Repair And Renovation For Govt. Accommodations Allotted In Qtr. No. H-23, Type - I, Ps Lajpat Nagar, New Delhi., Delhi-Delhi

Department Of Housing Management has published Repair And Renovation For Govt. Accommodations Allotted In Qtr. No. H-23, Type - I, Ps Lajpat Nagar, New Delhi.. Submission Date for this Tender is 06-09-2022. Building Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

33754694
Repair And Renovation For Govt. Accommodations Allotted In Qtr. No. H-23, Type - I, Ps Lajpat Nagar, New Delhi.
Open Tender
Indian
Delhi
Delhi
06-09-2022

Tender Details

Repair And Renovation For Govt. Accommodations Allotted In Qtr. No. H-23, Type - I, Ps Lajpat Nagar, New Delhi.

Key Value

Document Fees
Refer document
EMD
INR 8954.0 /-
Tender Value
INR 4.47 Lakhs /-

BOQ Items

Name of Work: Repair and renovation for Govt. accommodations allotted in Qtr. No. H-23, Type - I, PSLajpat Nagar, New Delhi
Sl. No. Item Description
1Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
21:5:10 (1 cement : 5 coarse sand (zone-III) : 10 graded stone aggregate 40 mm nominal size).
3Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
4Centering and shuttering including strutting, propping etc. and removal of form for
5Suspended floors, roofs, landings, balconies and access platform
6Shelves (Cast in situ)
7Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
8Thermo-Mechanically Treated bars of grade Fe-500D or more
9Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
10Cement mortar 1:6 (1 cement : 6 coarse sand)
11Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
12Cement mortar 1:3 (1 cement :3 coarse sand)
13Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
14Granite stone slab colour black, Cherry/Ruby red
15Area of slab upto 0.50 sqm
16Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
17Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
18Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
19Kiln seasoned and chemically treated hollock wood
2035 mm thick
21Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
2235 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
23Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
24150x10 mm
25100x10 mm
26Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
27125 mm
28100 mm
29Providing and fixing to existing door frames.
3030 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
31Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge
32Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
33Size of Tile 600x600 mm
34Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
35110 mm diameter
36Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
37Bend 87.5°
38110 mm bend
3912 mm cement plaster of mix :
401:4 (1 cement: 4 fine sand)
41Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification.
42Two or more coats on new work
43Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
44Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
45Two or more coats on new work
46Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
47Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
48Of area 3 sq. metres and below
49Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
50For thickness of tiles 10 mm to 25 mm
51Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
52Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
53Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
54Kitchen sink with drain board
55610x510 mm bowl depth 200 m
56Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
57Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
5820 mm nominal dia Pipes
59Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
6025 mm nominal dia Pipes
61Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
62Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
6315 mm nominal bore
64Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
6515 mm nominal bore
66Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
6715 mm nominal bor
68Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
6915mm nominal bore
70Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
71Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
72Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
73Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
74Size of Tile 600x600 mm
75Finishing walls with Acrylic Smooth exterior paint of required shade :
76New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
77Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
78600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
79Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
80Group A
81Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
82Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
83Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
84Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
85(i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
86(ii)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
87Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
88i) 3 x 1.5 sq. mm
89ii) 3 x 4 sq. mm
90iii) 3 X 6 sq. mm
91Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
92(i) 20 mm
93Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
94Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
95Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
96Supplying and fixing call bell/buzzer suitable for DC/AC single phase 230 volts, complete as required as per the direction of engg -in- charges.
97Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.
98Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
99Supply, installation, testing and commissioning of 1200 mm (nominal size), 30 watt / 36 watt LED batten luminaire in aluminium housing with minimum light output 100 lumen/watt complete with all accessories, electronic driver,diffuser, directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. ( Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar )
100Supply, installation, testing and commissioning of 12 Watt /15 Watt surface mountedLED downlighter luminairecomplete with all accessories and electronic driver, directly on ceiling / wall, including connections etc. as required. Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar)
101Supply, installation, testing and commissioning ofwallmounted light fixture complete with B22 base, diffuser and15 watt LED blub etc as requireddirectly onwall, including connections etc. as required. (Approved Makes:- Havells City 3 Wall light /orequivalent model Philips / Wipro/ Crompton /Jaquar)
102Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required.
1036 Module
104Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
10510 Amp Modular switch
10620 Amp Modular switch
1073 pin 10 Amp socket outlet
1086 pin 20/25 Amp Socket outlet
109Supplying and fixing PolycarbonateBattan/Angle holder with 8/10 watt LED bulbincluding connection etc. as required.
110Supply, installation, testing and commissioning of 10 watt LED bulkhead fittings with IP 66 ingress protection complete with all accessories and electronic driver, etc as requireddirectly onwall, including connections etc. as required.Makes : Philips / CG/ Havells/ Wipro/ Crompton/Jaquar )
111Supply, installation, testing and commissioning of 300 mm (nominal size) 9/10 watt LED batten luminaire with minimum light output 100 lumen/watt complete with all accessories, electronic driver,diffuser, directly on ceiling/ wall, including connectionsetc. as required. ( Approved Makes :- Wipro Garnet 10W LED Batten or equivalent model of Havells/ Crompton / Philpis / GE)
112Supplying, Installation, testing and commissioning ofBEE 5 star rated, 1200 mm sweepceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Makes :- Crompton /Havell"s / Usha / Orient )
113Supplying and installation of 300 mm sweep, 1400 RPM heavy dutyexhaust fan complete with louvers/shutters in the existing opening, including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required.(Havells makeISI markHeavy Duty Exhaust Fan or with similar specifications Crompton/Havells / Orient / Usha / Almonard)
114Supplying, installation, testing and commissioning of 30 W LED based Flood light luminaire,housing made up of pressure die cast aluminium / aluminium alloy, complete withdriver, cover andmountingbracket etc including installation directly onwall andconnection with 3 X1.5 sq.mm FRLS PVC insulated copper wire etc as required. The fixture should have a minimum system efficacy of 100 lumen/Watt, ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 and THD<20%. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance.LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Approved Make: Phillips MODEL NO.BVP120 LED 35 CW FG S1 PSU GR OR similar in Schreder/ Lighting Science / GE/ Philips/ Jaquar )
115Supplying and installation of fresh air fanwith louver shutter 250 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required. (Havells make Ventil Air-DX with self opening louvers or with similar specifications CG / Orient / Usha / Almonard/Havells )
116Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
11712 way , Double door
118Supplying and fixing 5 amps to 32 amps, 240 Volts "C" series MCB"s suitable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc as reqd. .
119a) Single Pole
120b) Double Pole
121Dismentling of old surface / recessed wiring and distribution board of 01 no Type - III qtr and making the damage good etc as required as per direction of engg.-in-charge.
122Less for cost of dismental material retrieve from the Qtr/ buildings which will be kept by the contractor i.c Cu/Al conductor PVC insulated wire, switch box, PVC/MS conduit pipe, accessories, Old fans and other electrical fitments etc complete as reqd.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail