Repair / Maintenance Of Certain Electrical And Mechanical Works And Day To Day Maint Of Electric Works For Bldgs Of Old And New Abdul Hammed Vihar, Nalwa Road Offr Qtrs, Shehjra Enclave, Ajit Road Fafa, Rana Pratap Enclave, Zorawar Enclave, Manek, jalandhar-Punjab

Military Engineer Services-MES has published Repair / Maintenance Of Certain Electrical And Mechanical Works And Day To Day Maint Of Electric Works For Bldgs Of Old And New Abdul Hammed Vihar, Nalwa Road Offr Qtrs, Shehjra Enclave, Ajit Road Fafa, Rana Pratap Enclave, Zorawar Enclave, Manek. Submission Date for this Tender is 28-09-2022. Electrification Work Tenders in jalandhar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

33740547
Corrigendum : Repair / Maintenance Of Certain Electrical And Mechanical Works And Day To Day Maint Of Electric Works For Bldgs Of Old And New Abdul Hammed Vihar, Nalwa Road Offr Qtrs, Shehjra Enclave, Ajit Road Fafa, Rana Pratap Enclave, Zorawar Enclave, Manek
Open Tender
Indian
Punjab
jalandhar
28-09-2022

Tender Details

Repair / Maintenance Of Certain Electrical And Mechanical Works And Day To Day Maint Of Electric Works For Bldgs Of Old And New Abdul Hammed Vihar, Nalwa Road Offr Qtrs, Shehjra Enclave, Ajit Road Fafa, Rana Pratap Enclave, Zorawar Enclave, Manekshw Vihar, Old Bi Line Offrs Qtrs, Nirman Vihar Nalwa Road Mes Qtrs, Ranjit Chowk, Hardyal Road Mes Qtrs, Green Avenue, Old Bi Line Jcos Qtrs Under Ge ( East ) Jalandhar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Sep-2022 CORRIGENDUM NO. 01 BOQ 21-09-2022
2 21-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work : Repair/ maint of certain E/M works and day to day maint of electric works for bldgs of Old and New Abdul Hammed Vihar, Nalwa Road Offr Qtrs, Shehjra Enclave, Ajit Road FAFA, Rana Pratap Enclave, Zorawar Enclave, Manekshw Vihar, Old BI Line Offrs Qtrs, Nirman Vihar Nalwa Road MES Qtrs, Ranjit Chowk, Hardyal Road MES Qtrs, Green Avenue, Old BI Line JCOs Qtrs under GE (East) Jalandhar Cantt (Tender ID No 2022_MES_549034_1)
Sl. No. Item Description
1Attending complaints of no supply in light or power circuit due to burning/ disconnecting of any wire i.e. neutral phase or tripping of MCB or un-serviceability of any item such as switch socket MCB etc, rectification of fault including any petty repair required to restore the electric supply for checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc, carrying out repairs such as tightening of loosen electric connections, nuts, bolts screws or switches, sockets, switch board, ceiling fans/ exhaust fans etc., required to make the item functional during 0900 Hrs to 1800 Hrs by deploying electrician alongwith helper including necessary tools complete all as specified and directed. Notes:- (a) Replacement of electrical fittings/ fixtures shall be measured and paid for separately under respective item of BOQ. (b) Repairs/ faults in any one quarter upto 8 points/ one occupancy shall be considered as one complaint (one measuring unit) even if repair is involved in more than one light point or fitting. However, all fitting/ fixtures replaced shall be measured & paid. (c) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (d) In case of failure on the part of contractor for attending complaints a penalty shall be imposed and recovered as specified in Particular Specifications. (e) Contractor shall ensure that the deployed electrician & helper will carry functional and live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge. (f) Contractor shall be responsible for collection of all ON LINE complaints and handing over the same to JE E/M after rectification duly signed by user with details of stores fixed and to put the status ON LINE after attending/ complete of the job.
2Supply and fixing in repairs switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified.
3Supply and fixing in repairs bell push switch flush type 5 Amps, SP, 240 volts including taking down existing bell complete all as specified
4Supply and fixing in repairs socket outlet multipurpose 3 in 1, 6 pin, 5 & 15 Amps, flush type including taking down existing socket complete all as specified
5Supply and fixing in repairs socket out let 5 Amp, 5 pin flush type including taking down existing socket complete all as specified.
6Supply and fixing in repairs switch piano flush type, 5 Amps, 240 Volt AC single pole, two way including taking down existing switch complete all as specified.
7Supply and fixing in repairs switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified.
8Supply and fixing in repairs bell electric AC (Ding Dong) 240 volt SP including taking down existing bell complete all as specified
9Supply and fixing in repairs lamp holder insulated body with back plate suitable for batten fittings including taking down existing lamp holder complete all as specified.
