| 1 | Engagement of Site-in-Charge cum Supervisor on regular basis throughout the Work period of the Contract. |
| 2 | Engagement of Skilled Technician for electrical operational & Monitoring and Routine/Preventive/Breakdown Maintenance work. (5 Nos of Skilled Person) |
| 3 | Engagement of Semi-skilled Technician support for electrical operational & Monitoring and Routine/Preventive/Breakdown Maintenance work. (5 Nos of Semi - skilled Person) |
| 4 | Emergency Breakdown during Odd Hrs. |
| 5 | Supply & Replacement of 1-way Piano Type Switch 5/6A , Make/Model- “Anchor PentaCherry” or equivalent by new one. |
| 6 | Supply & Replacement of 2 in one Socket6 A , Make/Model- “Anchor PentaSocket” or equivalent by new one. |
| 7 | Supply & Replacement of 6A Bell Push Switch , Make/Model- “Anchor PentaCherry” or equivalent by new one. |
| 8 | Supply & Replacement of Angle Holder , Make/Model- Anchor code-14706 or equivalent by new one. |
| 9 | Supply & Replacement of 1-way Switch 15/16A , Make/Model- “Anchor Capton Series” or equivalent by new one. |
| 10 | Supply & Replacement of 16 A 3 Pin Socket , Make/Model- \"Anchor Capton Series” or equivalent by new one. |
| 11 | Supply & Replacement of 20/10A Power Socket equivalent to Capton 5-in 1 combined unit (Switch, Socket, Fuse & indicator) With four fixing holes. |
| 12 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required , Make/Model- Anchor Deluxe Fan Regulator or equivalent by new one. |
| 13 | Supplying & fixing of 4 Module (125mmX75mm) size/modules GI box along with modular base & cover plate for modular board as required |
| 14 | Supplying & fixing of 8 Module (125mmX125mm) size/modules GI box along with modular base & cover plate for modular board as required |
| 15 | 5-10 amps modular switch = Supply & Replacement of above modular switch/ socket by new one including Supply of materials & fixing both |
| 16 | 15-20 amp modular switch = Supply & Replacement of above modular switch/ socket by new one including Supply of materials & fixing both |
| 17 | 03-pin 5-10 amp socket outlet modular switch=Supply & Replacement of above modular switch/ socket by new one including Supply of materials & fixing both |
| 18 | 6-pin 15-20 amp modular socket outlet= Supply & Replacement of above modular switch/ socket by new one including Supply of materials & fixing both |
| 19 | Bell push= Supply & Replacement of above modular switch/ socket by new one including Supply of materials & fixing both |
| 20 | Supplying and fixing modular blanking plate on the existing modular plate & switch box as required. |
| 21 | Supply, replacement and fixing of1 or 2 Module Modular base & cover plate on existing modular metal boxes etc. as required |
| 22 | Supply, replacement and fixing of3 Module Modular base & cover plate on existing modular metal boxes etc. as required |
| 23 | Supply, replacement and fixing of 4 Module Modular base & cover plate on existing modular metal boxes etc. as required |
| 24 | Supply, replacement and fixing of 6 Module Modular base & cover plate on existing modular metal boxes etc. as required |
| 25 | Supply, replacement and fixing of 8 Module Modular base & cover plate on existing modular metal boxes etc. as required |
| 26 | Supply, replacement and fixing of damaged10” X 8”size Switch Board by new one including top cover / 3 mm thick Perspex sheet cover (sun mica) top wooden board after necessary cutting for switches, socket etc. and complete with all materials and labour. |
| 27 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 28 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 29 | Supply & fixing ofSingle Pole, 5 amps to 32 amps rating, 240/415 volts, \"C\" curve,MCB |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral. |
| 31 | Supply & Replacement of call bell/ buzzer suitable for single phase, 230 V by new one. |
| 32 | Transportation, handling & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of1.1 KV Voltage Grade, Upto 35 sq. mm size direct in ground including excavation, sand cushioning, protective covering (Brick solling) and refilling the trench etc. as required. of following size (trench size and laying of cable should be as per IS specification) (note-Cable will be provided by DVC free of cost) |
| 33 | Transportation, handling & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV Voltage Grade, Above 35 sq. mm and up to 95 sq. mm size direct in ground including excavation, sand cushioning, protective covering (Brick solling) and refilling the trench etc. as required. of following size (trench size and laying of cable should be as per IS specification) (note-Cable will be provided by DVC free of cost) |
| 34 | Transportation, handling & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV Voltage Grade, Above 95 sq. mm and upto 185 sq. mm. size direct in ground including excavation, sand cushioning, protective covering (Brick solling) and refilling the trench etc. as required. of following size (trench size and laying of cable should be as per IS specification) (note-Cable will be provided by DVC free of cost) |
| 35 | Transportation, handling & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV Voltage Grade, Above 185 sq. mm and upto 300 sq. mm. size direct in ground including excavation, sand cushioning, protective covering (Brick solling) and refilling the trench etc. as required. of following size (trench size and laying of cable should be as per IS specification) (note-Cable will be provided by DVC free of cost) |
| 36 | Supply, laying and fixing 100 mm dia G.I. pipe (medium class) after cutting the road/PCC for incoming to the building in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required for laying of cable. |
| 37 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 38 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and altering pipe etc. with charcoal/coke and salt as required. |
| 39 | Transportation, handling & Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 11KV (3C 185sqmm or 1C 630 sqmm) grade ofdirect in ground including excavation, sand cushioning, protective covering (brick solling) and refilling the trench.(trench size and laying of cable should be as per IS specification) (note-Cable will be provided by DVC free of cost and all other man & materials will be provided by the contractor) |
| 40 | Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of any electrical equipment (Transformer/LT Panel etc.) including form work etc. as required. |
| 41 | Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 42 | Rewinding of different type of Fans (it includes ceiling fans/ Wall mounted fan/exhaust fan) |
| 43 | Supply & Replacement of capacitor of above Fans |
| 44 | Minor maintenance of single phase Fan/motor with greasing, resoldering, split pin, flexible wire, counter screw Top-nuts/bolts etc, with supply & replacement of Bushing/rubber bobins etc. |
| 45 | Supply and Replacement of bearings Bearing no: 6200 to 6204 may used as per requirements. |
| 46 | Consumables |
| 47 | EXTRA MANDAYS-Engagement ofTECHNICIAN with specified skill & experience to take up works during maintenance activity (if required)as per the instruction of EIC. |
| 48 | EXTRA MANDAYS-Engagement of WELDER/FITTER/Skilled with specified skill & experience to take up works during maintenance activity (if required)as per the instruction of EIC. |
| 49 | EXTRA MANDAYS-Engagement of HELPER with specified skill & experience to take up works during maintenance activity (if required)as per the instruction of EIC. |