}

Repair / Maint Of Ceiling Fan Wall Mounted Fan Electric Gyesers Electric Meter Solar Water Heater And Connected Works At Ins Kalinga Ins Karna And Nad Bheemunipatnam Visakhapatnam, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Repair / Maint Of Ceiling Fan Wall Mounted Fan Electric Gyesers Electric Meter Solar Water Heater And Connected Works At Ins Kalinga Ins Karna And Nad Bheemunipatnam Visakhapatnam. Submission Date for this Tender is 27-09-2022. Solar Heater Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33678789
Corrigendum : Repair / Maint Of Ceiling Fan Wall Mounted Fan Electric Gyesers Electric Meter Solar Water Heater And Connected Works At Ins Kalinga Ins Karna And Nad Bheemunipatnam Visakhapatnam
Open Tender
Indian
Andhra Pradesh
visakhapatnam
27-09-2022

Tender Details

Repair / Maint Of Ceiling Fan Wall Mounted Fan Electric Gyesers Electric Meter Solar Water Heater And Connected Works At Ins Kalinga Ins Karna And Nad Bheemunipatnam Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Sep-2022 CORRIGENDUM FOR CHANGE IN BOQ AND PARTICULAR SPECIFICATION BOQ 20-09-2022
2 10-Sep-2022 CORRIGENDUM FOR CHANGE IN DATE AND BOQ Date 20-09-2022
3 20-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
INR 9 Lakhs /-

BOQ Items

Name of Work : REPAIR/ MAINT OF CEILING FAN WALL MOUNTED FAN ELECTRIC GYESERS ELECTRIC METER SOLAR WATER HEATER AND CONNECTED WORKS AT INS KALINGA INS KARNA AND NAD BHEEMUNIPATNAM VISAKHAPATNAM
Sl. No. Item Description
1Checking of ceiling fan 1200mm sweep at site when and where required asMES complaint slip on daily basis if required except Sunday and holidays in existing position including Supply and fixing as replacement at site in position ceiling fan condenser 2.5 mfd all as specified and as directed.
2All as per item No. 1 here-in-before but ceiling fan 1400mm sweep when and where required asMES complaint slip on daily basis if required except Sunday and holidays and ceiling fan condenser 3.15 mfd all as specified and as directed.
3Taking down carefully existing ceiling fan of any sweep and any make after disconnecting the electrical connections, dismantling the blades and removing fan including blades to the workshop including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spare parts with new parts including necessary machining works and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connections and material and labour for replacement of two nos split pins, one connection block and one rubber reel complete all as specified and as directed. Note:- (i) Rewinding work of armature (if any) shall be measured and paid separately (ii) New spare parts required for replacing old burnt out parts other than connector, split pins, connection block and rubber reel shall be measured and paid separately under relevant item as supply only. (iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate of item No. 3.00
4Taking down carefully existing exhaust fan of size upto 300 mm sweep and any make after disconnecting the electrical connections and removing the exhaust fan with blades to the workshop including cleaning of dust and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spare parts with new parts including necessary machining works and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete, testing and refixing the fan in same position including all electrical connections and material and labour for replacement of one connection block complete all as specified and as directed. Note :- (i) Rewinding work (if any) shall be measured and paid separately (ii) New spare parts required for replacing old burnt out parts other than connector shall be measured and paid separately under relevant item as supply only. under item No 18 to 24 here-in- after. (iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate of item No. 4.00
5All as per Item No. 4 here-in-before but for exhaust fan of size upto 450 mm sweep complete all as specified and as directed.
6Taking down and refixing after repair air circulation fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed. Note for Item Nos 18 to 24 : Bearing/gun metal bush/rubber bush & bolts/capacitor/rewinding/cord flexible/shaft etc. will be measured and paid separately
7Taking down and refixing after repair wall mounted fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed.
8Taking down and refixing after repair pedestal fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed.
9M&L for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200 mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and as directed.
10All as per Item No. 9 here-in-before but for ceiling fan of size 1400 mm sweep complete all as specified and as directed.
11All as per Item No. 9 here-in-before but for exhaust fan of size upto 300 mm sweep complete all as specified and as directed.
12All as per Item No. 9 here-in-before but for exhaust fan of size upto 400/450 mm sweep complete all as specified and as directed.
13All as per Item No. 9 here-in-before but for wall mounted fan of size upto 400/450 mm sweep complete all as specified and as directed.
14All as per Item No. 9 here-in-before but for air circulator/ pedestal fan of size 450 mm sweep complete all as specified and as directed.
15All as per Item No. 9 here-in-before but for flame proof ceiling fan of size 1200/ 1400 mm sweep complete all as specified and as directed.
16All as per Item No. 9 here-in-before but for flame proof exhaust fan of size 400/ 450 mm sweep complete all as specified and as directed.
17All as per Item No. 9 here-in-before but for flame proof wall mounted fan of size 400/450 mm sweep complete all as specified and as directed.
18Supply only ball bearing, bearing No. 6201/ 6202 for ceiling / exhaust fan complete all as specified and as directed.
19Supply only ball bearing, bearing No. 6203/ 6204 for ceiling / exhaust fan complete all as specified and as directed.
20Supply only fan capacitor 2.5 mfd
21Supply only fan capacitor 3.15 mfd
22Supply only gun metal bush
23Supply only mounting clamp assembly for ceiling fan of 1200 mm/ 1400 mm sweep with amp, blot, nut, washers, safety/ split pins and rubber bush complete all as specified and as directed.
24Supply only down rod assembly complete for ceiling fan of 1200 mm/ 1400 mm sweep complete all as specified and as directed.
25S&F electronic deluxe rotary step type fan regulator including taking down old unserviceable one complete all as specified and as directed.
26S&F modular step type fan regulator 120W, 2 module complete all as specified and as directed.
27M&L for cleaning/preparation of surfaces of ceiling fan 1200mm/ 1400mm sweep thoroughly and painting with one coat of spray painting using synthetic enamel white paint over the existing paint and writing of serial/ MES number with black paint having each letters/figures in Block of height n.exc 2 cm over it complete all as specified and as directed by the Engineer-in-Charge.
28All as per Item No. 27 here-in-before but for painting to exhaust fan with blade ofany size complete all as specified and as directed.
29All as per Item No. 27 here-in-before but for painting to air circulator/ pedestal fan of 400 mm sweep complete all as specified and as directed.
30S&F in repair louver shutters for exhaust fan of size upto 450 mm sweep suitable for any make made of MS sheet including two coats of synthetic enamel paint over a coat of red oxide primer and bolt, nut, washer etc including taking down old unserviceable one complete all as specified and as directed.
31Supply only cord flexible copper conductor three core 23/0.0076 Sqmm PVC insulated sheathed 1100 V grade complete all as specified and as directed by the Engineer-in-Charge.
32M&L for comprehensive repair/ maintenance of storage type electric water heater (geyser) vertical or horizontal type of capacity 25 ltrs comprising of the following :- (a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the satisfaction of the Engr-in-Charge. (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing then washers/ gasket nut etc. (c) Checking and rectifying earth continuity of the electrical circuits of the geyser and power point. (d) Checking and refixing thermostat and re-adjust (e) De-scaling the immersion type heating element and siphon assembly with diluted hydro chloric acid or clear pedette solution. (f) Checking of indicator lamp for its serviceability (g) Re-assembling the Geyser, re-install and testing complete. Note : Parts/ components of geysers found unserviceable shall be replaced by the contractor. New parts/ components required shall be measured and paid separately under Item No. 34 to 43 here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate of item No. 32
33M&L for comprehensive repair/ maintenance of solar water heater (geyser) horizontal type of capacity 100/500 ltrs comprising of the following :- (a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the satisfaction of the Engr-in-Charge. (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing then washers/ gasket nut etc. (c) Checking and refixing solar flat plate collector/ tube collector and re-adjust (d) De-scaling the immersion type heating element and siphon assembly with diluted hydro chloric acid or clear pedette solution.
34Supply only thermostat of Type EST 11/ 20 A, 250 volt of approved make and having ISI marked complete all as specified and as directed.
35All as per item No. 34 here-in-before but for Type EST 7/ 15 A, 250 volt of approved make and having ISI marked complete all as specified and as directed.
36Supply only heating element of capacity 2 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type/ screw type/ triangular/ circular base or ceramic cartridge type), ISI marked complete all as specified and as directed.
37Supply only heating element of capacity 2/3 KW AC 240 volts suitable for storage type solar water heater as per site requirement (press type/ screw type/ triangular/ circular base or ceramic cartage type), ISI marked complete all as specified and as directed.
38All as per item No. 36 here-in-before but of capacity 1.5 KW AC 240 volts ISI make and as per sample complete all as specified and as directed.
39Supply only copper siphon assembly suitable for 25 ltrs capacity geysers of any make as required at site of approved make complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamp for fixing heating element etc including gasket complete all as specified and as directed.
40Supply only plug top 3-pin 16 Amps
41Supply only PVC insulated PVC sheathed flexible round stranded copper conductor of size 2.5 sqmm, 3 core
42Supply only LED Neon type indicator lamp 240 Volt AC suitable for 25/50 ltrs geyser complete all as specified and as directed.
43Supply only safety valve suitable for 25/50 ltrs geyser complete all as specified and as directed.
44S&F earth plug socket with MCB DP 20 Amps including taking down old unserviceable one complete all as specified and as directed.
45S&F plug top earth plug socket upto 20 Amp C-Curve including taking down old u/s one
46M&L for tracing and arresting of leakage in storage tank of 25 ltrs capacity geysers by brazing and soldering at leakage point and testing on completioncomplete all as specified and as directed.
47Taking down Geyser of capacity25 ltrs from its existing position after disconnecting inlet and outlet water connection including M&L for spray painting to Geysers of capacity 25 ltrs with one coat of Ist grade synthetic enamel paint of approved tint after preparation of old steel surfaces including writing serial / MES number (with black colour paint with each letters/ figures (in Block) of height n. exc 2 cm) and refixing the Geysers to its existing position on completion of painting including making inlet/outlet water connection and testing complete all as specified and as directed.
48S&F in repair PVC connection pipe with two brass adaptors 450mm long & fixing in position including taking out old unserviceable one complete all as specified and as directed.
49S&F in repair chromium plated connection pipe for hot water of length upto 60 Cm, with two brass connecting nut with gasket and connecting up including taking out old unserviceable one complete all as specified and as directed.
50S&F in repair non-return valve, ISI marked 15mm bore as in replacement of old one and connection complete all as specified and as directed.
51S&F Anchor bolts of size 10mm dia, 100mm long including nuts and washer for mounting thegeyser complete all as specified and as directed.
52S&F water heater (Geyser) storage type 5 star rated AC 230 Volts of capacity 25 litres with grounding of 4 nut and bolts and connecting pipe for outlet and inlet water from geyser complete incl taking out old u/s kept deposit in MES store all as specified and directed
53S&F MS ceiling fanMS hook suitable length all as specified and as directed.
54S&F ceiling fan energy saving type 5 Star 1200 mm sweep decorative blades pearl white with fan regulator and hook at proper position and making connection by using flexible copper conductor wire all as specified and as directed. (Cart Part No. ES 40 of Make Havells or equivalent model as approved by GE)
55S&F wall mounted air circulator fan PVC body 400 mm sweep 230 volt, SP complete with accessories incl taking out old u/s kept deposit in MES store all as specified and as directed. (Cat Part No. Turbo force of Havells or equivalent as approved by GE)
56S&F pedestal fan PVC body 400 mm sweep 230 volt, SP completewith accessories incl taking out old u/s kept deposit in MES store all as specified and as directed (Cat Part No. Turbo force of Havells or equivalent as approved by GE)
57S&FPVC Exhaust fan of size 200 mm sweep, 230 volt ACwith connection from existing ceiling rose with louver shutter incl taking out old u/s kept deposit in MES store all as specified and as directed.
58S&FPVC Exhaust fan of size 250 mm sweep, 230 volt ACwith connection from existing ceiling rose with louver shutter incl taking out old u/s kept deposit in MES store all as specified and as directed
59S&F exhaust fan metal body heavy duty with louver shutter of sweep 300 mm, 230 volt, SP 1400 RPM with all nut bolt and other accessories with cutting a hole and making good after fixing of exhaust fan including taking out old unserviceable one and depositing to MES store yard completeall as specified and directed. (Make : Havells Cat Part No. Turbojet SPor equivalent as approved by GE)
60S&F exhaust fan metal body heavy duty with louver shutter of sweep 450 mm, 230 volt, SP 1400 RPM with all nut bolt and other accessories with cutting a hole and making good after fixing of exhaust fan including taking out old unserviceable one and depositing to MES store yard completeall as specified and directed.
61S&F AC Single phase static Electronic KWH energy meter of accuracy class 1.0, 240 volt, 50 Hz , with Backlite LCD display ,optical port of rating 10-60 amp 06 months history incl taking out old u/s kept deposit in MES store all as specified and directed (Make : L&T Cat Part No. WM101BC7DDH or equivalent as approved by GE)
62S&F AC Three phase static Electronic KWH energy meter of accuracy class 1.0, 240v, 50 HZ , with Backlite LCD display of rating 10-60 amp six months history incl taking out old u/s kept deposit in MES store all as specified and directed (Make : L&T Cat Part No. WR300BC73BOXH or equivalent as approved by GE)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail