E-Bid For Rate Contract Cum Supply And Empanelment Of Surgicals ( Drug Items ) 1. S-3 Asepto Syringe With Transparent Bulb Sterile, 60 Ml Piece 36 Months Class B 7946 2. S-43 ( I ) Endotracheal Tube, Plain - Size 6.5Mm Transparent , Jaipur-Rajasthan

Rajasthan Medical Services Corporation Limited has published E-Bid For Rate Contract Cum Supply And Empanelment Of Surgicals ( Drug Items ) 1. S-3 Asepto Syringe With Transparent Bulb Sterile, 60 Ml Piece 36 Months Class B 7946 2. S-43 ( I ) Endotracheal Tube, Plain - Size 6.5Mm Transparent . Submission Date for this Tender is 15-10-2022. Measuring and Layout Tools Tenders in Jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

33712042
Corrigendum : E-Bid For Rate Contract Cum Supply And Empanelment Of Surgicals ( Drug Items ) 1. S-3 Asepto Syringe With Transparent Bulb Sterile, 60 Ml Piece 36 Months Class B 7946 2. S-43 ( I ) Endotracheal Tube, Plain - Size 6.5Mm Transparent
Open Tender
Indian
Rajasthan
Jaipur
15-10-2022

Tender Details

E-Bid For Rate Contract Cum Supply And Empanelment Of Surgicals ( Drug Items ) 1. S-3 Asepto Syringe With Transparent Bulb Sterile, 60 Ml Piece 36 Months Class B 7946 2. S-43 ( I ) Endotracheal Tube, Plain - Size 6.5Mm Transparent Standard 15 Mm Connector At Proximal End Radio-Opaque Line Throughout The Length Tip Suitable For Nasal And Oral Intubation Single Use, Sterile Each Piece 36 Months Class B 21576 3. S-43 ( J ) Endotracheal Tube, Plain - Size 7Mm  Transparent  Standard 15 Mm Connector At Proximal End  Radio-Opaque Line Throughout The Length  Tip Suitable For Nasal And Oral Intubation  Single Use, Sterile Each Piece 36 Months Class B 23840 4. S-43 ( K ) Endotracheal Tube, Plain - Size 7.5Mm  Transparent  Standard 15 Mm Connector At Proximal End  Radio-Opaque Line Throughout The Length  Tip Suitable For Nasal And Oral Intubation  Single Use, Sterile Each Piece 36 Months Class B 22288 5. S-43 ( L ) Endotracheal Tube, Plain - Size 8Mm  Transparent Standard 15 Mm Connector At Proximal End  Radio-Opaque Line Throughout The Length Tip Suitable For Nasal And Oral Intubation Single Use, Sterile Each Piece 36 Months Class B 16474 6. S-43 ( M ) Endotracheal Tube, Plain - Size 8.5Mm Transparent Standard 15 Mm Connector At Proximal End  Radio-Opaque Line Throughout The Length  Tip Suitable For Nasal And Oral Intubation  Single Use, Sterile Each Piece 36 Months Class B 13232 7. S-44 ( A ) Endotracheal Tube, Cuffed - Size 4Mm  Soft Cuff Towards The Distal End  Kink Resistant Inflation Tube Murphy Eye At Distal End With Polished Smoothness  Radio-Opaque Line  Standard 15 Mm Connector  Sterile, Single Use  Curved Shaped Blister Pack – Suiting The Shape Of Product Each Piece 36 Months Class B 20190 8. S-44 ( B ) Endotracheal Tube, Cuff - Size 4.5Mm Soft Cuff Towards The Distal End Kink Resistant Inflation Tube Murphy Eye At Distal End With Polished Smoothness Radio-Opaque Line Standard 15 Mm Connector Sterile, Single Use  Curved Shaped Blister Pack – Suiting The Shape Of Product 15. NE32 B Specifications of Bed side Leucodepletion Filters for Blood Transfusion:-(For two unit of red cell ) 1. Filters should be able to leuco-deplete red cells form leukocyte contamination separately for 1 unit of red cells and for 2 units of red cells each. 2. Filters should be having the capacity of log 4 reduction (99.99%) 3. Filters should not carry any charges it should be neutrally charged. 4. Filters material should be polyester woven / non- woven. 5. Leukocytes should be consistently averaging less than 0.5x105 residual leucocytes for one unit of red cell and 0.2*106 for two units of red cell. RBC recovery should be averaging more than 90%. 6. Filters should have hard / soft housing for optical monitoring. 7. Filtration loss should not be more than 35 ml for one unit red cell. 8. Should have integrated ≥ 40 μm, micro aggregate filter. 9. Should be US FDA/ European CE Certified. 40 Filters per Box 24 months -- 20000 16. NES7 Dockable red cell filter 1. The predeposit storage leucodepletion filter for the leucodepletion of whole blood packed cells. 2. Filtration of whole blood and red cells must be completed for >90% of bags within 45 minutes from time at which flow of blood into the filter is opened. 3. The filter should be able to reduce the final count of leucocyte in the product to <5×10^6 per bag. 4. The filtration process should not reduce red cell to less than 85% of the initial red cell mass percentage of haemolysis<1%. 5. Usable with blood of core temperature in the range 4°C-30°C. 6. Filter material should be highly porous polyurethane/polyester material to ensure quality of red cell during filtration. 7. Filter should have a Pre filter 200micro meter to ensure two step filtration of blood . 8. Filter housing: Material should be polycarbonated with housing volume of max 40ml. 9. Bag should be sterilized by Beta irradiation. 10. The device should have drip chamber with by pass and one way valve to remove air inside the bag. 11. Transfer bag should be attached and have minimum 300ml capacity. 12. Each Dockable filter should be in a separate casing to maintain integrity and shape of the filters. 13. Market standing of more than 4 years. 14. Should have expiry of more than 18 months at the time of supply. 15. Product labels should barcoded as per ISBT128. Secondary packing and shipping cartoons should be barcoded as per GSI-28. 40 Filters per Box 24 months -- 5000 17. NES8 Single Blood Bags {350ml) General Specifications Annexure- XVI and Specification in Annexure-XVII Each Piece 24 months -- 150000 18. NES9 Double Blood Bags with SAGM (350ml) General Specifications Annexure- XVI and Specification in Annexure-XVIII 19. NES10 Double Blood Bags with SAGM (450ml) General Specifications Annexure- XVI and Specification in Annexure-XIX Each Piece 24 months -- 200000 20. NES11 Triple Blood Bags with SAGM (350ml) General Specifications Annexure- XVI and Specification in Annexure-XX Each Piece 24 months -- 75000 21. NES12 Triple Blood Bags with SAGM (450ml) General Specifications Annexure- XVI and Specification in Annexure-XXI Each Piece 24 months -- 75000 22. NES13 Quadruple Blood Bags with SAGM (350ml) General Specifications Annexure- XVI and Specification in Annexure-XXII Each Piece 24 months -- 40000 23. NES14 Quadruple Blood Bags with SAGM (450ml) General Specifications Annexure- XVI and Specification in Annexure-XXIII Each Piece 24 months -- 40000 24. S-138 Core biopsy instrument with compatible co-axial needle (Automatic disposal ) Should be bevel tip.Should have adjustable penetration depth of 18mm and 25 mm with automatic and semi-automatic firing modes in single instrument/gun. Should have fire ready indicator to reduce the risk of premature instrument firing.Should have advanced Echogenic Technology for enhanced visibility in ultrasound. Should be available with compatible coaxial needle in a single kit. Instrument / Gun Size: 18 Gauge, 16cm with Coaxial Needle Size: 17 Gauge, Total Cannula Length 12.9cm. Each Piece 24 months -- 19200 25. S-139 Disposable bone marrow biopsy needle Should have ergonomic two- piece T-handle design. Should have trocar tapered stylet point for easy coring of bone.Should have triple crown cannula tip with 6 cutting cannula facets.Should be available with marrow acquisition cradle with sample size verification marking. 11Gauge, 4 inch Length Each Piece 24 months -- 10080 26. S-140 Eyelid occlusion dressing Should have width of 3.5 to 4.0 cm & Length of 9.5 to 10.0cm, Dual Zonel with Central Zone as Transparent window, Material-100% polyurethane Clear Film layer, Made up of Polyester Non-Woven Fabric, Latex Free, Solvent based Acrylic adhesive, A set of 2 sterile dressing , CE Certified. Each Piece 24 months -- 480000 27. S-141 Eye pressure shield Should be made up of Soft Foam and Rigid Plastic Shield, Length of 178 to 185 mm and width of 83 to 88mm, Foam Thickness of 17 to 19mm. Plastic Type Triton TX-2001, Enough holes on Nasal rib and either side of the shield to prevent condensation, Weight not more than 50gms, CE Certified

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 04-10-2022 corrigendum 15-10-2022
2 15-09-2022 Corrigendum for date extension 29-09-2022
3 23-09-2022 corrigendum 10-10-2022

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 113 Crore /-