10Supply and fixing in repairs fan step regulator, electronic type, single phase, (socket size) including connection complete after dismantling/ removing unserviceable regulator all as specified.
11Supply and fixing in replacement ceiling rose surface type bakelite 65 x 50mm three terminal including taking down complete all as specified and directed.
12Supply and fixing in replacement FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm single core complete including taking down existing wire any type all as specified.
13Supply and fixing in replacement FRLS PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm single core complete including taking down existing wire any type all as specified.
14Supply and fixing in replacement FRLS PVC insulated unsheathed multi stranded copper conductor of size 4.0 Sqmm single core complete including taking down existing wire any type all as specified.
15Supply and fixing in repair energy saving bulk head light luminaire with opal diffuser LED 10 watt 6000 K, power factor more than 0.90, IP-65 class-I protection with high efficiency BIS marked LED electronic driver, surge protection 2 KV, operative on 140 volts to 270 volts AC supply complete prewired, connecting and testing complete all as specified and directed. Notes:- (i) Contractor shall provide 2 years written warranty for the LED fixture complete including driver from the certified date of completion from the local office bearer of manufacturers. (ii) Contractor shall produce LM-79 and LM-80 Report of NABL accredited Laboratory from manufacturer. (iii) Products must be made in India only.
16Material and labour in repair sub main wiring with PVC insulated cable copper conductor FRLS two single core 6 Sqmm drawn through PVC rigid non metallic conduit medium grade with all fittings including earth continuity FRLS copper conductor 6 Sqmm PVC insulated with green insulation complete all as specified. Note : Two runs of single core 6 sqmm and one run of 6 sqmm PVC insulated stranded copper conductor through PVC rigid concealed conduit shall be measured as one RM.
17Material and labour in repair sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit medium grade with all fittings including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified. Note : Two runs of single core 4 sqmm and one run of 4 sqmm PVC insulated stranded copper conductor through PVC rigid concealed conduit shall be measured as one RM.
18Supply and fixing in repairs sheet metal enclosure for DBs when MCBs to be used, SPN 8 ways 240 V, with 200 Amps rated bus bar, double door all as specified
19Supply and fixing in replacement DB"s 4 way TPN double door suitable for MCB FP "A" frame of rating 100 Amps and having breaking capacity 16 KA and MCB SP 6-32 Amps 10 KA (as per site requirement) in outgoing circuits complete pre-fitted, with neutral bar and earth bar complete all as specified. Note : Rates of MCCB and MCB are deemed to included in quoted rates
20Supply and fixing in repairs MCB TPN, 415 volts of rating 63 Amps having breaking capacity 10 KA suitable for DB vertical complete all as specified.
21Supply and fixing in replacement MCB SP 6 to 32 Amps, B Curve, 10 KA as per Osafe series of HPL/ Acti 9 series of Schneider/ Dx3 range of Legrand/ Betagard 5 SL range of Siemens/ STADx range of Havells/ Optipro of Indoasian complete all as specified.
22Supply and fixing in replacement MCB SPN 25 to 32 Amps, B Curve, 10 KA as per Osafe series of HPL/ Acti 9 series of Schneider/ Dx3 range of Legrand/ Betagard 5 SL range of Siemens/ STADx range of Havells/ Optipro of Indoasian complete all as specified.
23Supply and fixing in replacement Deco Ultra Slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 20W LED 6000K complete all as specified and directed Notes : (i) Contractor shall provide 2 years written warranty for the LED fixture complete including driver from the certified date of completion from the local office bearer of manufacturers. (ii)Contractor shall produce LM-79 & LM-80 Report of NABL accredited Laboratory duly signed by the office bearer of manufacturer.
24Supply and fixing in repair universal batten suitable for fixing of T5 LED tube light 20 watt single/ double side connection complete all as specified and directed
25Supply and fixing in repair 18 LED tube light inbuilt LED driver retrofit type single side connection with polycarbonate diffuser having high efficacy suited for installation in T5 fitting holders complete all as specified and directed
26Supply and fixing in replacement Deco Ultra Slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 9W LED 6000K complete all as specified and directed
27Supply and fixing in repair energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 15 watt LED for bldg security lights with high efficiency electronic driver, having IP-65 protection, surge protection min 2 KV power factor more than 0.95 complete operative on AC supply 140 volts to 270 volts pre-wired complete with GI pipe of 25mm bore and MS clamps duly painted with two coats paint and product should be made in India only complete all as specified. Notes for Srl item No. 25 to 27: (i) Contractor shall provide 2 years written warranty for the LED fixture complete including driver from the certified date of completion from the local office bearer of manufacturers. (ii)Contractor shall produce LM-79 & LM-80 Report of NABL accredited Laboratory duly signed by the office bearer of manufacturer.
28Supply and fixing in repair city 1 new decorative wall light fixture made up of polycarbonate, suitable for lamp type 1 x 9 watt retrofit LED lamp including 9 watt LED lamp of same make as fitting complete all as specified.
29Supply and fixing in replacement plastic laminated bakelite sheet top cover 3mm thick make hylum of size 9 x 11 inches or equivalent fixed with nickel polished screws with washers including making hole as per site requirement including taking out complete all as specified and directed
30All as per srl item No. 29.00 here-in-before but 5 x 11 inches
31All as per srl item No. 29.00 here-in-before but 8 x 5 inches
32Supply and fixing in replacement MCCB FP 63 Amp, 415V with adjustable thermal magnetic release upto 16 KA breaking capacity including taking out complete all as specified and directed
33Supply and fixing in replacement MCCB FP 125 Amp, 415V with adjustable thermal magnetic release upto 16 KA breaking capacity including taking out complete all as specified and directed
34Supply and fixing in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp complete all as specified and as directed.
35Supply and fixing in replacement white modular switch 1 way 6 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed.
36Supply and fixing in replacement white modular switch 1 way 16 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed.
37Supply and fixing in replacement fan step regulator, 120W, 2 module including taking down complete all as specified and directed.
38Supply and fixing in replacement modular socket, 6A, 2/3 pin combined 2 module including taking down complete all as specified and directed.
39Supply and fixing in replacement modular socket, 6A/16A, 2/3 pin combined 2 module including taking down complete all as specified and directed.
40Supply and fixing in replacement mini modular MCB SP 32 Amps C-Curve complete all as specified and directed.
41Supply and fixing balnking strips (dummy) 1/2 module for modular switch board complete all as specified and directed.
42Supply and fixing in repairs PVC casing caping (ISI marked) complete all as specified and directed.
43Supply and fixing in repair LED retrofit lamp 9W, 6500K, 220-240V, B-22 base cap complete all as specified and directed. Notes for Srl item No 2 to 43 : (i) Contractor will get make and smaple approval of items reqd to be replaced mentioned at Srl No. 13 to 20 and will hand over after placing work order to JE incharge with all PV & TC to ensure availbilty when reqd during currency of contract and these items/ amteial will be issued by JE E/M daily in complaint cell on actual assessment of complaints to replace the defective prt and for accounting of items. The contractor will maintain register regarding details of daily complaints recd, pending, rectified, items replaced on daily basis duly signed by contractor, JE etc. (ii) The item Srl No. shall be executed on daily basis for attending complaints. Hence, contractor shall qoute his rate accordingly. (iii) Old retrieved material shall be deposited to JE E/M in AGE E/M yard/ E/M wksp on same day and will be given to contractor only at the time of RAR after necessary recovery under Sch of Credit.
44Attending complaints of not working/ abnormal noise of fans/ exhaust fan due to loose connection of any wire i.e. neutral/ phase not working of circuits or un-serviceability of any item such as capacitor, rubber real, wire etc rectification of fault including any sort of petty repair required to make the fans functional during 0900 Hrs to 1800 Hrs by deploying electrician with helpers including necessary tools complete all as specified.
45Supply and fixing in repairs condenser 2.50 MFD including taking down existing complete all as specified.
46Supply and fixing in repairs condenser 3.15 MFD including taking down existing complete all as specified.
47Supply and fixing in repairs rubber reel for ceiling fan including nut & bolt including taking down existing rubber real complete all as specified.
48Supply and fixing in repairs flexible wire twisted twin core of size 0.75 Sqmm copper conductor cable connected from fan block to 0.60m long (provn for ceiling fan & exhaust fan ceiling rose) complete all as specified.
49Material and labour for point wiring with 1.5 sqmm (nominal area), 1100 volt grade FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmmcable drawn in and including concealed rigid PVC conduit medium grade (ISI marked) not less than 20mm dia with accessories including cutting chases for laying of conduit/ fixing of boxes in walls/ floors etc including making good to disturbed surfaces as per adjoining specification and terminated in and including sunken pressed steel boxes duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated Bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble for one light point controlled by one switch complete all as specified and as directed.
50All as per srl item No. 49.00 above but for one fan point controlled by one switch.
51All as per srl item No. 49.00 above but for one bell point controlled by one bell push.
52All as per srl item No. 49.00 above but for one light point controlled by two way switches.
53All as per srl item No. 49.00 above but for one socket outlet 5 Amps on independent board.
54All as per srl item No. 49.00 above but for one socket outlet 5 Amps on same board with other switches.
55All as per srl item No. 49.00 above but with 2.5 Sqmm copper (nominal area) FRLS cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm with stranded copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed