Supply , Installation Of New Vrv Acs With Buyback Of Old Vrv System At Iocl, Marketing Head Office, Mumbai Supply , Installation Of New Vrv Acs With Buyback Of Old Vrv System At Iocl, Marketing Head Office, Mumbai , Supply Of Variable Refrigerant Air Conditioners ( Please Refer Annexure For Technical Specification Details) Outdoor/Indoor Units , For Vrv Outdoor Units (10 Hp) , For Hi-Wall Ac Unit ( 2Tr) Withwireless Remote Controller , For Hi-Wall Ac Unit (1.5Tr) Withwireless Remote Controller , For Cassette Unit ( 4Tr) Withwireless Remote Controller , For Cassette Unit ( 3Tr) Withwireless Remote Controller , Refnets Joints (Insulated With Aerotape) , Supply Of Refrigerant Control Y / Tee Joints With Insulation For Piping (Refnets) , Refrigerant Piping , Supplyof Copper Refrigerant Suction Linewith 19 Mm Or Better Thick Rubber Nitrile Tubular Insulation. , Supply Of Copper Refrigerant Liquid Line With 19 Mm Or Better Thick Rubber Nitrile Tubular Insulation. , Control Cabling , Supplyof Control Cabling (2 Core X 1 Sq. Mm Copper Cable) From Indoor Units To Outdoor Units With Hard Pvc Conduit Including Cable Required From Outdoor Unit To Central Controller. , Controller : Supplyof Central Controller For Controlling All The Indoor And Outdoor Unitsand Should Be Capable Of Integration With Bms System. All The Outdoor/Indoor Unit Parameters Shall Be Integrated Through Bms & Required Hardware/Software To Be Included Via Modbus/Bacnet. , Supplyof Drain Pipes With Thermal Insulation , 25Mm Or Better Pvc Hard Pipe , 32Mm Or Better Pvc Hard Pipe , 40Mm Orbetterpvc Hard Pipe , Miscellaneous Fittings And Accessories , Supply Of Suspension Rods With Cleat Angle To Hang The Indoor Units , Supply Of Refrigerant Charging With R-410 Gas ( Or Better )For Commissioning Of Vrv System , Supply Ofms Stands For Indoor & Outdoor Units With Rubber Pads &The Frame Should Be Painted Hot Dip Galvanised For Outdoor Units Ms Framework For Outdoor Unit With Epoxy Painting(Platform Stand) , Supplyof Anti Corresive Coating For Outdoor & Indoor Unit As Per Oem Approved Make. , Supplyof Hot Dip Galvanised Perforated Cable Trays With Cover (600 X 100)Mm , Supplyof Hot Dip Galvanised Perforated Cable Trays With Cover (150 X 100)Mm , Electrical Work , Supply Of Mcb Isolator Enclosure(Wheather Proof Box)- For Outdorr Unit , Supplyof Mcb & Elcb For Outdoor Unit As Per Oem Standard . , Supplyof Power Cable From Panel To Outdoor Isolator And Unit.(4 Core X 6 Sq Mm Copper Armoured Xlpe Cable/ As Per Oem Standard) , Controller : Supplyof Central Controller For Controlling All The Indoor And Outdoor Unitsand Should Be Capable Of Integration With Bms System. All The Outdoor/Indoor Unit Parameters Shall Be Integrated Through Bms & Required Hardware/Software To Be Included Via Modbus/Bacnet. Standard Installation, Testing & Commissioning Charges For Vrv , For Vrv Outdoor Units (10 Hp) , For Hi-Wall Ac Unit ( 2Tr) , For Hi-Wall Ac Unit (1.5Tr) , For Cassette Unit ( 4Tr) , For Cassette Unit ( 3Tr) , Refnets Joints (Insulated With Aerotape) , Installation Of Refrigerant Control Y / Tee Joints With Insulation For Piping (Refnets) , Refrigerant Piping , Installation Of Copper Refrigerant Suction Line As Per Oem Standard With 19 Mm Or Better Thick Rubber Nitrile Tubular Insulation. , Installation Of Copper Refrigerant Liquid Line As Per Oem Standard With 19 Mm Or Better Thick Rubber Nitrile Tubular Insulation. , Control Cabling , Installation Of Control Cabling (2 Core X 1 Sq. Mm Copper Cable) From Indoor Units To Outdoor Units With Hard Pvc Conduit Including Cable Required From Outdoor Unit To Central Controller. , Controller: Installation For Central Controller For Controlling All The Indoor And Outdoor Unitsand Should Be Capable Of Integration With Bms System. All The Outdoor/Indoor Unit Parameters Shall Be Integrated Through Bms & Required Hardware/Software To Be Included Via Modbus/Bacnet. , Installation Of Drain Pipes With Thermal Insulation , 25Mm Or Better Pvc Hard Pipe , 32Mm Or Better Pvc Hard Pipe , 40Mm Or Better Pvc Hard Pipe , Miscellaneous Fittings And Accessories , Installation Of Suspension Rods With Cleat Angle To Hang The Indoor Units , Refrigerant Charging With R-410 Gas ( Or Better ) For Commissioning Of Vrv System , Installation Ofms Stands For Indoor & Outdoor Units With Rubber Pads &The Frame Should Be Painted Hot Dip Galvanised For Outdoor Units Ms Framework For Outdoor Unit With Epoxy Painting(Platform Stand) , Lifting, Shifting And Location For Outdoor Unit , Indoor Unit And Other Accessories(Without Considering Crane). , Installation Of Anti Corresive Coating For Outdoor & Indoor Unit As Per Oem Approved Make. , Installation Of Hot Dip Galvanised Perforated Cable Trays With Cover : (600 X 100)Mm , Installation Of Hot Dip Galvanised Perforated Cable Trays With Cover : (150 X 100)Mm , Civil Work - Civil Works Includes Wall Cut Out & Core Cutout And Finishing With Same Material To Run The Refrigerant Pipes, Power Cables & Cable Trays Etc., Floor Tail Alignment, Cutting, Cleaning Etc. And Any Other Civil Works Requried For Commissioning Of New Vrv System.Vendor Should Ensure Minimal Civil Work In The Best Possible Way For Completion Of Job. , Electrical Work , Electrical Works For Proposed Inrow Cooling Units Including Works Of Tapping From Existing Panels, Split Panels, Breakers, Cables, Cable Trays With Support And Other Accessories To Complete The System. , Installation Of Mcb Isolator Enclosure(Wheather Proof Box)- For Outdorr Unit , Installation Of Mcb & Elcb For Outdoor Unit As Per Oem Standard . , Installation Of Power Cable From Panel To Outdoor Isolator And Unit.(4 Core X 6 Sq Mm Copper Armoured Xlpe Cable/ As Per Oem Standard) , Other Important Work , Dismentaling Of Existing Vrv System , Project Management And Governance , Comprehensive Vrv For Above Vrv Works , 2Nd Year And 3Rd Year Comprehensive Amc After 1 Year Standard Warranty , Buy Back Price , Buyback Of Existing Vrv System( 6 Outdoor Unit , 17 Indoor Units )