Repair / Replacement Of Unsv Internal Wiring Electrical Fittings, Repairs Of Ceiling Fans / Exhaust Fans / Summer Appliances, Ac Plants And Day To Day Electrical Complaints In Dmrl, Rcma And Atc Davatallagutta At Kanchanbagh, Hyderabad, Hyderabad-Telangana

Military Engineer Services-MES has published Repair / Replacement Of Unsv Internal Wiring Electrical Fittings, Repairs Of Ceiling Fans / Exhaust Fans / Summer Appliances, Ac Plants And Day To Day Electrical Complaints In Dmrl, Rcma And Atc Davatallagutta At Kanchanbagh, Hyderabad. Submission Date for this Tender is 22-09-2022. Electrification Work Tenders in Hyderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

33694961
Corrigendum : Repair / Replacement Of Unsv Internal Wiring Electrical Fittings, Repairs Of Ceiling Fans / Exhaust Fans / Summer Appliances, Ac Plants And Day To Day Electrical Complaints In Dmrl, Rcma And Atc Davatallagutta At Kanchanbagh, Hyderabad
Open Tender
Indian
Telangana
Hyderabad
22-09-2022

Tender Details

Repair / Replacement Of Unsv Internal Wiring Electrical Fittings, Repairs Of Ceiling Fans / Exhaust Fans / Summer Appliances, Ac Plants And Day To Day Electrical Complaints In Dmrl, Rcma And Atc Davatallagutta At Kanchanbagh, Hyderabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 95620.0 /-
Tender Value
INR 47.80 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF UNSV INTERNAL WIRING ELECTRICAL FITTINGS, REPAIRSOF CEILING FANS/EXHAUST FANS/ SUMMER APPLIANCES, AC PLANTS AND DAY TO DAY ELECTRICAL COMPLAINTSIN DMRL,RCMA & ATC DAVATALLAGUTTA AT KANCHANBAGH, HYDERABAD.
Sl. No. Item Description
1Leak testing of the AC plant with nitrogen (N2) pressure after evacuating of the existing gas from the system into empty cylinder by separating the entire system, like compressors, evaporator, condensers, cooling coil and refrigerant lines and rectifying the leakage including cutting welding brazing etc and replacing of "O" ring, washers, gaskets etc flushing out the Nitrogen and vaccumising, recharging the taken out refrigerant gas including testing complete all as directed to AC plantsof capacity 2 x 11 TRAC plant at CAD CAM
2All as per item No. 1.00 here-in-before butof capacity 3 x 11 TR Central AC plant at Creep Lab
3All as per item No. 1.00 here-in-before butof capacity 3 x 30 TRAC plant at ETC
4All as per item No. 1.00 here-in-before butof capacity3 x 52 TR AC plant at AMG
5All as per item No. 1.00 here-in-before butof capacity 3 x 93TR AC plant at TIC. Note :- One condenser/Chiller unit shall be measured as one job for the purpose of payment.
6Supply only refrigerant gas R-22 complete all as directed
7Supply only refrigerant gasR-407c complete all as directed.
8Supply only refrigerant gasR-410 complete all as directed.
9Supply only refrigerant gasR-134a complete all as directed. Make Srl No 2 to 2.03: Mefron/Fluron/Freon
10Descaling of one condenser unit of following capacity of AC plantsof capacity 3x93TR central AC plant any make/type with and including descaling compound DC-96 by using Spiral brushing machine circulation with Magnetic pump for Impeller as required to remove complete scales from all copper tubes tillthe desired pressure is achieved including renewingof gaskets, nuts, bolts and washers Inlet & Outlet etc. and testing complete all as directed. Note: (i)Descaling Compound and Spiral Brushing Eqpt are deemed in quoted rate (ii)Descaling pump/spiral brushing eqpt produced by contractor are deemed in quoted rate . (iii) One condenser unit shall be measured as one job for the purpose of payment.
11All as per item No. 3.00 here-in-before but of capacity3 x 52TR Central AC plant at old Astra,Metrology Bldgs 124
12All as per item No. 3.00 here-in-before but of capacity3 x 30 TR central AC plant at Alignment metrology centre creep lab
13All as per item No. 3.00 here-in-before but of capacity3 x 11TR Central AC plant at Alignment inspection centre CAD CAM
14Taking out carefully the chiller electronic programmable logic control board of any capacity / make of the chiller unit after disconnecting all connection and taking the PLCB to the auth OEM service centre if necessary or repairing at site and testing the PLCB replacing the defective component of PLCB and testing the functioning of software and updating the software and code if necessary and refixing the same to its original position making all connections testing all parameter like the chillers loading , unloading suction / head pressure , all temperature logs but of capacities 11 to 30 TRAC plants complete to the entire satisfaction of Engr – In – Charge.
15All as per item No. 4.00here-in-before but of capacities 52 to 93TRAC plants.
16Removing the unserviceable V-Belts from the system and supply & Fix new V-Belts of ISI marked following sizes and testing and all as specified and directed, of sizesA-32 / A-39 / A-42/A-29 or as per site requirenment
17All as per item No. 5.00 above but of sizes B-81 / B-90 / B-92/ /B-68/B-63/B-93/B-88 or as per site requirenment/OEM
18All as per item No. 5.00 above but of sizes B-106/B-108/B-124/B-122/B-125/B-117 or as per site requirenment/OEM
19All as per item No. 5.00 above but of sizes C-110/C-90/C-108 or as per site requirenment/OEM
20Drainingout old compressor oil Lubricants , supply and filling new refrigeration compressor oilofflash point COC 210 Degree Celsius Min. Suitable for compressors working on refigerant R-22/R-407C/R-134A confirming IS 13256: 1992 or as per site requirnment complete all as directed by Engr-in-charge. Make : Servo press T68 or Hycom 150P or oil of Freezol-68/ freezol F-57 or as persite requirnment/OEM.
21Dismounting the centrifugal / mono block pumps of capacity upto 7.5 HP and shifting the pump to the workshop and replacing the damaged parts like impellers (ss) bearings, bushes and necessary spares and re-fixing to its original position for testing to the entire satisfaction of the Engr-in-Charge Note: the old U/S worn out parts should be displayed to Engr-in-Charge for testing the genuiness of repairs
22All as per item No. 7.00 as above but of capacity 12.5 HP to 15 HP.
23Supply and Fixing PVC Fins suitable to make of cooling tower MIHIR as required at site including nuts & bolts complete all as specified and directed.
24Disconnecting and taking out the existing old unserviceable water sensors and supply & fix new water sensor new anti freeze/ ambient air sensor of scroll compressor chillers of any capacity complete all as specified and testing as directed. Make: As per OEM
25Cleaning of the Evaporator coils/cooling tower finswithacid by force feed method to remove the unwanted dust particles formed on the coils/fins andcleaning of thedust particles cleaning of the filler, of any capacity make / model to the entire safisfaction of Engr-in-charge
26Servicing greasing overhauling of AHU blower motor Of any capacity, checking the pulleys, base frame, cooling to opening covers and replacing the bearings pulleys as per the existing model, lubricating all mechanical parts with synthetic grease and reassembling all parts, aligning of the pulley to its original position complete to the entire satisfaction of Engr-in Charge
27Supply & fix PVC spray nozzles of any dia flower type, (PVC pipe, bend, nipple as required sizes)suitable from 11 to93TR capacitycooling tower including removing the unserviceable sparay nozzles from site complete all as specified and directed by the Engr-in-Charge. Make - MIHIR/PAHARPUR/as PER OEM.
28Removing the existing unserviceable Oil pressure pump from the compressor, supply and fix new oil pressure pump of type as per the existing model / make and including replacing the valve plate gasket-3 No"s complete all as specified and directed of makeas per at site requirement.
29Disconnecting and removing the burnt out monoblock pumping sets from the existing plants, of central/package type AC plants, rewinding the same with supper enamelled copper conductor with same existing gauge and reconnecting the same with electrical connections and testing complete all as specified of capacity 5 HP to 7.5 HP.
30All as per item No. 14.00 above but of capacity 12 HP to 15 HP.
31Disconnecting and taking outthe repairablecentrifugal pumping setsfrom the existing plants of 20 HP to 30 HPcapacities ofcentral AC plants, replace the impeller, bearing, bush gasket sets, nut & bolts etc. of the same pumping setsincluding reinstallation the same plants, reconnecting the same with electrical connections and testingcomplete all as specified and as directed.
32Disconnecting and removing the unserviceable solenoid valve assembly and supply and fix the new solenoid assembly of MOP275 PSI, SWP 300PSI or as per site and reconnect the electrically and testing complete all as specified and directed. Make : Sporlon/Sanlan/Denfoss/OEM
33Taking out unserviceable water pressure cutout and supply and fix new water pressure cutout IPS 70. Make: INDFOSS/Danfoss or equivalent
34Taking out old unserviceable Pre filter and S & F Air pre filters suitable for HVAC Air conditioning system AHU’s as per norms made with galvanised steel frame aluminium separators with non woven synthetic filter media of 20 micron as per existing size and shape including taking down old U/S Air pre filters complete all as directed Make: As approved by GE
35Material and labour for taking out the damaged insulation portion of existing outdoor duct, cleaning the duct, applying two coats of CPRX compound to cleaned portion of duct, applying one coat of bitumen paint, fixing of 50mm thick glass wool of 48 KG density to the duct and sealing it with hessian cloth and 15 mm thick chicken wire mesh and 15mm thick sand cement plaster with cement mortor CM 1:4 to the duct and applying two coats of white wash and two coats of snow cem of existing color and site clearanceof old debris and making good all as specified and directed.
36Material and labour for taking out the damaged insulation portion of existing refrigerant line/chilled water pipe line of any size and cleaning the pipe and insulation with thermocole pipe section TF quality wrapped around pipe and fixing with GI wire mesh, with suitable aluminium cladding and site clearance of old debris all as specified and directed.
37M&L for painting the interior and exterior parts of cooling towers with epoxy seal paint as per the manufactures specifications including preparing the surfaces of cooling towers after removing all the PVC fill , nozzles, ID fan and cleaning the water collecting tray for algae free surfaces using necessary detergent chemicals complete sealing the leakage on the body if any while applying the epoxy sealing paint complete to the entire satisfaction of Engr-in-Charge.
38Removing the existing unserviceable fan blade assembly with hub from cooling tower and supply and fix new fan blade assembly with hub including clamp and fixing arrangement suitable for 11 to30TR capacity of exisiting make cooling tower complete all as specified and directed.
39All as per item No. 23 above but of 52 to93 TR capacity cooling tower complete all as specified and directed. Make : As per the existing make & model.
40Supply & Fix MCCB 3 Pole, 415 V, fixed type, 400 Amps with breaking capacity 36 KA , Icu=100% Ics, thermal magnetic, adjustable over load and short circuit ratings including spreaders links complete all as specified and directed. Make : L&T / Legrand / Schneider / Seimins
41Supply & Fix MCCB 4 Pole, 415 V, fixed type, 200 Amps with breaking capacity 36KA, Icu=100% Ics, thermal magnetic, adjustable over load and short circuit ratings including spreaders links complete all as specified and directed.
42Supply & Fix MCCB 4 Pole, 415 V, fixed type, 250 Amps with breaking capacity 36KA complete all as specified and directed.
43M&L for fixing the Aluminium composite panel3mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30 micron, cutting and pasting the vinyl letters as per the installation details given by the Site-In-Charge including fixing the board on the location specified with necessary fixing stainless steel bolts and washers. Make: As approved by the GE. Note: The sample piece of the panel should be produced for prior approval from GE before ordering. (ii) Working height upto 5mtrs deemed to be included in quoted rate.
44M&L for fabricating the base channel (ISI marked) frame work for the centrifigual monoblock pumps as per existing frame sizes thickness smooth and fixing to the PCC foundation using necessary bolts & nuts as required at site complete all as specified and directed.
45M&L for preparation of Base frame of any size and applying one coat of red oxide primer and two coats of black colour anti-corrosive paint complete all as specified and directed.
46Supply and replaceLP/HP cut out MP-15 Make: Sporlan/Sanlam.
47Supply and replace Oil pressure cut out MP-55, Make: Sporlan/Sanlam.
48Supply and replace Contactors ML-1.5 AC-3 type Make : L&T/GE)
49Supply and replace Contactors ML-1 AC-3 type Make :L&T/GE
50Supply and replace Contactors TC 1 D 5011 AC-3 type Make :Telemake/GE
51Supply and replace Three Pole contactor MN -16 Make : L&T/GE
52Supply and replace Three Pole contactor MN -25 Make : L&T/GE
53Supply and replace Single phase preventor suitable for 415V, AC, 50 Hz Make:-Minelec/GE.
54Supply and replace HRC fuse up to 50 amp with fuse holder as per existing panel Make:-FTC/GE.
55Supply and replace Thermal over load relay range 25 to 50 Amps suitable for MN type contactor, Make:-FTC/GE.
56Supply and replace Thermal over load relay range 9-25 Amps suitable for MN type contactor, Make: FTC/GE.
57Removing the existing unserviceable liquid line drier filter and supply & fix new liquid line drier filter for use with CFC/HCFC/HFC/R-22/R-134a/R-407c complete and key suitable for 11 TR AC plants, all as specified and directed.
58All as per item No. 32.00 above but of capacity 30TR AC plant.
59Taking out the unserviceable scroll/reciprocating compressor from the existing position and supply & fix new scroll/reciprocating compressor including initial filling up refrigerant gas as per manufacturer recommendation to the required pressure and reconnecting of all connected system complete all as directed by the Engr-in-Charge, of capacity 5.5 TR to 6 TR,.
60M&L in replacement of scroll type compressor unit suitable for 12 TR package type plant, compatiable to R-22/R-134a refrigerent, thermally protected, Max system test pressure low/high side: 25 bar(g)/31.9 bar (g), Maximum differential test pressure : 28 bar, 3 phase, with working voltage of 460-400V+10%, 50 Hz, full laod amp 35A, nomial flow rate : 43.4 m3h, RPM : 2900 tr/Min complete with all necessary fittings, including dismantling existing unserviceable compressor and seperate from existing refrigerant & electrical line, including brazing, leak testing, cable connections with lugs complete all as directed Make: Denfoss/Indfoss/Kirloskar
61Supply & fix in replacementthe sign board of Main pump house/ Main receiving station 33/11KV /Sub station 01/ sub station No 02 of GE(I) R&D kanchanbagh, Military Engineer Services with LOGO of (MES) sign Board Details: 3.5ft x5.5ft ACP Panel (aluminium composite panel) 3mm thickness white colour or grey colour.acrylic letters will fix on panel.letters in Acrylic 6mm or 8mm thickness computerised script CNC laser cutting letters in imported Acrylic.
62Disconnecting and removing the unserviceable Suction expansion valve assembly and supply and fix the new expansion valve assembly of 11TR capacity AC plants and reconnect the same with existing plants and testing complete all as specified and directed
63All as item No. 36.00 as above but of capacity 30 TR AC plant.
64All as per item No. 36.00 above but of cap52 TR Central AC plant.
65All as per item No. 36.00 above but of cap 93 TRAC plant. Make of item No. 36.00 to 39.00 : Sporlan/Sanlam or its equivallent.
66Supplying, laying in replacing steel /cast/GI/PP-R pipes of following sizes and including cutting of CI/GI pipe line complete all as per specified and as directed by Engr-in-charge.
67160 mm dia.
68110 mm dia.
6990 mm dia.
7050 mm dia.
7125 mm dia.
72Removing the existing unserviceable butterfly valve of any size and supply and fix butterfly valve of following sizes including replacing of nuts, bolts, washers and packing and testing all as specified and directed. Make-Kirloskar/Kartar/upadyaya.
7350-60 mm dia.
74100 mm dia.
75150mm dia.
76Supply and Fix Ammeter digital type with selector switches suitable for LT panel of AC plantscomplete including removing of old unserviceable ammeter complete all as specified and directed. Make :- AE/L&T/Kappa/HPL
77Supply and Fix Voltmeter digital type with selector switches suitable for LT panel of AC plants complete including removing of old unserviceable ammeter complete all as specified and directed. Make :- AE/L&T/Kappa/HPL
78Supply and Fix indicator lamps LED type 110 Volts for LT panels including removing of the unserviceable complete all as specified and directed. Make :- L&T/Alstom/Siemens
79Supply and Fixing the dial type Pressure Gauges in the Chiller & AHU water pipe line complete with all fittings and gun metal valves for isolation for ease of maintenance and operation all as per manufacturer design / as per site requirenment complete all as specified and asdirected. Make: H Guru/ as per site conditions.
80Supply and Fixing the dial type Temperature Gauges of size 100 mm dia in the Chiller & AHU water pipe line complete with all fittings and gun metal valves for isolation for ease of maintenance and operation all as per manufacturer design complete all as specified and asdirected. Make: H Guru/ as per site conditions.
81All as per Sl item No.51 above but 80 mm dia complete all as specified and asdirected.
82Removing the existing un serviceable gate valve and supply and fix new PP-R gate valves with necessary PP-R fittings of the following sizes :- MAKE : Leader/Zoloto/Bir/Kirloskar
83a) 25 mm dia
84b) 32 mm dia
85c) 50 mm dia
86d) 63 mm dia
87Removing the existing unserviceable butterfly valve of any size and supply and fix PP-R butterfly valve of following sizes including replacing of nuts, bolts, washers and packing and testing all as specified and directed. Make :- Kirloskar/L&T/AUDCO/Normax
88a) 50 mm dia.
89b) 63 mm dia.
90Removing, shifitng, fixing at new location testing complete ofthe exisiting unserviceable any type FRP cooling tower clean it complete by replacing all the fins with new fins , choked nozzel/spray section honey comb fill including secviing/any repair required to make it fully functional basin fan andTEFC motor, intake bird screen and shifing it to another loaction and other accessories along with all inlet and outlet water connection and electical connectionas requiredon site with and including provision of suitablesize brick work staging with PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation and excavation to the required size in any strata, Provision of ladder etc and including PVC Fins as required qty deemed in the quoted rate complete all as specified and directed. Note : (i) Inlet and outlet pipes with control valves from nearest tapping point for cooling towerand electical cables for connetion shall be deemed to be included in rate quoted.
91Supply and fix in repelcement of existing unserviceable outdoor unit of split type AC of 1.5 TR capacity with compressor , copper condensor coil, fan motor etccomplete Make :- Hitachi, Comipro,Godrej, Carrier, LG
92Supply and fix in repelcement of existing unserviceable outdoor unit of split type AC of 2.0 TR capacity with compressor , copper condensor coil, fan motor etccomplete Make :- Hitachi, Comipro,Godrij, Carrier, LG
93S & F in repair Starting Relay for 2.0/1.5 Ton capacity Window/Split type AC"s all as directed by Engr-in-charge.
94S & F in repair Overload protector SR 1622 forWindow/Split type AC"s all as directed by Engr-in-charge.
95S & F in repair Starting capacitor of 80 to 100 MFDforWindow/Split type AC"s all as directed by Engr-in-charge. Make:- Havells/ Tibcon/Jairic
96S & F in repair Starting capacitor of 100 to 120 MFDforWindow/Split type AC"s all as directed by Engr-in-charge.
97S & F in repair Running capacitor of 36 MFDforWindow/Split type AC"s all as directed by Engr-in-charge.
98S & F in repair Running capacitor of 45 MFDforWindow/Split type AC"s all as directed by Engr-in-charge.
99S & F in repair Thermostatic switch forWindow/Split type AC"s all as directed by Engr-in-charge.
100S & F in repair Selector switch of rotary type forWindow/Split type AC"s all as directed by Engr-in-charge.
101S & F in repair of doule shaft Blower fan motor suitable for 1.5/2.0 Ton capacity Window AC"s complete Make :- AUE or any ISI marked
102S & F in repair of Fan blade for 1.5/2Ton capacity Split type AC as per existing make and model
103S & F in repair of Air filter for window/split type AC 1.5/2 Ton as per existing make and model
104S & F in repair of Front grill for window type AC as existing make and model
105Taking down carefully old burnt/unserviceable rotary compressor unit of 1.5 ton capacityand replacing the same with rotarycompressor (i.e as per site requirenment) including necessary accessories i e capillary tube including strainer and mounting materials,etc, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete to any make of AC all as directed by Engr-in-charge.
106All as per Item No-70 here-in-before but of 2.0 Ton capacity reciprocation compressor complete all as directed
107All as per Item No-70 here-in-before but of 3.0 Ton reciprocation compressorcomplete all as directed
108Supply and fix in replacement GEYSER WATER TANK of Stainless steel of shape required as per site suitable for 25 lts geyser complete
109Supply and fix in replacement rusted/UNSVexhaust fan louvers of existing 300/450mm exhaust fans
110Cleaning the unit with CTC except evaporator and condensor and leak testing the system with CO2 gas and detecting the leak and repairing, brazing and sealing the leakage including charging the refrigerant R-22 gas to the required pressure and weight of gas for 1.5/2.0 Ton capacity window/split type AC of any make complete all as directed
111All as per Item No-75 here-in-before but of3.0(Multi unit)/5.0 Ton capacity window/split type AC. Note for item No 75 & 76:- Gas charging will be measured against relevant item of this schedule.
112Servicing and overhauling the 1.5/2.0/3.0 Ton capacity (Window/Split) AC with water, chemical air clearner, filter and drying, checking the bolt and nut connections, filling, refixing /shifting/electrical loose connections and testing complete all as directed
113S & Fevaporating coil made out of 25 SWG copper tubing having 30/34G aluminium fins per length for window AC"s of 1.5/2.0 Ton capacity including taking out the Unsv evaporating coil complete all as directed
114S & Fcondensor coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length for window AC"s of 1.5/2.0 Ton capacity indlcuding taking outthe Unsv condensor coil complete all as directed
115S & F Indoor unit of Split type AC of 1.5 TR capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as directedMake - DAIKIN /GODREJ/CAMIPRO/CARRIER
116All as per Item No-80 above but forSplit AC 2.0 TR capacity complete
117Dismantling the water cooler and repairing the body by welding, brazing, riveting where required and making good of stand and bottom portion painting the body on external surfaces with two coats of synthetic enamel paint over a coat of primer of same colour by machine spray and reassembling and installing in original position and testing complete all as directed
118Cleaning all the parts, condensor unit and capillary tubes and checkng the leakage of gas with CO2 and brazing, rectifying the leakge, including charging the refrigerant gas to required pressure and weight fixing back to the original positon, testing comissioning complete for any make and any capacity of water cooler complete all as directed .
119S & F inrepairs Relay Assembly for 40/80 Ltrs capacity Water Coolers of any make complete all as directed
120S & F inrepairsThermostatic Switch for 40/80 Ltrs capacity Water Coolers of any make complete all as directed
121S & F inrepairscopper wounded condenser fan Motor Single phase, 230V for 40/80 Ltrs capacity Water Coolers of any make complete all as directed
122S & F inrepairs Fan motor blade of existing size and model for 40/80 Ltrs capacity Water Coolers of any make complete all as directed .
123S & F inrepairs Float valve 15 MM bore with brass spindle and PVC ball complete for 40/80 Ltrs capacity Water Coolers of any make complete all as directed Make- PRAYAG
124S & F inrepairs Push/lift tap 15 mm bore chromium plated for 40/80 Ltrs capacity Water Coolers of any make complete all as directed Make- JAISON
125S & F inrepairs Overload protector 1022/522, for 40/80 Ltrs capacity Water Coolers of any make complete all as directed
126S & F inrepairs Starting/running Capacitor 60/80 Mfd, for 40/80 Ltrs capacity Water Coolers of any make complete all as directed
127Removing of defective condenser fan motor from water cooler rewinding of fan motor with same gauge and turns and weight of copper enamelled wire and replacement of bearing and refixing, testing and commissioning of water coolers of any make complete all as directed
128Taking out old burnt/unserviceable compressor unit ofwater cooler and repalcing the same with newcompressor of existing unit includingnecessary nuts, bolts, mounting materials, welding, brazing, leak testing and charging the refrigerant gas, R-22to the required pressure and weight, reinstalling in the same place including servicing, testing and commissioning for 40/60/80 Litre Capacity water coolercomplete to any make of water cooler all as directed.
129All as per Item Ser No 93 here-in-before but for 100/120 Litre Capacity water cooler.
130S & F in drain tray and PVC flexible pipe and connecting to inlet pipe for 40/60/80 ltrs capacity of water cooler, including holdingclamps complete all as directed
131Servicing the water cooler of any make including cleaning the water tank, and the side body by washing, rubbing down including removing all the dust, dirt complete all as directed
132S & F inrepairs submersiable water pump motor as per existing capacity complete for desert coolers of any make complete Make:- khaitan/Crompton.
133Renewal of Fan motor of desert cooler single phase, 215 Volts, AC, 50 Hz complete for desert coolers of any make complete for capacity 3000/4000 CUM. Make- C&G/BAJAJ/AUE
134S & F inrepairs Fan blade of desert cooler Metallic/PVC as per existing model complete for desert coolers of any make complete for capacity 3000/4000 CUM.
135S & F inrepairs KHAS-KHAS grass (One set of three) as approved by Engr-in-charge, complete for desert coolers of any make complete for capacity 3000/4000 CUM.
136S & F inrepairs PVC water tube and distribution with 3 way PVC connection,PVC bends assembly complete, for desert coolers of any make complete
137S & F inrepairs Caster wheels (Set of Four) complete, for desert coolers of any make complete for capacity 3000/4000 CUM.
138S&F in repairs front grill of desert cooler of capacity 3000/4000 Cum of any make complete all as directed
139S&F in repairs switch assemblyfor desert coolers of capacity 3000/4000 Cum of any make complete all as directed.
140S&F in repairs Capacitor of 4/5 MFD capacity suitable for fan motor of desert coolers of capacity 3000/4000 CFM of any make complete all as directed.
141M&L for wiring to desert coolers with PVC insulated multistranded, copper conductor single core of size 1.5 Sqmm including PVC clamps, brackets as required and connection, water pump, control switches including taking down old wiring complete all as directed.
142Supply and fix in repairs connection wire of 3 core copper wire PVC insulated of size 4 Sqmm for any capacity window type/Split type AC, water coolers/desert coolers complete all as directed. Make- FINECAB/HAVELLS/FINOLEX
143S&F in repairs plug top 3 pin 5 Amps for desert cooler/water coolers/refrigerator complete all as directed.
144S&F in repairs 3 pin industrial plug top suitable for industrial metal clad socket, single phase, 230 Volts, AC including reconnecting complete all as directed. Make- LEGRAND/Havells/C&S
145S&F in repairs copper tube of size 3/8" / 5/8" dia includng necessary soldering, flaring and connecting and testing in between indoor to out door units of split type AC 1.5 Ton complete all as directed.
146All as per Item No 110 here-in-before but size of copper tubing 1/2" / 1/4" dia complete all as directed.
147S&F in repairs nitrele rubber insulation pipes of suitable size for suction (discharge pipe) felt for split type AC 1.5 / 2.0/3.0 Ton copper tube as in inlet/outlet to out door unit complete all as directed.
148S & Fix in repairs remote control assembly set suitable for split type AC 1.5 / 2.0/3.0 Ton capacity of any make complete all as directed.
149S&F in repairs indoor blower motor for split type AC as per existing model, sample complete all as directed
150Taking down carefully existing serviceable split type AC unit of 1.5/2.0 TR capacity and shiftting to in another location and refixing in any position and height complete with all connected work like making holes, fixing mounting bracketsand all other requiredaccessories including making good the distrubed surfaces complete all as direcrted. Note :- Quoted rates are deemed to be included necessory core cutting on walls and making good existing walls etc.
151S&F in repairs capillary tube including strainer suitable for split type AC 1.5/2.0 TR capacity with necessary brazing, leak testing complete all as directed.
152S&F in repairs voltage stabilizer single phase, 230 Volts, AC, 50 Hz of capacity 4 KVA wall mounting typewindow type AC with low and high cut off and intelligent delay input voltage 160 Volts to 260 Volts complete all as directed.
153All as per Item No-117 here-in-before but 5 KVA capacity voltage stabilizer complete all as directed. Make for Item Nos. 117 & 118 :- "V" GUARD/ VOLINA/Vinitec
154Repairs to stabilizer of 4KVA/5KVA capacity of Transformer including spares parts as required functional testing & reinstallaing after necessary repairs complete all as directed.
155Taking out unserviceable 1 Pole contactor from the split type AC and replacing the same asexistingwith new contactor suitable for 240V, 50Hz coil complete all as directed.
156S&F in repairs 2 Pole contactor from the split type AC and replacing the same with new contactor suitable for 240V, 50Hz coil complete all as directed.
157S&F in repairs drain pipefrom AC units complete all as directed.
158S&F Brass Valves (set of 2 Nos) suitable for split type AC of capacity 1.5/2TR as per existig type including necessary brazing and sealing the leakage, Leak testing , charging the Refrigerant gas up to required pressure including taking down the unserviceable brass valves complete all as directed. Note :- Gas charging will be measured and paid under relevant item of this schedule.
159S&F in repairs wall mounting brackets made out of steel ( set of 02Nos) powder coated factory made suitable for mounting outdoor unit of Split ACup to 2.0 TRcapacity including all Fixing fastnery and making good to disturbed surface of wall
160Taking out carefully the chiller electronic programmable logic control board of any capacity / make of the chiller unit after disconnecting all connection and S & F newPLCB from thethe auth OEM service centre and testing the functioning of software and updating the software and code if necessary and fix toitsposition making all connections testing all parameter like the chillers loading , unloading suction / head pressure , all temperature logs but of capacities 11 to 30 TRAC plants complete to the entire satisfaction of Engr – In – Charge.
161All as per item No. 127 here-in-before but of capacities 52 to 93TRAC plants.
162S&F in repairs of 3 pole, 415 volts 50 Hz power contractors of MNX 40 Contactor
163S&F in repairs of 3 pole, 415 volts 50 Hz power contractors of MNX 45 Contactor Make for item Nos.125 to 128 - L&T/ SEMENS /LEGRAND/ SCHNEIDER
164S&F in repairs Copper Cable single Core, PVC insulated, multistranded 35 Sqmm with suitable size lugs on both side.
165Servicing of all grills installed at PM Plant,DMRLby water wash/Air wash to provide proper cooling inside the process areacomplete all as directed.
166Dismantling the 3HP to 5HP capacity Motor of condenser / Blower/ Pump / Chiller/ AHU / Cooling Tower Motor from installed position, and rewinding the same with super enamelled copper wire of same gauge and turns as per existing, replacement of wornout Bearingsfixing back, testing and commissioning complete all as directed.Note : Transportation charges demed to be also included in quoted rate
167All as per serial item No. 131 here-in-before but for7.5 HP to 10 HP capacity
168All as per serial item No. 131 here-in-before but for 20 HPto 25 HP capacity
169Supply & layingMS pipe 125 to 150 mm diamedium grade, including providing Specials, Flanges, Elbows, Tees, Unions, Nipples, Nuts & Bolts, Gasket etc wherever necessary as per site requirement by necessary Fabrication / Fixing etc., and painting to match with the existing including taking down old pipes complete all as directed. Make:-TATA/JINDAL/ZENITH
170All as per item No.134 here-in-beforebut for 80 to 100 mm dia MS Pipe.
171S&F in repairs of freezing temparature sensor with under voltage 180 to 234 volts and over voltage 246 to 300 volts AC, complete all as directed.
172Taking down carefully of any type point wiring light fans socket or power complete fitting such as switch ceiling roses, pendent, regulator, sockets etc removing material and making good disturb surface of wall floor etc complete all as directed.
173Material and labour for point wiring complete with ISI marked1.5 SqmmPVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:- One light/ fan point controlled by one, one way switch
174All as per srl Item No. 138 here-in-before but for One ceiling fan/exhaust fan point controlled by one way switch 6 Amps.
175All as per srl Item No. 138 here-in-before but for one bell point controlled by one bell push 6 amps.
176All as per srl Item No. 138 here-in-before but for Switch Socket outlet 2/3 pins 6 Ampson independent board.
177All as per srl Item No. 138 here-in-before but for Switch Socket outlet 2/3 pins 6 Amps on same board.
178Material and labour for point wiring complete with ISI marked 4 SqmmPVC insulated unsheathed multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 4 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified including taking down old point wiring complete as directed.
179S&F in repairs switch piano one way 5 Amps 240 Volt complete all as directed. Make: cona/anchor/GM
180S&F in repairs switch socket outlet 3 pin,5 Amps 240 Volt complete all as directed. Make: cona/anchor/GM
181S&F in repairs switch socket combination 5 pin 15 Amps multipurpose type complete all as directed. Make: cona/anchor/GM
182S&F in repairs Bell push flush type 5 Amps complete all as directed. Make: cona/anchor/GM
183S&F in repairs lamp holder angle/ batten type complete all as directed. Make: cona/anchor/GM
184S&F in repairs fan regulator 240 V AC electronic step type complete all as directed. Make: cona/anchor/leader
185S&F in repairs modular fan regulator 120watt 240 V AC two module type complete all as directed. Make: cona/anchor/leader
186S&F in replacement for ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body.
187S&F in repairs modular Socket 6A-2/3 pin combined two module typecomplete all as directed. Make: Legrand/Indo-Asian/L&T
188S&F in repairs modular Socket 6A/16A-2/3 pin combined two module type complete all as directed. Make: Legrand Britzy/Indo-Asian/L&T
189S&F in repairs modular 1 way 6Amp switch 1 module complete all as directed. Make: Legrand/ Indo-Asian/L&T
190S&F in repairs 1 way 15 Amp switch 1 module complete all as directed. Make:Legrand/ Indo-Asian/L&T
191S&F in repairs Piano switch 2 way 15 amps1 module complete all as directed. Make: cona/anchor/leader
192S&F in repairs bell ding dong, AC, 230V, single pole complete all as directed. Make: cona/anchor/leader
193S&F LED Highbayluminaire 120Watt , 220V AC, dia 285mm IP 66 fittingwith high efficiency with LED efficacy of 100 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete. Make :Crompton Cat part: LHB11-120-CDL/60-M or equivalent inShakti/ Havells
194S&F LED luminaire 1ftx4ft33/36/40 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare light with LED efficacy of not less than 100 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete. Make :Crompton Cat part: LCTSNE-40TL or equivalent inShakti/ Havells
195S&F LED luminaire 600 mm x 600 mm 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete. Make : Crompton Cat part: LCTRNE-36 FO TL or equivalent in Jaquar/ Shakti/ Havells
196S&F in repairs post top lantern LED type 40 watt 230 watts volts AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp along withnecessary wiring,accessroies complete all as directed. Make : Crompton Cat part: LPTO-40-CDL or equivalent in Jaquar/ Shakti/ Havell"s
197S&F in replacment LED polycarbonate tube rod retrofit 18Watt, 6500K CCT,proffesional luminaries single side connection with < 10% THD. Make: HavellsCatpart :PHOTONULTRA2.01213T8SSTL18WLED865SPC or equivalent in Philips/ Wipro/ Shakti/ Havell"s
198S&F in replacment LED polycarbonate tuberod 22Watt, 6500K CCT,proffesional luminaries single side connection with < 10% THD. Make:HavellsCatpart :PHOTONULTRA2.01213T8SSTL20WLED865SPC or equivalent in Philips/Wipro
199S&F in replacment indoor industrial type surface/wall mounted LED integral batten 20 W, 6500K CCT, alluminium extruded body and polycarbonate diffuser, <10%THD, integral elctronic drivercomplete fixing with all accessories prewired and includingconnectingup with three coreflexible copper conductorcablewith suitable size complete removingunserviceable fittings all as specified and directed. Make : Havells Cat part: LUMILINE+BS18WLED865SPCSS or equivalent in Philips/Wipro/Shakti
200S&F in replacment indoor industrial type surface/wall mounted LED integral batten 10W, 6500K CCT, alluminium extruded body and polycarbonate diffuser, <10%THD, integral elctronic drivercomplete fixing with all accessories prewired and includingconnectingup with three coreflexible copper conductorcablewith suitable size complete removingunserviceable fittings all as specified and directed. Make : Havells Cat part: LUMILINE+BS10WLED865SPCSS or equivalent in Philips/Wipro/Shakti
201Dismantling and taking down Geyser of 25/50 litres capacity of any make and pattern from the existing position and removing bolts and nuts, opening and taking out all internal unserviceable parts, leak testing of the inner container, refixing the same in original position after necessary repairscomplete all as directed. Note:- Replacement of unserviceable parts will be measured and paid separately under relevant items of this BOQ.
202S&F in repairs geyser element of any type and model for 25/50 litres capacity for the 1500 WISI marked complete all as directed.
203S&F in repairs thermostat of the geyser, 15 Amps and temperature of 70º C complete all as directed. Make:-REMSON/ POWER PACK/Warmex/AO SMITH
204S&F in repairs PVC connection with metal fabricated outerconnection for geyser, of best quality 15mm dia, 600mm long with union, brass nuts and washers for hot water pipe for outlet connection complete all as directed. Make : KOHINOOR/ MAHAVIR/ PRAYAG (SYMET)
205S&F in repairs copper cable of size 3 core 2.5 Sqmm, PVC insulated sheathed, multistranded copper conductor complete all as directed. Make:-HAVELLS/FINOLEX/ FINECAB/ ANCHOR
206Material and Labour for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof,floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire includingtaking downunserviceable sub main wiring including conduitall as specified and directed. Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.
207All as per srl item No.171 here-in-before but with 2 runs 6 sqmmincluding 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia PVC conduit. Note : 2 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment.
208S&F in repairs non metallic PVC conduit 20 mm dia inclusive of boxestees, bends, elbows, reducers, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as directed. Make- Sudhakar/Avon/Finolex
209Supply and fix in replacement MCB DB 12 way SPN (double door)sheet metal enclosure factory made suitable for MCB DB"s 240 voltswith 200 Amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/Havells
210Supply and fix in replacement MCB DB 08 way SPN (double door)sheet metal enclosure factory made suitable for MCB DB"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Make: Legrand/ Schneider/L&T/Havells
211Supply and fix in replacement MCB TPN DB 04 way(double door)sheet metal enclosure factory made suitable for MCB TPN incomer and MCBs as outgoingwith 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make :Legrand/L&T/Havells
212Supply and fix in replacement of MCB single pole 6-32 Amps working on 240 volts, 50 HZ AC, 10 KA "C" curve all as specified and directed. Make: Legrand/Havells/L&T
213S&F in replacement of MCB SPN 32-40 Amps working on 240 volts, 50 HZ AC, 10 KA "C" curveall as specified and directed. Make: Legrand/Havells/L&T
214Supply & fixingof MCB TP 40 Amps complete 415 V 50 Hz,10 KA "C" curve including taking down old un serviceable isolators complete all as directed. Make- L&T/Legrand/Havells
215Supply & fixingof MCB 4 pole operating on 415V, AC supply of capacity 63-100 Amps ,10 KA "C" curve including taking down old existing un serviceable isolators complete all as directed. Make- L&T/Legrand/Havells
216S&F in repairs metallic AC earth plug and socket with sheet metal enclosure with MCB SP 20A complete all as directed. Make: L&T/Legrand/Schnieder/Havells
217S&FMCCB 100 Amps, 3/4 pole, 16KA, 415 Volts, 50 HZ, Icu=100%Ics thermal magnetic fixed olc and short circuit rating including necessary fixing arrangement for fixing of MCCB to the existing panel, connecting cable connectionsincluding taking down old unserviceable MCCB complete all as directed. Make: L&T/Legrand/Schnieder
218Taking down ceiling fan/exhaust fan/ wall mounted fan / Air circulator fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as directed. Note :1. Cost of spares such as capacitors, bearings, Shaft etc will be measured and paid for separately under respective Item of sch A as supply only.
219Supply only capacitor 2.5 mfd suitable for ceiling fan and testing complete all as directed. Make: Epcos/Havells/Tibcon
220Supply only capacitor 3.5/ 4.0 mfd suitable for Exhaust fan/Wall mounted fan/Air Circulator Fan . Make: Epcos/Havells/Tibcon
221Disconnecting electric connectionand taking down carefullyfan of any type and size/sweep as described below, removing the burnt winding of fan motor and cleaning the stator completly removing the burnt sludges from the slots andrewinding with super enameled copper winding wire of suitable gauge of matching size to the exisiting wires with same turns ratio including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and refixing to original position all as directed by Engineer-in-charge. Note:- The contractor shall assemble the rewinded stator core only after submitting the sample rewinded core for approval.
222Celling fan of size 1200/1400mm sweep.
223Wall mounted/Pedstal fans size 350/450 mm sweep Oscillating.
224Exhaust fan of 350/450 mm sweep.
225Supply and fix bearing No.6201/6202/6203/6204 or any other No matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan including disconnecting electric connectionand taking down fan and refixing in original position. Make: SKF/TATA/ARB
226Preparation of old surface of exhaust fan of any sweep by removing old paint using paint remover or by burning off using blow lamp and cleaning with cloth and Spray painting complete exhaust fan with superior quality synthetic enamel paint (Smoke grey) after applying a single coat of primercomplete all as directed.
227All as per item no 188 above but Ceiling fan of size 1200/1400 mm sweep with superior quality enamel paint ( Half White) complete all as directed.
228S&F PVC rectangular block for mounting, switches, sockets,PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep for fan regulator etc. including removing of old unserviceable sheet complete all as directed.
229All as per srl item No. 190 here-in-before but of 175mm x 100mm size
230All as per srl item No. 190 here-in-before but of 250mm x 300 mm size
231Supplying and fixing 1100 volts grade heavy duty cable PVC insulated standard aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable of size 6 sqmm flat or circular complete all as specified and directed. Make : Havells/Finolex/Plaza
232M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge.
233All as per item No. 194 but using galvanised iron strip 25x4mm as earthing lead
234S&F GI earth wire 4 mm dia on walls/flooras earth continuity conductor connected to DBs/ panels etc.
235All as per item No. 196but using galvanised iron strip 25x4mm
236Supply and Fix GI tubing 15mm dia light grade for protection of GI earth wire complete all as specified and directed.
237Supply and fix in replacement SS geyser assembly as per existing size/shape it may be 6 hole/9 hole or without to make the geyser fully funtional complete.
238Supply and fix in replacement MCB DB 04 way SPN (double door)sheet metal enclosure factory made suitable for MCB DB"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as required at site and as directed . Make: Legrand/ Schneider/L&T/Havells