Delhi Tourism And Transportation Development Corporation Limited-DTTDC has published Providing Power Distribution, Fire Safety Facilities For Server Room At 14 Locations And Other Minor E & M Associate Works- 1 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Followingsizesoffrlspvcinsulatedcopperconductor, Singlecore. Submission Date for this Tender is 02-09-2022. Coats and Jackets Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,singlecore cable in surface/ recessed medium class PVC conduit as required. (2 X 10 sq. mm + 1 X 6 sq. mm earth wire) |
2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
3 | 3 x 1.5 sq. mm |
4 | 3 x 2.5 sq. mm |
5 | 6 x 2.5 sq. mm |
6 | 6 x 4 sq. mm |
7 | Supplying andfixing offollowing sizes ofmedium class PVC conduit along withaccessoriesinsurface/recessincludingcutting thewalland making good the same in case of recessed conduit as required. |
8 | 25 mm |
9 | 32 mm |
10 | Supplying andfixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
11 | 5/6 A switch |
12 | 3 pin 5/6 A socket outlet |
13 | 15/16 A switch |
14 | 6 pin 15/16 A socket outlet |
15 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
16 | 1 or 2 Module |
17 | 6 Module |
18 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
19 | 1 run of cable |
20 | 2 run of cable |
21 | 3 run of cable |
22 | Earthing with G.I. earth Plate 600mm x 600mm x 6mm thick including accesssories, and providingmasonary enclosurewith cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required. (For Body earthing of euipment) |
23 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe fromearthelectrodeincludingconnectionwithG.I.nut,bolt,spring, washer excavation and re-filling etc. as required. |
24 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
25 | Providingandfixing6SWGdiaG.I.wireonsurfaceorinrecessfor loopearthingalongwithexistingsurface/recessedconduit/submain wiring/ cable as required. |
26 | Supplyingandfixing of60x45mmPVCcasing along withcapping on the surface complete etc. as required. |
27 | Supplying and fixing of 100x100mm PVC casing along with capping on the surface complete etc. as required. |
28 | Designing ,Supplying, installation, testing & commissioning of outdoor type (IP-65)Electrical Panels, cubicle type, made out of 2 mm thick 14 SWG CRCA sheet, totally enclosed, free standing, floor/Wall mounting, dust and vermin proof, indoor type , compartmentalised,front openable double door with lock arrangement , suitable eartthing link , suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with suitablebusbars, including internal wiring with suitable size of wires / cables, interconnection, duly powder coated painting with 7 process etwith earth bus and lifting hooks as requiredin case of large panelsincluding supplying & installation of suitable stand with angle frame size 40 mm x 40 mm x 5 mm (400 mm Long) of following switchgears, therein,and accessories as per specifications & Prior approval shall be taken for each panel before fabrication as per approved Drawing by Engineer-in-charge. (All hardwares like nuts and boltsused shall be Galvanized and Zinc passivated ) Minimum Panel Depth is 250 mm. Face Area of Panel- 2.0 SQ. MM |
29 | INCOMER:- a) 2-No. 125 A 4 Pole 4MCCB ,36 KAwith Contractor TM releaseControllerhaving adjustable O/I ,S/C Protection and Extended Roatary handle ans spreder link for incoming Source-I & II & all acessories Automatic Change Over Switch(ATYs) b) 1-No. 63 A 4 Pole 415 V , ,ATS with Controller & all acessories Metering & Indication:- a) 2 set of R,Y,B phase indicating lamps with 6 A , 10 KA ,MCB b) 1 nos. Digital type multi function meters ( A+V+KWH+KVAR+ F+ PF+KVA ) with castresin CTs 150/5A ,Class-1 BUS BAR: a) 1 Set of 150 TPN Aluminium Bus Bar with colour coded PVC Sleeves |
30 | OUTGOINGS:- a) 1-Nos ,100 A, 4P, 36 KA, MCCB with Extended Rotary Handle and Spreder Link b) 1-Nos ,63 A, 4P, 10 KA, MCCB with Extended Rotary Handle and Spreder Link c) 4-Nos ,32/ 40 A, DP,10KA, MCB d) 2-Nos ,40 A, TPN,10KA, MCB One Complete Set |
31 | Supplyingof one no. XLPE Insulated PVC Sheathed Armoured Power Cable with aluminium conductor armouredof 1.1 KV grade of size of 3½ x 35 Sq. mm by following methods: |
32 | Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of XLPE Insulated PVC Sheathed Armoured Power Cable aluminium conductor cable of 1.1 KV gradeetc complete as required. - 3½ x 35 Sq. mm |
33 | Laying of one number additional PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizedirect in ground in the same trench in one tier horizontalformation including excavation, sand cushioning, protectivecovering and refilling the trench etc as required. - Upto 35 sq. mm |
34 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required - Upto 35 sq. mm |
35 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. - Upto 35 sq. mm |
36 | Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on wall surface as required. - Upto 35 sq. mm (clamped with 1mm thick saddle) |
37 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
38 | Supplying and fixing PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 wire following sizei/c connections, testing etc.completeas required - 4 core x 10 Sq.mm |
39 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 4 way (4 + 12), Double door |
40 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
41 | Double pole |
42 | Triple pole and neutral |
43 | Supplying and fixing 32 A/40 A, 240 V, SPN Industrial type socketoutlet(male female type) with 2 pole and earth, metal enclosed plug topalongwith 32 A/40 A, "C" curve, DP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the male female socket outlet and complete with connections, testing and commissioningetc. as required. |
44 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
45 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
46 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
47 | Supply, Installation, Testing and Commissioning of 2.0 LB capacity Novec 1230 Fire Suppression Systems with 3M Novec 1230 Fire Protection Fluid, DLP Assembly with automatic valve, push in connector for tube, 2.5 LB Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation etc. as required. |
48 | Supply, Installation, Testing and Commissioning of Linear pneumatic heat Detection Tube with all necessary fittings & supports etc. as required. |
49 | Supply, Installation, Testing and Commissioning of Master Control Unit with Audio Visual Alarm with wiring to make complete system operational . Thecontrol Panel should have provision for integration with fire Alarm etc. as required. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail