Sq, mm ) {additional 1% sagging & wastage)
3699.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
370RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
371Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
372Pre-fabricated steel items like cross arm,clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm), MS angle (750x50x50x6mm),MS flats (50x6 mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work and clapmps for hangiing assembles, nut & bolts
373Heat Shrinkable Straight Through Jointing Kit 11 kv
374Heat Shrinkable Straight Through Jointing Kit 22 kv
375Cable Termination kit 11 Kv
376Cable Termination kit 22 Kv
377HT Earthing set complete (preferbly coil earthing)
378Aluminium paint
379Steel Rope of suitable size for holding of XLPE Cable 3x120 sqmmalongwithfixing clampsand allied material.
380HT AB Cable on poles [Size: (3x185 Sq, mm ) {additional 1% sagging & wastage)
38111 kV ABCableSize: (3+1x185 mm²) {additional 1% sagging & wastage)
3829.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
383RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if anyincluding cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).
384Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
385Pre-fabricated steel items like cross arm,clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm)as per technical specification, approved drawings and scope of work.
386Anchoring Assembly for HT
387Suspension Assembly for HT
388Facade Hooks for HT
389Heat Shrinkable Straight Through Jointing Kit
390Cable Termination kit
391T-Jointing kit
392HT Earthing set complete (preferbly coil earthing)
393Red Oxide
394Aluminium paint
395SCHEDULE-II (Erection Part & Civil works)
396Complete Survey ofDivision wise Scope of Work i.e. preliminary, actual surveying profiling and final survey, stacking of materials, camp shifting and Geo tagging of newly constructed assetson GIS Portaletc. complete job
397ED Thalout
398ED Mandi
399ED J/Nagar
400EDS/Ghat
401ED Gohar
402ED Dharampur
403ED Sunder Nagar
404ED Karsog
405New DTR 11/22 kV (HVDS, Feeder Bifurcation, Feeder Segregation and Extension of New HT, DT, LT as per technical specification, approved drawings and scope of work.
406Erection of 10 KVA, 16KVA, 25 KVA, 63 KVA, 100 KVADTR, complete viz digging of pit for poles & earthing (2 No. for pole & 3 no. for earthing), Drilling of holes in X arms & poles Prepration of plateformstructure member CI, AI i.e. X-arm & Knee bracing set, Erection ofDouble Pole Structure, Concreting of RCC Muffs , Erection of plateform, Erection of x-arms, Erection of G.O. Switch, Erection ofDrop-Out Fuse Unit, Erection of Lightning arrestor, Erection of LT Box, ProvidingEarthing connection including G.I.Wire to G.O Switch, Transformer, Lightning arrestor,etc , Erection of 4 Nos. Stay set , Erection of Jumper, Pipe Earthing 3 No. sets , Layingof LT Cable, Barbed wire & painting complete in all respect
407Erection of 250KVA, 400KVA , 630KVADTR, complete viz digging of pit for poles & earthing (2 No. for pole & 3 no. for earthing), Drilling of holes in X arms & poles Prepration of plateformstructure member CI, AI i.e. X-arm & Knee bracing set, Erection ofDouble Pole Structure, Concreting of RCC Muffs , Erection of plateform, Erection of x-arms, Erection of G.O. Switch, Erection ofDrop-Out Fuse Unit, Erection of Lightning arrestor, Erection of LT Box, ProvidingEarthing connection including G.I.Wire to G.O Switch, Transformer, Lightning arrestor,etc , Erection of 4 Nos. Stay set , Erection of Jumper, Pipe Earthing 3 No. sets , Layingof LT Cable, Barbed wire & painting complete in all respect
408New LT Line
4093 Ph 4 Wire Rabbit
410Support for LT overhead Line as per technical specification, approved drawings and scope of work.
411Erection of 3 phase overhead LT line i/c complete in all respect i.e. erction of pole ,stay set earthig , rcc muff, jumpering, earth wire etc (Punching of the poles is stricitly not allowed)
4121 Ph 2 Wire with Rabbit
413Erection of Single phase overhead LT line i/c complete in all respect i.e. erction of pole ,stay set earthig , rcc muff, jumpering, earth wire etc (Punching of the poles is stricitly not allowed)
414Augmentation & Renovation of 11/0.4 kV Distribution Transformer Substation
415Augmentation of Distribution Transformer Substation using new outdoor type, oil immersed, distribution transformer up to and including 630 KVA as per IS1180 (Part-1): 2014 and its amendments 1, 2, 3 and 4, CRGO/Amorphous core, Energy Efficiency Level 1, carrying Bureau of Indian Standard Certificate mark, in following preferred ratings as per detailed scope of work and technical specifications under:
416Dismantling of old 25KVA, 63, KVA DTR a/w LT Box, meter & cableAnd Erection of new 63, 100, KVA DTR a/w LT Box, meter & cable and transportation of Dismantled material from site of work to concerned Divisional store
417Dismantling of old 100, 250KVA, 400KVA DTR a/w LT Box, meter & cableAnd Erection of new 250,400KVA, 630KVA DTR a/w LT Box, meter & cable and transportation of Dismantled material from site of work to concerned Divisional store
418Renovation of DTR substation Earthing as per technical specification, approved drawings and scope of work:
419Revamping of Distribution Transformer substation earthing by using 40 mm dia 3 meter long GI pipe earthing, using 50x6 mm GS flat for earth mat and riser and 25x3mm GS flat for connecting equipment, using 200 kg bentonite powder of substation in normal soil
420Augmentation of DTR substation by new Pre-fabricated galvanised steel items like DC cross arm (100x50x6 mm), back clamps (65x8 mm), pole clamp (65x8 mm), DO mounting channel (75x40x6 mm), transformer mounting channel (100x50x6 mm), transformer clamping set (50x50x6 mm), transformer belting set ( 50x50x6 mm) as per technical specification, approved drawings and scope of work.
421Augmentation of DTR substation by new 9KV, 11 KA Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work.
422Augmentation of DTR substation by 18 kV, 10 kA Porcelain Station Surge Arrestor/Lightening Arrestorcomplete with accessories for 22 KV system
423Augmentation of DTR substation by new 11 kV, 3-ph, 400 A, 3 Pin type, Vertical Mounting type, Gang Operated,AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
424Augmentation of DTR substation by new22 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
42511kV, 200 A, 3-ph Drop Out fuse assembly including insulators and mounting arrangements, jumpering from bus bar, hardware, etc as required as per technical specifications, approved drawings and scope of the works.
42622 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings
427Conversion of existing LT bare conductor line with following arrangements using new areal bunched XLPE cable,tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, 16 mm dia MS nuts & bolts, pole clamps, spring loaded bus bar suitable for single phase and three phase systems etc. as required as per technical specification, approved drawings and scope of work:
428AERIAL BUNCHED XLPE CABLE 3 X 70+50+16 SQ.MM
429Laying, Installtion of Suspension & Tension assembly etc., Sagging of LT AB Cable of size: 3 X 70+50+16 sqmm, jointing and termination kits etc. complete
430Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
431Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
432Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
433Erection of LT Distibution box complete
434Dismantling of old conductor i/c rolling of conductor , De-stringing& lifting ofall dismantled material from site of work to concerned divisional store
435Augmentation of 33/11 KVFully outdoor type substation
436Erection of 33/11 kV, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type Power Transformer along with transformer oil, Buchholtz relay, breather, OTI & WTI, Marshalling Box, Conservator tank, oil level indicator, valves, 2 sets of 50x8 mm GS Neutral Earthing strips {(with braided conductor on bushing end), isolating link, isolation with insulators}, Vent explosion plug, control wiring between sensing equipment and marshalling box, cable supporting tray on the body of transformer, transformer wheels, LV/HV bushing etc as required as per technical specifications, approved drawings and scope of the work.
4373.15 MVA without tap changer
4386.30 MVA with off load tap changer
439Erection of 33KV gantries structure/super structure andequipment structure for mounting Isolators and post insulators, bas bar, jumper set ,t-sets cross Arm etc.
440Erection of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 36kV, 1-Phase, 25kA/3 seconds, 200-100/5-5 Amps or 300-150/5-5 Amps 1 Set( 3 nos) outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), Jumpers, earthing, supporting structures, bi- metallic clamps, permanent maintenance platform, marshalling box etc required as per technical specifications, scope of works and approved drawings
441Erection of 33 kV , 1250A , 25 kA for 3sec Auto reclosure(o/d channel mounted) with built in feederprotections,communicable for remote operation through SCADA system IEC 61850 , 104compatible
442Erection of 33 kV , 1250A , 25 kA for 3sec Auto reclosure (o/d channel mounted) with built in power transformer protections,communicablefor remote operation through SCADA system IEC 61850 , 104 compatible
443Erection of 33kV, Indoor, Control & Relay panel along with E/F & O/C relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, specifications and scope of works controlling:
444Erection of 33 kV feeder panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
445Erection of Power transformerprotection Panel (with NumericDifferential Relay / REF Relay , IEC 61850)
446Erection of 36kV, 1250A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated motorised isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings with out earth switch.
447Erection of 36kV, 1250A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated motorised isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings with earth switch
448Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester with Surge Counter,mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware etc as required as per technical specifications, approved drawings and scope of the works.
449Erection of 9kV, 10kA, 1-ph Station Class Lightening Arrester with mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware, etc as required as per technical specifications, approved drawings and scope of the works.
450Erection of Indoor type control and relay panel as per technical specifications, approved drawings and scope of works:
451Erection of Indoor type control and relay panel for 11kV, 3phase, 1250 A VCB (Transformer Breaker)consisting of CT 800-400/1-1-1 A, PT 11000/110 V-meter, volt-meter, Relays & accessories complete as per specifications for transformer breaker protection (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
452Erection ofIndoor type control and relay panel for 11 KV 3 phase, 1250 A VCB (Feeder Breakers) consisting of CT 400-200/1-1-1 A , 11000/110 V -meter, volt-meter, Relays, energy meter (TVM) & accessories complete as per specifications for feeder breaker protection(12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
453Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor typeVacuum Circuit breakeralong with 12 kV, 1-Phase, 800-400/1-1-1 , 3 Nos indoor type Current Transformer, indoor mounting type control panel for bus coupler, control cabling between VCB and indoor control panel and required accessories, bi-metallic clamps, A-meter, volt-meter, 3- phase electronic energy meter, Relay & accessories complete as per specifications for bus coupler protection (12 kV, 1250 A, 25KA)(Numeric relay , IEC 61850)
454Erection ofNumerical directional relay for 11 KV feeder Protectionwith IEC 61850 complitant with RJ 45 Port
455Erection ofNumerical Differentialrelay for transformer protection on 11 KV incomer with IEC 61850 compliant with RJ 45 Port
456Erection of 11 kV ,800 A , 25 kA for 3sec Auto reclosure(o/d channel mounted) with built in feederprotections,communcablefor remote operation through SCADA system IEC 61850 , 104 compatible
457Erection of30 V, 100 AH Pb Acid battery, battery stand made of teak wood duly painted with anti rusting paint, battery insulators, inter-battery wiring using 30 sqmm, 1.1 kv, copper single core multi strand cable, terminal connectors, & all other accessories and connectors and 30V, 40 Amp. (or as per State practice) Float-cum-Boost Battery Charger with six wave rectification for 440 V, 3 phase, 50 Hz AC Input Supply as per technical specifications, approved drawings and scope of works
458Erection of 33 & 11 Kv Bus-Bars & Jumpers/Droppers/Terminations including hardware fittings, hardware, T-claimp etc as per technical specifications, approved drawings and scope of works
459Erection of 33 & 11 Kv yard and switch gear Earthing & Grounding conductor etc. as per Approved Electrical Layout for each sub-station as per technical specifications, approved drawings and scope of works with
460Erection of laying dressing and erection of Control cables, power cables including their termination materials like glands, lugs, ferruls etc. as per technical specifications, approved drawings and scope of the work.
461Erection of 11 kV Isolator motorised (12 kV, 630A, 25 kA with Earthswitch outdoor)
462Erection of11.00 Mtr. Long ISI marked swaged steel tubular pole/ joists as per IS: 2713/1980(Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56. with earthing and jumper isolator etc of 11 kV bay
463Sub Station Automation System ( SCADA)with necessary hardware and software and any modification/retro-fitting in existing control and monitoring system of 33KV/11KV switch gears and equipments , field sensors , transducers , limit switches and wiring, UPS having capacity of 02 KVA with 1 hour Battery backupfor complete control, monitoring and data logging ofSub-Stations along with substattion survelliance system including IP cameras and NVRI P phones etc. at thalout substation , Tanihar and Sandhole Substation
464Sub Station Automation System ( SCADA)with necessary hardware and software and any modification/retro-fitting in existing control and monitoring system of 33KV/11KV switch gears and equipments , field sensors , transducers , limit switches and wiring, UPS having capacity of 02 KVA with 1 hour Battery backupfor complete control, monitoring and data logging ofSub-Stations along along with ADSS , FO cable link 15 kM with accesories on existiing poles between Thalout substationand Nagwain Substation , with substatation survelliance system including IP cameras and NVR, I P phones etc.
465Sub Station Automation System ( SCADA)with necessary hardware and software and any modification/retro-fitting in existing control and monitoring system of 33KV/11KV switch gears and equipments , field sensors , transducers , limit switches and wiring, UPS having capacity of 02 KVA with 1 hour Battery backupfor complete control, monitoring and data logging ofSub-Stations along along with ADSS , FO cable link 16 kM on existing poles with accesories between Kalkhar substationand Rati Substation , with subsatation survelliance system including IP cameras and NVR I P phones etc..
466Dismantling Works
467Dismantling of old power transformers along with associated material from substation to concerned divisional store
4683.15 MVA without tap changer
4696.30 MVA with off load tap changer
470Dismantling of old 33 kV CR&M panels along with associated material and its transportationfrom substation to concerned divisional store
471Dismantling of old 33kVCircuit Breakersalong with associated material and its transportationfrom substation to concerned divisional store
472Dismantling of old 33kVAuto -Reclosers along with associated material and its transportationfrom substation to concerned divisional store
473Dismantling of old 11 kV C&M panels along with associated material and its transportationfrom substation to concerned divisional store
474Dismantling of old 11kVAuto -Reclosers along with associated material and its transportationfrom substation to concerned divisional store
475Dismantling of old 33kVisolatorsalong with associated material and its transportationfrom substation to concerned divisional store
476Dismantling of old 11kVisolatorsalong with associated material and its transportationfrom substation to concerned divisional store
477New 11KV HT Line
478Support for 11 KV overhead line as per technical specification, approved drawings and scope of work
479Erection charges of 11 KV Ht line i/c erction of single and double pole strc, stay set ,earthing, concreting of rcc muff ,jumpering and earth wire complete in all respectsof HT line (Punching of the poles is stricitly not allowed)
480Erection of 11 kV, 3-ph,400 A, 3 Pin type, Vertical Mounting type, Gang Operated,AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
48111kV, 3-ph Drop Out fuse assembly including insulators and mounting arrangements, jumpering from bus bar, hardware, etc as required as per technical specifications, approved drawings and scope of the works.
482New 22KV HT Line
483Support for 22KV overhead line as per technical specification, approved drawings and scope of work
484Erection charges of 22 KV Ht line i/c erction of single and double pole strc, stay set ,earthing, concreting of rcc muff ,jumpering and earth wire complete in all respectsof HT line (Punching of the poles is stricitly not allowed)
485Erection of 11 kV, 3-ph,400 A, 3 Pin type, Vertical Mounting type, Gang Operated,AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
48611kV, 3-ph Drop Out fuse assembly including insulators and mounting arrangements, jumpering from bus bar, hardware, etc as required as per technical specifications, approved drawings and scope of the works.
487Augmentation of LT Lines -1 phase to 3-phasewith 50 Sq. mm Rabbit conductor
488Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
489Laying, stringing , sagging& binding with Insulator of ACSR rabbit conductor of size6/1/3.35 mm (50mm2) i/c jumpering etc. Complete
490Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
491Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
492Augmentationof LT Lines -2phase to 3-phasewith 50 Sq. mm Rabbit conductor
493Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
494Laying, stringing , sagging& binding with Insulator of ACSR rabbit conductor of size6/1/3.35 mm (50mm2) i/c jumpering etc. Complete
495Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
496Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
497Reconductoring of LT Lines -1 phase 2 wire with 50 Sq. mm Rabbit conductor
498Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
499Laying, stringing , sagging& binding with Insulator of ACSR rabbit conductor of size6/1/3.35 mm (50mm2) i/c jumpering etc. Complete
500Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
501Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
502Dismantling of old conductor i/c rolling of conductor , De-stringing& lifting ofall dismantled material from site of work to concerned divisional store
503Reconductoring of LT Lines -3 phase 4 wire with 50 Sq. mm Rabbit conductor
504Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
505Laying, stringing , sagging& binding with Insulator of ACSR rabbit conductor of size6/1/3.35 mm (50mm2) i/c jumpering etc. Complete
506Laying, stringing , sagging& binding with Insulator of ACSR rabbit conductor of size6/1/4.72 mm (100mm2) i/c jumpering etc. Complete
507Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
508Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
509Dismantling of old conductor i/c rolling of conductor , De-stringing& lifting ofall dismantled material from site of work to concerned divisional store
510Cabling of LT line with AB Cable
511Laying, Installtion of Suspension & Tension assembly etc., Sagging of LT AB Cable of size: 3 X 95 sqmm, jointing and termination kits etc. complete
512Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
513Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
514Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
515Erection of LT Distibution box complete
516Erection of IPC
517Erection of PVC 3.5 Core 16 sqmm
518LT ,ABCable3x185 Sq. mm {additional 1% sagging & wastage)
519Laying, Installtion of Suspension & Tension assembly etc., Sagging of LT AB Cable of size:3x185 Sq. mm, jointing and termination kits etc. complete
520Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
521Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
522Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
523Erection of LT Distibution box complete
524Erection of IPC
525Erection of PVC 3.5 Core 16 sqmm
526HT ,ABCable3x95 Sq. mm {additional 1% sagging & wastage)
527Laying, Installationof Suspension & Tension assembly etc., Sagging of 11 kV HT ,ABCable3x95 Sq. mm, jointing and termination kits etc. complete
528Laying, InstalHTion of Suspension & Tension assembly etc., Sagging of 22 kV HT ,ABCable3x95 Sq. mm, jointing and termination kits etc. complete
529Erection of steel tubular pole 9mtr long for HT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
530Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
531Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
532HT XLPECable3x120 Sq. mm {additional 1% sagging & wastage)
533Laying, installationof Suspension & Tension assembly etc., Sagging of HT XLPECable3x120 Sq. mm, jointing and termination kits etc. complete
534Erection of steel tubular pole 9mtr long for HT Line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & XLPEcable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
535Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
536Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
537Erection of Steel Ropefor holding of XLPE Cable 3x120 sqmmalongwithfixing clampsand allied material.
538HT AB Cable on poles [Size: (3 C+1 )x185 Sq, mm ) (3x120, 3c+1 messenger) {additional 1% sagging & wastage)
539Laying, Installation of Suspension & Tension assembly etc., Sagging of 11 kV HT ,ABCable 3x185(3c+1 messenger)/Sq. mm, jointing and termination kits etc. complete
540Laying, Installation of Suspension & Tension assembly etc., Sagging of 11 kV HT ,ABCable3x120(3c+1 messenger) Sq. mm, jointing and termination kits etc. complete
541Erection of steel tubular pole 9mtr long for HT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
542Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
543Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
544HT AB /xlpe Cable on poles [Size: (3x240 Sq, mm ) {additional 1% sagging & wastage)
545Laying, installationof Suspension & Tension assembly etc., Sagging of HT XLPECable3x240 Sq. mm, jointing and termination kits etc. complete
546Erection of steel tubular pole 9mtr long for HT Line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & XLPEcable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muffcomplete (Punching of the poles is stricitly not allowed)
547Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)
548Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)
549Erection of Steel Ropefor holding of XLPE Cable 3x240 sqmmalongwithfixing clampsand allied material.
550CIVIL WORKS
551Construction ofFoundation for 6.30MVA Sub-Station,33/11KV Power transformer, Baffle wall ,R.S. Joist foundation,VCB foundation, CT/PT, oil sump, Cable trenches, Screening and spreading stone shingle on PCC and Foundation & fencing for 250 to 630KVA DTRs. etc.
552Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
553Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.:-Hard rock (blasting prohibited)
554Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
555Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
556Centering and shuttering including strutting, propping etc. and removal of form for:
557Foundations, footings, bases of columns, etc. for mass concrete.
558Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
559Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
560Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
561Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
562Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
563Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm.
564Supplying, filling, spreading & leveling gravels of approved size in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
565Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size)
566Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
567Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :100x58x1.90 mm
568Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm
569Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes for weep holes in fire protection wall complete in all respect.75 mm diameter.
570Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:- 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size)
571Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail