Repair Maintenance Of Dg Sets Amf Panels At Jasai Mil Stn Under Ge A Barmer, barmer-Rajasthan

Military Engineer Services-MES has published Repair Maintenance Of Dg Sets Amf Panels At Jasai Mil Stn Under Ge A Barmer. Submission Date for this Tender is 28-09-2022. Diesel Generators Tenders in barmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

33740375
Corrigendum : Repair Maintenance Of Dg Sets Amf Panels At Jasai Mil Stn Under Ge A Barmer
Open Tender
Indian
Rajasthan
barmer
28-09-2022

Tender Details

Repair Maintenance Of Dg Sets Amf Panels At Jasai Mil Stn Under Ge A Barmer

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR/MAINTENANCE OF DG SETS, AMF PANELS AT JASAI MIL STN UNDER GE (A) BARMER
Sl. No. Item Description
1M&L for maintenance and servicing of DG sets(monthly Inspection),of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a)380 KVA Capacity-01 Nos (b)250 KVA Capacity- 01 No (c) 125 KVA Capacity - 01 No (d) 100 KVA Capacity - 06No (e) 82.5 KVA Capacity - 01 No (f)62.5 KVA Capacity- 03No (g) 40 KVA Capacity- 01 No (h) 30 KVA Capacity - 02 No (j) 25KVA capacity:-02 No (k) 20KVA Capacity:-01 No
2Note: (i) Checking engine oil level and topping up as and when required .Oil shall be measures and paid separately (ii) Checking and adjusting the belts for tension and replacement of belts. Note : Belt shall be measured and paid seperately (iii) Checking of air filter element all type. (iv) Checking of exhaust system for any leakage. (v) Draining of sediment/water from fuel filter and fuel tank. (vi) Cleaning of air cleaner element all type. (vii) Checking engine alternator coupling, mounting bolts and alignment. (viii) Tightening of all nuts and bolts in altenator terminal block. (ix) Checking of alternator carbon brush and connections in alternator. (x) Checking and tightening of all connection in DC control wiring. (xi) Checking of all radiator rubber hose, pipe clips and replacement if required. (xii) Checking and recording oil pressure, water and oil temperarute. (xiii) Checking anti vibration mounting and replacement if required. (xiv) Checking throttle linkage. (xv) Checking battery for cell test, electrolyte level, gravity and topping up to required level (xvi) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. Replacement of Door hinges, locks etc also deemed to be inclusive in quoted rates. (xvii) Checking of AMF panel, all electrical connections etc. (xviii) Checking of earthing resistance. (xix) Cleaning of vegitation around the DG set up to 1.5 mtr area. (xx) Contractor shall employ skilled labour (FGM) for the above repairs and one company engineer/ technician for over all repairs once every in month.
3M&L for Inspection, maintenance and servicing of DG Sets of following Capacities including alternator, electric panel board connection to DG set for routine check (B - Check) of DG set for smooth functioning and carrying out maintanance complete all as directed and specified. Note: (i) B-Check once in six month OR 250 Hrs running of DG set whichever is earlier. (ii) B- Check of all DG sets ones shall be paid as one Job (iii) All spare parts required shall be measured and paid separately as supply only (a)380 KVA Capacity-01 Nos (b)250 KVA Capacity- 01 No (c) 125 KVA Capacity - 01 No (d) 100 KVA Capacity - 06No (e) 82.5 KVA Capacity - 01 No (f)62.5 KVA Capacity- 03No (g) 40 KVA Capacity- 01 No (h) 30 KVA Capacity - 02 No (j) 25KVA capacity:-02 No (k) 20KVA Capacity:-01 No
4Note: (i) Repeat the activities of A Check including replacement of lubricating oil. (ii) Replacinglubricant oil filter element with "O" ring (iii) Replacing fuel filter element (primary and secondary) (iv) Replacing coolant (For Radiator) (v) Replacing Governer oil. (vi) Coolent, Lubricant oil shall be measured and paid seperately under relevant items (vii) Contractor shall employ skilled labour (FGM) for the above repairs and one company engineer/technician for over all repairs (viii) Replacing water body assembly. (ix) Replacing water separater. (x) Cleaning of Radiator with chemicals and replacement of radiator filter . (xi) Replacement of by pass filter. (xii) Checking of all radiator rubber hose and replacement if required. (xiii) Checking and recording oil pressure, water and oil temperarute (xiv) Checking anti vibration mounting and replacement if required. (xv) Checking throttle linkage (xvi) Checking battery for cell test, electrolyte level, gravity and topping up to required level (xvii) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. Replacement of Door hinges, locks etc also deemed to be inclusive in quoted rates. (xviii) Checking of AMF panel, all electrical connections etc. (xix) Checking of earthing resistance (xx) Cleaning of vegitation around the DG set up to 1.5 mtr area.
5Supply only Radiator Coolent complete all as specified and directed .
6Supply only Diesel/ Fuel filter (Primery&Secondary) for 25 to 100 KVA DG Set.
7Supply only Diesel/ Fuel filter (Primery&Secondary) for 125 to 380 KVA DG Set.
8Supply only Fan belt suitable for DG sets upto 380KVA capacity.
9Supply only defective fuel injectors suitable for DG sets upto 380KVA capacity.
10Supply onlyEngine oil / Lube filter suitable for 25 KVA to 100 KVA DG Set
11Supply only Engine oil /Lube filter suitable for 125KVAto 380 KVA DG Set
12Supply only Air cleaner elements inner and outer suitable for 45 KVA to 125 KVA DG Sets
13Supply only Air cleaner elements inner and outer suitable for 250 KVA to 380 KVA DG Sets
14Material and labour for replacement of lub oil pump suitable upto 380 KVA DG Setcomplete all as specified and directed .
15Supply & fixing in replacement Diesel pipe set flexible suitable upto 380KVA DG Set incl benjo bolts, copper washers complete all as specified and as directed .
16Supply and fixingin repair Lead acid battery 12 Volts, 150 AH with initially charged all as specified and as directed .
17Supply only cotton waste for dialy use at power house for cleaning of the DG sets, pump motors complete all as specified and directed .
18M&L for engine oil, multi grade 15W40.
19Dismantling the radiator and fan assembly from the engine for cleaning of copper tubes and cooling fins by using descaling solution, soldering, patch work if any leakage including transporting to workshop for repair and bringing back to site upto 380 KVA all as directed .
20M&L for replacement of defective water pumping assembly upto 380 KVA all as directed .
21M&L for repairing of alternator of DG set having capacity upto 125 KVA DG set all as directedincluding following: (a) Disconnecting electrical cable connection of alternator and DG set coupling complete. (b)Dismantling of alternator complete for rewinding including burntout winding field winding coils and cleaning slots. (c)Rewiring of armature and field coil with super enamelled copper winding wire insulated complete with suitable size of copper wire. (d) Material and Labour for replacement of u/s alternator bearing. (e) cleaning of commutator and replace carbon brush set complete including service of brush holders. (f) Re-assembling of alternator complete after the repair/rewinding and servicing of alternator, general cleaning and greasing of bearing and make good by provision of proper alignment and electic connection.
22Supply and fixing in repair of AVR for DG set having capacity 100 KVA to 125 KVA all as directed .
23Supply and fixing in repair of AVR for DG set having capacity 380 KVA all as directed .
24S&F Self starter armature, 12V DC of make & model suitable for existing self starter.
25S&F 12V solenoid coil suitable for DG set upto 380KVA capacity of existing make & model.
26M&L for dismantling self starter 12 V of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt aremeture, rewinding of Fd coils, replace of pinion gears etc, complete servicing and refixing after repair, testing/commissioning complete for DG Set of any capacity
27Supply & Fixing in repair of heat proof asbestos rope 12 mm dia in engine exhaust pipe including dismantling of worn out Asbestos rope and minor welding/tightening in leakage exhaust complete all as directed conforming to IS specification fire proof/flame proof.
28Servicing of AMF Panel of DG set and cleaning of dust by using blower & cleaning agents,checking / Detecting faults , Removing Faults, Re-wiring of old unserviceable wiring & testing of control wiring including. replacement of un-serviceable parts of AMF Panelall as requirement and testing on completion of job on existing loadcomplete all as specified and as directed . NOTE:- Un-serviceable parts shall be measured and paid separatly as supply only.
29S&F in replacement 2 core 10 Sqmm weather proof, PVC insulated and PVC sheathed multi stranded aluminium conductor cable, flat type 1100 volts as in service connection etc complete.
30Supply & Fixing in repair of Indicating Light, 240V AC, LED Type Red, Yellow, Blue.
31Supply & Fixing in repair of Digital DG Set Controller as per existing model.
32Supply & Fixing in repair of Ammeter Digital Type of existing model.
33Supply & Fixing in repair of Voltmeter Digital Type of existing model.
34Supply & Fixing in repair of Self Carbon Bush suitable for DG Set.
35Supply & Fixing in repair of Oil Pressure Gauge of existing model.
36Supply & Fixing in repair of Push switch STOP EMERGENCY
37Supply & Fixing in repair of Battery lead (using multistranded copper conductor with end terminal lugs)
38Supply & Fixing in repair of Selector switch of existing model.
39Supply & Fixing in repair of Current Transformer (200/5) of existing model.
40M & Lin replacement earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including galvanized earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 typeC1in chamber, precastRCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m. NOTE : Item includes the cost of earth lead and GI protection pipe upto 7.5m.GI wire beyond 7.5m shall be measured and paid for separately.
41S & F in repair Changeover switch 200 Amps 415 Volt with sheet metal enclosure, side handle operated .
42S & F in repairChangeover switch 100 Amps 415 Volt with sheet metal enclosure side handle operated..
43S & F deisel tank for 100 KVA Sudhir-Cummins DG Set with capacity 200 lts having fuel level indicator with its mounting stand.
44M&L for Movable Battery charger suitable for charging upto 12-24 volts, full load current upto 200AH.
45S&F in replacement MCCB 400 Amps 03 Pole, 415 Volts, 50 Hz, 36 KA complete with spreader and connecting limbs etc. complete.
46M&L for repairing of Fuel Feed Pump complete suitable upto 380KVA.