| Sl. No. | Item Description |
| 1 | Providing, boring, installing cast in-situ under-reamed pile 30cm dia with single under-reamed of 75cm dia and length 6 metre measured from bottom of pile cap to the tip of the pile using concrete mix M25 grade including boring, under-reaming under water using drilling mud & concreting by termic disposal of slush as directed by Engineer-in-charge and driving of welded reinforcement cages through freshly laid concrete. Jetting of piles as per IS-2911(Part-III) 1980, cost of the pile reinforcement to be embedded in the pile cap, length of pile to be embedded in the pile cap etc. complete it in all respect as per design and drawing and direction of Engineer- incharge. |
| 2 | Earthwork in excavation upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in all kinds of soil including moorum, hard stony earth, earth mixed with boulders, DI rocks etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. |
| 3 | Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. |
| 4 | Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 5 | Providing & laying cement concrete of prop. (1:3:6) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. |
| 6 | R.C.C. work ofM-25 for foundation having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 7 | R.C.C. work ofM-25 for plinth beam having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 8 | R.C.C. work ofM-25 for roof beam and column having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 9 | Ground Floor |
| 10 | First Floor |
| 11 | R.C.C. work ofM-25 for lintel having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 12 | Ground Floor |
| 13 | R.C.C. work ofM-25 for roof slab having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 14 | Ground Floor |
| 15 | First Floor |
| 16 | R.C.C. work ofM-25 for staircase having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 17 | Ground Floor |
| 18 | R.C.C. work ofM-25 for walls having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 19 | Ground Floor |
| 20 | First Floor |
| 21 | Providing & fixing TOR Fe-500 D grade reinforcement bars of approved makes as per DTCN for RCC work of required diameter with straightening, cutting, bending, binding welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing fan hooks, hoisting, lowering and laying including cost, conveyance and taxes of tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the drawing, design and direction ofEngineer-in-charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) |
| 22 | Ground Floor |
| 23 | First Floor |
| 24 | Brick work in foundation and plinth with flyash bricks in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be well burnt, free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. |
| 25 | Brick work in superstructure with flyash bricks in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be well burnt, free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. |
| 26 | Ground Floor |
| 27 | First Floor |
| 28 | Brick work in superstructure with flyash bricks in cement mortar (1:4) with best quality bricks having crushing strength not less than 75 Kg/cm2 imersing the bricks in water for not less than 6 hours before use (the bricks shall be well burnt, free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. |
| 29 | Ground Floor |
| 30 | Providing vitrified tile flooring using double charged vitrified tiles of premium grade having thick of 8mm to 10mm conforming to IS 13756 of 600mmx600mm coloured /printed series (homogeneous) of approved quality, colour in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 31 | Ground Floor |
| 32 | Supplying, fitting and fixing of double charged vitrified tiles in skirting of premium grade having thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm coloured /printed series (homogeneous) of approved quality, colour of approved quality and size in dadoes in all floors at all heights and riser of steps on 12mmm thick cement plaster (1:3) using screened and washed sharp sand for mortar with grouted Epoxy grout to match the shade of the tiles including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, curing-sundries and T&P, etc. required for the work complete as per specification and direction of Engineer-in-charge. |
| 33 | Ground Floor |
| 34 | Providing 40cmx40cm sizespecial plain/printed series antiskid ceramic floor tiles of premium grade of approved make having thickness 7mm to 8mm, conforming to IS 13755 for ceramic tileflooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient, grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the ceramic tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as directed by the Engineer-in-charge. |
| 35 | Ground Floor |
| 36 | Providing 30cmx45cm size special plain/printed seriesedge cut ceramic wall tiles of premium grade of approved make having thickness 6.5mm to 6.7mm conforming to IS 13753 of approved make & shade in Dadoes over 12mm thick cement plaster 1:3 (1 Cement: 3 Coarse sand) finished with modular pointing in white cement & pigment to match the shade of the tiles including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour curing sundries and T & P etc. required for the work etc. complete as per specification and direction of Engineer-in-charge. |
| 37 | Ground Floor |
| 38 | Providing 20mm thick and above 0.40 Sqm size granite stone flooring in staircase of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 39 | Ground Floor |
| 40 | Providing 20mm thick and above 0.40 Sqm size granite stone cladding of approved quality, colour and size in walls in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) (1 Cement: 3 Coarse sand) finished with modular pointing in white cement & pigment to match the shade of the granite including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour curing sundries and T & P etc. required for the work etc. complete as per specification and direction of Engineer-in-charge. |
| 41 | Ground Floor |
| 42 | Providing and fixing in position well dressed, naturally seasoned sal wood rebated frames of size 125mmx63mm to doors including two coats of hot bitumen applied to rear of frame in contact with masonry or concrete surface fixed with MS hold fast of 35x5mm embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete with all materials, labours, T & P including cost, conveyance, loading, sundries required for the work etc. complete in all respect as directed by the Engineer-in-charge |
| 43 | Supplying fitting and fixing in position 32mm thick flush door with teak wood beading and 1mm thick sunmica to both side pasted with adhessive including fixing of fixtures like Godrej make Mortice lock having model no 9168, 100mm aluminium hinges, handle, tower bolt, stopper including cost of all materials, labour, all taxes, transportation, loading & unloading etc. complete as per specification and direction of Engineer -in-charge. |
| 44 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitered at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturers as per specification and direction of Engineer-in-Charge and Providing and fixing factory made panel 30 mm thick plain PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moldedPVC \"C\" channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on both side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. but excluding GST complete as per direction of Engineer-in-charge. Manufacturer as per specification & drawing. |
| 45 | Providing fitting and fixing of Al. door with powder coated Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 6mm plain glass in top portion with 12mm thick prelaminated board in bottom portion fixed on door frame by means of tapered clip No 4660 and the frame to be completed by means of jointing angle No 1855 including all cost of labour, T&P,hire charges of drilling machine, labour charges etc complete. |
| 46 | Supplying, fitting, fixing up window (sliding type) made up powder coated aluminum Section 9778, as windows frame section No. 4095, 4096 and 9777, 3994 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-incharge. |
| 47 | Supplying fitting, fixing fully glazed aluminium framed openable window using 15 micron powder coated aluminium section 2082 as out section, 9139 as mullion section, 4124 as a shutter section frame with tapered clip of section 4125, aluminium angle rubber bedding, fricyion stay and handle etc. with 5mm glass. |
| 48 | Supplying, fitting and fixing of M.S window grills ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damagedwalls/ structures with cement concrete (1:2:4)with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge. |
| 49 | Providing edge moulding to 18 mm thick granite stone counters, Vanities, steps etc., including machine polishing to edge to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. |
| 50 | Providing and laying of PROFLEX roof with color coated galvalume sheet of 1.0 mm thickness including all anchors, fasteners, washers, epoxy paint, lacers, rubber paint and hangers including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-incharge. |
| 51 | Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to inside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. |
| 52 | Ground Floor |
| 53 | First Floor |
| 54 | Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. |
| 55 | Ground Floor |
| 56 | First Floor |
| 57 | Providing 6mm thick plaster in C.M. (1:4) over ceiling, chajja, loft, staircase, column, beams and walls after removing the false if necessary and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, taxes of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge. |
| 58 | Ground Floor |
| 59 | First Floor |
| 60 | Finishing wall surface with Acrylic wall putty to inside surface of approved make and finished smooth and even surface to receive painting to inside surface including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc complete as per direction of Engineer-in-charge. |
| 61 | Ground Floor |
| 62 | First Floor |
| 63 | Finishing wall surface with Acrylic wall putty to outside surface of approved make and finished smooth and even surface to receive painting to inside surface including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc complete as per direction of Engineer-in-charge. |
| 64 | Ground Floor |
| 65 | First Floor |
| 66 | Providing and painting two coats with plastic emulsion paint over a coat of primer of approved quality and approved shade in all floors at all height by making the surface to the interior plastered surface of wallsmooth including cost, coveyance, loading and unloading and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. |
| 67 | Ground Floor |
| 68 | First Floor |
| 69 | Painting to external surface of building with two coats of weather coat over a coat of primer of approved shade and quality of approved design, after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance and taxes of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. |
| 70 | Ground Floor |
| 71 | First Floor |
| 72 | Providing and painting two coats with synthetic enamel paint over a coat of red oxide primer of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height including sand papering and making the surface smooth with cost, coveyance, loading and unloading, and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. |
| 73 | Ground Floor |
| 74 | Providing 25mm thick grading concrete in C.C. (1:2:2) laid in proper slope over terrace roof slab by using two part of sand, one part of cement and two parts of6mm size black hard crusher broken granite chips with addition of water proofing compound of approved quality to be mixed with specified ratio including watering, curing, cost, conveyance, royalties, taxes of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. |
| 75 | Ground Floor |
| 76 | Providing Cleaning the roof top/sunken surface by using manual means with wire brush & chisel to make the surface free from foreign particles & deposit mortar , Sealing of outlet pipe junction with Sikagard 694Fi Epoxy puttyand applying two coats of SikaTopseal109hi. With fiber glassElastic, liquid applied crack bridging, coloured, 2-pack acrylic-cementitious waterproofing coating system Complete with all respect as per direction of the engineer in charge & manufacturer instructions.Base coat: SikaTop® Seal-109 hi.,Consumption base coat: 0.7 kg/m2..,Top coat: SikaTop® Seal-109 hi.Consumption top coat: 1.5 kg/m2.System requirements: Conforms to IS 2645,IS 101ElElongation at break: 40 %; slant shear bond strength: approx. 4 N/mm2as per FIP 5.15; water permeability passes as per IS 2645; weather resistance as per IS 101.Cl |
| 77 | Providing and injecting chemical emulsion for pre - constructional antitermite treatment as per IS specification and creating a chemical barrier in bottom and sides of foundation trenches, top-surface of plinth filing junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and cables etc. complete using approved quality of chemical emulsion of requisite quantity prescribed by the manufacturer as directed by the Engineer-in-charge including cost of all materials and labour taxes etc. complete. (indemnity bond for warranty for 5 years to be furnished) |
| 78 | Providing neat cement punning in all floors with Portlandslag cement (PSC) finished smooth to floors after including watering and curing complete with cost, conveyance, loading and unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P, scaffolding required for the work etc. complete in all respect as per the direction of Engineer-in-Charge. |
| 79 | Providing and laying/sprinkling non metallic heavy duty floor hardener @ 3.0 kg per sqm over the wet concreteincluding finishing the same as per the direction of the manufacturers specifications. Contractor has to submit the material for approval before each panel pour as per the prescribed consumption factor. Approved Make ; Sika, STP, Fosroc |
| 80 | Providing Vacuum Dewatering Pump to remove the air voids, water for quick setting the concrete, bull floating and striking of, power toweling, adding floor hardener with policing by using disk blade in Trimix flooring including cost of all materials labour T&P etc complete as per direction of Engineer in charge. |
| 81 | Supplying all labour, T&P for the Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge. |
| 82 | Supplying all materials, labours, T&P for fitting and fixing white glazed vitreous china floor mounted European water closet of Hindware make having cat no 20079 or equivalent type of approved make including supply of matching P/S trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete including cost of WC pan, PVC seat cover with CP brass hinges and rubber buffers etc all complete including cost, taxes and conveyance as per specification including polishing etc all complete as per PH specification and direction of Engineer-in-charge. |
| 83 | Supply all materials, labour,T&P for fitting and fixing of PVC cistern of hindware make sleek fresh ISI or equivalent type of approved make complete with all parts and internal fittings of approved make with ISI mark and supplying of necessary brackets, screws etc 32mm dia flush bend, 15mm dia 450mm long PVC water connecting pipe of jaquar make having cat no ALD 803AB with CP or brass union nuts at each end as per PH specification all complete as per direction of Engineer-in-charge. |
| 84 | Supplying all material, labour T&P and fixtures for providing and fixing of white glazed vitreous chinaware counter top wash hand basin of size 79cm dia of Hindware make having cat no 10052 or equivalent type of approved make with bottle trap of Jaquar cat no ALD 769L250 with CP waste coupling nut of Jaquar make having cat no ALD 709 and 15mm x 450mm PVC connection pipe of Jaquar make having cat no ALD 803AB with MS bracket with wooden plugs CP screws including cost of cement, sand, labour, T&P etc. complete including testing cost, conveyance, royalty and taxes of all materials etc. complete as per PH specification and direction of Engineer-in-charge. |
| 85 | Supplying and fixing urinal of Hindware make having cat no 60020 or equivalent type of approved make with division plate of hindware make having cat no 61001 or equivalent including all fittings like 450mm long connection pipe of Jaquar make having cat no ALD 803B, 32mm dia bottle trap of jaquar ALD 769L250 etc of approved make etc complete as per PH specification and direction of the Engineer-in-charge. |
| 86 | Supplying all materials, labor T&P for fitting and fixing in all floors\" fixed type glass mirror of size 600mm x 450mm best INDIAN make of 5.5 mm thickness with supply of 13mm thick asbestos backing and wooden plugs C. P. Brass screw including cost, conveyance, royalty, taxes of all materials complete as per P.H. specification and direction of Engineering-in-charge. |
| 87 | Supplying all materials, labour, T&P and fixing standard sizedCP towel rail - 24\"of Jaquar Cat. No.-ACN-1111SM or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 88 | Supplying all materials, labour, T&P and fixing standard sizedCP towel ring of Jaquar Cat. No.-ACN-1121N or equivalent etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 89 | Supplying all materials, labour, T&P and fixing standard sizedBib cock short body of Jaquar Cat. No.-FLR-5047N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 90 | Supplying all materials, labour, T&P and fixing standard sized15mm dia concealed Stop cock of Jaquar Cat. No.-FLR-5083NK with ALD-083 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 91 | Supplying all materials, labour, T&P and fixing standard sized15mm dia Angular Stop cock of Jaquar Cat. No.-FLR-5053N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 92 | Supplying all materials, labour, T&P and fixing standard sizedpillar cock of Jaquar Cat. No.-FLR-5011N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 93 | Supplying all materials, labour, T&P and fixing standard sizedCP Soap case of Jaquar Cat. No.-ACN-1131N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 94 | Supplying all materials, labour, T&P and fixing two way Bib cock of Jaquar Cat. No.-FLR-5041N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 95 | Supplying all materials, labour, T&P and fixing health faucet of Jaquar Cat. No.-ALD-563 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 96 | Providing and fixing C.P. Glass shelf 600mm long of Jaquar Cat. No.-ACN-1171N or equivalent type of approved make fixed to wall including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 97 | Supplying all materials, labour, T&P and fixing toilet paper holder of Jaquar Cat. No.-ACN-1153S or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 98 | Supplying all materials, labour, T&P and fixing of 150x150mm CP overhead shower of Jaquar Cat. No.-OHS-1789 with arm SHA-483 or equivalent etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 99 | Supplying all materials, labour, T&P and fixing standard sizedCP robe hook of Jaquar Cat. No.-ACN 1191N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 100 | Providing and fixingcircular type stainless steeljalli (grating) with hole for floor /nahani trap etc complete as per PH specification and direction of the engineer in charge |
| 101 | Supplying all materials, labours, T&P and fitting and fixing of the following size of CPVC pipeconfirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge. |
| 102 | 15 mm dia |
| 103 | 20 mm dia |
| 104 | 25 mm dia |
| 105 | 32 mm dia |
| 106 | 40mm dia |
| 107 | 50mm dia |
| 108 | Supplying all materials, labour, T&P, fitting and fixing UPVC SWR pipes & fittings of approved make confirming to IS-13592, both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:2:4) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge. |
| 109 | 75mm dia |
| 110 | 110mm dia |
| 111 | Supplying all materials, labour, T&P, fitting and fixing of UPVC SWR fittings of approved make with requisite testing etc complete as per PH specification and direction of Engineer-in-charge. |
| 112 | 110mm dia Single Junction with door |
| 113 | 110mm dia Double Junction with door |
| 114 | 110mm dia Cowl |
| 115 | 110mm dia Plain Bend |
| 116 | 110mm dia SWR Door Bend |
| 117 | 125mm x 110mm Gulley Trap |
| 118 | 110mm dia Tee with door |
| 119 | 110mm dia Single Junction without door |
| 120 | 110mm dia Socket Plug |
| 121 | 110mm dia Pipe clip |
| 122 | 110mm diaCoupler |
| 123 | 75mm dia Plain Bend |
| 124 | Supplying all materials, labour, T&P, fitting & fixing of different size UPVC Ball Valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and direction of the Engineer-in-charge. |
| 125 | 25mm Dia |
| 126 | 32mm Dia |
| 127 | 40mm Dia |
| 128 | 50mm Dia |
| 129 | Supplying all materials,labours,T&P for cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. |
| 130 | Supplying all materials,labours,T&P for cutting holes through existing RCC floors & roofs including making good the damages for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. |
| 131 | Supplying all materials,labours,T&P for cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking SWR/HCI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. |
| 132 | Supplying all materials,labours,T&P for cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per direction of Engineer-in-charge. |
| 133 | Supplying all materials, labour, T&P and fittings and fixing of 3000 LTR Poly Propelene white double layer water storage Tank of approved make confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc including hoisting upto terrace level and placing the tank to the required position etc all complete as per PH specification and direction of Engineer-in-charge. (To provided with brick masonary guard walls which will be paid separately) |
| 134 | Supplying all materials, labour, T&P, fitting and fixing UPVC SWR pipes & fittings of approved make confirming to IS-13592, both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:2:4) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge. |
| 135 | 150mm dia |
| 136 | 200mm dia |
| 137 | Supplying all materials, labour, T&P and necessary materials towards laying of RCC NP2 Hume pipe push tight joint type (including cost of RCC Hume pipe) inside the pipeline trench of required size with plastic rope without damage to the pipe with all convenience the materials to site and including all taxes all complete as per direction of Engineer-in-charge. |
| 138 | 150mm Dia |
| 139 | 200mm Dia |
| 140 | 250mm Dia |
| 141 | 300mm Dia |
| 142 | Providing & fixing P V C sleeve in tanks |
| 143 | 75 mm dia nominal bore |
| 144 | 100mm dia nominal bore |
| 145 | 150mm dia nominal bore |
| 146 | Supplyng all materials, labour, T&P for construction of brick masonary Gulley trap chamber of size 250mm x 250 mm with CI gulley trap, by flyash brick masonry in CM (1:4), CP (1:3) with 150mm x 150mm CI grating including labour and materials for fitting and fixing 100mm dia square mouth CI gully trap with supply of all jointing materials and encasing the gully trap with a block of CC (1:3:6) with 25mm size hard stone metal all complete with providing and fixing of 250mm x 250mm precast RCC cover slab including cost, conveyance, taxes of all materials to site complete as per the PH specification and direction of Engineer-in-charge. |
| 147 | Supplying all materials,labours,T&P for constructing inspection chamber of 900mmx800mmx450mm with cement concrete (1:3:6) on bed with hard granite metal size 40mm and flyash brickwork in cement mortar (1:4) in foundation and plinth, 100mm thick RCC M25 cover slab with supplying fitting and fixing of medium duty SFRC manhole cover, moulding and shaping the channel and benching with cement concrete (1:2:4) using 12mm size hg chips,12mm thick cement plaster in cement mortar (1:3) with punning to inside, cement plaster in CM (1:3) to outside the chamber including centring, shuttering, providing required quantity of MS rods and binding wires for reinforcement, bending, binding, tying the grills and placing in the proper position and drawing and design and PH specification including cost, conveyance, royalty, taxes etc for all materials as per the drawing, design and direction of Engineer-in-charge. |
| 148 | Construction of brick masonary inspection chamber of size 1.20 x 0.90 mtr including cement concrete (1:3:6) in bed by using 40mm size granite metal, brickwork in CM (1:4) in foundation & plinth, cement plastering (1:3) over flyash brick, plastering in CM (1:3) with neat cement punning, CC (1:2:4) over bed for benching and channeling, RCC M25 for roof slab of 150mm thick and supply fitting and fixing SFRC medium duty type cover including cost of centring and shuttering cost of MS rod for RCC work, supplying fitting and fixing of the polypropelen step iron of required interval etc all complete with all cost, conveyance, royalties taxes etc all complete as per direction of Engineer-in-charge. |
| 149 | Extra for every additional depth of 0.10mtr or part there of manhole size 1200x900mm from 1100mm to 1650mm depth (data for 0.10 mtr per each) |
| 150 | Extra lift or 1.5m or part there of over the initial lift of 1.5m in all kinds of embankments and road works and ordinary earth work in general. |
| 151 | Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of bedding for pvc pipes of the following internal diameter including curing complete as per specification (A1-Type Bedding) |
| 152 | 150mm Dia |
| 153 | 200mm Dia |
| 154 | 250mm Dia |
| 155 | 300mm Dia |
| 156 | Providing and laying plain cement concrete of (1:2:4) for mending of sewer line trench using 12 mm. Size black hard crusher broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties of all materials and cost of all labours, sundries, T & P required for the work etc complete as per the instruction of the Engineer-in-Charge. |
| 157 | Providing 12mm. thick cement plaster with cement mortar of mix (1:4) in all floors with Portlandslag cement (PSC) and with screened and washed sharp sand for mortar with neat cement punning finished smooth to brick/RCC walls after racking out the joints including watering and curing complete with cost, conveyance, loading and unloading, royalties of all materials, cost of all labour, sundries, T&P, scaffolding required for the work etc. complete in all respect as per the direction of Engineer-in-Charge. |
| 158 | Providing fittingand fixing 20mm OMS step iron .as per the Engineer-in-charge |
| 159 | Supplying and fixing 900mm dia SFRC cover without frame for manhole including cost of all materials, T&P, labour etc complete as per direction of Engineer-in-charge. |
| 160 | Providing fittingand fixing 100mm (4\") dia HCI vent pipe of 1.0mt length with cowl.as per the Engineer-in-charge |
| 161 | Supplying all materials,labours,T&P and constructing 1.22m dia and 2.1m depth soakway pit with precast RCC rings joined loose,gravel backing in the rear of well steining,precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty etc all complete as per approved specification and direction of Engineer-in-charge. |
| 162 | Conducting reconnaissance survey, integrated Hydrological & Geophysical (Electrical Ressistivity method) survey and selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling production wells in selected area. |
| 163 | Labour for drilling a perfectly verticalbore hole for a specified dia for a specifieddepth below G.L through consolidated and un-consolidated rocks with down the hole hammer drilling rig or combination drilling rig (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of EIC including use of own rigs with its accessories, T&P & consumables etc. for lowering of 200mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/ PVC casing pipes, if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the Tube Well).Labour for drilling of 200mm dia & 150mm dia bore from \"0\" mtr. to \"100\" mtr. |
| 164 | Providing & lowering the following size PVC pipes (ASTM) with or without slottedpipes as per the necessity from 1.00m above ground level up to required depth and fitting and fixing up in perfectly vertical position, including cutting, threading pipe and slotted pipe and supplying and fixing all jointing materials, T&P etc. complete and keeping the top of the casing pipe threaded including plugging the tube well to prevent entry of foreign materials from above. The cost inclusive of pipes, fittings, labour, consumables, POL, consumables with hire & running charges of machinaries etc. as per specification & direction of EIC.Lowering of 200mm (8\"\") dia PVC plastic pipes Sch-80 as per ASTM-D-1785/2004 upto required depth. |
| 165 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 166 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 167 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 168 | Supplying all materials, labours, T&P, fitting and jointing of 80mm dia double flanzed column GI pipe confirming to IS 1239/1968, medium class having IS mark of approved make / tata medium series with socket and screw joint including supply, fitting and fixing of required number of IS certified fitting, cutting threads to pipe and pipes to length including wastage providing necessary offsets and lay screw with extra socket and jam nut including fixing to wall and floors with supply of holder bats, clamps, fixing wooden plugs in walls complete as per direction of Engineer-in-charge. |
| 169 | Supply, installation, testing and commisioning of vertical submerssible pump set of approved make having required discharge including installation of pump set withwire ropes, clamps etc inside the borewell, etc complete as per the Direction of Engineer-in-charge. (Duty of pump to be decided depending upon yeild of the borewell) |
| 170 | Supply, installation, testing and commisioning of automatic star delta control panel suitable for pumpset including MS box fitted with main switch ,contactor, single phasing preventer, timer, selector switch, voltmetre, ammeter etc and connection with motor inside the borewell complete as per the Direction of Engineer-in-charge. (Excluding power supply and flat cable for connection with motor) |
| 171 | Protection to the Borewell with CC base |
| 172 | 3 core 6.0sqmm copper flat cable |
| 173 | Bore Cap |
| 174 | Clamp |
| 175 | Supplying all materials, labours, T&P and fitting and fixing of the following size of UPVC pipe (Sch-80)confirming to ASTM D1785 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge.(Non Concealed) |
| 176 | 80mm Dia |
| 177 | 65mm Dia |
| 178 | Supplying all materials, labours, T&P, fitting and jointing of following dia GI pipe confirming to IS 1239, medium class of approved make / tata medium series with socket and screw joint including supply, fitting and fixing of required number of IS certified fitting, cutting threads to pipe and pipes to length including wastage providing necessary offsets and lay screw with extra socket and jam nut including fixing to wall and floors and lay inside trench with supply of holder bats, clamps, fixing wooden plugs in walls complete as per direction of Engineer-in-charge. |
| 179 | 63mm Dia |
| 180 | Supplying all materials, labour, T&P, fitting & fixing of different size UPVC Ball Valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and direction of the Engineer-in-charge. |
| 181 | 80mm Dia |
| 182 | 65mm Dia |
| 183 | Supplying all materials & labour, T&P and constructing brick masonary chamber for water sluice valve, single air valve & non return valve with flyash brick masonary in cement mortar (1:4) as per approved drawing and specification CC (1:4:8) with 4cm size hard granite metal on the bed, 12mm cement plaster (1:3) to inside and cement flush pointing (1:3) to outside surface with 100mm thick RCC M20 cover slab with 12mm hg chips using required quantity of tor steel, centring and shuttering to the slab and dismantling it after 31 days of casting, filling the outside cavity with excavated materials, watering, curing including cost, conveyance, taxes of all materials, labour charges for cutting, bending, binding and tying the grills in proper position etc all complete as per direction of Engineer-in-charge.Sluice Valve Chamber (0.75x0.75x1.20mtr) |
| 184 | Providing & fixing of following dia UPVC body non return valve of approved make with high tensile bress rising stem suitable for the system pressure as per IS specification. |
| 185 | 80mm Dia |
| 186 | 65mm Dia |
| 187 | Supplying all materials, labour, T&P, fitting & fixing of different size bourden type pressure gauge (0-10 kg/sqcm) with valves, piping, fitting of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and as per the direction of the Engineer-in-charge. |
| 188 | Supplying all materials, labour, T&P and fitting and fixing of air release valve of 50mm Dia confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge. |
| 189 | Supply, installation, testing and commisioning of automatic star delta control panel suitable for 10HP pumpset including MS box fitted with main switch ,contactor, single phasing preventer, timer, selector switch, voltmetre, ammeter etc and connection with motor inside the sump with suitable cable etc complete as per the Direction of Engineer-in-charge. (Excluding power supply) |
| 190 | Supply, installation, testing and commisioning of horizontal centrifugal pump set of approved make having discharge 20m3 per hour and 50mtr head including installation of pump set with suitable base plate and foundation inside the sump, delivery arrangement with suitable GI or MS pipe providing valves fittings etc and connection within 10mtr distance etc complete as per the Direction of Engineer-in-charge. |
| 191 | Providing & laying cement concrete of prop. (1:4:8) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. |
| 192 | Supplying and fixing stainless steel ladder of approved gauge of 3 mtr long and required width inside under ground tank including cost of all materials, labour, T&P etc complete as per approved drawing, design and direction of Engineer-in-charge. |
| 193 | Supplying all materials, labour, T&P for fitting and fixing of puddle collar of 150mm dia of approved make etc complete as per direction of Engineer-in-charge. |
| 194 | Supplying all materials, labour, T&P for fitting and fixing of vent pipe of approved make etc complete as per direction of Engineer-in-charge. |
| 195 | Design, supplying, installing, testing & commissioning of EffluentTreatment Plant 0.050MLD (excluding all Civil & construction work) for the following duty:Nature of Washing -Bus-cleaning Effluent Daily average flow - 50cum/day pH - 6.5 – 8.5BOD5 - upto 600 Mg/LS. Solids - 400 Mg/LCOD - upto 800 Mg/LOil & Grease - 100 Mg / LColiform - 106 - 107 MPN/100 MLEffluentdischarge to STP for biological treatment and rlease to Surface /drain.PH - 6.5 – 8.5BOD5 - Less than 250 Mg/LS. Solids - Less than 200 Mg/LCOD - Less than 300Mg/LSupply, installation, testing & commissioning of 2 Nos Stainless Steel Perforated, 25mm,10mm, Course & 6 mm FineBar Screen with suitable lifting arrangementwith brackets in the sreen sump of (size 500 mm x 1500mm depth approx) |
| 196 | Supply of MS hot dip galvanized puddle collarsin accordance to BS:10 table D as required to be provided (in the structural slab and wall) of various diameters. Puddle collarsshall be provided for all the structural component of the STP. The installation of the puddle flanges shall be carried out by the Civil contractor in accordance to the Civil GA drawing (to be prepared by the STP contractor) at the required levels& position; under the supervision of the STP contractor |
| 197 | Supply of plastic encapsulated step/foot rest (@ 300 mm c/c) with polypropelene compound injection molded around 12 mm dia mild steel reinforcing bar. Provision of the foot rest is envisaged in various tanks/ components of the STP for the purpose of accessability. The installation of the foot rest shall be done by the civil contractor as per civil GA drawing |
| 198 | Supply, installation, testing & commissioning of CI medium duty manhole cover with frame for the feasibility of access in the tank Size : 1200 x 1000 (175 kg) |
| 199 | Air diffusing mechanism for the colletion system of the ETP EQT with SS piping system and the Flash mixture on the premixing tank to EQT as per the detailed P& ID drawings. Air piping shall comprise of pipes droppers with SS complete with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports& clamps, puddle flanges etc cutting chases& making good. Contactor to submit detailed P & I indicating their proposal |
| 200 | Supply, installation, testing & commissioning of electronic type level indicator, instrumation and controller for automatic operation of the system with high/low level alarm complete with auxillary NO/NC contacts. Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned component and additional component if so required for the complete working of the ETP. |
| 201 | Supply, installation, testing & commissioning of non clogging type pumps capableofhandlingsolidsupto 15 mm having C.I casing& C.I impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automaticallyCapacity 3 M3/hr each (feed Pass / Sludge Re-circulation)Head 12-15 MtsRPM2900 |
| 202 | Supply, installation, testing & commissioning of non clogging type pumps capableofhandlingsolidsupto 15 mm having C.I casing& C.I impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automatically.Pumpsshall have following duty:Capacity 3 M3/hr each Head 12-15 MtsRPM2900 |
| 203 | Supply and fixing of Oil skimmer with belt to remove surfectant and emulsified oil from the waste with drive motor reduction gear and ccrapper collectordrum complete with all acessories . |
| 204 | Settler mechanism for primary settling with Hexagonal Tube settler with MSEP rack support and open able bracket/MH and support frame for clarifier unit of size 750 mm long and with end locking arrangement ,the inclination of 51’ is required ,end lock sud have the surface locking arrangement in rack etc (media min approx 12 m3) with all fittings and fixtures as required for clarifier as directed by engineer in charge at site. |
| 205 | Piping (heavy class) in MS/GI/SS/PVC/HDPE as per the approval of the consultants, to be designed for suitable and corrosion resistance complete or as directed by engineer in charge at siteNOTEContractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned components and additional components such as inserts, puddle flanges, vent pipes etc.if so required for the complete working of the STP and got it approved by the Owner’s Architect / engineer in charge/ Consultants.All Civil works finished with waterproofing, plaster, snowcem, structure duly tested for leakproofing, plant room flooring, equipment foundation etc and related MS/CI works such as supply and fixing of Puddle Flanges, MS / CI grating, Inserts, handrails, Manholes with covers, gratings, grills, Doors, vents, lighting footrests etc shall be in the scope of the Client / Civil Contractor. |
| 206 | TERTIARY TREATMENT PLANTSupplying, installing, testing and commissioning ofhorizontal single/multistage centrifugal filter feed pump complete in SS impeller CI casing . Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plateSS Shaft/ Impeller/ Intermediate chamber. Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. of capacity 3 M3/hr @ 25 MWC.(1 W + 1 St by ) Suitable back washing of the system withpump for filters as required (1 W+ 1 stand by) one of the above |
| 207 | Providing, fixing, testing& commissioning ofFRPwaterfiltrationplantMMF(suitablefor3.5 Kg/Sqcm workingpressure)completewith initial charge with sand /silex media, 1.5\" MPV prahar (imported)valves with built in frontal pipe work with back washsystem, pressure gauge at inlet, outletandback wash (each with isolation cock), valves,fittings associatedworks. Pr Vessel MOC – FRP Pr Vessel dia/hos –21\"X62\" TSS200Mg/LBack WashPeriod12Hrs.Operating Pressure 3 Kg. per sq.cmTest Pressure7.5 Kg. Sq.cm.Capacity 3000Lts/Hr |
| 208 | Supply, installation, testing & commissioning of Hypochloridedosing system for tertiary water treatment with 200 L .HDPE/PVCtank with lidetc Unit flow :5LPH |
| 209 | Approvalfrom pollution boardat initial & various other stagesof worksincludingpreparation of report/drawingsas perpollution board requirement, arrangementof rawsewage for testing&commissioning.Contractor shall include the cost of allchemicals (consumed during testing & commissioning and the cost of such items of works whichare notexplicitly mentioned above, but are mandatory to have pollution board approval. |
| 210 | ELECTRICAL INSTALLATION FOR ETPDesign, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables (in accordance to specification) with earthing from panel to each motor / equipment.ETP Motor Control CentreIncomingDistribution panel with bus bar etc as std required.MCC for ETP as described above |
| 211 | Supplying & laying offollowing 1100 voltgradePVC sheathed aluminum/copper conductor armoured cables as per specification in existing trenches, cable trays, ducts over bed of sand, clamped to wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. as site suitable quantities as per site. |
| 212 | 4 core 2.5 sq. mm copper cable |
| 213 | 8SWG Cupper wire |
| 214 | Gravel(Quartz) filling to the filtration chamber with good quality gravel, mixing with water to make it to a plastic state and proper backing as per correct profile including cost conveyance royalty and other taxes of materials with all labour T&P materials required for the item complete as directed by the Engineer-in-charge. |
| 215 | Supplying & fixing Filter Media consist of charcol, pebbles, filtering sand as per the detailed drawing and direction of Engineer-in-charge. |
| 216 | Supplying all materials, labour, T&P, fitting and laying in trenches PVC pipes & fittings of approved make confirming to IS-4985 and specials of the following outside diameter and classes including jointing with supply of approved solvent cement by non heat application method including testing etc complete as per the PH specification and direction of the Engineer-in-charge. (Earthwork to be measured separately) |
| 217 | 110mm Dia |
| 218 | 160mm Dia |
| 219 | Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of bedding for pvc pipes of the following internal diameter including curing complete as per specification |
| 220 | 110mm Dia |
| 221 | 160mm Dia |
| 222 | Supplying all materials, labour, T&P and fitting and fixing of PP flanzed end ball valve of 100mm Dia confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge. |
| 223 | Mechanical Filter |
| 224 | Fine dressing of earth work in ordinary or hard soil in ground formaton according to the direction of the Engineer in Charge including cutting or filling earth uptoincluding removal and disposal of top organic soil not exceeding 150 mm in thicknessincluding cost of all material, labour, conveyance, loading and un-loading, taxes, royalties, sundries, tools and plants, etc., complete as per the direction of the Engineering-in-charge/Consultant. |
| 225 | Rolling & compacting to sub grade or formation loosening by cutting earth for 15cm below the sub grade including watering and compacting in layers by PRR, cost & conveyance of required quantity of water, cost of all labour sundries, T & P etc. required for the work to complete in all respect as per specification and direction of Engineer-in-charge. |
| 226 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) etc complete as per direction of Engineer-in-charge. |
| 227 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works |
| 228 | Supplying and laying of M40 grade heavy duty factory made hydraulically pressed and mechanically compacted free cast interlocking coloured pavers of 80mm thick in approved pattern, coral shaped preparation of sub base with 50mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-chrge. |
| 229 | Supplying, fitting and fixing in position 25mm thick cement concrete tile of Ultra category-1/Eurocon or equivalent type of approved make, quality, colour and size in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient grouted with neat white cement slurry with required quantities of pigments of approved marks watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work complete in all respect as directed by the Engineer-in-charge |
| 230 | Providing and laying/sprinkling non metallic heavy duty floor hardener @ 3.0 kg per sqm over the wet concreteincluding finishing the same as per the direction of the manufacturers specifications. Contractor has to submit the material for approval before each panel pour as per the prescribed consumption factor. Approved Make ; Sika, STP, Fosroc |
| 231 | Providing Vacuum Dewatering Pump to remove the air voids, water for quick setting the concrete, bull floating and striking of, power toweling, adding floor hardener with policing by using disk blade in Trimix flooring including cost of all materials labour T&P etc complete as per direction of Engineer in charge. |
| 232 | Providing & laying bituminious expansion joint 12mm thick as per requirement & instructions of the Engineer-in-charge. |
| 233 | Providing & laying M - 20 grade pre-cast concrete kerb stones of size 300x300x150 mm thickincluding setting in cement mortor 1:4 ( 1 cement : 4 coarse sand) and pointing of joints with same mortor etc. complete. |
| 234 | Reclamation of works likecleaning of total area, cleaning of unwanted shrubs, stumps uprooting rank, vegetation, unwanted grass, wood, twigs, breaking clods, tilling of area, dumping of above materials at required spots, lifting of the above materials from the gardenarea of the premisesto outside by mechanical means including loading & unloading chargesas per the instruction of Officer-in-charges. |
| 235 | Supply of good quality garden soil preferably red alluvial /sandy loam with texture neither too coarse nor too fine with a fair degree of water retaining capacity sufficiently porous for microbial activity, containing adequatehumus with a Ph range from 6.5 to 7.5 should be freefrom any undesirable inorganic materials like wastages of construction, roots and bushes of wild plants, polythene, garbage etc., to be collected after duly screened including cost, conveyance, royalty, taxes andother chargeswith labour and T & P charges for loading, unloading and stacking at site in the separate heaps of ( 1.5 x 1.5x 0.5) cumor its multiples taken into 1(one) cum for measurement and payment purposes and completed in all respect for the park. |
| 236 | Lifting & spreading of good soil uniformly over the surface area as per landscape design /advice of the site in-charge. |
| 237 | Supply of cow dung manure, well decomposed, garbage free, one Tractor load including loading, unloading and delivery at site. |
| 238 | Lifting & Spreading of manure uniformly as per the direction of site in-charge. |
| 239 | Hoeing of soil & manure spreaded area over an area of approx. 7500 sqmtr. For smooth mixing in the upper Surface & leveling, dressing for grassing the area as per the instruction of Officer in-charge |
| 240 | Supply of Bermuda bent grass / Zoicia japonica / shade loving grass well grown disease free, carpet formed, 2” thickness about for an area of 1000 sqm. in 1:5 i.e.,600 sqm.Including loading and unloading and delivery at site including cost of all materials, transportation etc complete as per direction of Engineer-in-charge. |
| 241 | Supply of Broad Leaf grass well grown disease free, carpet formed, 2” thickness about for an area of 1000 sqm. in 1:5 i.e.,600 sqm.Including loading and unloading and delivery at site including cost of all materials, transportation etc complete as per direction of Engineer-in-charge. |
| 242 | Dibbling of Broad leaf grass including watering, rolling, As per the instruction of Officer-in charge for 3100 sqmtr. |
| 243 | Planting of Nerium Olender 3’ ht. ornamental plants, well established healthy disease free in poly bag/ big container including transportation anddelivery at sites. |
| 244 | Planting of Murya Exotica 4’ ht. ornamental plants,well established healthy disease freein poly bag/ big container including transportation and delivery at sites. |
| 245 | Planting of Bouganvelliea 3 ½’ ht. ornamental plants,well established healthy disease freein poly bag/ big container including transportation and delivery at sites. |
| 246 | Planting of Ixora Coccinea 2 ½’ ht. ornamental plants, well established healthy disease freein poly bag/ big container including transportation anddelivery at sites. |
| 247 | Planting of Gardenia Grandiflora 2 ½’ ht. ornamental plants, well established healthy disease freein poly bag/ big container including transportation anddelivery at sites. |
| 248 | Planting of Tecoma Stans 2 ½’ ht. ornamental plants, well established healthy disease freein poly bag/ big container including transportation anddelivery at sites. |
| 249 | Planting of Almonda Cathritica 3’ ht. ornamental plants, well established healthy disease free in poly bag/ big container including transportation anddelivery at sites. |
| 250 | Planting of Jasminum species 3’ ht. ornamental plants, well established healthy disease free in poly bag/ big container including transportation and delivery at sites. |
| 251 | Planting of Musanda species 3’ ht. ornamental plants, well established healthy disease free in poly bag/ big container including transportation and delivery at sites. |
| 252 | Planting of Croton species4 ’ ht. ornamental plants, well established healthy disease freein poly bag/ big container including transportation anddelivery at sites |
| 253 | Planting of Mini Tagar 2’ ht.well grownhealthy plant species as per specified height all saplings are of healthygrown well canopy, disease free etc. includingtransport and deliveryat site. |
| 254 | Planting of Tarata dwarf 2’ ht.well grownhealthy plant species as per specified height all saplings are of healthygrown well canopy, disease free etc. includingtransport and deliveryat site. |
| 255 | Planting of Varigated Tagar 2’ ht.well grownhealthy plant species as per specified height all saplings are of healthygrown well canopy, disease free etc. includingtransport and deliveryat site. |
| 256 | Planting of Hena 2’ ht.well grownhealthy plant species as per specified height all saplings are of healthygrown well canopy, disease free etc. includingtransport and deliveryat site. |
| 257 | Planting of Musanda red 3’ ht. ornamental plants, well established healthy disease free in poly bag/ big container including transportation anddelivery at sites. |
| 258 | Planting of Fox tail palm 7’ ht ornamental decorative specimen plants well established healthy disease free in poly bag/ big container including transportation and delivery at sites.Planting of each plant at specified location by application of fertilizer and pesticide as required as per instruction of Officer in-charge. |
| 259 | Planting of Arica palm 7’ ht ornamental decorative specimen plants well established healthy disease free in poly bag/ big container including transportation and delivery at sites.Planting of each plant at specified location by application of fertilizer and pesticide as required as per instruction of Officer in-charge. |
| 260 | Planting of Phoneix 3’ ht ornamental decorative specimen plants well established healthy disease free in poly bag/ big container including transportation and delivery at sites.Planting of each plant at specified location by application of fertilizer and pesticide as required as per instruction of Officer in-charge. |
| 261 | Planting of Furcaria Watsonai 2’ ht ornamental decorative specimen plants, well established healthy disease free in poly bag/ big container including transportation and delivery at sites. Planting of each plant at specified location by application of fertilizer and pesticide as required as per instruction of Officer in-charge. |
| 262 | Planting of Juniper 3’ ht ornamental decorative specimen plants well established healthy disease free in poly bag/ big container including transportation and delivery at sites.Planting of each plant at specified location by application of fertilizer and pesticide as required as per instruction of Officer in-charge. |
| 263 | Planting of Fish tail palm 7’ ht ornamental decorative specimen plants well established healthy disease free in poly bag/ big container including transportation and delivery at sites.Planting of each plant at specified location by application of fertilizer and pesticide as required as per instruction of Officer in-charge. |
| 264 | Planting of Pichadia palm 7’ ht ornamental decorative specimen plants well established healthy disease free in poly bag/ big container including transportation and delivery at sites.Planting of each plant at specified location by application of fertilizer and pesticide as required as per instruction of Officer in-charge. |
| 265 | Providing Circular Cement Concrete pots of top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 nos ( 3 nos horizontal & 4 nos vertical \"U\" shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge. |
| 266 | Supply of hedge and edge plant, healthy disease free in poly bag/ container including transportation and delivery at sites.Planting of Duranta Goldiana/ Duranta Varigataed (Poly)8” ht. i.e.,7 nos. per meter @ Rs. 10/- Per Plant (7 nos.x 4 line x area x Rs.10/-)Planting of each plant at specified location by application of fertilizer and pesticide asrequired as per instruction of Officer in-charge. |
| 267 | Providing and fixing overhead type sprinkler system with self closing valve type 25mm X 20mm with self closing springmade up ofalluminium alloy and brass fittings including cost of all materials, labour, T & P etc complete as per direction of Engineer-in-charge. |
| 268 | Supplying all materials , labours , taxes and tools and plants for fitting and fixing of 20mm dia CPVC pipes of 100% lead free and conforming to ASTM F442 Specific-2 CPVC(Make-ASTRAL/ASHIRBAD /Equivalent) with good quality including fittings and laying as per the site requirement etc., all complete including testing as per the direction and specification of Engineer-in-charge. |
| 269 | Providing kota stone flooring using kota stone of approved quality, colour and size of 20mm minimum thick in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the kota stone with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the kota stone, if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 270 | Supplying, fitting and fixing in position, 25mm minimum thick kota stone of approved quality and size in dadoes in all floors at all heights and riser of steps on 12mmm thick cement plaster (1:3) using screened and washed sharp sand for mortar with grouted with neat cement slurry and jointed with neat cement slurry mixed with required shadeof pigments to match the shade of the tiles including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, curing-sundries and T&P, etc. required for the work complete as per specification and direction of Engineer-in-charge. |
| 271 | Providing and Fixing white/diamond gray finish system aluminum doors & windows make: Fenesta, Schuco, Reynaers, Aluko. Company must have own fabrication facilities & control the entire cycle from fabrication to Installation to post Sales Service. Aluminum profile frame should be powder coated of 65-90 micron, using vertical coating process from a QUALICOAT certified facility and profile must be undergo sublimation process for transferring wood grain patterns on it. Windows & doors profile must be of high grade 6063 T6 and gauge should be vary from 1.2 mm to 4.5 mm as per the design & system requirement. All hardware fitted must be of Non-SS, except handles to be of zinc/Al. alloy casted with powder coated. Glass should be of make: Saint-Gobain/ Modiguard/ASAHI with 6 mm clear toughened + 12mm gap +6 mm clear toughened or as per approved given specification with weather seal (EPDM/TPE). Window/Door provider should have it’s presence PAN India and having experience of minimum 12 Years of any type of window & doors in India.Providing and fixing Casement single/double open able panel door with 3D hinges made of frame 45 mm x 67.7 mm and sash 52 mm x 98.5 mm all having wall thickness 1.2 mm to 1.4 mm and single glazing bead of appropriate dimension for 6mmT +12mm gap +6mmT clear toughened Glass or as per approved given specification. |
| 272 | Providing and fixing two track two panel sliding window made of frame 45mm x 37.5 mm and sash 28 mm x 68 mm. for doors outer frame will be 92 mm x 38 mm and sash will be 34.5 mm x 75 mm both having wall thickness of 1.2 mm to 1.4 mm as per approved drawing/design. Window/door should have single glazing bead of appropriate dimension for 6mmT +12mm gap +6mm T clear toughened Glass or as per approved given specification. |
| 273 | Fix Ventilator made of frame 45 mm x 50.5 mm and mullion (if required) 48 mm x 61mm both having wall thickness 1.2 mm to 1.4 mm and single glazing bead of appropriate dimension for 4mm pin head louvers glass in case of louver ventilator and arranhement for exhaust fan of 300mm dia. |
| 274 | Providing Tata square or circular structural steel work welded in built up sections, tubular trusses and framed work including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer etc complete including all cost of labour, T & P, hire charges of drilling machine, etc. complete with door stoper, handle, lock & floor spring as per specification and direction of Engineer-in-charge. |
| 275 | Supplying, fitting and fixing of precoated galvanized Corrogated steel sheet (cril or equivalent) of 0.4mm thickness ( prepainted on hot dip galvanized substrate) organic (colour coated) finished profiles with necessary lapping, bolting etc. complete including fixing of ridges wind tieswith help of J hook size 1’-0” with required nut bolt etc. complete including cost of all materials, labour, all taxes, sundries, T&P and transportations complete in all respect as per design and drawings as directed by the Engineer-in-charge. |
| 276 | Gutter |
| 277 | Supplying, fitting and fixing of M.S square bar grill with top and bottom rails( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damagedwalls/ structures with cement concrete (1:2:4)with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge. |
| 278 | Supplying, fitting and fixing of M.S grill gates with top and bottom rails( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damagedwalls/ structures with cement concrete (1:2:4)with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge. |
| 279 | Supplying all materials, labour, T&P and necessary materials towards laying of RCC NP2/NP3 Hume pipe push tight joint type (including cost of RCC Hume pipe) inside the pipeline trench of required size with plastic rope without damage to the pipe with all convenience the materials to site and including all taxes all complete as per direction of Engineer-in-charge.450mm Dia NP3 |
| 280 | Construction , Providing , Supplying and fixing the pre-cast , pre-tensioned SFRC compound wall poles having finished dimention of 200mm x 200mm x 300mm long, (providing the construction joint at the interval of 15.4 mtr) made in M-30 grade concrete with 10 Nos of 4mm dea. HTPC ( High Tension Pre-Coated) wire, fixed in cast –in-situ PCC m-20 concrete in foundation footing of size 600 mm dia 750 mm depth from top inside the pre-castRCC collar ( NP-2) of 600 mm Internal dia. & length of 750 mm placed over a base of PCC ( 1:4:8) of size 680mm dia, 100 mm depth including excavating foundation pit for each pole, kind of soil of size 680mm dia, 850mm depth ( at expansion joint of 15.4 m interval where combined poles are to be places with 900mm internal dia of NP-2 collar of 750mm height) including watering & curing for required days along with supplying, fitting & fixing of pre-cast , pre-tensioned, SFRC slab having dimention of 2100mm (long) x 300mm (Wide)x 500 ( thick) 7.5 Nos. per span, made with M-30 grade concrete with 4mm dia. GI HTPC wire 4 Nos. covering the top of the compound wall poles with a pre-cast SFRC cover of size ( 300x300x150) mm in order the prevent the slab panels from removing . all complete as a set to be measured in term of running meter including such pre-cast , SFRC top cover, slab, pole, including painting two coats of approved weather coat paint over a coat of wall primer including curing cost and conveyance of all materials, royalties, taxes all labour, labour cess, T&P required for the work etc. complete including dewatering if required as per the direction of the Engineer-in-Charge(Excluding cost of GST) |
| 281 | 25 mm. average thick artificial stone flooring with cement punning laid to proper slope with cement concrete of proportion (1:2:4) using screened and washed sharp sand for mortar with black hard crusher broken granite stone chips of approved quality and from approved quarry, washed and cleaned laid in two layers i.e. the bottom layer being 19 mm . thick and top layer of 6mm. thick with 12mm. to 20. size black hard crusher brokenstone chips (20mm size chips not to exceed 25%) including chipping and chiseling and cleaning the top surface of the floor slabs in upper floors, including rounding of corners, watering and curing with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge |
| 282 | Supplying, fitting and fixing of MS openable door with 35 x 35 x 6mm size M.S. angle frame as chowkath and 30x30x5mm Ms frame for shutter with 25x6mm flat fabricated to proper size of door opening with 16 gauge CR sheet including fixing clamps for door frames and hinges for fixing shutters and aldrop with tower bolt etc. complete for all floors including cost, conveyance, taxes of all materials, labour, T&P etc.required for the work etc. complete in all respect as per direction of Engineer-in-charge. |
| 283 | Supplying all materials, labour, T&P for fitting and fixing of water level indicator made of MS flats and plates with lablling etc complete as per direction of Engineer-in-charge. |
| 284 | Providing and rough stone dry packing in approans and eventment with hard granite stones 150mm to 300mm including cost of all materials, labour T&P etc complete as per direction of Engineer-in-charge. |
| 285 | Wiring to light points/fan point/exhaust fan point/Call bell point with 1.5-sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non metalic PVC flexible condute with 6Amp, 250V Modular Switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. (Make of wire-Finolex/ L&T/ Anchor/ Havells/ KEI) |
| 286 | Primery point |
| 287 | Secondary point |
| 288 | Call bell point |
| 289 | Wall bracket fan point specification same as above. |
| 290 | Exhaust fan point specification same as above. |
| 291 | Ceiling fan point consisting of modular regulator of Legrand make model name Myrius or equivalent on existing switch board |
| 292 | Supply and fixing of 6Amp plug with 6amp switch on existing board (Modular type ISI marked) |
| 293 | Point wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with modular type switch, phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required. (convinient power) (Make of wire-Finolex/ L&T/ Anchor/ Havells/ KEI) |
| 294 | Supply and fixing of ISI marked modular type 2nos 6Amp plug with switch on suitable size of metal box and modular cover in fronton surface or recess including all conection. |
| 295 | Supply and fixing of modular metal box on surface or recess with suitable size of modular cover in front including providing an fixing of ISI marked 16Amp plug with switch with all conection. |
| 296 | Supply& fixing of Modular type 25 Amp one way switch and socket outlet for AC point with metal box and modular cover. |
| 297 | Recessed/surface extra lead submain wiring alongwith earth wire with the folowing size of PVC insulated single core multistrand coper conductor of ISI marked conforming to IS 694/1990 in 20mm dia non metalic heavy duty flexible condute 1.6mm in surface/recessed PVC condute as required (Make of wire-Finolex/ L&T/ Anchor/ Havells/ Great White/ KEI) exceeding to Long point in 2x1.5sqmm + 1x1.5sqmm. |
| 298 | Submains:Recessed/surface submain wiring alongwith earth wire with the following size of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in required dia non metalic heavy duty flexible condute 1.6mm in surface/recessed PVC condute as required. (Make of wire-Finolex/ L&T/ Anchor/ Havells/ Great White/ KEI) |
| 299 | 2 x 2.5 sq.mm. + 1 x 1.5 sq.mm. |
| 300 | 2 x 4.0 sq.mm. + 1 x 1.5 sq.mm. |
| 301 | 2 x 6.0 sq.mm. + 1 x 2.5 sq.mm. |
| 302 | 2 x 10.0 sq.mm. + 1 x 4.0 sq.mm. |
| 303 | 4 x 2.5 sq.mm. + 2 x 2.5 sq.mm. |
| 304 | 4 x 4.0 sq.mm. + 2 x 2.5 sq.mm. |
| 305 | 4 x 6.0 sq.mm. + 2 x 2.5 sq.mm. |
| 306 | 4 x 10.0 sq.mm. + 2 x 4.0 sq.mm. |
| 307 | 4 x 16.0 sq.mm. + 2 x 10.0 sq.mm. |
| 308 | Supply, delivery, installation, testing and commssioning of modular type TV Antenna/Telephone Outlet Boards containing a ISI markedModular TV Antenna/Telephone Socket fixed on Modular Concealed Box including connections and making good the damages caused complete as required and as per Dierction of Engineer-In-Charge. |
| 309 | Supplying and drawing TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in existing surface / recessed steel / PVC conduit as required. |
| 310 | Supplying and drawing 2 pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed steel / PVC conduit as required. |
| 311 | Supply and laying of following size rigid PVC conduit pipe (medium ) through floor / wall / partition with GI spacer clamps or as directd.Rate to include for accessories - bends,sockets T\"s etc. |
| 312 | 19 mm dia |
| 313 | 25 mm dia |
| 314 | 32 mm dia |
| 315 | Supply, delivery, installtion, testing and commissioning of indoor floor mounted type distribution boards for common area made out of high quality polycarbonate (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material), UV resistant, having high grade gasket made of polyurethane, should withstand glow wire test at 9600C, should be flame retardant, the cabinate should have test certificate in accordance with IEC 60 439-1 (IS8623), IEC 60 439-2, CPRI (ASTA) (Party should submit copy of all test certificates during offer submitting) The panel should have hinged door with provision for cable entry, earthing studsasper specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete including necessary civil / fabrication work as requiredas per the direction of Engineer-in-charge.All MCCB shall confirm to IEC- 60947 and IS-13947. MCCB shall comply with the isolation function requirement of IEC-60947-2 section 7.1.2 to be marked as suitable for isolation / disconnection to facilitate safety of person in use. All MCCB have ics=100% icu and the overload setting should be from 0.7 to 1 times of Ir for thermal magenetic release and for microprocessor release the overload Settings: 0.4 to 1 times of Ir. Manually closing mechanism should be Cont. next row |
| 316 | accommodated in a Moulded housing of robust and vermin-proof construction. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) . The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material.Main Distribution Board for Building.incoming MCCB: 1 No 40A (25kA) 4P Thermal Magnetic with ROM & spreader links.SPD: 1No 50kA 4P T1+T2MCB \"C\": 1 No 63A 10kA 4PCHANGE OVER SWITCH : 1 no 40A 4P On Loadoutgoing Busbar : 1 SET, 4Nos 50 Amp Copper Strips. (CD=1.6A/sqmm)MCB \"C\": 2 No 63A (10kA) 4P.MCB \"C\": 1 No 32A (10kA) 4P.MCB \"C\": 3 No 32A (10kA) 2P.Instruments: 1 Set of LED type RYB phase indicating lamps with control fuses & 1no multi function meter with required CT\"s |
| 317 | Supply, delivery, installation, testing & commissioning of L.T. indoor floor/ wall mounted type distribution boards made out of reputed company IP 43 - #IK 09 with metal door having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISSandasperspecial conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. |
| 318 | Light/Comp/Power. DB ( 8way SPN DB)incoming 1 no of RCCB: 25A (100mA) 4Poutgoing 6 nos of 6-32A SP MCB as per SLD |
| 319 | Light/Comp. DB ( 4way TPN DB)incoming 1 no of RCCB: 25A (100mA) 4Poutgoing 12 nos of 6-32A SP MCB as per SLD |
| 320 | Raw Power DB ( 4way TPN DB)incoming 1 no of 63A 4P MCB outgoing 12 nos of 6-32A SP MCB as per SLD |
| 321 | Fittings & FixturesInstallation and testing offollowing types of fluorescent tube fixtures directly on wall / ceiling of building with allaccessories such as electronics ballast, fluorescent tube lights, stove enamelled box, perpex sheet cover etc complete assembly including supply & fixing of teak wood round block and making connection from the suitable point outlet as per the direction of Engineer-in-charge. |
| 322 | Supply, delivery, installation, testing & commissioning of Basic all purpose surface and wall mounted 20 watt LED batten with Aluminum housing & integrated electronic driver having THD<20%. (Make: Bajaj/ Philips/ Havells/ Wipro) |
| 323 | Supply, delivery, installation, testing & commissioning of Basic all purpose surface and wall mounted 10 watt LED batten with Aluminum housing & integrated electronic driver having THD<20%. (Make: Bajaj/ Philips/ Havells/ Wipro) |
| 324 | Supply, delivery, installation, testing & commissioning of 7w LED Bulb on existin holder. (Make: Bajaj/ Philips/ Crompton/ Havells/Wipro) |
| 325 | Supply, delivery, installation, testing & commissioning of 36 watt LED edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications. (Make: Bajaj/ Philips/ Havells/ Wipro) |
| 326 | Supply, delivery, installation, testing & commissioning of 6 watt Slim-Fit low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology. An ideal solution where ceiling voids are limited but high lumen output is required. (Make: Bajaj/ Philips/ Havells/ Wipro) |
| 327 | Supply, delivery, installation, testing & commissioning of 12 watt Slim-Fit low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology. An ideal solution where ceiling voids are limited but high lumen output is required. (Make: Bajaj/ Philips/ Havells/ Wipro) |
| 328 | Supply, delivery, installation, testing & commissioning of 8W LED tiltable recessed downlight fixture made of extruded Aluminium housing and high power LED as a light source with clear diffuser and separate electronic driver. (Make: Bajaj/ Philips/ Havells/ Wipro) |
| 329 | Supply, delivery, installation, testing & commissioning of Flexible LED strip uses high brightness SMD LED as the light source for indoor application only. It is highly suitable for cove-lighting, decorative lighting etc (Make: Bajaj/ Philips/ Havells/ Wipro) |
| 330 | Supply, delivery, installation, testing & commissioning of 50w Energy saving, environment friendly & robust IP65 protected LED midbay with PDC housing suitable for ceiling (Surface/Suspended) mount & available in Wide beam optics. (Make: Havells cat noILIOSBAYPLUSHBP50WLED857SP90DTOPC) |
| 331 | Supply, delivery, installation, testing & commissioning of BEE Star rated 1200mm sweep cealing fan (Crompton/ Orient/ Havells/ Bajaj) |
| 332 | Supply, delivery, installation, testing & commissioning of wall mounting fan 400mm sweep (Crompton/ Havells/ Bajaj) |
| 333 | Supply, delivery, installation, testing & commissioning of metal Exhaust fan 12\" sweep (Crompton/ Havells/ Bajaj) |
| 334 | Supply, delivery, installation, testing & commissioning of plastic Ventilation fan 150mm sweep (Crompton/ Havells/ Bajaj) |
| 335 | Supply & Fixing of electronic call bell ding dong two modular on entrance door way and as per the direction of Engineer-in-charge or Consultant. |
| 336 | 2KVA INVERTER WITH 90 MINUTE BATTERY BACKUPSupplying, receiving, storing, handling erecting, testing and commissioning of 2KVA Inverter with 90Minute battery backup including battery rack within enclousre cabinet |
| 337 | UPS ISOLATION ENCLOSURE / MCB METAL ENCLOASURESupplying, receiving, storing, handling erecting, testing and commissioning of 1 No. 63A FP MCB (10 kA), C - Curve in suitable powder coated MS Box with suitable link. |
| 338 | Supply, installation, testing and commissioning of 63 Amp 2 pole Isolator with metal enclosure box with interconections, earthing etc. as required. |
| 339 | Supply, delivery, installation, testing & commissioning of L.T. indoor floor/ wall mounted type distribution boards made out of reputed company IP 43 - #IK 09 with metal door having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISSandasperspecial conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.BDB ( 6way SPN DB)incoming 1 no of RCCB: 25A (100mA) 2Poutgoing 4 nos of 6-16A 10kA SP MCB \"C\" as per SLD |
| 340 | Fittings & FixturesInstallation and testing offollowing types of fluorescent tube fixtures directly on wall / ceiling of building with allaccessories such as electronics ballast, fluorescent tube lights, stove enamelled box, perpex sheet cover etc complete assembly including supply & fixing of teak wood round block and making connection from the suitable point outlet as per the direction of Engineer-in-charge. |
| 341 | Supply, delivery, installation, testing & commissioning of 10 watt or above Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs. (Make: Bajaj/ Philips/ Havells/ Wipro) |
| 342 | Supply, delivery, installation, testing & commissioning of 30w LED street light including GI pipe bracket, necessary wiring from loop-in-box with 1.5 sqmm copper wires inside PVC pipes etc complete as required with all materials as per direction of Engineer-in-charge.(Make: Bajaj/ Philips/ Crompton/ Havells/Wipro) |
| 343 | TRANSFORMER INSTALLATION WORKCable LayingSupply, laying & testing of following size of PVC insulated, PVC sheathed, round/strip armoured aluminium/cupper conductor power cable of 1100 volt grade clamped on surface ofwall/column/ existing RCC/ stone ware/ masonry cable trench/ cable trey/ through G.I. pipe/ hume pipe as the case may be, including cost of saddles/ clamps/ markers etc and cable end termination but excluding the cost of G. I. pipe/ hume pipecomplete with making good the damages caused and returning the balance unused cables to stores as required and as per direction of Engineer-in-charge. 3&1/2 core x 240 sqmm A2XFY |
| 344 | Cable termination: Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.3&1/2 core x 240 sqmm A2XFY |
| 345 | TRANSFORMER INSTALLATION WORKSupply & fixing CT meter sheet steel enclosures made out of 16 gauge CRCA sheet ,double door with lock, neopraene gasket all around, two numbers earth lugs including painting, padlock arrangement. Class 0.5 with O/P burden of 30VA |
| 346 | Supplying and erection of 150X 150 RS joist pole of 11m long. (30.6 kg /mtr). |
| 347 | Supply installation and commissioning of 200Amp 11kv on load isolated air brake switch with braking capacity of 10kA complete with following accessories. Knife blade switches both Male/Female. Operating GI pipe with handle & rotating mechanism. Pad locking arrangement with pad lock. Scope also includes interconnecting AB switch OH line with 30sqmm AAC conductor & interconnection to pin insulator/HG fuse set by suitable Cu flexible strip .Spring earth of the handle ,earthing of switch etc. |
| 348 | Supply installation and commissioning of 11kV home gap fuse set on the double pole structure. The 11KV HG fuse set to be complete with 11KV insulators Cu horn gaps etc. The scope also includes interconnecting the HG fuse with transformer with \"0\" SWG HDB Cu conductor. (11KV, 200Amp, 3Pole) |
| 349 | Supply installation and commissioning of 11KV lighting arrester including interconnection by 30sqmm AAC conductor & clamp(12KV, 5KA) |
| 350 | Supply and fixing of substation bracket inj complete set. With 100x50x6 mm for MS channel, 75x40x6mm MS channel for AB switch and HG fuse, 50x50x5mm MS angle for Transformer (140Kg) including painting. |
| 351 | Supply installation and commissioning of 11KV Disc Insulator 90 KN (B & S type) |
| 352 | Supply & fixing of11 KVDisc hard ware fittings (in pairs) |
| 353 | Supply installation and commissioning of HT Stay set with complete accesssories like Anchor rods, insulators, bow eye bolts and stay wires. Scope inclusive of supply of stay clamps. |
| 354 | Supply of materials and installation of pipe earth electrode made out of 40mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCCcover complete with labour for excavation of pitinall kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 355 | Supply of materials and installation of chemical earthing size of chemical earth bar 3 mtr, size of earth pit 3\" X 2\" X 9\" chemical compound to be used 50 kg. There is an arrangements forterminationofcopper strip of earth continuity conductor including cost of water pouring arrangements, brick masonary enclosure on top with removable cast iron cover complete with labour for excavation of pitinall kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 356 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required. |
| 357 | Supplying and laying 25 mm x 5mm G.I. strip on surface or in recess for connection etc as required. |
| 358 | Supply & fixing ofGInuts, bolts & washer of assoarted size for above work. |
| 359 | Supply installation and commissioning of 100 KVA, 11/0.4KV (Coper wonded) Transformer with tap changer, BIS Energy level-II with necessary hardware including unloading from truck, leading to the pole/plinth location and EMR test etc as required. |
| 360 | Supply & providing of 11K GI pin & pin insulators |
| 361 | Providing and binding with aluminium binding wire for all type binding for transformer installation work. |
| 362 | Supplying and painting with Aluminium Paint where ever required for transmission line. |
| 363 | Supplying and painting with Black paint where ever required for transmission line. |
| 364 | Supplying and painting with Redoxide paint where ever required for transmission line. |
| 365 | Supply installation and commissioning LT Distribution Panel Board for 100KVA Transformer with MCCB, Aluminium Busbar for two Bay with Kitkat Fuse. |
| 366 | Supply installation and commissioning LT Busing cover in the LT site of the transformer |
| 367 | Supply and construct with all material for Boundary wall for fencing and anti climbing with M.S. Gate 5\"-0\" x 8\"-0\".Sand & Gravel spreading over the entire area. |
| 368 | Supply and construct with all material for plinth of size 5\"-0\"x5\"-0\"x6\"-0\". |
| 369 | Supplying and erection of 150X 150 RS joist pole of 11m long. (30.6 kg /mtr). 2 nos |
| 370 | Supply & fixing of(100 x 50 x 6)mm M.S Channel |
| 371 | Supply & fixing of11 KV \"V\" cross arm. |
| 372 | Supply & fixing of 11 KV top chanel. |
| 373 | Supply & fixing of back clamp for cross arm |
| 374 | Supply & providing of 11K GI pin & pin insulators |
| 375 | Supply installation and commissioning of 11KV Disc Insulator 90 KN (B & S type) |
| 376 | Supply & fixing of11 KVDisc hard ware fittings (in pairs) |
| 377 | Supply installation and commissioning of HT Stay set with complete accesssories like Anchor rods, insulators, bow eye bolts and stay wires. Scope inclusive of supply of stay clamps. |
| 378 | Supply & installation of coil earthing |
| 379 | Supply & fixing ofassoarted nuts, bolts & washer for above work. |
| 380 | Providing and binding with aluminium binding wire for all type binding for transformer installation work. |
| 381 | Supply & stringing with 55mm² insulated AAA Conductor. |
| 382 | Supplying and painting with Aluminium Paint where ever required for transmission line. |
| 383 | Supplying and painting with Black paint where ever required for transmission line. |
| 384 | Supplying and painting with Redoxide paint where ever required for transmission line. |
| 385 | GradingSupply & fixing of(75 x 40 x 6)mm M.S Channel |
| 386 | Supply & fixing of No 8 G.I wire |
| 387 | Supply & fixing ofeye hook |
| 388 | SAFETY EQUIPMENT\"S & OTHER:Supply and hanging of Shock Treatment Chart duly Laminated. |
| 389 | Supply & Laying of 8 mm Thick Rubber Mat (1mtr x 2mtr), ISI mark of 1100 V Grade. |
| 390 | Supply and Installation of 4 Nos. Fire Buckets on a Mild Steel Stand complete as per specification and requirement of Fire Safety Provisions. |
| 391 | Supply and Installation of 4.5 Kgs. Capacity CO2 type Fire Extinguisher complete as required. |
| 392 | Providing and fixing bi-lingual Danger HT notice board of 250mmx200mm as specified below,made of mil;d steel at least 2mm thick & vitreous enamelled signal red color on both sides as background & with insprictions in enamelled vitreous white color on front side for lettering as required. |
| 393 | Supply of First Aid box with all required accessories. |
| 394 | Supply of 82.5 KVA, 415 Volts (3-phase) DG Set Stamford make alternator mounted on a common base , complete with:Fuel tankBatterry and leadsResidencial silencerAMF controll panelFirst fill of lube oil and colantAVM padsAcoustic Enclosure |
| 395 | Unloading, Shifting, Intallation & commissioning with civil foundation, 4 nos earthing, 6 core 2.5sqmm copper FRLS PVC controll cable, statutary (Electrical) approval, standard testing as per PCB rule. |
| 396 | Supplyinh and fixing of Exhaust extension of 150MM DIA MS Pipe with wall Support including Horizontal Support with MS Steel, SS Below, Thermal Insulation of 50MM Rockwool, Chicken mess, Aluminium Sheet and painting etc. |
| 397 | Supply, laying & testing of following size of PVC insulated, PVC sheathed, round/strip armoured aluminium/cupper conductor power cable of 1100 volt grade clamped on surface ofwall/column/ existing RCC/ stone ware/ masonry cable trench/ cable trey/ through G.I. pipe/ hume pipe as the case may be, including cost of saddles/ clamps/ markers etc and cable end termination but excluding the cost of G. I. pipe/ hume pipecomplete with making good the damages caused and returning the balance unused cables to stores as required and as per direction of Engineer-in-charge. |
| 398 | 3&1/2 core x 150 sqmm A2XFY |
| 399 | 3&1/2 core x 70 sqmm A2XFY |
| 400 | 3&1/2 core x 35 sqmm A2XFY |
| 401 | 3&1/2 core x 25 sqmm A2XFY |
| 402 | 4 core x 25 sqmm A2XFY |
| 403 | 4 core x 16 sqmm A2XFY |
| 404 | 4 core x 10 sqmm A2XWY |
| 405 | 3 core x 6 sqmm A2XWY |
| 406 | 2 core x 4 sqmm A2XWY |
| 407 | 2 core 2.5 sqmm flexible coper cable |
| 408 | Cable termination: Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
| 409 | 3&1/2 core x 240 sqmm A2XFY |
| 410 | 3&1/2 core x 150 sqmm A2XFY |
| 411 | 3&1/2 core x 70 sqmm A2XFY |
| 412 | 3&1/2 core x 35 sqmm A2XFY |
| 413 | 3&1/2 core x 25 sqmm A2XFY |
| 414 | 4 core x 25 sqmm A2XFY |
| 415 | 4 core x 16 sqmm A2XFY |
| 416 | 4 core x 10 sqmm A2XWY |
| 417 | L.T. PANELS :Supply Receiving, storing, transportation to exact location, loading, unloading, handling, hoisting, installation including jointing of panels shipping section & bus bar fish plates, checking of all interconnections, small wiring, testing & commissioning of the following cubical type panels made of 2.0 CRCA structure, base channe lSMC, doors & sheet metal partitions complete with, Air Circuit Breaker, moulded case circuit breakers, meters, indicating lamps, current transformer etc. Complete in all respects, insulated bus bars with heat shrinkable PVC sleeve, supported on FRP / SMC supports in suitable bus chambers, interconnection, small wiring, name plate, danger plate, earth bus etc. & comprising of compartments ( minimum form 3b type -1 construction)with hinged door for each feeder & its accessories, cable alley with hinged doors, bus chamber with bolted door etc. The panel being of dust & vermin proof construction with long lasting synthetic rubber gasket, attractively powder coated with light grey Paint shade as approved by consultant and having orange peel finish. The panel shall be free standing type / wall mounted type as per relavant drawing and comprising with the following:Note:-1) Rated Short time withstand current of all ACB\"s are Icw for one second.Ics = Icw for 1.0 Sec for all ACBs2) Breaking Capacity of all MCCB\"s are Ics Service Breaking Capacity.Contd. next row |
| 418 | 3) MCCB\"s upto 250Ashall be with Adjustable thermal-magnetic and above 250A Microprocessor based Adjustable release. All MCCBs for Incomersshall have O/C, S/C and E/F protection and forOutgoing feeders of all panels shall be with O/C and S/C protection.4) The Earth fault protection for MCCBs upto 250A shall be provided with external E/F module and above 250A rating it shall be in built with MCCB\"s Micro Processor release.5) All MCCB\"s shall be with Extended type Front door operating handle, Phase Spreaders & Phase Barriers.6) TPN MCCB Shall mean 3 Pole MCCB with Adequate size of separate neutral link.7) MCCB above 63A should be provided with copper spreader terminals.8) All MCB shall be C -Curve and of 10 KA breaking capacity.9) The Current Transformers burden shall be 5VA upto 250A & 15 VA above 250A, accuracy class 1.0 for metering and class 5P10 for protection.10) CTs shall be \"CAST RESIN\"type.11) All indication lights shall be LED type.12) All meters shall be \"DIGITAL\" type with RS485 Port except ammeter & voltmeter.13) Panel space heaters with control MCB & Thermostat, covered LED lamp controlled by door switch for each panel bay.14) Gland plates shall be 3.0mm thick CRCA sheet for Multi core cable.Contd. next row |
| 419 | 15) Capacitor Banks shall be Heavy Duty type equal to MPP- HDand 7% detuned reactor shall be copper wound only.16) \"ON\" Indicating lamp shallbe provided for all 3 phase MCCBout going feeders unless otherwise specified.17) Control SP MCB\"s of 6A Rating shall be provided for each metering circuit/control circuit.18) The operating height shall be limited to 300mm minimum and 1800mm maximum.19) Degree of Protection for Indoor panels shall be IP:52& For Outdoor Panel IP:55, Double Door with Canopy.20) The maximum temperature rise at any point on bus bar and the joints shall not be more than 40°C over an ambient of 45° C.21) Current density of Busbar shall be calculated based on temp rise, short circuit & other calculation factor, for 600A & below ratings, Current density of aluminium shall be minimum 0.8 Ampsper sqmm for rated current of bus bars and current density of copper shall be min 1.60 Amps per sqmm for rated current of bus bars.22) Panel manufacturer should have Type Test Certificates for short Time withstand current test of 50kA for 1.0 Sec, D.O.P and temperature rise on similar panels, from CPRI Bhopal/Bangalore.Contd. next row |
| 420 | 23) Panel stand shall be provided for wall mounted panel/MDB\"s including powder coated sheet on all three sides.MAIN LT PANEL (MLTP)INCOMING 2 Nos. 250A, TPNMCCB (50kA) + 2Nos. 250A, 4P Contactor with built in Microprocessor based release for Over load, Short circuit &Earth Fault protection. For Transformer & DG\"s Set.MAIN BUS BAR One sets of 250 ATPN Alu. Bus Bar, 50KA, TPN ALU. Bus Bar with PVC Sleeve in sealedBusChamber. CONTROL BUS BAROne set of 24V DC supply DP Al. bus bar with PVC sleeve in sealed Bus Chamber (power pack of sutable capacity shall be included in panel).METERING ,INDICATIONS AND RELAYS :Transformer Incomer1 Set. of R/ Y/ B phase indicating lamp with control MCB\"s.1 Set of ON/OFF/TRIP Indicating lamps with control MCB,s.1 No. (0 - 250A) digital ammeter with built in selector switch with CT\"s 1 No.(0 - 415 V) Digital Voltmeter with built-in Selector switch & control MCB\"s.1 no. Multi Function Meter (V, A, PF, THD, F, W, WH, VA, VAH, VAR, VARH, RUN Hrs, ON Hrs Interrupts, Max. Demand Indicator)with RS485 ( EM 7230/ Eqv.) with control MCB.(Trip Transformer supply, wiring & Contd. next row |
| 421 | Auxiliery relay shall be provided.)1 no. Reverse Power Relay with C.T.&MCB1 Set of 3 Phase Under & Over Voltage Relay with time delay setting of upto 5 minutes, including control MCBs.1 Set of metering CT\"s of suitable ratio for 1No. APFC Relay for Capacitor control panel1 Set of Surge Suppressor, type B+C with suitable back up Protection.1 Set control MCBs.D. G.Incomers1 Sets. of R/ Y/ B phase indicating lamp with control MCB\"s.1 Set of ON/OFF Indicating lamps with control MCB,s.1 nos. (0 -400A) digital ammeter with built in selector switch with CT\"s 1 nos.(0 - 500 V) Digital Voltmeter with built-in Selector switch & control MCB\"s.1 no. Multi Function Meter (VAF+ PF + Power & Energy Meter) with RS485 (EM 6436/ Eqv.) with control MCB1 nos. Microprocessor Based Reverse Power Relay with C.T.&MCB1 Sets control MCBs.OUTGOINGS:2 Nos. 160A TPN MCCB(36KA) with in built M.P. Rel.For O/C & S/C Prot.2 Nos. 100A TPN MCCB(36KA) with in built M.P. Rel.For O/C & S/C Prot.Contd. next row |
| 422 | 3 Nos. 800A TPN MCCB(36KA) with in built M.P. Rel.For O/C & S/C Prot.2 Nos. 63A TPN MCCB(36KA) with in built M.P. Rel.For O/C & S/C Prot.Out going MCCB feeders9 Sets of ON/OFF Indicating lamps .7 SetsMulti Function meters with Amps, KWH KW of suitable ratings for Outgoing Feeders.(EM 6433/Eqv.)2 SetAmmeters , CTR - 5A, 230Vac, with Iin buillt selector switch forOutgoing Feeders AMF LOGIC, START / STOP AND ELECTRICAL & MECHANICAL INTERLOCKING.Electrical & Mechanical interlocking between 1 No. DG supplies, 1 No. Main supply, so that when Main supply trips then DG should start automatically and vise-versa when main supply healthy, Then DG Set stop automatically. System should beincluding AMF Relay / AMF Logic as required.Any additional component require for proper operation of AMF System shall be considered by panel manufacturer without any additional cost.BATTERY CHARGER:- (ForDG Sets)1 Set 24V / 12V DC Battery charger having proterction of over Voltage / Under voltage / Over charging. Battery charger shall be comptele with DC ammeter , DC Voltmeter & LED indicating lamps as required.1 No. 50 x 6 mm AI earth bus across the width of MLTP. |
| 423 | CAPACITOR CONTROL PANEL (CCP)20 KVARINCOMING :1 no. 80A, TPNMCCB (25kA)with Thermal Magnatic based release for Over Current, Short circuit protection + Earth Fault module.BUS BAR :One set of 100 A TPN Alu. Bus Bar, 25kA with PVC Sleeve in sealed Powder Coated BusChamber. METERING, INDICATION AND RELAY :1 nos. (0 -160A) digital ammeter with built in selector switch with CT\"s 1 set Automatic Power Factor Correction Relay (8 Steps)with digital Power Factor MeterOne set of R/Y/B phase indication Lamp with control MCBs. 1 Sets of \"ON/OFF1 No. Auto / Manual Selector Switch1 set of Aux. Contactors1 No. timer for manual mode switching1 set Control MCBOUTGOING :1 Sets of 10 KVAR Capacitor bank with 7% Harmonic Block Reactor, 32A TP contactor and 32 TP MCCB (25kA)Capacitor rating to be designed for required output KVAR at 415V.1 Set of 5 KVAR Capacitor bank with 7% Harmonic Block Reactor, 16A TP contactor and 16 A TP MCB \"D curve\" (10kA) Capacitor rating to be designed for required output KVAR at 415V.Contd. next row |
| 424 | 2 Set of 2.5 KVAR Capacitor bank with 7% Harmonic Block Reactor, 10A TP contactor and 10 A TP MCB \"D curve\" (10kA) Capacitor rating to be designed for required output KVAR at 415V.7 Sets \"ON/ OFF\" LED Indicating lamps.7 Sets \"ON/ OFF\" Push Buttons.7 Sets Control MCBs & Neutral links.7 Sets of Digital Ammeter with built-in selector switch & 3CT\"s.Panel space heaters with control MCB & Thermostat, covered LED lamp controlled by door switch for each panel.Contd. next row |
| 425 | Suitable Size of Exhaust fans with Air filter for each Panel of Capacitor & Reactor compartment. 50 x 6 mm AL. earth bus across the width of panel |
| 426 | UTILITY PANELINCOMING :1 No. 100A, TPNMCCB(25KA) with Thermal Magnatic based release for Over Current, Short circuit protection + Earth Fault module.BUS BAR :One set of 100 A TPN Alu. Bus Bar,25kA with PVC Sleeve in sealed Powder Coated BusChamber. METERING AND INDICATION :1 No. digital Multi Function Meter ( Amps, KWH, KW) and CT\"s& control MCB\"s (Eqv. To EM6433)1 set of R/Y/B phase indication Lamp with control MCBs. 1 Set of ON/OFF Indicating lamps .OUTGOING :1 No. 63A TPN MCCB (25KA)2 Nos. 40A TPN MCCB(25KA)1 No. 25A TPN MCCB(25KA)3 No. 40A FP MCB (10KA)-C-curve6 Nos. 32A FP MCB (10KA)-C-curve 1 No. 25A FP MCB (10KA)-C-curve |
| 427 | OUTGOING METERING & INDICATION : 4 Sets of\"ON \"LED Indicating lamp with control circuit 25 x 6 mm AL. earth bus across the width of panel |
| 428 | VTPNDB FOR SOCKETSINCOMING :1 No.63A,TPN MCCB(25KA) with Thermal Magnatic based release for Over load, Short circuit protection + Earth Fault module.BUS BAR :One set of 100A TPN Alu. Bus Bar, 25kA with PVC Sleeve in sealed bus chamber.METERING AND INDICATION :One set of R/Y/B phase indication Lamp with control MCBs. 1 Set of ON/OFF Indicating lamps .OUTGOING :7 Nos.32A FP MCB(10KA)25 x 6 mm AL. earth bus across the width of panel |
| 429 | EXTERNAL LIGHTING FEEDER PILLER OUTDOOR TYPEINCOMING :1 No. 32A, FP MCB(10KA)-C-Curve1 No. 32A, FP Power ContactorBUS BAR :One set of 40A TPN CU Bus Bar, 25kA with PVC Sleeve in sealed bus chamber.METERING AND INDICATIONS1 set of R/Y/B phase indication Lamp & MCB. Electronic Timer (for 24 hours)Auto / manual SwitchPush button (ON / OFF)OUTGOING :13 Nos.20A DP MCB(10KA)-C-Curve2 Nos. 20 A 4P MCB (10kA)without Timer Bus-Bar25 x 6 mm AL. earth bus across the width of panel |
| 430 | METAL CLAD SOCKETSSupply, installation, testing & commissioning of 3Pin 20A single phase Metal Clad socket with 20A DP MCB, in suitable MS box, plug top with chainas required. |
| 431 | Supply, installation, testing & commissioning of 5 Pin 32A three phase Metal Clad socket and 32A 4P MCB, in suitable MS box, plug top with chain & earth pin as required For workshop & washing area(wiring shall be paid extra) |
| 432 | FLAME-PROOF MOULDED SOCKETSSupply, installation, testing & commissioning of Flame-proof 32A three phase moulded socket (IP44) with 32 A 4P Isolator in Flame-proof suitable box (wiring shall be paid extra) |
| 433 | Supply, installation, testing & commissioning of Flame-proof 100A three phase moulded socket (IP44) with 100A 4P Isolator in Flame-proof suitable box (wiring shall be paid extra) |
| 434 | MOULDED SOCKETSSupply, installation, testing & commissioning of 5 Pin 63A three phase Moulded socket (IP65) with 63A 4P Isolator, in suitable MS box, plug top with chain & earth pin as required For workshop & washing area(wiring shall be paid extra) |
| 435 | TAPES/WIRESSupplying, receiving, laying, fixing, jointing, and terminating of the following tapes / wires in masonry treches / on walls / on cable tray / along the cable with suitable G.I. / Copper Clamps, screws etc. The wire shall be terminated with proper sockets, washers, bolts & nuts.All joints shall be rigid using double rivites : |
| 436 | 25 x 6 mm CU Tape with PVC sleeve |
| 437 | 25 x 6 mm GI Tape |
| 438 | 25 x 3 mm GI Tape |
| 439 | 10 sq. mm Cu. Flex. Cable wiring (PVC Insulated) (For UPS) |
| 440 | 6 sq. mm Cu. Flex. Cable wiring (PVC Insulated) (For Server / EPABX & for PDB\"s / Utilities) |
| 441 | 4 sq. mm Cu. Flex. Cable wiring (PVC Insulated) |
| 442 | 2.5 sq. mm Cu. Flex. Cable wiring (PVC Insulated) |
| 443 | 1.5 sq. mm Cu. Flex. Cable wiring (PVC Insulated) |
| 444 | 8 SWG GI wire |
| 445 | EARTH STATIONS:Providing and fix following earth station as per IS 3043-1987, with watering pipe, GI funnels masonry chamber with CI cover(heavy duty), Including excavation and refilling of pit, supplying and fixing ofcharcoal salt & sand, identification of pit as per required. (Qnty. of salt- 60Kg. & qnty. of charcoal- 100Kg.) Note :-earth station chamber size 450 x450 mm & 40 mm dia GI pipe shall be used for watering |
| 446 | 600 x 600 x 6.3 mm GI Plate Earth Station with 2Nos of 40x6mm GI Earth Strip upto earth station chamber. |
| 447 | 80 mm dia& 6.0 M long G.I. Pipe Earth Station with 2Nos of 40x6mm GI Earth Strip upto earth station chamber.(for Machines, Plant Grid Earthing& Main LT panels room grid earthing) |
| 448 | MAINTENANCE FREE EARTHINGSupply, Installation, Testing & Commissioning of long life Maintenance Free Electrolytic Earthing System with 20 year service warranty (UL listed). The Electrode shall be of flat inside pipe technology with 3.0M Long, 2 Nos of 32 x 4 mmCopper flat in 60mm dia & minimum 4.0 mmwall thickness GI Pipe, which does not require manual addition of water. The system should be with 60 kg environment friendly mineral filling compound for lowering resistance. The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement. The earth electroded shoud have CPRI approval & capable of bearing fault current of 35kA.(for 2Nos. UPS & server). |
| 449 | HIGH MAST SYSTEM20M.High Mast SystemSupply,Installation,Testing,Commissioning of 20 M High Mast shaft shall be in two sections. Hot dip galvanised, inside and outside in single dip, suitable for wind Velocity as per IS 875 (part III). There shall be only one longitudinal seam weld per section and no circumferential weld. It shall also include accessories for high mast including head frame, 2-point suspension system with steel wire rope 6mm dia (7/ 19 construction) double drum winch, Galvanised Lantern carriage arrangement suitable for 8 to 12 luminaires symmetrically & its control gear boxes and lightning finial. The mast shall have an internal type power tool mounted at the base compartment for its operation. High Mast shall be comprising with the following.Height of mast - 20 MeterNo. of sections-TwoMaterial construction - S 355 grade as per BS-EN10 025 Base dia. and top diameter (A/F) Top : 150 mm, Bottom : 410 mmPlate thickness- Top : 3 mm, Bottom : 4 mm, Cross section of Mast- 20 side polygon.Standard for of galvanisation- As per BS EN ISO 1461Size of opening and door at base- 1200 x 250 mmDiameter of base plate- 570 mm Thickness of base plate- 25 mm Contd. next row |
| 450 | Lightning protection finial- G.I single spike Max.wind speed- 50m/s as per IS : 875 (Part - III)Number of foundation bolts-08 nos. PCD of foundation bolts-490 mmType / diameter / length of foundation bolts-TS 600 / 30 mm dia / 850 mm longLUMINAIRES CARRIAGEMaterial of construction-50 NB ERW Class B - M. S. PipeDiameter of carriage ring (mm)-535 mm (ID) Construction-6 Arm, Welded, 2 sectionsLoad carrying capacity-12 Luminaire TRAILING CABLEConductor-Copper,5 core, 4 sq mmInsulation-EPR insulated, PCP sheathedNo. of circuits per mast-One no cable per mastWINCH / POWER TOOLType / SWL of winch-Double drum, SWL 750 KgMethod of operation-Integral MotorMotor capacity-1 HPNo of speeds-6 Pole, Single speedSTAINLESS STEEL WIRE ROPEGrade / construction-AISI 316, 7/19 constructionNumber of ropes-Two continuousDiameter (mm)-6 mmBreaking load capacity-2350 kg x 2Foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates.Fixing with 12 No. floodlight luminaires of BAJAJ make cat No.BJFL 350W LED light fixture.Contd. next row |
| 451 | 1 Set LED based aviation obstruction light.Control panel housing suitable to control the high mast. It shall also have suitable controls for operation of Power Tool. Incomer of the control panel with 1 No. 32A 4P MCB (10kA) & outgoing with 12 Nos 10A/20A SPMCB and 1 No. 20A TP MCB(10kA)Construction of suitable shallow foundation of 1100 mm x 1100mm x 1500mm (L x W x D) with 1:2:4 concrete for the high mast considering the safe soil bearing capacity atsite as 10 T / sq. mtr. (considering the back filled soil) at 2 mt depth with all materials & labour.*Contractor shall approvel the foundation before castingErection of the high mast with the help of suitable equipment and wiring of luminaries with all wiring material & labour (4.0 sq. mm. Cu. Wiring to each Flood light) 2 Set of Earthing for High mast with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal and salt as required. Including connection of High mast earth terminal with 6SWG GI earth wire including all material & labour.Control Panel on suitable foundation including all material & labour.Note: Contractor shall submit the design of foundation structural detail and get the approval from consultant/ project incharge before starting the work considering the back filled soil. |
| 452 | Supply, receiving, storing, handling, laying, testing & commissioning of45W LED Post Top BAJAJ BGCT W4 (2600 Lumen, THD<10%) for Gate light on 40 mm. dia & 0.6 M long GI pipe (minimum midium class, ISI marked ) |
| 453 | Design, supply, installation, testing & commissioning on Grid connected roof top solar PV (photo voltaic) power plant which includes Solar PV Modules, Inverters, MMS suitable for 180 kM wind speed, AC DB, DC DB, Lighting arrestor, earthing, cabling and Net metering. The scope also includes maintenance & PV module cleaning for a period of 5 years. |
| 454 | Supply, installation and commissioning of 8 mm aluminum round conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , RD 8 ALU. Included Cross connector and Expansion piece.Supply, installation and commissioning of roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance177 30 M8.Supply, installation and commissioning of polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. 165 MBG-8-10 (5218700 ) |
| 455 | Supply, installation and commissioning of vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod : Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) 3Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. OBO Type No. 101 VL3000 ( 5401 98 9 ). Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. OBO Type No. F-FIX 16 ( 5403 20 0 ). Fang fix clamp made of SS, lightning tested for 100 KA 10/350 micro sec waveform. 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors.Concrete, frost-resistant, can be stacked.OBO Type No. F-FIX S16 ( 5403 22 7 ) |
| 456 | Supply, installation and commissioning of 10 mm dia solid, round conductor with 250 micron copper coating for using as Air-terminal and structural down conductors in case of structurally utilized concrete columns especially for highly corrosive areas, (i.e., projects / building near sea-shore). The conductors being copper coated can be connected with all accessories such as Cu (Copper), and SS (Stainless steel). |
| 457 | Supply, installation and commissioning of UL Listed & CPRI tested maintenance free, Low carbon copper coated earth rod of 3 metre electrode having diameter of 25 mm with copper coating thickness of 250micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing compound shall be of 50 kg/pit tested as per IEC 62561-7, TCLP tested. The above arrangements shall be provided with heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system. |
| 458 | Supply and installation of 2 Way SIP Speaker with HD acoustic chamber, Features SIP paging, multicast paging, callwaiting with priority override ntegrated dual-band 802.11 a/b/g/n WiFi and Bluetooth. One 10/100Mbps network port with PoE/ PoE+. Make: Grandstream/Cyberdata |
| 459 | Supply and installation of SIP Paging Server with bell scheduler enables users, through a single SIP extension, to access up to 100 zones for paging and bell scheduling for your VoIP phone system. Make: Cyberdata or equivalent |
| 460 | IP Surveillance SystemSupply, installation and commissioning of Indoor Dome IR Network Camera (1/2.7\" CMOS sensor, Mini. Pixel of 2560*1920 or higher video quality, frame rate of Up To 25fps @ 4MP, H.265, H.264 & MJPEg video compression, 2.8mm Fixed lens, physical ICR filter of both day and night, 30mtr IR Distance,120dB WDR ,3Streams Supported, WDR , 3D-DNR for noise reduction, BLC, ICR, EXIR, Audio In and Out, Alam in and Out. IPv4/IPv6 network supported, IP67, IK10 rated for weatherproofing, ONVIF ver 2.2 or higher, PoE IEEE 802. 3af (UL, FCC, CE, BIS certified.) with accessories as require. Make- Honeywell/UNV/Milesight |
| 461 | Supply, installation and commissioning of Indoor Bullet IR Network Camera (1/2.7\" CMOS sensor, Mini. Pixel of 2560*1920 or higher video quality, frame rate of Up To 25fps @ 4MP, H.265, H.264 & MJPEg video compression, 2.8mm Fixed lens, physical ICR filter of both day and night, 30mtr IR Distance,120dB WDR ,3Streams Supported, WDR , 3D-DNR for noise reduction, BLC, ICR, EXIR, Audio In and Out, Alam in and Out. IPv4/IPv6 network supported, IP67, IK10 rated for weatherproofing, ONVIF ver 2.2 or higher, PoE IEEE 802. 3af (UL, FCC, CE, BIS certified.) with accessories as require. Make- Honeywell/UNV/Milesight |
| 462 | Supply and Installation of outdoorIP PTZNetwork Camera1/2.9\" CMOS, ICR, 1920x1080:30fps, Ultra 265/H.264/MJPEG, Triple streams, DC12V, Micro SD card slot up to 256gb,-40-65 °C, IP66, 22x optical zoom(5.2~ 114.4mm), IR range: up to 150m, IR anti-reflection window IP66 rated for weather proofing, ONVIF, POE IEEE 802.3af (UL, FCC, CE, BIS certified). Make- Honeywell/UNV/Milesight |
| 463 | Supply and Installation of 32 CH NVR Support 12MP/8MP / 5MP / 4MP / 3MP / 1080P / 960P IP Adopt standard H.265 high profile compression format, With 4k Video Output, Compression Standard H.265, Network Access Bandwidth 320Mbps, HDD SATA × 8(Upto 10TB Supported), 1- e-SATA And 2-way Audio RCA × 1, Local Output RCA × 1, USB 2.0 × 2 (one in the front panel and the other in the rear panel), USB 3.0 × 1 (rear panel) (UL, FCC, CE, BIS certified). Make- Honeywell/UNV/Milesight32TB (4TBx8nos) Storage Capacity. Make: Seagate/ WD. |
| 464 | Supply and laying of 4 pair Cat6 U/UTP Cablein the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance = 9.38 O/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 O @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco / Legrand / Panduit |
| 465 | SITC of 24port IEEE 802.3af/at PoE 10/100/1000Mbps Managed Switch with Two Combo ports and minimum PoE power budget of 370W, Support IPv6 management, CLI/ WEB/ SNMP Management including 3years product warranty. Make: Cisco/ HP/ Juniper |
| 466 | Supply & fixing of 6U/500D UL Listed wall mount Rack loaded with one no 6Skt 5AMPpower distribution unit,1no Cable manager, Two nos 90CFM FANs and one pkt H/W screw. Make: APW/ Valrack/ Rittal |
| 467 | SITC of 24port IEEE 802.3af/at PoE 10/100/1000Mbps Managed Switch with Two Combo ports and minimum PoE power budget of 195W, Support IPv6 management, CLI/ WEB/ SNMP Management including 3years product warranty. Make: Cisco/ HP/ Juniper |
| 468 | Supply and installation of Cat 6, 24-portloaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Tyco / Legrand / Panduit |
| 469 | Supply and installation of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to theStandard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion ,RJ45, 8P8C, 2 FORK 50µ’’ Gold Plated Contacts ,100% Factory Tested ,Transparent Boot Cable Assemblies. Make: Tyco / Legrand / Panduit 1mtr Lenghth |
| 470 | Supply and installation of Cat6A UTP Industrial Plug for Camera Connectivity. Make: Tyco/Digisol/R&M |
| 471 | SITC of 55\" UHD (3,840 x 2,160) TV with 300 nits brightness,10W+10W Audio Output,Crestron Connected®,NTP sync timer, BEACON, Embedded CM (contents manager), Soft AP, WiFi , Screen Share (Miracast), DIAL, Bluetooth Audio Playback,Hotel Mode , Welcome Screen (Splash Image), Insert Image, One Channel Map, IP Channel Manager, External Speaker Out , Remote jack pack, Moving Picture Playback, Auto Off / Sleep Timer,Smart Energy Saving, Motion Eye Care,USB Cloning, WOL, Interface : Set Side - HDMI In 3, USB 1, CI Slot, RF In, Digital Audio Out (Optical), RS-232C, RJ45 , External Speaker Out,Power Consumption(Typ.)-145 W, with 3years Warranty. Make: Samsung/ LG /SONY |
| 472 | Supply and laying of 4 pair Cat6 U/UTP Cablein the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance = 9.38 O/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 O @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco / Legrand / Panduit |
| 473 | Supply and laying of following size rigid PVC conduit pipe (medium ) through floor / wall / partition with GI spacer clamps or as directd.Rate to include for accessories - bends,sockets T\"s etc. |
| 474 | 19 mm dia. |
| 475 | 25 mm dia. |
| 476 | 32 mm dia. |
| 477 | ONLINE UPSSupply, instllation, testing and commissioning of 10KVA Online UPS with unity out put per factor 95% overal effecency suitable to work 0-50digree centegrate ambient temprature including SMF back of 30minutes with all require accessories . Make: Emerson/APC/Numeric |
| 478 | Air Conditioning |