Construction Of Rcc Perimeter Security Wall At Af Stn Srinagar , srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Construction Of Rcc Perimeter Security Wall At Af Stn Srinagar . Submission Date for this Tender is 21-09-2022. Wall construction Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

33716450
Corrigendum : Construction Of Rcc Perimeter Security Wall At Af Stn Srinagar
Open Tender
Indian
Jammu And Kashmir
srinagar
21-09-2022

Tender Details

Construction Of Rcc Perimeter Security Wall At Af Stn Srinagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Sep-2022 Other corrigendum 01 Other 14-09-2022
2 14-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-09-2022

Key Value

Document Fees
INR 3000 /-
EMD
INR 750000.0 /-
Tender Value
INR 8.50 Crore /-

BOQ Items

Name of Work:CONSTRUCTION OF RCC PERIMETER SECURITY WALL AT AF STN SRINAGAR.
Sl. No. Item Description
1Sch "A" Part-ISITE CLEARANCE WORKS AND COMMON NATURE ITEMS.
2M&L for Grubbing up tree (girth below 06 inches (dia) trunk including cutting of trunk portion protruding over ground, digging out roots filling holes and levelling of ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc 50m and clearing sitecomplete all as specified and as directed.
3Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil completed all as specified.
4Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (n.exc 1.5 m or part thereof in depth as well as 10 sqm on plan) including getting out any type of soil and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge
5Removing of surplus soil to a distanceexc. 50 mtrbut n.exc 250 mtr and deposited where directed at a level not exceeding 1.50m from the starting point, complete all as specified and as directed.
6Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and as directed.
7Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on planfor laying cables in trenches /erection of pole / stay assemblyand getting out complete all as specified and asdirected by Engr-in-charge.
8Removing of surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed by Engr-in-Charge.
9Sch "A" Part-IIDEMOLITION WORKS.
10Dismantling timber scantlings under 40 sq. cm and over in section, in any position complete all as specified and as directed.
11Dismantling boarding, any description, fixed in any position with nailscomplete all as specified and as directed.
12Dismantling of Plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
13Taking down casing ring of rolling shutters and welding broken flat iron piece for strengthening the ring complete all as directed. complete all as specified and as directed.
14Demolition and dismantiling of Brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articlescomplete all as specified and asdirected.
15Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking outembedded portion and making good disturbed ground.complete all as specified.
16Dismantling expanded metal, any thickness or mesh, fixed with steel or wood fillets exc 4 Kg per Sqm.Complete all as specified and directed by Engineer–in–Charge.
17Dismantling wrought iron or mild steel work of any description not otherwise provided Complete all as specified and directed by Engineer–in–Charge.
18Sch "A" Part-IIIRCC WALLWORKS: -
19M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of poles and stay assembly for bed concrete complete all as specified and directed by Engr-in-Charge.
20M&L for RCC M-30 (20mm graded crushed stone aggregates) design mix inFoundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge.
21M&L for RCC M-30 (20mm graded crushed stone aggregates) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresse complete all as specified and directed by Engr-in-Charge.
22M&Lfor Mild steel bars 10mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed by Engr-in-Charge.
23M&L forFormwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter including rough finished surfacecomplete all as specified and directed by Engr-in-Charge.
24M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter and including fair finished surfaces complete all as specified and directed by Engr-in-Charge.
25Supply only 25 mm thick pre-formed filler for expansion joints complete all as specified and directed by Engr-in-Charge.
26M&L for preparation of new RCC surface and applying two coats of cement base paint on RCC wall including curing before and after applying each coat completeall as specified and directed .
27S&F PVC (SWR) pipes single socketed 100mm dia bore,inanylength with rubber ring joints, laid in trenches orin floorscompleteall as specified and directed ..
28Sch "A" Part-IVPCC PATHWORKS
29M&L 100 mm thick hard core (broken stone) of gauge not exceeding 63 mm deposited spread and levelled in layers not exceeding 15 cm thick watered, rolled and rammed to ture surface complete all as specified.
30M&L 50 mm thick cement concrete (1:2:4) type B-2 (Using 40 mm graded crushed stone aggregate) as in flooring complete all as specified.
31M&L 75 MM thick cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in flooring complete all as specified
32Forming contraction joints 30 mm deep x 10 mm wide filled with sealing compound grade "A" with a coat of bituminous primer. complete all as specified and as directed.
33Sch "A" Part-VEXTERNAL ELETRIFICATION WORKS.
34Supply,installation and erection in true vertical or to be planted as strut steel tubularswaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top,poles made out of ERW MS tubing confirming toIS-1161 part-II, type 410 SP -31(9.0m long) including drilling of holes of required size and nos for fixing of cross arms/clamps,poles shall be coated with black bituminous paint conforming to IS: 158-1968,throughout, internally and externally,painting with one coat of red oxide primer and two coats of aluminum paint for expose surface and two coats ofblack bituminous paint for portion embedded in concrete, painting three black/white bands at lower portion of pole each of 300mm height at 300mm spacing, painting pole no. with black paint at suitable height complete all as specified and directed .
35S&F LED Street Light fitting 70 watt, for operating voltage between 110V to 320V system efficiency not less than 120 lumen / watt,PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span ofminimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution,weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and asdirected by Engr-in-charge.
36Supply & Fixing Bracket made out of GI light grade pipe of size 40/35 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 5mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specifiedand asdirected by Engr-in-charge.
37M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr-in-charge.
38Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cableXLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 4.0 core 25sqmmconfirming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge.
39M&L wiring usingPVC insulated and unsheathed multistranded FRLS copper conductorcable with approved colour code as per ISusing two single corePVC insulatedFRLS cable 1.5 sqmm copper conductor multi stranded ( Phase and neutral) and1.5 sqmm copper conductor insulated cable as earth wiredrawing in and includingPVC conduitnot less than 2.00 mm thick ,20 mm outer dia(ISI marked)with all accessoriesNote :2 runs of 1.5 sqmm copper cable & 1 run of 1.5sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit complete all as specified and directed
40Supply and fixing hot pressed moulded Glass reinforced polyester sheet moulding compound(SMC) Junction box of dimensions 350mm x 250mm x 150mm, SMC conforming to IS: 13410:1992 Grade S1, thickness of SMC sheet not less than 1.5mm, outdoor type, single door hinged with front side opening, weather proof, suitable locking arrangement at front, arrangement for incoming and out going cable entry at the bottom, earthing arrangement using One No. of Earthing bolt of MS with 2 nuts and 2 washers provided on RH side of box, Earthing sign has to be provided near to earthing bolt complete all as specifed and comprising of the followings items as under:- (a) Three phase and neutral bus bar duly colour coded of capacity 100 amps using aluminium strips of size 25mm x 4mm mounted on epoxy resin base insulators, drilled holes for cable for cable connection on bus bar including provision of PVC cable of suitable size and length from bus bar to MCB. (b) MCB SPN 5 to 30 Amps - 01 No (c) Provision of clamp for mounting on pole, clamp made from 20mm x 5mm flat iron of suitable shape and length duly fixed with nuts and bolts on the rear side of box.
41S & F GI pipe light grade 40 mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos(Flat iron 50x6mm) with ,nuts and bolts for fixing on polecomplete all as specified and as directed.
42M & L for sand cushioning to underground cable with dry sand locally available 8cm thick before laying of the cable and 15cm thick after laying and stretching the cable below the bricks/PCC cover, punning of sand using suitable T&P as per site condition,complete all as specified and as directed by Engr-in-Charge. Note: Punned thickness of sand to be consider for measurement purpose .
43M&L for plain cement concrete1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of stay assembly and pole complete all as specified and directed by Engr-in-Charge.
44M&L for well burnt sub class B old size bricks laid dry , flat, over the cable abutting each other , width equal to width of brick , complete all as specified and directed
45Total amount of ScheduleA PART-VISchedule of ofCredit ofRs (as mentioned in schedule of credit) for retrieved material on relevant page of schedule of credit of Tender documents in PDF formatwhich will be deducted offline during acceptance of Tender
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail