| 1 | BOQ ( Sch A ) Supply and fixing LED Streetlight 30 Wattmade up of pressure die cast housing with toughend glass. Fitting will be fitted with32/40 mm dia GI pipe light grade bracket 1.2 mtr long fixed on pole, bent to shape as required with and including suitable size MS clamp,nuts, bolts and washers and making connection with using 2.5 sqmm PVC insulated multistranded copper conductor two single core cable from LT over head line/connection boxes. Make of light fitting HavellsPhilips, HPL, Surya, Crompton etc complete all as specified and directed |
| 2 | Supplying, laying, jointing and commissioning of LT XLPE 1100 volts 16 sqmm 4 coregrade heavy duty under ground cable PVC insulated,strandred aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, in floor through pipes, in ductor on pole and roads etc.complete all as specified and directed. |
| 3 | All as per item No 2 above but size of LT XLPE cable 240 Sqmm3.5 core |
| 4 | All as per item No 2 above but size of LT XLPE cable 150 Sqmm3.5 core |
| 5 | All as per item No 2 above but size of LT XLPE cable 120 Sqmm3.5 core |
| 6 | All as per item No 2 above but size of LT XLPE cable 95 Sqmm3.5 core |
| 7 | All as per item No 2 above but size of LT XLPE cable 50 Sqmm3.5 core |
| 8 | All as per item No 2 above but size of LT XLPE cable 35 Sqmm3.5 core |
| 9 | All as per item No 2 above but size of LT XLPE cable 25 Sqmm 4 core |
| 10 | All as per item No 2 above but size of LT XLPE cable 16 Sqmm 2 core |
| 11 | Excavation in trenches in hard/dense soil not exc 1.5mtrs wide and not exc. 1.5m in depth for laying cables and getting out includingjointing bottom surface to the reqd level/slope etc complete all as specified and directed. |
| 12 | Returnin, fillingin, including spreading, leveling,watering and well ramming in layers not exc 25 cm thick in hard/dense soil complete all as specified and directed. |
| 13 | Removing excavated material (soil) to a distance not exc 50 mtr and deposited where directed at a level not exc 1.5 mtrs above the starting pointcomplete all as specified and directed. |
| 14 | Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed.Note : Punned down thickness of sand shall be considered for measurement and payment. |
| 15 | Material and labour for brick protection to cable using old size class \"B\" bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified and directed. |
| 16 | M&L for 25mm bore GI pipe light grade with and includning all GI fittings as in protection pipe for cable fixed to pole or laid in trenches/ floor for mechanical of protection of cable complete all as specified and directed. |
| 17 | M&L for 80mm bore GI pipe light grade with and includning all GI fittings as in protection pipe for cable fixed to pole or laid in trenches/ floor for mechanical of protection of cable complete all as specified and directed. |
| 18 | M&L for 50mm bore GI pipe light grade with and includning all GI fittings as in protection pipe for cable fixed to pole or laid in trenches/ floor for mechanical of protection of cable complete all as specified and directed. |
| 19 | M&L for 40mm bore GI pipe light grade with and includning all GI fittings as in protection pipe for cable fixed to pole or laid in trenches/ floor for mechanical of protection of cable complete all as specified and directed. |
| 20 | S & F Non Transparent SMC Kiosks box with1 No, 10 Amp MCB for controlling of street light with and including providing standerd sizeclamp complete all as specified and directed. |
| 21 | M & L for supply, transporting, erecting truly in vertical position and fixing of steel tubular pole swaged, over all length 9 metres, type 410 – SP – 31 complete with mild steel base plate, pole cap, finial taper plug, MS bolts, nuts & washers, necessary excavation & earthworkin hard / dense soil, PCC sub base block as mass concrete of size 600 X 600 X 150 mm in cement concrete 1:4:8 Type D-2 in base of foundation, PCC foundation block of size 600 X 600 X 1500 mm in cement concrete 1:3:6 Type C-2, pole plinth of size 600 X 600 X 300 mm in cement concrete 1:2:4 Type B-1 including necessary form work as required at site and painting of pole with two coats of anti corrosive black bituminous paint through out internally and externally upto planting depth (embedded in concrete) and remaining portion of the pole painted with two coats of aluminium paint over a coat of red oxide primer on complete exposed surface including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed. |
| 22 | M&L for earthing complete with galvanised steel,earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs belowground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 Part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil, common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in RCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 mm c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handleto cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode, GI pipe to be fixed with complete all as specified and directed.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost at his own expances by the contractor. |
| 23 | M&L for earthing complete with galvanised steel,earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs belowground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised strip 32x6mm as earth leadby means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 mm c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handleto cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost at his own expances by the contractor. |
| 24 | S & F on pole / wall Nature switch02 EC with enclosure factory made suitable for 8 KW street light load single phase 240 volts and power contactor rating 40 Amp with MCB 63 Amp contactor and terminal block confirming to IEC – 60947 – 4 – 1 / IS – 13947 – 4 – 1 (Sensor alongwith pre-dawn switching off timer, 4 – 8 hours) infrared sensor based switch for intelligent outdoor street light control model No. SWADEEP – 02EC8kW1P, Make – KAKATIYA ENERGY SYSTEMS LTD/ Havells/Indo Asian/L&T complete with and including mounting bracket, cable glands, openable doors with lock complete all as specified and directed. |
| 25 | Supply and fixing Glow sign board made up of three dimentional crystal LED acrylic or aluminium channel letters mounted on an aluminium composit panel.The base box should be corrosion and rust free. The letter and crests/logos will be three dimensional and backlit. Width of the board 4 feet and height 6 feet.Note:- (a) The matter and logo will be provided by the user at the time of execution and no any claim on this account shall be admissable.(b) Design approval will be obtained from the Engr-in Charge before fabrication.(c) Quoted rate by the contractor will deemed to be included for installation, electrical connections, wirings, consumables, rods, angles, labour or any other item required for complete installation. |
| 26 | S & F stay assembly comprising ofGI stay bow 400 X 14 mm, GI steel stay rod 1800 mm long X 16 mm dia with nut-bolts, washers, GI steel plate 230 X 230 X 6 mm, two Nos. thimble, loop insulator of size 65 X 90 mm clearance of hole 16 mm, stay wire of GI stay strand of size 7 X 3.15 mm fixed to stay assembly and stay clamps with and including necessary excavation and earth work in hard / dense soil, PCC 1:3:6 type C-2 block complete all as specified and directed. |
| 27 | M&L for earthing complete with galvanised steel,earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs belowground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handleto cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 28 | M&L for earthing complete with galvanised steel,earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs belowground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised strip 32x6mm as earth leadby means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 mm c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handleto cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost at his own expances by the contractor. |
| 29 | Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed. |
| 30 | Supply, fabricating and fixing of sheet metal encluser made of 16 gauge MS sheet outdoor type of suitable size including fixing of MCCB of cap 200 Amp, 415 Volt,50Hz, 4 pole, 36 KA, AC supply with 300 Amp rated busbar on porcelain insulators for neutral link double door type with locking arrangement completewith MS angle iron frame of size 25 x 25 x 5mm with nut/bolts andPCC plateform work in 1:3:6 type C-1 including painting with two coat of synthetic enamal paint over one coat of red oxide/ primer complete all as specified and directed at site |