Repair / Maintenance Of Aerodrome Beacon Light, Runway Lights, Ccr, Bollard Lights In Aop Area Under Ge Nasik Road. As Per Tender Documement
Tender Overview
Project Description
Repair / Maintenance Of Aerodrome Beacon Light, Runway Lights, Ccr, Bollard Lights In Aop Area Under Ge Nasik Road. As Per Tender Documement
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Sep-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-Sep-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | S&F of 1000W, 120V lamp for Rotating Beacon 1000 WAB all as specified and directed. |
| 2 | S&F of 1000W, 120V clear/green lens for Rotating Beacon 1000 W AB all as specified and directed. |
| 3 | Supply of 1000W, 120V Beacon lamp holder for Rotating Beacon 1000W AB all as specified and directed. |
| 4 | S&F power unit for Rotating Beacon 1000W AB all as specified and directed. |
| 5 | S&F carbon brushfor Rorating Beacon 1000W AB all as specified and directed. |
| 6 | S&F Slip Ring for Rorating Beacon 1000W AB all as specified and directed. |
| 7 | Supply, Laying and testing XLPE cable insulated screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty 5000 volts grade with standard copper conductor of size 16 sqmm single core all as specified abd directed. |
| 8 | M&L for maintenance of thyristor type NASU make CCR including repairing of defective CCRs by identifying the fault , replacement of defective PCBs and other components and service the same including caliberation of CCR and complete checking , servicing of quarterly base etc as required all as specified and directed.Note : Spare parts required will be measured and paid separately under respective items. ( The rates are inclusive of three visits in nine months )Note forServicing items of the Schedule:-1) The above Item Includes followinga) Labour Charges for Major and Minor repairs including Overhaulsb) Labour charges for all unlimited Breakdown Complaints related to CCRfor a period of nine months c) Preventive Maintenanace 3 visit in nine months(qtrly based ) to carry out Inspection 2) The above Item excludes followinga) Cost of consumables and spares parts require for preventive or breakdown Visits.3) The Spare Parts,used for work under contract must bePurchased fromAuthorised Dealership.4) All works under contract must be carried out by AMA/ NASUTrained Service Engineers.Spare Dealership to have a quick /urgent hastle free service to restore the system in minimum time frame. |
| 9 | M&L for20 KW CCR main control card including RMS to DC convertorcard etc as required all as specified and directed. |
| 10 | M&L forInsulation Monitor card. |
| 11 | M&L for Over current Trip- card. |
| 12 | M&L for Relay card. |
| 13 | M&L for TTM Card ( 02 Nos) |
| 14 | M&L for plug in type relays : VDC ( 01 No for each CCR ) |
| 15 | M&L for plug in type relays : 48 V DC suitable for 11 pin socket. |
| 16 | M&L for plug in type relays : 240V AC ( 1 No for each CCR ) |
| 17 | M&L forT1 300 Trip indication fuses |
| 18 | M&L forhigh speed semi-conductor protection fuses GS 1000/100 ( 01 no eachfor 20 KW CCR |
| 19 | M&L for thyristors : H 150 TB 15 ( 02 nos each for 20 KW CCR ) |
| 20 | M&L for HRC Fuse link :100 Amps( 2nos each 20 KW CCR) |
| 21 | M&L for HRC Fuse link : 32 Amps( 1 nos each 20 KW CCR) |
| 22 | M&L for HRC Fuse link : 4 Amps( 1 nos each for each CCR) |
| 23 | M&L for Digital TRUE RMS METERS: 10 Amp/1 AMP( 1 No for each 20 KW CCR) |
| 24 | M&L for Digital TRUE RMS METERS: 100 Micro AmpDC coil moving meter ( 96X96)..1 each |
| 25 | M&L for Lighting arrestors: 4.5 KV grade ( 2 nos each for all rating of CCR\"s) |
| 26 | M&L for 2 Pole 8 way brillancy switch ( Totary wafer, MBB type) ( 1 Each for each rating of CCR) |
| 27 | M&L for Power transmission MJ11016 ( 2 Nos each for all rating of CCR\"s |
| 28 | M&L for72Acontactors suitable for NASU ,make CCRS ( 20 KW) |
| 29 | S&F connector kit male suitable for runway copper cable 6 Sqmm to 16 Sqmm including breaking coupling for AMA AVN runway light fitting male type complete all as specified and directed. |
| 30 | S&F in repairs connector kit female suitable for runway copper cable 6 Sqmm to 16 Sqmm including breaking coupling for AMA AVN runway light fitting female type all as specified and directed.. |
| 31 | S&F in repair Bi-pin lamp holder for 200W and 45 W , 6.6 Amps halogen lamps complete all as specified. |
| 32 | S&F in repair Bi-pin halogen lamp200W for AUN and APN fitting and PAPI complete all as specified. |
| 33 | S&F in repairs straight through joint kit suitable for PVC XLPE HT under ground cable of size 6.0 to 16.0 Sqmm, 5 KV heat / cold shrink type for runway cables and taxi track cables complete all as specified and directed |
| 34 | S&F in repairs un-directional elevated type high intensity AMA APN runway Approach light fitting suitable for use with 200 Watt/6.6 Amps Halogen Lamp complete with all accessories including lamp and clear or green spreader lense,filters and CI base plate complete all as specified and directed. |
| 35 | S&F in repairs bi-directional elevated type high intensity AMA AUN runway edge light fitting suitable for use with 200 Watt/6.6 Amps Halogen Lamp complete with all accessories including lamp, lense, filters and CI base plate complete all as specified and directed. |
| 36 | S&F in repairs medium intensity elevated type omni directional, AMA ALN LED Taxiway Edge Light Fitting suitable for Taxiway, Apron Edge Lights, Turning pad lights for operations at 6.6 Amps, series circuit supply, complete with omindirectional blue lens (glass), Lens clamping mechanims,breakable coupling, gasket, base plate with 6 Nos m - 10 stainless steel both and other acessories including white LED with an integrated encapsulated converter of power consumption approx 45W 6.6A, complete fitting confirming to latest ICAD requirment all as specified and directed. |
| 37 | S&F in repairs Isolating Transformer 15 watt, 6.6 Amp, 500 Volt grade, all as specified and directed.. |
| 38 | S&F in repairs Isolating Transformer 200 watt, 6.6 Amp, 500 Volt grade all as specified and directed.. |
| 39 | S&F in repairs for rolled mild steel work such as joint, channel, angle, or tee sections, fixed indpendently, without connecting plates, etc. (cut to ordinari lengths i.e. within 20mm of the length indicated, complete all as specified and directed. (Stand suitable for fixing LED Taxyway Edge Light approximately 10 Kg per stand x 10 Nos = 200 Kg) |
| 40 | S&F in repairs 180 degree filter-Red/Green/Yellow Clear for AMA AUN Runway Fitting complete all as specified and directed. |
| 41 | S&F in repairs Red Spreader Lens for APN Eng Fitting complete all as specified and directed. |
| 42 | S& F XLPE insulated armoured and PVC sheated heavy duty electric cable of size 2 core 10 sqmm aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendmentlaid in tranches passing through pipes /ducts including testing completenote- rate is inclusive of cable gland & cable lugs |
| 43 | All as Per Item No. 42.00 but size 4 core 16 sqmm |
| 44 | All as Per Item No. 42.00 but size 3.5 core 35 sqmm |
| 45 | All as Per Item No. 42.00 but size 3.5 core 50 sqmm |
| 46 | Taking down unserviceble, damaged, faulty LT/HT underground cable from trenches, wall, floor etc. of any size / core / type / make, removed against item No. 7 &41 complete all as specified and directed. |
| 47 | M&L Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole |
| 48 | M&L Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concreteas specified. |
| 49 | EXCAVATION BY TENCHLESS TECH - Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia. Suitable for 0.4 mpa working pressure. |
| 50 | Excavation in trenches in soft / loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable, RCC poles / stays and struts etc. and getting out including trimming sides and forming bottom surface complete all as specified and directed at site. |
| 51 | Returning, filling in including spreading, leveling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed. |
| 52 | Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed. |
| 53 | M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and innter dia 38mmincluding 90 degree bends with coupler and rubber ringlaid in trenches of size 50 mm suitable for cable protection complete all as specified and directed. |
| 54 | S&F in repairs cable jointing kitof size 4 core 16 sqmm to 50 sqmm all as specified and directed. |
| 55 | S&F in repairs cable jointing kitof size 3.5 core 50 sqmm to 95 sqmm all as specified and directed. |
| 56 | S&F in repairs LIARA IP 65 rated inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution all as specified and directed by Engr-in-Charge. |
| 57 | S&F in repairs 45 WDecorative indirect post toplandscape lighting with IP -65 protection , resistance to impact and corrosion , Anti-glare and uniform distribution all as specified and directed. |
| 58 | S&F LED aviation lighting with cast aluminium housing and polycarbonate all as specified and directed by Engr-in-Charge. |
| 59 | Supply, fix, connect and test LED street light fitting 60W, pressure die cast aluminum housing, heat resistance toughened glass, IP 66 protection, better optics for uniform distribution, aesthetically designed roadway luminiare with excellent thermal management,complete all as specified and directed. |
| 60 | S&F in repairs 80 W LED flood light fitting, pressure die cast with IP 66 protection, efficient high output emmitter LED for better distribusion, surge protection device 5KV upto rated power 150 W ,complete all as specified and directed. |
| 61 | S&F in repaires PVC insulated 3 core 1.5 sqmm multistranded (un armoured 2XY) copper conductor complete all as specified and directed. |
| 62 | Testing only for finding out cable fault location of cable PVC armoured copper conductor single core 16 sqmm (7/1.05) 5 KV from ATC to CCR, CCR to taxiway light fitting/main runway by applying voltage DC source using BICO (UK) cable fault detection test, sort & find out , pin out fault location all as specified and directed by Engr-in-Charge |
| 63 | S&F in repairs LED outdoor drivers, suitable for 40-45W street light fitting all as specified and directed. |
| 64 | S&F in repairs power contactors ML-3 , 3 pole rating not less than 40A , 230 coil. All as specified and directed. |
| 65 | S&F in repairs AlphaRex3 digital time switches D-22 astro , multifunctional digital time switches all as specified and directed by Engineer-in-Charge. |
| 66 | S&F junction box of size Size 250 x 200 x 100mm complete with industrial connector including clampsmade out of MS flat iron 30 x 5mmandsuitable MCB as specified anddirected. |
| 67 | All as per Item No. 66.00 but Size 185 x 165 x 60 mm. |
| 68 | Taking down of street light bracket including clamps of any type/any size from pole/wall including necessary nuts & bolts all as specified and directed. |
| 69 | M&L for fabrication and installation of GI pipe bracket made of medium frade tubing of size 40mm dia duly bended by hot forging after filling of sand, length 1.20 mtr includingtwo pairs of MS flat strip clamps 30 x 5mm with GI bolts, nuts and washers complete all as specified and directed. |
| 70 | Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450mm x 450mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 11 mtr long 410 SP-31 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge. |
| 71 | Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450mm x 450mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 9 mtr long 410 SP-22 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge. |
| 72 | Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved aluminium bus bar of rating 300 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.00 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs cable glandand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:- (A) Incoming:- (a) Aluminium bus bar TPN 450 Amps - 01 Set (i)Danger notice plate/ sticker of suitable size on front panel board -01 No(ii) MCCB 4 pole 250 A36 kA-01 No (B) Outgoing:-(i) MCCB TPN 100 Amps04No (ii) MCCB TP 63 Amps02 No(iii)MCB SPN 63 Amps 01 Nos (v) Each outgoing Feeder Name Radium StickerInside Panel. (vi)voltmeter, Ammeter and selecor switch (vii)Phase indication lamp R, Y, B LED type |
| 73 | S&F in repairs metal boxMS enclosure made out of CRCA sheet 3.00mm thick of size 450mm x 450mm x 250mm depth withthree phase aluminium bus bar and fixing3P 100A MCCB mounted on epoxy insulators, fixing arrangement with suitable MS Clamps all as specified and directed. |
| 74 | S&F Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod ofGI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,400 Ampsincl dismantling of old one all as specified. |
| 75 | Dismantling of U/S existing cross arms by means made from channels, angles, U/S FI clamps, nuts, bolts etc. from OH line and removing complete. |
| 76 | S&F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide . |
| 77 | M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (9.0 mtr length) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium stickerRadium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge |
| 78 | M&L for cable jointing kit for 11 KV ( Earthed) gradecable for straight throughheatshrink type joint complete with jointing material and accessories suitable for 3 core XLPE armouredaluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge |
| 79 | M&L for cable jointing kit for 11 KV ( Earthed) gradecable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armouredaluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge |
| 80 | M&L for cable jointing kit for 11 KV ( Earthed) gradecable for outdoortermination Heatshrink type joint complete with jointing material and accessories suitable for 3 core XLPE armouredaluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge |
| 81 | M&L Earthing with 600X600X6 mm thick , galvanised steel earth plate electrode buried vertically in ground (Earth pit not less than 2.25 meter deep below normal ground level ) with top edge of plate vertically at a depth ,not less than 1.5 m below ground level connected to and including GI strip of size 32X6 mm by means of bolts,nuts,check nuts, And washer of galvanised steel,Gi shripto be provide upto the extent of 7.5 m GI strip to be duly connected to metalic bodies of HT/LT equipment with provision of mixture of charcoal dust & common salt packed all ground the earth plate upto MS funnel with wire mesh provided inside concrete earth pit for watering arrangement,complete all as shown on electrical plate no.3 of SSR Part I (2009) and testing on completion. |
| 82 | S&F MCCB 4 pole in LT Panelthermal magnetic settingof current amp 400A , breaking capacity 25kAcomplete with lugs ,spreader link, gland to cable complete all as specified and directed. |
| 83 | S&F MCCB 4 pole in LT Panelthermal magnetic settingof current amp 250 A , breaking capacity 25kA, complete with lugs ,spreader link, gland to cable complete all as specified and directed. |
| 84 | S&F MCCB TPN in LT Panelthermal magnetic settingof current amp 160A , breaking capacity 25kA, complete with lugs ,spreader link, gland to cable complete all as specified and directed. |
| 85 | S&F MCCB TP in LT Panelthermal magnetic settingof current amp 125A , breaking capacity 16kA complete with lugs ,spreader link, gland to cable complete all as specified and directed by Engr-In-Charge. |
| 86 | S&F MCCB TP in LT Panelthermal magnetic settingof current amp 100A , breaking capacity 16kA, complete with lugs ,spreader link, gland to cable complete all as specified and directed directed by Engr-In-Charge. |
| 87 | NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS. 21,970.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender