Street Light Supply Work In Ward No 1 To 30 Street Light Supply Work In Ward No 31 To 60 , Based On Ruidp 2022 , Providing & Fixing Of Ik07 Ip 66 Protected Led Street Light Luminaire On Existing Bracket / Pole. Fixture Made Of Powder Coated Single Piece, madhopur-Rajasthan

Department Of Local Bodies has published Street Light Supply Work In Ward No 1 To 30 Street Light Supply Work In Ward No 31 To 60 , Based On Ruidp 2022 , Providing & Fixing Of Ik07 Ip 66 Protected Led Street Light Luminaire On Existing Bracket / Pole. Fixture Made Of Powder Coated Single Piece. Submission Date for this Tender is 14-09-2022. Coats and Jackets Tenders in madhopur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

33754183
Street Light Supply Work In Ward No 1 To 30 Street Light Supply Work In Ward No 31 To 60 , Based On Ruidp 2022 , Providing & Fixing Of Ik07 Ip 66 Protected Led Street Light Luminaire On Existing Bracket / Pole. Fixture Made Of Powder Coated Single Piece
Open Tender
Indian
Rajasthan
madhopur
14-09-2022

Tender Details

Street Light Supply Work In Ward No 1 To 30 Street Light Supply Work In Ward No 31 To 60 , Based On Ruidp 2022 , Providing & Fixing Of Ik07 Ip 66 Protected Led Street Light Luminaire On Existing Bracket / Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Lm6 / Adc12 Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc / Toughened Glass Cover ( Uv Stablzation Report Submitted For Uv Cover ) And Secondary Lens On Each Led & Should Be Smd Type . The System Level Luminaire Efficacy >=120 Lm / Wt With High Power Leds Is To Be Used And Potted Driver Must Be Potted & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Input Frequency 50Hz±3% Power Factor >0.95 Driver Efficiency >85% , Thd ( I ) <10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current <1000Ma Shown In Lm79 Report. The Luminaire Shall Be Bis Certified And T.C. Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Color Rendering Index >70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark / Name Engraved / Embossing On Die Cast Housing To Allow Traceability / Authenticity. Fixture Shall Be As Per Is 10322 Complianced. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 / Lm80 ) Certificate / Report With Liable Warranty Of Product / Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Led Street Light Fixture 20 Watt , Led Street Light Fixture 45 Watt , Led Street Light Fixture 70 Watt , Led Street Light Fixture 90 Watt , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , 20 Mm Dia. , 25 Mm Dia. , 32 Mm Dia. , 40 Mm Dia. , Supply And Fixing Of Following Lt Supporting Accessories With Nut Bolt & Clamps Made Out As Per Standard Discoms Specifications. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Suspension Clamp With Eye Hook & Pole Clamp , Supply And Fixing Of Lt Porcelain Pin Insulator As Per Is 1445-1997 Suitable For Working Voltage 1100 Volts Including All Accessories Like Hot Dip Gi Forged Spindle Of 260Mm Long And Nuts Etc As Reqd As Per Standard Discom Specification. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work Refer Annexure A Attached With This Bsr . , 105Mm X 65Mm , Supply And Fixing Of Porcelain Shackle Insulator As Per Is:1443 1979 Suitable For Working On 1100 Volts Including Hot Dipped Gi Accessories And Heavy Duty Hardwares Etc As Requiredas Per Pwd / Discom Specification. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , 75Mm X 90Mm , Supplying And Drawing Of Iso Certified Company Made Xlpe Insulated Lt Aerial Bunched Aluminium Conductor Cable Confirming To Is 14255 / 1995 And Is 398 ( Pt-4 ) / 1994 On Existing Cross Arms Through I Hook With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Requiredas Per Pwd / Discom Specification. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , 1X16 Sq. Mm. ( Insulated ) , 1 X 25 Sq. Mm. + 1X25 Sq. Mm. ( Insulated ) , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc / Ms Conduit / Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , 2 X 1.5 Sq.Mm , P & F Of Ip 55 Protected Light Controlled Switch Based On Infrared Sensing And Daylight With Built In Over Load Protection, Timer To Switch Off At Preselected Time. Switch Shall Have 7 Day Power Backup Without Hampering Of Preset Time And Over Ride Facility For Maintenance Purpose , Suitable For 3 Kw Load Direct Lighting Load ( Single Phase ) , Suitable For 15 Kw Load ( Three Phase ) Including Contactor, Mcb, Cable Glands, Terminal Block And Locking Arrangement , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured / Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- ( A ) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I ( B ) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testing Procedures. ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. , 10.0 Sq. Mm 4 Core , 16.0 Sq. Mm4 Core , 25.0 Sq. Mm4 Core

Key Value

Document Fees
INR 1000 /-
EMD
INR 91920.0 /-
Tender Value
INR 45.96 Lakhs /-

BOQ Items

uxj ifj"kn {ks= esa okMZ u0 31 ls okMZ u0 60 esa LVªhV ykbZV e; vko";d lkexzh lIykbZ dk;ZA
Sl. No. Item Description
1based on Ruidp 2022
2Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.
3OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
4LED Street Light fixture 20 Watt
5LED Street Light fixture 45 Watt
6LED Street Light fixture 70 Watt
7LED Street Light fixture 90 Watt
8Providing & Fixing of Street light bracket made out from following size of " B " class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
920 mm Dia.
1025 mm Dia.
1132 mm Dia.
1240 mm Dia.
13Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom"s specifications. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
14Suspension clamp with eye hook & Pole clamp
15Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 suitable for working voltage 1100 volts including all accessories like hot dip GI forged spindle of 260mm long and nuts etc as reqd as per standard Discom specification. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure "A" attached with this BSR .
16105mm x 65mm
17Supply and fixing of porcelain shackle insulator as per IS:1443 1979 suitable for working on 1100 volts including hot dipped GI accessories and heavy duty hardwares etc as requiredas per PWD / DISCOM specification. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
1875mm x 90mm
19Supplying and drawing of ISO certified company made XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as requiredas per PWD / DISCOM specification. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
201X16 sq. mm. (insulated)
211 X 25 sq. mm. + 1X25 sq. mm. (insulated)
22Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
232 x 1.5 sq.mm
24P & F of IP 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch OFF at preselected time. Switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose
25Suitable for 3 kw load direct lighting load (single phase)
26Suitable for 15 kw load (three phase) including contactor, MCB, cable glands, terminal block and locking arrangement
27Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.
2810.0 Sq. mm 4 core
2916.0 Sq. mm4 core
3025.0 Sq. mm4 core
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail