| 1 | Civil Work. |
| 2 | 2.13 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of Soil. |
| 3 | 2.19 Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | 10.3 Providing and laying dry flat brick flooring in required pattern complete. |
| 5 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level.4.1.13 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) |
| 6 | 6.1 First class brick work in foundation and plinth including cost of all materials as required complete:-6.1.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 7 | 6.3 First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-6.3.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 8 | 12.1 12 mm cement plaster of mix.12.1.2 Cement mortar 1:4 (1 cement : 4 fine sand) |
| 9 | 12.5 Neat cement punning. |
| 10 | 12.4 6 mm cement plaster of mix : |
| 11 | 12.215 mm cement plaster on the rough side of single or half brick wall of mix:12.2.2 Cement mortar 1:4 (1 cement : 4 fine sand) |
| 12 | 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level:5.1.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-5.2.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-5.3.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 15 | 5.19 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete uptoplinth level.5.19.4 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | 5.8 Centering shuttering including struttings, propping etc. and removal of form work for:5.8.1.1 Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 17 | 5.8.6.2Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 18 | 5.8.4.2 Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 19 | 5.8.5.2 Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
| 20 | 6.29 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 21 | 7.2 Providing and fixing gangsawcutofapproved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 ( 1 cement : 4 fine sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing , curing, moulding and polishing to edges to give high gloss finish etc.complete at all levels:-7.2.1 18 mm thick Rajnagar Plain white marble/ Udaipur green marble/ Zebra black marble or equivalent duly approved:-7.2.1.1 Area of slab upto 0.50 sqm. |
| 22 | 16.1 Providingandfixingaluminiumworkfordoors,windows,ventilators and partitions withextrudedbuiltupstandardtubularsections/ appropriateZsectionsandothersectionsofapprovedmake conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawingandthedirectionofEngineerincharge.(Glazingand paneling and dash fasteners to be paid for separately) :-16.1.1 For fixed portion of approved quality:-16.1.1.1 Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
| 23 | 16.1 Providingandfixingaluminiumworkfordoors,windows,ventilators and partitions withextrudedbuiltupstandardtubularsections/ appropriateZsectionsandothersectionsofapprovedmake conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawingandthedirectionofEngineerincharge.(Glazingand paneling and dash fasteners to be paid for separately) :-16.1.2 For shutters of doors, windows & ventilatorsincluding providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):-16.1.2.1 Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
| 24 | 6.12 Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-6.12.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 25 | 16.3 Providing and fixing glazing of approved quality in aluminium doors,windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-16.3.2 With float glass panes of 5.5 mm thickness ( weight not less than 13.50 kg / sqm ). |
| 26 | 11.42 ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwater pipes (working pressure 4 kg/cm2)conformingto IS : 13592 Type Aincludingjointingwith sealring conformingtoIS:5382leaving10mmgapforthermalexpansion:11.42.2 Single socketed pipe - 110 mm OD. |
| 27 | 12.31 Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.31.1 New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 28 | 12.23 Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 29 | 12.47 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: 12.47.1 Two or more coats on new work. |
| 30 | 8.82 Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessaryaccessories and screws etc. complete. |
| 31 | 8.99 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.8.99.2 Twin rubber stopper. |
| 32 | 8.95 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :8.95.2 250x10 mm. |
| 33 | 8.98 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :8.98.1 125 mm. |
| 34 | 8.94 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :8.94.1 300x16 mm |
| 35 | 10.55 Providing and fixing precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning complete as per direction of the Engineer-in-Charge. |
| 36 | 8.46 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.8.46.2 Fixed to openings /wooden frames with rawl plugs screws etc. |
| 37 | 2.16 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of Soil. |
| 38 | 9.2 Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required. |
| 39 | 16.25 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: 16.25.2 Aluminium Composite Panels of 3mm total thickness with Top coil – 0.25mm AA3003 Grademanufactured as per IS-737 1986, FR Grade Class B1 with 2.50mm Mineral Core with minimum 70-72% Inorganic content (Aluminium Hydroxide and Magnesium Hydroxide) 28-30% Organic content (LDPE) conforming to ASTM E-119-16,18 and EN 13501 - 1 class B1 and Bottom coil – 0.50mm AA3003 Grademanufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coatingconforming to AAMA2605 on top coil and Service coating on Back Coil (4 - 6 microns) having minimum panel weight of 5.25 Kg/m2. |
| 40 | 3 mm Retro reflective sheet including lettering (for sign board). |
| 41 | Mechanical Work. : Supply, installation, testing and commissioning of Electric Cremation Furnace with vertical heater assembly including five years comprehensive operation & maintenance. |
| 42 | Providing & fitting fixing of furnace casing, double wall type fabricated from finest steel, duly painted with heat resistant aluminium paint or powder coating. (75 mm MS channel or square tube in double wall frame and SS 304 decorative sheet) complete as per direction of the Engineer-in-Charge. |
| 43 | Providing & fitting fixing of refractory and insulation for furnace lining with necessary cement, ceramic fiber insulation and calcium silicate board for insulation of furnace etc. (refractory with 42% to 63% high alluminahigh seral block for insulation, ceramic blanket, hot & cold phase bricks and bider) complete as per direction of the Engineer-in-Charge. |
| 44 | Providing & fitting fixing motorised door made of M.S with internal insulation with ceramic blanket and allied eqipment motorised door drive arrangement including 0.5 HP motor, gear box, chain,sprocket, counter weight, limit swich & clutch arrangement & arrangement of manual opperation etc. complete as per direction of the Engineer-in-Charge |
| 45 | Providing & fitting fixing of stainless steel vertical wet scrubber alongwith water recirculation pump, water tank duly llined with FRP piping. ( ventury serubber to control air pollution with capacity 150mg/hr, 3mm thickness AISI SS304 plate, spray nozzle mist separator and damper etc.complete as per direction of the Engineer-in-Charge |
| 46 | Providing & fitting fixing of stainless steel ducting from furnace to scrubber and scrubber to Chimney of SS 304 of dia 300/322mm with necessary flanges dampers and SS hardware etc.complete as per direction of the Engineer-in-Charge. |
| 47 | Providing & fitting fixing of fresh air arrangement including blower, centrifugal type with minimum1 HP motor, 600 CFM discharge capacity, distribution chamber, necessary valves etc.complete as per direction of the Engineer-in-Charge. |
| 48 | Providing & fitting fixing of trolly with ellectro mechanical operation along with facillity of autometic UP - DOWN and reverse 07 forward for smooth charging of body inside furnace along with its rails and accessories etc.complete as per direction of the Engineer-in-Charge. |
| 49 | Providing & fitting fixing of vertical heaters bundled with rod type made of 80-20 Ni-Cr / Cr wire with protected by APN Radiant tube etc.complete as per direction of the Engineer-in-Charge. |
| 50 | Providing & fitting fixing of Electrical control panel with 14swg sheet metal enclosure painted with anti-corrosive paint in/c thuster power regulator with PID temparature controller with contactor with change over swich and also necessary cables. Electrical devices etc. complete as per direction of the Engineer-in-Charge. |
| 51 | Providing & fitting fixing of cable from source to control panel & control panel to furnace and others motors, earthing with all earthing materials etc. complete as per direction of the Engineer-in-Charge. |
| 52 | Providing & fitting fixing of MS fabricated water tank size of 1375 (H) x 1500(L) x 1000 (W) with FRP coating in/c necessary inlet/outlet pipeline & valves etc.complete as per direction of the Engineer-in-Charge. |
| 53 | Providing & fitting fixing of foot mounted exhaust blower in SS 304 with 10 HP motor in/c damper, centrifugal type 1200 CFM discharge capacity etc. complete as per direction of the Engineer-in-Charge. |
| 54 | Providing & fitting fixing of 2HP Slug pump (Crompton / Kirloskar make) with necessary pipe, pipe fittings, flange etc. complete as per direction of the Engineer-in-Charge. |
| 55 | Providing & fitting fixing of 30 mtr self supporting chimney along with ladder and platform upto sampling point, aviation lamp, and lightning arresters, chimney should include earting provision and foundation bolts nut of adequate size etc. complete as per direction of the Engineer-in-Charge. |
| 56 | Construction of chimney foundation 2600mm x 2600mm x 2000mm, R-25 grade RCC TMT 10 to 16 mm dia including fitting fixing of stud bolt of chimney with acquarate measurement as per manufacturer design and drawing complete as per direction of the Engineer-in-Charge. |
| 57 | Providing installation and commissioning of 125KVA generator with diesel driven engine, kirloskar/ cummins make complete as per direction of the Engineer-in-Charge. |