Construction Assam Type Sub-Centre Building With Electrification, Water Supply And Sanitary Works Etc At Dakhin Rangia In Kamrup District C
Tender Value
33.71 Lakhs
Estimated cost
Bid Submission
23 Sep 2022
0 days left
EMD
67420
Bank guarantee accepted
Document Fee
1200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
rangia → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Assam Type Sub-Centre Building With Electrification, Water Supply And Sanitary Works Etc At Dakhin Rangia In Kamrup District C
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal sizederived from natural sources) |
| 3 | Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 4 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 6 | Brick on edge flooring with bricks of class designation 7.5 on a bed of12 mm cement mortar, including filling the joints with same mortar, withcommon burnt clay non modular bricks: 1:6 (1cement : 6 coarse sand) |
| 7 | Centering and shuttering including strutting, propping etc. and removalof form for Foundations, footings, bases of columns, etc. for massconcrete |
| 8 | Centering and shuttering including strutting, propping etc. and removalof form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 9 | Centering and shuttering including strutting, propping etc. and removalof form for Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 10 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floatingcoat of neat cement on the rough side of single or half brick wall. |
| 11 | 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete. |
| 12 | Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface :Water thinnable cement primer |
| 13 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 14 | Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete. |
| 15 | Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. Fixed to steel windows by welding |
| 16 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingPrimer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Twoor more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.80 ltr/10 sqm of approved brand and manufacture |
| 17 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand andmanufacture on steel galvanised iron/ steel works |
| 18 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 19 | Excavating, supplying and filling of local earth (including royalty) bymechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. |
| 20 | Brick work with common burnt clay machine moulded perforated bricksof class designation 12.5 conforming to IS: 2222 in superstructure aboveplinth level up to floor five level in cement mortar 1:6 (1 cement : 6coarse sand) :With F.P.S.(non modular) bricks |
| 21 | Centering and shuttering including strutting, propping etc. and removalof form for Suspended floors, roofs, landings, balconies and accessplatform with water proof ply 12 mm thick |
| 22 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 23 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittings This includes jointing of pipes & fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in Charge 100 mm nominal dia Pipes |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittings This includes jointing of pipes & fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in Charge.80 mm nominal dia Pipes |
| 25 | Providing and fixing plain bend of required degree. 100 mm diaand cast iron S&S as per IS : 3989 |
| 26 | Providing and fixing white vitreous china pedestal type water closet (Europeantype) with seat and lid, 10 litre low level white vitreous china flushing cistern& C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflowarrangement with specials of standard make and mosquito proof coupling ofapproved municipal design complete, including painting of fittings andbrackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 27 | Providing and fixing one piece construction white vitreous china squattingplate with an integral longitudinal flushing pipe, white P.V.C. automatic flushingcistern, with fittings, standard size G.I. / PVC flush pipe for back and frontflush with standard spreader pipes with fittings, G.I clamps and C.P. brasscoupling complete, including painting of fittings and cutting and making goodthe walls and floors etc. wherever required : Single squatting plate with 5 litre P.V.C. automatic flushing cistern |
| 28 | with C.I. brackets and stainless steel plug 40 mm, including painting of fittingsand brackets, cutting and making good the walls wherever required : Kitchen sink with drain board510x1040 mm bowl depth 250 mm |
| 29 | Providing and fixing PTMT towel rail complete with brackets fixed to woodencleats with CP brass screws with concealed fittings arrangement of approvedquality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effectiveheight of 88 mm, weighing not less than 190 gms. |
| 30 | Providing and fixing slotted cowel of 75mm dia Rate @ 215.00/each vide code No 1639 Sanitary fittings |
| 31 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame ofrequired shape and approved quality L D- 2.5Square shape 450 mm internal dimensions |
| 32 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drainpipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 33 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 34 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangementand making necessary holes for inlet, outlet and overflow pipes but withoutfittings and the base support for tank. |
| 35 | Boring with 100 mm diameter casing pipe for hand pump / tubewell, in allsoils except ordinary hard rocks requiring blasting, including removing thecasing pipe after the hand pump / tube well is lowered and tested : Beyond 12 m and up to 18 m depth |
| 36 | Providing and placing in position filters of 40 mm diameter G.I. pipe withbrass strainer of approved quality. |
| 37 | Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipefor tube well including cleaning and priming the tube well. |
| 38 | Providing and placing in position hand pump of approved quality for 40 mmdiameter G.I. pipe complete with all accessories |
| 39 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. allcomplete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia |
| 40 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, toestablish maximum rate of usable water yield without sand content (beyondpermissible limit), with required capacity air compressor, running the compressorfor required time till well is fully developed, measuring yield of well by \"V\" notchmethod or any other approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour chargesof air compressor, tools & accessories etc., all as per requirement and direction ofEngineer-in-charge. |
| 41 | Providing and fixing C.P. brass long nose bib cock of approved qualityconforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 42 | Providing and fixing C.P. brass stop cock (concealed) of standard designand of approved make conforming to IS:8931.15 mm nominal bore |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittings This includes jointing of pipes & fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in Charge. External work25 mm nominal dia Pipes |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittings This includes jointing of pipes & fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in Charge. External work32 mm nominal dia Pipes |
| 45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittings This includes jointing of pipes & fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in Charge. External work40 mm nominal dia Pipes |
| 46 | Single phase Submersible motor pump set (TEXMO/Crompton Greaves/Aquatic/CRI/v-Gurd/Calma make) suitable for 100mm bore well and above 1.5 HP STAGE 5 to 26 with contrl panel |
| 47 | Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) |
| 48 | Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete |
| 49 | Centering and shuttering including strutting, propping etc. and removalof form for Weather shade, Chajjas, corbels etc., including edges |
| 50 | Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle thresholdof mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge: Fixing with adjustable lugs with split end tail toeach jamb |
| 51 | Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated sectionhaving overall dimension 115 mm x 37 mm with wall thickness 2 mm (±0.2 mm) with inbuilt beading on one side, the styles and rails mitred cutand joint at corners by inserting 2 nos PVC profile reinforcement of size75 mm x 200 mm long with cross section size of 28 mm x 30 mmhaving wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to bereinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles afterinserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated andinserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer\"s specification and direction of engineer-in-charge. |
| 52 | Providing and Fixing factory made PVC door frame made of PVC extrudedsections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2mm). Both verticalssides of the frame reinforced with PVC profile ofcross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and75 mm x 200 mm long, including reinforcing both ends of the top framewith PVC profile. PVC Door Frame and PVC reinforcement profile to bemitred cut, jointed and fusion welded together, including providing andfixing 3 nos of 125 mm long stainless steel hinges to frame, fixing theframe with jamb with required nos & sizes of anchor dash fastener, allcomplete as per manufacturer\"s specification and direction of engineerin-charge. |
| 53 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 54 | Providing and fixing double glazed hermetically sealed glazing in aluminiumwindows, ventilators and partition etc. with 6 mm thick clear float glass bothside, having 12 mm air gap, including providing EPDM gasket, perforatedaluminium spacers, desiccants, sealant (Both primary and secondary sealant)etc. as per specifications, drawings and direction of Engineer-in-chargecomplete. |
| 55 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching pigments etc., complete.11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size |
| 56 | IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. |
| 57 | Providing and fixing insulating board ceiling of approved quality withnecessary nails etc. complete (frame work to be paid separately) : Natural colour insulating board12.24.1.1 12 mm thick |
| 58 | Providing corrugated G.S. sheet roofing including vertical / curvedsurface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 59 | Providing ridges or hips of width 60 cm overall width plain G.S. sheetfixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m² |
| 60 | Distempering with 1st quality acrylic distemper (ready mixed) having VOCcontent less than 50 gms/litre, of approved manufacturer, of required shadeand colour complete, as per manufacturer\"s specification.13.42.1 Two or more coats on new work |
| 61 | Applying priming coatWith ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 62 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 13.61.1 Two or more coats on new work |
| 63 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washersas required complete as per the direction of Engineer-in-charge.16.70.1 Made of G.I. wire of dia 4 mm |
| 64 | Providing bird proofing hexagonal galvd. Wire neeting at ceiling level of Assam type building |
| 65 | NA Suppling and installation of signboard where necessery as directed by the Deptt (Rs 13090) |
| 66 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with piano type switch, phenolic laminated sheet, suitable size MS box andearthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor singlecore cable etc as required. Group A |
| 67 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with piano type switch, phenolic laminated sheet, suitable size MS box andearthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor singlecore cable etc as required. Group B |
| 68 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with piano type switch, phenolic laminated sheet, suitable size MS box andearthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor singlecore cable etc as required. Group C |
| 69 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with modular switch, modular plate, suitable GI box and earthing the pointwith 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc asrequired.Group B |
| 70 | Wiring for circuit wiring alongwith earth wire with the following size of LRLS PVC insukated copper conduvtor single core cable in surface/Recessed steel conduit as required |
| 71 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required` |
| 72 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 73 | Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. asrequired. 15/16 A switch |
| 74 | Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. asrequired. |
| 75 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 76 | Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet coveron the fan box etc. as required. |
| 77 | Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required |
| 78 | Supplying and fixing following rating, four pole, (three phaseand neutral), 415 volts, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. asrequired. 25 A |
| 79 | AN-1 Prem. Model 1200 mm sweep orient 1200mm sweep SS-390 Deco (PWD Schedule) |
| 80 | ASEB CONNECTION |
| 81 | FAN HOOK |
| 82 | Erection of RCC/ PCC pole strut in brick ballast and ramming thefoundation including excavation and refilling and secured withholding clamps, bolts, nuts, etc. as required. |
| 83 | Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays with perforation not morethan 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 84 | Providing and fixing white vitreous china flat back half stall urinal of size580x380x350 mm with white PVC automatic flushing cistern, with fittings,standard size C.P. brass flush pipe, spreaders with unions and clamps (all inC.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating andother couplings in C.P. brass, including painting of fittings and cutting andmaking good the walls and floors wherever required :17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 85 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillartaps, 32 mm C.P. brass waste of standard pattern, including painting of fittingsand brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P.brass pillar taps |
| 86 | Centering and shuttering including strutting, propping etc. and removalof form work for :Retaining walls, return walls, walls (any thickness) includingattached pilasters, buttresses, plinth and string courses fillets,kerbs and steps etc. |
AI Tender Summary
Tender Timeline
Aug 27, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedSep 23, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 26, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer