Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Construction Of Pump House / Panel Room / Operator Room At Water Supply Scheme Shiganpora- 1 (Part A) WSS Shiganpora(Electro-Mechanical)(Adv. Cost: Rs. 12,10,00, Kulgam-Jammu And Kashmir

Public Health Engineering Department-PHED has published Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Construction Of Pump House / Panel Room / Operator Room At Water Supply Scheme Shiganpora- 1 (Part A) WSS Shiganpora(Electro-Mechanical)(Adv. Cost: Rs. 12,10,00. Submission Date for this Tender is 08-11-2022. Pump House Construction Tenders in Kulgam Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

33664795
Corrigendum : Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Construction Of Pump House / Panel Room / Operator Room At Water Supply Scheme Shiganpora- 1 (Part A) WSS Shiganpora(Electro-Mechanical)(Adv. Cost: Rs. 12,10,00
Open Tender
Indian
Jammu And Kashmir
Kulgam
08-11-2022

Tender Details

Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Construction Of Pump House / Panel Room / Operator Room At Water Supply Scheme Shiganpora- 1 (Part A) WSS Shiganpora(Electro-Mechanical)(Adv. Cost: Rs. 12,10,000/-) 2 Supply, Installation, Testing & Commissioning of Submersible Pumping Unitas per IS 8034 with following specification are as under:PUMP : Efficiency = Not less than 50% Speed= 2900 RpmType of pump = Mixed flow.Type of fluid to be handled=Clear WaterMATERIAL OF CONSTRUCTION:Impeller= Stainless SteelPump Shaft = Stainless Steel SS 410.Pump Casing = Cast Iron/Stainless steelMOTOR:-Method ofstarting = Star – DeltaSpeed = 3000 (Sync).Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phaseEfficiency = Not less than 90%Rating: 10 HPManufacture test certificate to be appended. Rest ofspecification as per Cluase 1of technical anexure of SBD 3 Fabrication, providing, fitting and lowering of 65mm diameter B Class (Medium class) column pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia l. production well/Dug Wel up to the desired depth ; The job includes Providing and welding of flanges conforming toIS: 6392, Table-05 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange. 4 Fabrication, providing and fitting of 65 mm size split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. (02 Pair) 5 Fabrication, Providing and fitting of90-120 degree bend/elbowto be fabricated out of80 mm diameter Class-C, G.I pipe, 1 m lengthand flanged on both ends andto make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 05 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. 6 Providing and fitting of 300mm in length 80mm dia GIreducerflanged on both sides, flange conforming to Table-05 (PN16) to be fitted with the column pipe/delivery manifold of submersible pumping unit to join Rising-main and column pipe/delivery manifold. The flange welding shall be carried out in double layers using reputed make electrodes from inside and outside of pipe to form strong welding joint. 7 Fabrication, providing and fitting of 80mm dia washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. 8 Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/sluice valves as per IS14846 for regulating the water supply outside the pumping units .The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDMrubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible forburied applications and shall be safe to install in both horizontal and vertical positionsRest specification as per cluase 12 of SBD. Size: DN80PN:1.6/16 9 Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDMrubber(Approved for drinking water).Rest specification as per cluase 13 of SBD. Size: 80mmPN: 1.6/16 10 Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded 11 Earth work in excavation required for installation ofGantry mechanismand associated worksby manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed in all kinds of soil. 12 Providing and laying of soling stone 13 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. all work upto plinth level with 1: 2 : 4 (1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size). 14 painting of the 2 no. gantry and plate form of wellusing one coat of red oxide metal primer and two coats of enamel paintof different shades 15 Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features Capacity=2 ton (P)No. Of load chain falls = 2 or above Min. Height of lift = 6 M Detailed Techinical specification as per cluase 24 of SBD 16 Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps 17 Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. 18 Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . 19 Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing, Station Type . 20 Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creepagedistance 320 mm 21 Providing and fitting of ACSR as per IS 398 (part-2) 1996 0.05 ACSR (Galvanised steel reinforced. 22 Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class: IP-55 & fitted with accessories as under:Rating = 10 HP Rest specifications as per cluase - 43-Bof SBD 23 Providing, fitting, testing and commissioning of 40 KVA voltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step.Type of Regulator: Double plate type with electrolytic copper contacts.Input voltage : 175-400 volts.(3 phase)Output voltage : 400 ±10% volts.Frequency : 50±3 C/S.Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried.Insulation : Fiber glass insulations to tested parameters.Cooling: Naturally, Oil cooledTemp. Rise (Max) : 30°C above ambientMounting : On Uni-directional wheels.Correction rate : 30 volts per stepWave form distortion: virtually nilDuty cycle : 100% continuous.Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators.Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations.Load: Three phase induction motor load.Load Amperes (continuous) Rest ofTechnical specification as per Cluase 45of technical anexure of SBD 24 Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc.NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only.i) 50 sqmm, 3.5core 25 Providing and fitting of 3-Core flat 10 sq.mm submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. 26 P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size :80 mm dia, Length :2000 mmBack fill compound :30 kg 27 Supply, installation of 6 kg co2 type fire extinguisher manufactured as per IS:15683 OF 2006 with IS mark and comply with DGMS(Approval) . The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipments. the cylinder used for fire extinguisher shall be approved by protroleum andexplosive safety organization(PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS:7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS : 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. 28 Supply, installation, Testing & commissioning of 1000 VA Full Sine wave power inverter (Make: Microtek/Luminous) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Amaron /Exide) with 2-core 4mm2 Cu(25 mtr)wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. 29 TOOL KIT For Maintenance: -The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of:Providing of tool kit consists of following items Rest specifications as per clause- 56 of SBD 30 Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded 31 Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint 32 Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6x3 (6Kg)- 02 No’sii) Quilt with warm cover size 5x8 (6Kg)- 02 No’sRest specifications as per clause -57 of SBD 33 Electrification of pump house by way of P/f of:- Lighting points in 1.0 Sq.mm multistrand PVC chanel/condut.The job incl. P/F of 5 Amp. Switch,angle/button holder,5 watt LED lamp with necessary fixtures (06 jobs). Heating points in 2.5 Sq.mm multistrand PVC insulated copper conductor to be laid/carried in pvc channel/condut.The job includes P/f of 16 amp.SS combine (04 jobs). 5 pin socket points in 1.5 Sq.mm multistrand PVC insulated copper conductor to be laid/carried in PVC channel/conduit.(04 Jobs).Cealing Fan c/w regulator switch,wiring in1.5 sq.mm multistrand Pvc insulated copper conductor to be laid/carried in PVC channel/conduit and necessary fixtures (02 Jobs).Distribution Board SP &N(Regal Grey) with 01 No incomming and 8 way outgoing,fitted with mini MCBc series 6Amp.-04 no for lighting points and2/3 pin socket points and fans,10 amp-01 No for flood lights,16 amp-01 no for heating points,36 amp.MCB (Mains) as per IS standard.The fittings shall be Modular type. 34 Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. 35 Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) 36 Providing of 1 KW heat convector for operators for winter season. 37 Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size: 6’×1’6” = 9 sft 38 Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site.Size: 4’×6’ out MS ANGLE OF 40X 40X 5of 36 rft and MS sheet of 1 mmthicktotal weight of50.16 kgs 39 (Part B) Pump House of WSS Shiganpora (Adv. Cost Rs. 18,50,000/-) 40 Earth work in excavation over areas exceeding 30 cm and upto 1.5 m in depth 1.5 m in width as well as 10 sqm on plan inculding disposal of excavated soil upto1mt from cutting edge. 41 Extra for earth work for every additional lift of 1.5 M or part thereof 42 Providing and laying of dry stones soling tightly hand packed. 43 Provding and laying of 1:4:8 nominal mix cement concrete. 44 R.R masonary with quarry stone laid in 1:6 CM 45 R.R masonary with quarry stone laid in 1:6 dry 46 Providing and laying of 50 mm thick DP band over stone work in 1:2:4 nominal mix 47 Brick work with ommon brunt clay F.P.S bricks of class designation 75 in foundation and plinth in 1:6 CM. 48 Extra over Brick in super structure up to floor V level. 49 Providing and fixing of wooden chowkat in first class kail wood. 50 Providing and fixing of 35mm thick glazed shutters for doors and windows First class kail wood. 51 Providing and fixing panelled or panelled andglazed shutters for doors and windows 35mm thick of Kail wood. 52 Providing and fixing of panelling or penelling and glazing in panelled or panelled and glazed shutters for doors and windows ; penelling 25mm to 40mm thick of Kail wood. 53 Providing and fixing of 35mm thick wire guage shutters for doors and windows. 54 Reinforced cement concrete work in 1:2:4 nominal mix with 20mm N/S stone aggregate. 55 Providing Reinforcement to the RCC works including bending, binding, cutting placing in position complete. 56 Centering and shuttering including proping, struting etc and removal of farm work.Lintel / V beam 57 Slab 58 Slab edges 59 Providing 50mm thick cement concrete flouring with floating coat of neat cement. 60 12mm thick cement sand plaster in 1:4 mix 61 1:3 mix with floating coat of neat cementfor saptic tank. 62 Providing and fixing 1st quality ceramic glazed tiles with minimum thickness 5mm of approved make like Kajaria, Somany etc. over 12mm thick cement mortar in 1:3 mix. 63 Providing and laing / fixing ceramic glazed floor tiles 300x300mm of 1st class of Somany or Kajaria or equilent made laid on 20mm thick bed of lcement mortar in 1:4 mix. 64 Providing and fixing water closet squarting pan (Indian type with 100mm sand cast iron P or S trap, 10 lit, low level PVC flusingcistern including flushing pipe and making good the walls and floors wherever required (Orrisa pattern with intergral foot type). 65 Providing and fixing salem stainless steel kitched sink. Size 610x510x200mm 66 Providing and fixing of PVC wasit pipe sink including PVC waist fititng complete (flexable 40 mm dia = 1 No) 67 Providing and fixing of sanitary fititng 68 Structual steel works welded in built up section, trusses and framed works including cutting hoisting, fixing in position and applying priming coat of approved steel primer complete. 69 Providing and fixing corrogated G.S Sheets including vertical/curved surfaces with polymer coated J or L hooks (0.63 mm thick) 70 Providing ridge or hip of width 60cm over all with plain GS sheets fixed with polymer coated J or L hoors (0.63 mm thick) 71 Providing and fixing of coloured eves boarding 72 Providing and fixing of 12 mm thick plyboard soffit along wiith supporting of frist class popular wood ballies. 73 Supplying and fixing rolling shutter of approved make made of required size MS lathes interlocked together through their entire length etc complete with 80x0.90 mm MS laths with 0.90 mm thick top cover. 74 Providing and applying white cement based putty of approved thickness 1mm of approved brand and manufacture over the plastered surfaces to prepare the surface smooth and even complate. 75 Distempering lwith 1st quality acrylic distemper of approvedbrand and manufacture including applyingadditional lcoats whereever required to achive even shade. (Two Coats) 76 Finishing walls with water proofing cement paint of required shade (external) (Snowsum) 77 Painting with synthetic enamal paint ofapproved brand and manufacture of required colour to give even shade two or more coats on new work includingpriming coat of approved brand and manufacture.a) wood works 78 b) on steel work 79 Add. Provision for plumbing, and electrification to the quarter 80 Carriage of material from source to dumping site at road by Mechanical transport a) Cement and steel for average lead of 21 (Km) 81 b) Sand for average lead of 22 (Km) 82 c) 20mm Aggregate for average lead of 22 (Km) 83 c) 40mm Aggregate for average lead of 22 (Km) 84 e) Bricks for average lead of21 (Km) 85 f) Quarry stone for average lead of20 (Km) 86 g) Soling stone for average lead of21(Km) 87 Extra carriage of material from dumping site actual site by mannual labour.a) Cementfor average lead of 400 (mts) 88 b) Steel for average lead of 400 (mts) 89 c) Sand & 20mm Agg. for average lead of400 (mts) 90 c) 40mm Agg. for average lead of400 (mts) 91 e) Bricks for average lead of 400 (mts) 92 f) Quarry stone for average lead of400 (mts) 93 g) Soling stone for average lead of 400 (mts)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Sep-2022 Corrigendum Technical Bid 15-09-2022
2 16-Sep-2022 Extension Notice Date 23-09-2022
3 17-Sep-2022 Corrigendum for Modification Technical Bid 23-09-2022
4 24-Sep-2022 Extension Notice II Date 04-10-2022
5 28-Sep-2022 Corrigendum II Technical Bid 04-10-2022
6 05-Oct-2022 Extension Notice c Date 17-10-2022
7 18-Oct-2022 Extension Notice 5 Date 31-10-2022
8 01-Nov-2022 Extension Notice V Date 08-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 61200.0 /-
Tender Value
INR 30.60 Lakhs /-

BOQ Items

Name of Work: Supply, installation, testing and commissioning of electro-mechanical equipments and construction of pump house/Panel room/ Operator room at water supply scheme Shiganpora under JJM.
Sl. No. Item Description
1(Part A) WSS Shiganpora(Electro-Mechanical)(Adv. Cost: Rs. 12,10,000/-)
2Supply, Installation, Testing & Commissioning of Submersible Pumping Unitas per IS 8034 with following specification are as under: PUMP : Efficiency = Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller= Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Rating: 10 HP Manufacture test certificate to be appended. Rest ofspecification as per Cluase 1of technical anexure of SBD
3Fabrication, providing, fitting and lowering of 65mm diameter "B" Class (Medium class) column pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia l. production well/Dug Wel up to the desired depth ; The job includes Providing and welding of flanges conforming toIS: 6392, Table-05 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange.
4Fabrication, providing and fitting of 65 mm size split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. (02 Pair)
5Fabrication, Providing and fitting of90-120 degree bend/elbowto be fabricated out of80 mm diameter Class-C, G.I pipe, 1 m lengthand flanged on both ends andto make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 05 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement.
6Providing and fitting of 300mm in length 80mm dia GIreducerflanged on both sides, flange conforming to Table-05 (PN16) to be fitted with the column pipe/delivery manifold of submersible pumping unit to join Rising-main and column pipe/delivery manifold. The flange welding shall be carried out in double layers using reputed make electrodes from inside and outside of pipe to form strong welding joint.
7Fabrication, providing and fitting of 80mm dia washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I " C-class "pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends.
8Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/sluice valves as per IS14846 for regulating the water supply outside the pumping units . The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDMrubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible forburied applications and shall be safe to install in both horizontal and vertical positionsRest specification as per cluase "12" of SBD. Size: DN80 PN:1.6/16
9Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). Rest specification as per cluase "13" of SBD. Size: 80mm PN: 1.6/16
10Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded
11Earth work in excavation required for installation ofGantry mechanismand associated worksby manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed in all kinds of soil.
12Providing and laying of soling stone
13Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. all work upto plinth level with 1: 2 : 4 (1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size).
14painting of the 2 no. gantry and plate form of wellusing one coat of red oxide metal primer and two coats of enamel paintof different shades
15Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features Capacity=2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Detailed Techinical specification as per cluase 24 of SBD
16Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps
17Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs.
18Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation .
19Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing, Station Type .
20Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creepagedistance 320 mm
21Providing and fitting of ACSR as per IS 398 (part-2) 1996 0.05" ACSR (Galvanised steel reinforced.
22Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class: IP-55 & fitted with accessories as under: Rating = 10 HP Rest specifications as per cluase - 43-Bof SBD
23Providing, fitting, testing and commissioning of 40 KVA voltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 175-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Rest ofTechnical specification as per Cluase 45of technical anexure of SBD
24Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. i) 50 sqmm, 3.5core
25Providing and fitting of 3-Core flat 10 sq.mm submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size.
26P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size :80 mm dia, Length :2000 mm Back fill compound :30 kg
27Supply, installation of 6 kg co2 type fire extinguisher manufactured as per IS:15683 OF 2006 with IS mark and comply with DGMS(Approval) . The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipments. the cylinder used for fire extinguisher shall be approved by protroleum andexplosive safety organization(PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS:7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS : 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO.
28Supply, installation, Testing & commissioning of 1000 VA Full Sine wave power inverter (Make: Microtek/Luminous) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Amaron /Exide) with 2-core 4mm2 Cu(25 mtr)wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.
29TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of: Providing of tool kit consists of following items Rest specifications as per clause- 56 of SBD
30Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded
31Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint
32Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’s ii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’s Rest specifications as per clause -57 of SBD
33Electrification of pump house by way of P/f of:- Lighting points in 1.0 Sq.mm multistrand PVC chanel/condut.The job incl. P/F of 5 Amp. Switch,angle/button holder,5 watt LED lamp with necessary fixtures (06 jobs). Heating points in 2.5 Sq.mm multistrand PVC insulated copper conductor to be laid/carried in pvc channel/condut.The job includes P/f of 16 amp.SS combine (04 jobs). 5 pin socket points in 1.5 Sq.mm multistrand PVC insulated copper conductor to be laid/carried in PVC channel/conduit.(04 Jobs).Cealing Fan c/w regulator switch,wiring in1.5 sq.mm multistrand Pvc insulated copper conductor to be laid/carried in PVC channel/conduit and necessary fixtures (02 Jobs).Distribution Board SP &N(Regal Grey) with 01 No incomming and 8 way outgoing,fitted with mini MCB"c" series 6Amp.-04 no for lighting points and2/3 pin socket points and fans,10 amp-01 No for flood lights,16 amp-01 no for heating points,36 amp.MCB (Mains) as per IS standard.The fittings shall be Modular type.
34Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply.
35Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each)
36Providing of 1 KW heat convector for operators for winter season.
37Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size: 6’×1’6” = 9 sft
38Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. Size: 4’×6’ out MS ANGLE OF 40X 40X 5of 36 rft and MS sheet of 1 mmthicktotal weight of50.16 kgs
39(Part B) Pump House of WSS Shiganpora (Adv. Cost Rs. 18,50,000/-)
40Earth work in excavation over areas exceeding 30 cm and upto 1.5 m in depth 1.5 m in width as well as 10 sqm on plan inculding disposal of excavated soil upto1mt from cutting edge.
41Extra for earth work for every additional lift of 1.5 M or part thereof
42Providing and laying of dry stones soling tightly hand packed.
43Provding and laying of 1:4:8 nominal mix cement concrete.
44R.R masonary with quarry stone laid in 1:6 CM
45R.R masonary with quarry stone laid in 1:6 dry
46Providing and laying of 50 mm thick DP band over stone work in 1:2:4 nominal mix
47Brick work with ommon brunt clay F.P.S bricks of class designation 75 in foundation and plinth in 1:6 CM.
48Extra over Brick in super structure up to floor V level.
49Providing and fixing of wooden chowkat in first class kail wood.
50Providing and fixing of 35mm thick glazed shutters for doors and windows First class kail wood.
51Providing and fixing panelled or panelled andglazed shutters for doors and windows 35mm thick of Kail wood.
52Providing and fixing of panelling or penelling and glazing in panelled or panelled and glazed shutters for doors and windows ; penelling 25mm to 40mm thick of Kail wood.
53Providing and fixing of 35mm thick wire guage shutters for doors and windows.
54Reinforced cement concrete work in 1:2:4 nominal mix with 20mm N/S stone aggregate.
55Providing Reinforcement to the RCC works including bending, binding, cutting placing in position complete.
56Centering and shuttering including proping, struting etc and removal of farm work. Lintel / V beam
57Slab
58Slab edges
59Providing 50mm thick cement concrete flouring with floating coat of neat cement.
6012mm thick cement sand plaster in 1:4 mix
611:3 mix with floating coat of neat cementfor saptic tank.
62Providing and fixing 1st quality ceramic glazed tiles with minimum thickness 5mm of approved make like Kajaria, Somany etc. over 12mm thick cement mortar in 1:3 mix.
63Providing and laing / fixing ceramic glazed floor tiles 300x300mm of 1st class of Somany or Kajaria or equilent made laid on 20mm thick bed of lcement mortar in 1:4 mix.
64Providing and fixing water closet squarting pan (Indian type with 100mm sand cast iron P or S trap, 10 lit, low level PVC flusingcistern including flushing pipe and making good the walls and floors wherever required (Orrisa pattern with intergral foot type).
65Providing and fixing salem stainless steel kitched sink. Size 610x510x200mm
66Providing and fixing of PVC wasit pipe sink including PVC waist fititng complete (flexable 40 mm dia = 1 No)
67Providing and fixing of sanitary fititng
68Structual steel works welded in built up section, trusses and framed works including cutting hoisting, fixing in position and applying priming coat of approved steel primer complete.
69Providing and fixing corrogated G.S Sheets including vertical/curved surfaces with polymer coated J or L hooks (0.63 mm thick)
70Providing ridge or hip of width 60cm over all with plain GS sheets fixed with polymer coated J or L hoors (0.63 mm thick)
71Providing and fixing of coloured eves boarding
72Providing and fixing of 12 mm thick plyboard soffit along wiith supporting of frist class popular wood ballies.
73Supplying and fixing rolling shutter of approved make made of required size MS lathes interlocked together through their entire length etc complete with 80x0.90 mm MS laths with 0.90 mm thick top cover.
74Providing and applying white cement based putty of approved thickness 1mm of approved brand and manufacture over the plastered surfaces to prepare the surface smooth and even complate.
75Distempering lwith 1st quality acrylic distemper of approvedbrand and manufacture including applyingadditional lcoats whereever required to achive even shade. (Two Coats)
76Finishing walls with water proofing cement paint of required shade (external) (Snowsum)
77Painting with synthetic enamal paint ofapproved brand and manufacture of required colour to give even shade two or more coats on new work includingpriming coat of approved brand and manufacture. a) wood works
78b) on steel work
79Add. Provision for plumbing, and electrification to the quarter
80Carriage of material from source to dumping site at road by Mechanical transport a) Cement and steel for average lead of 21 (Km)
81b) Sand for average lead of 22 (Km)
82c) 20mm Aggregate for average lead of 22 (Km)
83c) 40mm Aggregate for average lead of 22 (Km)
84e) Bricks for average lead of21 (Km)
85f) Quarry stone for average lead of20 (Km)
86g) Soling stone for average lead of21(Km)
87Extra carriage of material from dumping site actual site by mannual labour. a) Cementfor average lead of 400 (mts)
88b) Steel for average lead of 400 (mts)
89c) Sand & 20mm Agg. for average lead of400 (mts)
90c) 40mm Agg. for average lead of400 (mts)
91e) Bricks for average lead of 400 (mts)
92f) Quarry stone for average lead of400 (mts)
93g) Soling stone for average lead of 400 (mts)
Disclaimer :