}

E Tender For Medical Machine For Sports Science Center 2022 Third Call- 1 Medical Machines :- 2 Computerized Multi-Treatment Unit :- 1. Should Have More Than 25 Currents Forms, Namely, Unidirectional Currents:- Rectangular Pulse, 2-5 Current ( Ultr, bhopal-Madhya Pradesh

Directorate Sports and Youth Welfare has published E Tender For Medical Machine For Sports Science Center 2022 Third Call- 1 Medical Machines :- 2 Computerized Multi-Treatment Unit :- 1. Should Have More Than 25 Currents Forms, Namely, Unidirectional Currents:- Rectangular Pulse, 2-5 Current ( Ultr. Submission Date for this Tender is 08-09-2022. Medical Equipment Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33677023
E Tender For Medical Machine For Sports Science Center 2022 Third Call- 1 Medical Machines :- 2 Computerized Multi-Treatment Unit :- 1. Should Have More Than 25 Currents Forms, Namely, Unidirectional Currents:- Rectangular Pulse, 2-5 Current ( Ultr
Open Tender
Indian
Madhya Pradesh
bhopal
08-09-2022

Tender Details

E Tender For Medical Machine For Sports Science Center 2022 Third Call- 1 Medical Machines :- 2 Computerized Multi-Treatment Unit :- 1. Should Have More Than 25 Currents Forms, Namely, Unidirectional Currents:- Rectangular Pulse, 2-5 Current ( Ultra Reiz ) , Triangular Pulse, Mf Rectangular Pulse, Ionotophoresis-Mf Rectangular Pulse, Iontophoresis-Direct Current. Diadynamic Currents:- Mf, Df, Cp, Lp. Tens Currents:- Conventional Tens, Low Frequency Tens, Burst Tens, High Frequency Tens, Random Frequency Tens, Han Stim ( Via Pain Relief ) Nmes Currents:- Rectangular Surge, Triangular Surge, Biphasic Surge, Intrapuls Interval Surge, Russian Stimulation, 2-Pole Mf Surge, Isoplanar Vector Field Surge.Interferential Currents:- 2-Pole Mf, Isopalanr Vector Field, Dipole Vector Field, Classical Interferential Micro Currents:- Microcurrent And Microcurrent Surge. 2. Should Have Diagnostic Programs:- Rheobase And Chronaxy, Rheobase And Aq, Diagnostics ( S / D Curves Plotting ) , Pain Points, Diagnose Stress Fracture, Constant Voltage / Constant Current. 3. Should Have 2 Independent Output Channels. 4. Should Have Simultaneous Therapy 5. Should Have Capacitive Touch Screen Monochrome Lcd With Backlight. 6. Should Have 2 Separate Intensity Regulators. 7. Should Have Direct Therapy Keys. 8. Should Have Protocols: Objectives & Indications List 9. Should Have Contra-Indications List, 10. Should Have Memory At Least 50 Free Locations 11. Should Have Ultrasound Treatment Head Small And Large ( Approx 1 Cm² & 4 Cm2 ) 12. Should Have Multi Frequency Treatment Head For Approx. 1& 3 Mhz 13. Should Have Duty Cycle Of 10%, 20%, 30%, 40%, 50%, 100% 14. Should Have Approx Peak Intensity Of0-2 W / Cm2-Duty Cycle 100% And 0-3 W / Cm2 Duty Cycle <100% 15. Should Have Visual And Audio Real-Time Feedback, 16. Should Have Optional Safety Class 3B Laser Product. 17. Should Have Wavelength Of Laser904 Nm, 18. Should Havemax Average Power Of Laserfor Mono Probe More Than- 70Mw -75Mw And For Cluster Probe- 50 To 55 Mw , 19. Should Have Peak Performance Of Laser For Mono Probe Approx-13 W, For Cluster Probe-4X18 W, 20. Should Have Smaller Dimension Approx 250 X 250 X 100 Mm 21. Should Have Optional Rhythm Vacuum Output For Massage Effect 22. Should Have Highest Vacuum Pressure Approx 300 Hpa For Continuous Mode. 23. Should Have Highest Vacuum Pressure Approx 450 Hpa For Pulsation Mode. 24. Should Comply With Medical Device Directive ( Ce 0344 ) 25. Weight Should Not Be More Than 4 Kg. 3 Pneumatic Cryotherapy Unit With Thermal Feedback :- 1. Should Be Able To Provide Flow Of Dry Cool Air 2. There Should Be Intra Equipment Negative Temperatures Up To Approx-300 C 3. There Should Be Ir Sensor For The Purpose Of Treatment Feed Back 4. Therapist Guidance Should Be Available Inbuilt In The Machine 5. There Should Be Bio Feedback Mechanism To Ensure Temperature Feedback 6. Should Have Different Outlet Sizes For Different Areas Like 5, 15 And 25 Mm. 7. There Should Be Adjustable Airflow From 100 To 1000 Litres / Minute In 10 Different Steps. 8. Treatment Arm Rest Should Be Available As Option 9. The Temperature Of The Skin Should Be Measured By The Machine During The Treatment Session 10. The Machine Should Be Able To Provide Constant Skin Temperature By Automatically Adjusting The Airflow As Per The Feedback In Real Time. 11. The Machine Should Have Operating Volume Less Than 72 Dba 12. Flexible Support Arm For Hands Free Application, 13. The Unit Should Be Mobile With Attached Casters 14. There Should Be Inbuilt Indication Lists, Objective Lists And Diagnostic Information 15. The Treatment Head Should Be Rotated 3600, 16. Lcd Screen Should Be Available 17. Maximum Power Should Be 1000Va, 18. The Outlet Hose Should Be Capable Of Attachment With Different Nozzles And It Should Be Having Length Of More Than 1.5M, 19. There Need Not Be Direct Contact With The Outlet And The Patient 20. There Should Be Closed Circuit For Cooling 4 Advanced Multi Treatment Unit With Added Vacuum :- 1. Large ( At Least 10 Inch ) Full-Colour Tft Touch Screen, 2. Ergonomic Design For The Best Possible Comfort 3. 2 Separate Intensity Regulators, 4. Usb Portal For Updating The Protocols, 5. More Than 800 Pre-Programmed Protocols, 6. Electrode Placement Using 3D Pictures, 7. Direct Therapy Keys, Objectives, List Of Indications, Selection By Body Area, 8. Diagnostics, 9. 500 Free Locations In Memory, 10. Integrated List With Contra-Indications, 11.Anatomical Library With Detailed Information About Muscles And Ligaments, 12. Explanation About The Clinical Aspects Of The Treatments With Treatment Suggestions, 13. Information About Electrotherapy Applications With Parameters Explained, 14. These Information Can Be Accessed During Treatment Also, 15. There Should Be Fast And Easy Navigation For Treatment, 16. All Treatments Should Be Evidence Based And There Should Be Options For Future Protocols Which Can Be Added Using Usb, 17. Two Treatments Can Be Given To The Same Area Simultaneously And There Should Be At Least Five Varieties Of Treatments, 18. At Least Two Patients Can Be Treated With The Same Machine Simultaneously, 19. Electrotherapy Unit, • At Least 6 Direct Currents With Pulse Of 0.1Ms To 6S And Intensity Of About 80Ma / V, • All Diadynamic Currents With Intensity Of About 80Ma / V, • 5 Tens Currents With Pulse Of 10-900Ms, Frequency Of 1-500Hz And Intensity Of 120Ma / V, • At Least 6 Nmes Including Monophasic, Biphasic, Russian And Isoplanar Vector • 3 Ift Currents With Varied Combinations With Carrier Frequency Of 2-10Khz And Amf Of Up To 400Hz With At Least 4 Sweeps • Micro Currents And High Voltage Currents, • At Least 7 Diagnostic Programmes, • There Should Be Cv / Cc • Iontophoresis Programme With Complete Details Should Be There, • There Should Be Two Independent Channels If Needed 20. Vacuum Unit • There Should Be Two Vacuum Channels Which Are Independent • There Should Be Continuous And Pulsed Mode • There Should Be Electronic Adjustment Of Vacuum • There Should Be Bipolar Or Quadripolar Mode • There Should Be Massage Mode 21. Ultrasound Unit • Phonophoresis Program Should Be There • Hybrid Ultrasound Heads With Visual And Acoustic Contact Control • Single Head With Both Frequencies • Peak Power Should Be Till 3Watts Per Cm / 2 • Treatment Time Till Half An Hour 22. Laser Unit, • Wavelength 904Nm • Treatment Time Till Half An Hour • Peak Performance Above 12 W • Maximum Average Power More Than 70Mw • Maximum Average Power More Than 50Mw For Cluster Probe • Peak Performance More Than 16 W For Cluster Probe 23. There Should Be Therapist Guidance System 24. There Should Be Pen For The Touch Screen And Vas Score 5 Combination Unit For Emg Feedback, Pressure Feedback And Electrotherapy:- • Should Have Possibility To Combine Electro Stimulation With Emg Or Pressure Feedback. • Should Have 2-Channel Emg Feedback. • Target Capture Function Independently For Both Channels. • Possibility For The Registration Of Maximum, Minimum And Average Measuring Results. • Possibility To Increase Resolution Around Captured Target During Measurement Process ( On Both Channels ) . • Audio Signal ( Adjustable ) Upon Achieved The Target Value. • Stimulation And Relaxation Mode Function. • Should Have One Pressure Feedback In Range 0-1000 Mmhg For Absolute Input And 0-750 Mmhg For Relative Input. • 2 Independent Electrotherapy Channels For Rehabilitation, Muscle Strengthening, Pain Management ( Direct Current:- Rectangular Pulse, 2-5 Current ( Ultra Reiz ) , , Diadynamic Currents:- Mf, Rs, Df, Cp, Lp, Tens Currents:- Conventional Tens, Low Frequency Tens, Burst Tens, Brief Intense Tens, Random Frequency Tens, Nmes Currents:- Rectangular Surge, Triangular Surge, Biphasic Surge, Intrapuls Interval Surge, Russian Stimulation, 2-Pole Mf Surge, Isoplanar Vector Field Surge, Interferential Currents:- 2-Pole Mf, Isopalanr Vector Field, Dipole Vector Field, , Iontophoresis, Diagnostics. • Should Have More Than 80 Treatment Indications. • Should Have Facility For Treatment By Setting Objectives ( Viz. Sequential And Conventional Programs ) • Should Have Facility Of At Least 20 Free Memory Slots To Store Your Own Programs. • Should Be Supplied With Complete Range Of Probes For Emg Feedback And Electro Stimulation And Pressure Feedback ( Anal Or Vaginal ) Probes, Surface Electrodes For Emg-Feedback, Rubber Or Adhesive Electrodes For Electro Stimulation. • Should Have Software Pack To Connect With Computer Or Laptop To Display, Store Review And Print Complete Treatment Biofeedback Session On Computer. 6 Three Section Treatment Couch :- Memory Function: Three Programmable Settings For Height Adjustment, Bluetooth Wireless Operation Ergomax:Pu Foam, Closed Skin, Low Density 5° Shore Cushion Heating: 34 °C, 36 °C And 38 °C Battery Function: Li-Ion 25, 9 Vdc, 2, 25 Ah Motor Force:8 Kn Motor Usage:Max. 2 Minutes / 18 Minutes Off Hydraulic Pump:10 Kn Frame Material:Steel Frames Conformity:Iec / En 60601-1:2013 Ed. 3.1 Dimensions:206 X 67 Cm Weight:99 Kg Height Adjustment:± 47 – 97 Cm Lifting Capacity:Max. 200 Kg Mains Voltage:100 - 240 Vac, 50 - 60 Hz Current:Max. 3.0 A Standby Power Consumption:Max. 3 W Insulation: Class Ii Applied Parts: Type Bf 7 Thermal Short Wave Diathermy :- • Should Be A Medical Application Of Electromagneticenergy • Should Have The Following Indications:- • Chronic Musculoskeletal • Acute Soft Tissues • Circulatory Complaints • Should Have Continuous & Pulsed Short Wave Therapy In One Device. • Should Have Optimal Performance In Both Modes With Two 100 Mm Electrodes • Should Have Optional Monopulse Applicator, For Use In Pulsed Mode • Should Have Colour Touch Screen For Use With Surgical Gloves • Should Have Clear User Interface Allows For Quick Set-Up • Should Have On Screen User Assistance & Pictorial Guidance With Clinical Protocols • Should Have Wide Range Of Pulse Frequencies & Widths • Should Have Operation In Continuous & Pulsed Mode • Should Have Output Automatically Tunes With The Patient • Frequency: 27, 12 Mhz • Output Power: 400 W Maximum In Continuous Mode; • 1000 W Maximum Peak Power In Pulsed Mode • Output Modes: Continuous, Pulsed 1 In 3, 2 In 3 & 3 In 3 • Classification: Class 1 • Type: Bf ( En 60601-1 ) • Pulse Width: 20 - 400Μs • Pulse Frequency: 5 - 800 Pulses Per Second • Tuning: Automatic • Timer: 0 - 30 Minutes With Termination Of Output & Alarm Atend Of Treatment • Mains Supply: 100-240 Vac, 1Kva Max, 50 / 60Hz • Size: 470 X 470 X 940 Mm ( L X W X H ) Approx • Weight: 38 Kgapprox • Should Be Ce Certified

Key Value

Document Fees
INR 3000 /-
EMD
INR 140000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail