Construction Of Solar Power Control Room At Rac Under Bau, Kanke, Ranchi.
Tender Value
8.13 Lakhs
Estimated cost
Bid Submission
05 Sep 2022
0 days left
EMD
16300
Bank guarantee accepted
Document Fee
1250
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kanke → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Solar Power Control Room At Rac Under Bau, Kanke, Ranchi.
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil ( vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling,ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of Ei I |
| 2 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I |
| 3 | Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) cum 7210.55 |
| 5 | providing designation 75A brick work in C.M.(1:6) in foundation and plinth -do |
| 6 | Providing 25mm thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cico or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete, as per building specification and direction of E/I |
| 7 | Providin designation 75A Brick work in C.M.(1.6) In superstructure -do-- |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Providing Tor steel reinforcement of 8mm mm dia rods as per approved -do-TMT Fe 500 (Only valid for Tata (Tiscon). SAIL, JSPL, Electrosteel Steel Ltd. Bokaro and Vizag (RINL)). |
| 10 | Providing Tor steel reinforcement of 10 mm ,12 mm ,16 mmdia rods as per approved design and drawing- do--a) 10 mm TMT Fe 500 (Only valid for Tata (Tiscon). SAIL, JSPL, Electrosteel Steel Ltd. Bokaro and Vizag (RINL)). |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | Providing 12mm thick plaster (1:6) with clean coarse sand of FM 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 13 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I |
| 14 | Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm M.S. square bars fitted on 25x25x6mm M.S. Angle frame of size 60x60x6mm including cost of fabrication providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I (when steel is not supplied |
| 15 | Supplying,fitting and fixing 20 guage G.C.l. sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication, pro viding necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1.2.4 ) blocks of required size, applying a primingred lead paint over steel work, taxes all complete as per drawing specrfication and direction of E/|. |
| 16 | Providing two coats of synthetic enamel paint & Providing primer one coat of red lead paint approved shade and made over steel surfaceincluding cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I |
| 17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required Including the costof EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 18 | Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . 4.0 mm (Cost of aluminium snap beading shall be paid in basic item): |
| 19 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 20 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 22 | CARRAIGESAND |
| 23 | STONE CHIPS |
| 24 | BRICKS |
| 25 | EARTH |
| 26 | Wiring for light point /fan point with1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recess PVC conduit ,piano type switch ,phenolic laminated sheet with suitable size PVC /MS box etc as required. |
| 27 | Supplying and fixing following way single pole and neutral,sheet steel MCB distribution board 240 volt on surface/recessed complete with tinned copper bus bar , neutral bus bar (without MCB) |
| 28 | Supplying and fixing 6 amp to 32 amp rating 240 volt 10 KACcurve miniature circuit breaker suitable for inductive load of following poles in existing MCB DB complete with connectionetc as required. |
| 29 | SITCof following rating surface mounted LED tube light fittingsuitable for 230 V 50 Hzsingle p[hase supply complete as required |
| 30 | 20/22 watt LED tube light |
| 31 | FRPVC Insulated 3 core 4 sq.mm copper wire |
| 32 | Labour welfare fund |
| 33 | GST @ 12 % |
AI Tender Summary
Tender Timeline
Aug 29, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 06, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender