Repair / Replacement Of Unsv Internal Wiring, Light Fitting / Fixtures, Switches / Sockets And Allied Works In Md And Otm Of Hq Inf Bde, Gr, Arty Bde Signal Coy, Sata Bty, Inf Bde Camp, Inf Bde Signal Coy, Med Regt, Arty Bde, Gr, Fd Hosp And U
Tender Overview
Project Description
Repair / Replacement Of Unsv Internal Wiring, Light Fitting / Fixtures, Switches / Sockets And Allied Works In Md And Otm Of Hq Inf Bde, Gr, Arty Bde Signal Coy, Sata Bty, Inf Bde Camp, Inf Bde Signal Coy, Med Regt, Arty Bde, Gr, Fd Hosp And Units Area U
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc, complete all as specified and directed. |
| 2 | Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls, floors roofs etc, complete all as specified and directed. |
| 3 | Taking down old/unserviceable MCB DB SPN any capacity by disconnection of electric connection including MCBs, Isolators etc and making good to disturbed surface, complete all as specified and directed. |
| 4 | Taking down Old/Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs, MCBs, isolators etc and making good to distrubed surface, complete all as specified and directed. |
| 5 | M&L point wiring for One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm, single core, multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn through PVC conealed conduit 20/25 mm dia on wall/ceiling, including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes, cromium plate screw as suitable size for mounting of switch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly, complete all as specified and directed.Note : The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box, cutting of hylem sheet for fixing ofswitch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces. |
| 6 | All as per Ser item No 5 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 7 | All as per Ser item No 5 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 8 | All as per Ser item No 5 here-in-before but one bell/buzzer point controlled by onepush button on the independent board. |
| 9 | All as per Ser item No 5 here-in-before but one lightpoint controlled by two way switches,with wire 1.5 Sqmm size |
| 10 | All as per Ser item No 5 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 11 | M&L point wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm, single core, multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC Casing caping 20/25 mmon wall/ceiling, including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes, cromium plate screw as suitable size for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly, complete all as specified and directed.Note : Therate quoted is deemed to be included for Phenolic sheet (Hylem) and steel terminal box, cutting of hylem sheet for fixing of switch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces. |
| 12 | All as per Ser item No 11 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 13 | All as per Ser item No 11 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 14 | All as per Ser item No 11 here-in-before but one bell/buzzer point controlled by one push button on the independent board. |
| 15 | All as per Ser item No 11 here-in-before but one lightpoint controlled by two way switches with wire 1.5 Sqmm size |
| 16 | All as per Ser item No 11 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 17 | S&FSwitch Piano type two way switch 5 amp 230 v,complete all as specified and directed. |
| 18 | Supply and fix Switch Piano type, single pole, one way 5 Amp, complete all as specified and directed. |
| 19 | S&F Switch pianotype, single pole, one way 15 Amps, complete all as specified and directed. |
| 20 | S&F Socket out let 2-in-1 2/3 pin 5 Amps, complete all as specified and directed. |
| 21 | S&F Socket outlet 2-in-1, 3 pin, 5 and 15 amps, flush type, complete all as specified and directed. |
| 22 | S&F in replacement electric Bell, ding dong type AC 230 Volt single pole complete all as specified and directed |
| 23 | S&F in replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole, complete all as specified and directed. |
| 24 | S&F Ceiling rose, 3 terminal PVC/Polycarbonate, complete all as specified and directed. |
| 25 | S&Felectronic regulator step type 230 Volts single phase 120 watt,complete all as specified and directed |
| 26 | M&L for lamp holder, PVC /Polycarbonate type with back plate suitabl for batten fittings, complete all as specified and directed |
| 27 | Supply and Fix modular switch one way 6 Amp 240 volts one module, complete all as specified and directed |
| 28 | Supply and Fix modular switch two way 6 Amp 240 volts one module, complete all as specified and directed |
| 29 | Supply and Fix modular bell push switch one way 5 Amp 240 volts one module, complete all as specified and directed |
| 30 | Supply and Fix modular switch one way 16 Amp 240 volts one module, complete all as specified and directed |
| 31 | Supply and Fix socket modular one way 6 amp 240 volts two module, complete all as specified and directed |
| 32 | Supply and Fix socket modular one way 16 amp 240 volts two module, complete all as specified and directed |
| 33 | Supply & Fix TV socket modular one module, complete all as specified and directed |
| 34 | Supply & Fix Telephone socket modular one module, complete all as specified and directed |
| 35 | Supply & Fix regulator modular step type one way 220 volttwo module, complete all as specified and directed |
| 36 | Supply and fix in replacement of modular USB Charger, complete all as specified and directed |
| 37 | Supply and fix in replacement Blanking Plates for covering of MCB DB open space, complete all as specified and directed |
| 38 | Supply and fix in replacement switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type as per existing model and size, complete all as specified and directed |
| 39 | Supply and fix in replacement switch socket combination 2 in 1 3 pin 5 Amps flush type as per existing model and size, complete all as specified and directed. |
| 40 | S&F in replacement ofsheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps to 32 Amps, complete all as specified and directed |
| 41 | M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor, PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceilingetc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly, complete all as specified and directed. Note:- (i) All three wire (Phase red colour, neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) Painting over surface conduit to be done to match with walls/ceiling existing surfaces.(iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length) |
| 42 | All as per ser item No 41 here-in-before but 2 x 2.5 Sqmm and 1 x 2.5 Sqmm for Earth wire. |
| 43 | All as per ser item No 41 here-in-before but 2 x 4 Sqmm and 1 x 4.0 Sqmm for Earth wire |
| 44 | All as per ser item No 41 here-in-before but 2 x 6 Sqmm and 1 x 6.0 Sqmm for Earth wire |
| 45 | M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor FR PVC insulated and unsheathed FRLSH cable 1100 Volts grade, drawn in with and including PVC casing / caping 20/25 mm diaas per site requirement along walls/ceilingetc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly, complete all as specified and directed. Note:- (i) All three wire (Phase red colour, neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) Painting over surfaceconduit to be done to match with walls/ceiling existing surfaces.(iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length) |
| 46 | All as per ser item No 45 here-in-before but 2 x 2.5 Sqmm and 1 x 2.5 Sqmm for Earth wire |
| 47 | All as per ser item No 45 here-in-before but 2 x 4 Sqmm and 1 x 4.0 Sqmm for Earth wire |
| 48 | All as per ser item No 45 here-in-beforebut 2 x 6 Sqmm and 1 x 6.0 Sqmm for Earth wire |
| 49 | M&L fixingPVC Casing caping 20/25 mmon wall/ceiling, including replacement of old u/s PVC cashing caping for exesting old servicablepoint wiringfor existing old servicable point wiring of 1.5mm/ 2.5mm/ 4mm & 6 sqmm, Existing wiring/Submain wiring drawn through new PVC Casing caping/conduit on wall/ceiling, including replacement, complete all as specified and directed.(Note:- Therate quoted is deemed to be included for taking down of U/S PVC Casing caping/ conduitincluding cutting & fixing charges &making good to disturbed surface and matching with existing surfaces) |
| 50 | Supply and fixMCBDB SPN 4 way double door withmetal door suitable forhousing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed |
| 51 | Supply and fixMCBDB SPN 8 way double door with metal door suitable forhousing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories, complete all as specified and directed |
| 52 | Supply and fix MCBDB SPN 12 way double doorwith metal door suitabl forhousing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories, complete all as specified and directed |
| 53 | Supply and fix MCBDB TPN 4 way with metal door suitable forProvision ofincommer and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories, complete all as specified and directed. |
| 54 | Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole, complete all as specified and directed |
| 55 | Supply and fix in replacement MCCB 63 Amp 415 volts 16kA 4 pole, complete all as specified and directed |
| 56 | S&F in replacement of MCB SP 6 to 32 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 57 | S&F in replacement ofMCB SP 63 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 58 | S&F in replacement of MCB DP 40Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 59 | S&F in replacement of MCB DP63 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 60 | S&F in replacement ofisolator DP 40 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 61 | S&F in replacement ofisolator DP 63 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 62 | S&F in replacement ofisolator TPN 40 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 63 | S&F in replacement ofisolator TPN 63 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 64 | S&F in replacement ofisolator TPN 100 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed. |
| 65 | S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver, including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed |
| 66 | S&F in replacement of LED tube light fitting 18 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver, including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed |
| 67 | S&F in replacement of Lienear & compact 9 wat LED mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser including 2/3 core flexible copperwire with flexible pipe ceiling rose to light fittings, complete all as specified and directed |
| 68 | S&F in replacement of building LED security light fitting 35 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device, luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut, bolt, washer etc, complete all as specified and directed |
| 69 | S&F in replacement of Ultra slim LED panel tube light fitting 36watt 230 Volt made from extruded aluminium housing frame (recess/ pendant) 2\" x2\" Complete with all accessories internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed |
| 70 | S&F in replacementPVC ventilating airfan single phase 250 mm sweep complete with louver shutter and including making of hole suitable sizefan base after cutting of brick/stone wall /suitable size of water proof ply wood, complete all as specified and directed. |
| 71 | S&F in replacement of ventilating air fan single phase 300 mm sweepcomplete with louver shutter and including making of hole suitable sizefan base after cutting of brick/stone wall /suitable size of water proof ply wood, complete all as specified and directed. |
| 72 | Supply, Laying on replacement, connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductorcable, complete all as specified and directed. |
| 73 | Excavation in trenches in loose/soft soil not exceeding 1.5 metrewide and not exceeding 1.5 metre deep for laying of cables, poles/stays, struts etc and getting out including trimming sides and forming bottom surface, complete all as specified and directed. |
| 74 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed. |
| 75 | Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick, complete all as specified and directed. |
| 76 | Supply and Spread dry river sand for cable cushioning in trenches, complete all as specified and directed.Note : Punned down thickness shall be considered for measurement . |
| 77 | Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection, complete all as specified and directed. |
| 78 | M &L Earthing complete with galvanised steel earth plate electrode 60×60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed.Note :- (i) Earthing test must be carried out in presence of Engr-in-Charge.(ii) The earthing resultnot more than 2 Ohms or disered earth resistance value.(iii) Meggerrequired for testingwill bebe provided at site by the contractor.(iv) Contractor shall submit earth resistance testing report before submission of bill. |
| 79 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender