Wss To Adoor And Adj Panchayath Pipe Line Extension In Enadimangalam Panchayath At 9 Locations And Chemmanettam Colony In Ward 9 Of Enadimangalam Panchayath Wss To Adoor And Adj Panchayath Pipe Line Extension In Enadimangalam Panchayath At 9 Locations And
Tender Overview
Project Description
Wss To Adoor And Adj Panchayath Pipe Line Extension In Enadimangalam Panchayath At 9 Locations And Chemmanettam Colony In Ward 9 Of Enadimangalam Panchayath Wss To Adoor And Adj Panchayath Pipe Line Extension In Enadimangalam Panchayath At 9 Locations And Chemmanettam Colony In Ward 9 Of Enadimangalam Panchayath
BOQ
| Sl. No. | Item Description |
| 1 | Pipe line extensioninvariousWards of Enadimangalam Panchayath( 9 Locations) |
| 2 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) |
| 4 | Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 90 mm nominal outer dia pipes.\" |
| 5 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore |
| 6 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 7 | 160 mm dia PVC pipe for Valve protection |
| 8 | Interconnection of newly laid PVC pipe with existing AC/PVC pipe including cost of specialscomplete as per direction of Dept.officers. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 10 | Supplying and fitting 90mm pvc end cap |
| 11 | Supply of Materials |
| 12 | Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 90mm Dia. |
| 13 | Pipeline extension in chemmanettam colony in ward 9 of enadimangalam panchayath |
| 14 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 15 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) |
| 16 | Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 90 mm nominal outer dia pipes.\" |
| 17 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore |
| 18 | Interconnection of newly laid PVC pipe with existing AC/PVC pipe including cost of specialscomplete as per direction of Dept.officers. |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 20 | Supplying and fitting 90mm pvc end cap |
| 21 | Supply of Materials |
| 22 | Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 90mm Dia. |
| 23 | Note: Rs :20348/- is included for PWD Road Tar Cutting Chatrge and GST @ 18 % Should be paid additionallly |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender