}

Bids Are Invited For Implant-1 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be, Vadodara-Gujarat

Health And Family Welfare Department has published Bids Are Invited For Implant-1 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be. Submission Date for this Tender is 06-09-2022. Kitchen Equipment Tenders in Vadodara Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

33696960
Bids Are Invited For Implant-1 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be
Tender
Indian
Gujarat
Vadodara
06-09-2022

Tender Details

Bids Are Invited For Implant-1 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Right 4 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-2 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Right 6 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-3 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Right 8 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-4 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Right 10 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-5 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Right 12 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-6 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Right 14 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-7 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Left 6 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-8 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Left 8 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-9 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Left 10 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-10 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Left 12 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-11 3.5 Mm Distal Medial Tibia With Tab Desine Must Be Anatomically Contoured Plate Must Be Twested 20 Degree And Bent To Fit Indian Petiant Anatomy Limeted Contat Shaft Desing With Combi Hole 3 K Wire Holes Locking Hole Most Be In Parallel To The Joint In Distal Region Distal Tab For Optional Medial Malleolues Screws Size Left 14 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-12 2.4 Mm Extraarticular Volar Plate Are Precontoured For Anatomic Fit Of The Volar Aspect Of The Distal Radius So That Plate Placement Is Away Form The Articular Surface. Extraarticular Volar Distal Radius Plates Can Be Used For Simple Intraor Extraarticular Fracture. Diverging Screw Angles Secure The Radial Styloid And Other Distal Fragment Undercuts On The Bottom Of The 5 Hole Head Extraarticular Plates Facilitate Contouring Of The Plate To Match The Anatomy Of The Distal Radius And Minimize The Potential For Soft Issue Irritation Size Right 5 + 5 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-13 2.4 Mm Extraarticular Volar Plate Are Precontoured For Anatomic Fit Of The Volar Aspect Of The Distal Radius So That Plate Placement Is Away Form The Articular Surface. Extraarticular Volar Distal Radius Plates Can Be Used For Simple Intraor Extraarticular Fracture. Diverging Screw Angles Secure The Radial Styloid And Other Distal Fragment Undercuts On The Bottom Of The 5 Hole Head Extraarticular Plates Facilitate Contouring Of The Plate To Match The Anatomy Of The Distal Radius And Minimize The Potential For Soft Issue Irritation Size Left 5 + 5 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-14 2.4 Mm Extraarticular Volar Plate Are Precontoured For Anatomic Fit Of The Volar Aspect Of The Distal Radius So That Plate Placement Is Away Form The Articular Surface. Extraarticular Volar Distal Radius Plates Can Be Used For Simple Intraor Extraarticular Fracture. Diverging Screw Angles Secure The Radial Styloid And Other Distal Fragment Undercuts On The Bottom Of The 5 Hole Head Extraarticular Plates Facilitate Contouring Of The Plate To Match The Anatomy Of The Distal Radius And Minimize The Potential For Soft Issue Irritation Size Right 5 + 3 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-15 2.4 Mm Extraarticular Volar Plate Are Precontoured For Anatomic Fit Of The Volar Aspect Of The Distal Radius So That Plate Placement Is Away Form The Articular Surface. Extraarticular Volar Distal Radius Plates Can Be Used For Simple Intraor Extraarticular Fracture. Diverging Screw Angles Secure The Radial Styloid And Other Distal Fragment Undercuts On The Bottom Of The 5 Hole Head Extraarticular Plates Facilitate Contouring Of The Plate To Match The Anatomy Of The Distal Radius And Minimize The Potential For Soft Issue Irritation Size Left 5 + 3 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-16 2.4 Mm Extraarticular Volar Plate Are Precontoured For Anatomic Fit Of The Volar Aspect Of The Distal Radius So That Plate Placement Is Away Form The Articular Surface. Extraarticular Volar Distal Radius Plates Can Be Used For Simple Intraor Extraarticular Fracture. Diverging Screw Angles Secure The Radial Styloid And Other Distal Fragment Undercuts On The Bottom Of The 5 Hole Head Extraarticular Plates Facilitate Contouring Of The Plate To Match The Anatomy Of The Distal Radius And Minimize The Potential For Soft Issue Irritation Size Right 4 + 5 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-17 2.4 Mm Extraarticular Volar Plate Are Precontoured For Anatomic Fit Of The Volar Aspect Of The Distal Radius So That Plate Placement Is Away Form The Articular Surface. Extraarticular Volar Distal Radius Plates Can Be Used For Simple Intraor Extraarticular Fracture. Diverging Screw Angles Secure The Radial Styloid And Other Distal Fragment Undercuts On The Bottom Of The 5 Hole Head Extraarticular Plates Facilitate Contouring Of The Plate To Match The Anatomy Of The Distal Radius And Minimize The Potential For Soft Issue Irritation Size Left 4 + 5 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-18 2.4 Mm Extraarticular Volar Plate Are Precontoured For Anatomic Fit Of The Volar Aspect Of The Distal Radius So That Plate Placement Is Away Form The Articular Surface. Extraarticular Volar Distal Radius Plates Can Be Used For Simple Intraor Extraarticular Fracture. Diverging Screw Angles Secure The Radial Styloid And Other Distal Fragment Undercuts On The Bottom Of The 5 Hole Head Extraarticular Plates Facilitate Contouring Of The Plate To Match The Anatomy Of The Distal Radius And Minimize The Potential For Soft Issue Irritation Size Right 4 + 3 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-19 2.4 Mm Extraarticular Volar Plate Are Precontoured For Anatomic Fit Of The Volar Aspect Of The Distal Radius So That Plate Placement Is Away Form The Articular Surface. Extraarticular Volar Distal Radius Plates Can Be Used For Simple Intraor Extraarticular Fracture. Diverging Screw Angles Secure The Radial Styloid And Other Distal Fragment Undercuts On The Bottom Of The 5 Hole Head Extraarticular Plates Facilitate Contouring Of The Plate To Match The Anatomy Of The Distal Radius And Minimize The Potential For Soft Issue Irritation Size Left 4 + 3 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-20 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 6 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-21 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 7 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-22 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 8 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-23 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 9 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-24 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 10 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-25 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 11 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-26 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 12 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-27 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 13 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-28 4.5 Mm Low Contact Dynamic Compression Plate With Locking Combi Hole To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 14 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-29 4.5 Mm Low Contact Dynamic Compression Plate To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 7 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-30 4.5 Mm Low Contact Dynamic Compression Plate To Eliminate Reduced Impairment Of Periosteal Blood Flow To Avoid Shear Force Which Will Lead To Loss Of Reduction.Tapered Tip End On Both Side With K Wire Holes At Both Ends Opposite Direction Holes From The Centre. 8 Hole Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-31 Quick Bone Healing And Quick Setting Calcium Hydroxyapatite Injectable Cement Sets In 1020 Minutes.This Cement Acts As Osteoinductive Material And Promotes Bone Healing It Helps In Conduction Of New Bone Formation.This Cement Include With Dish Syringe Spatula And 14 Gauge Needle Provided With In The Packet Size 5 Gram Implant-32 Quick Bone Healing And Quick Setting Calcium Hydroxyapatite Injectable Cement Sets In 1020 Minutes.This Cement Acts As Osteoinductive Material And Promotes Bone Healing It Helps In Conduction Of New Bone Formation.This Cement Include With Dish Syringe Spatula And 14 Gauge Needle Provided With In The Packet Size 10 Gram Implant-33 3.5 Mm Ao Type Locking Head Screws 34 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-34 3.5 Mm Ao Type Locking Head Screws 36 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-35 3.5 Mm Ao Type Locking Head Screws 40 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-36 3.5 Mm Ao Type Locking Head Screws 42 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-37 3.5 Mm Ao Type Locking Head Screws 44 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufacturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-38 3.5 Mm Ao Type Locking Head Screws 46 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-39 3.5 Mm Ao Type Locking Head Screws 60 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-40 3.5 Mm Ao Type Locking Head Screws 65 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-41 3.5 Mm Ao Type Locking Head Screws 75 Mm 3.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail