Modernisation Of Chitranjali Studio-Civil Mep And Acoustics
Tender Overview
Project Description
Modernisation Of Chitranjali Studio-Civil Mep And Acoustics
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Sep-2022 | Technical Corregendam | Technical Bid | 16-Sep-2022 |
| 2 | 13-Sep-2022 | Date Corregendum | Date | 23-Sep-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Part 1.Buildings - Civil works |
| 2 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead up to 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 6 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soil |
| 7 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. Ordinary or hard rock |
| 8 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 9 | Providing anti termite treatmentAlong the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration ( Excluding the cost of Chemical emulsion) |
| 10 | Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 11 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 12 | Treatment of soil underfloors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (Excluding the cost of Chemical emulsion) |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 14 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mmnominal size). |
| 15 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 16 | Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Columns, Pillars, Piers, Abutments, Posts and Struts |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Stairs, (excluding landings) except spiral-staircases |
| 23 | Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured). |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 25 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 |
| 26 | Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints. |
| 27 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately) - All works up to plinth level |
| 28 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately) - Above plinth level up to floor five level |
| 29 | Add/less (\"+\" or \"-\")for using extra or less cement in the items of design mix over and above the specified cement content therein. |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5in plinth Cement Mortar 1:6 (1 cement : 6 coarse sand). - 230mm thick |
| 31 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand) - 230mm thick |
| 32 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 33 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 34 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: |
| 35 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge. a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 36 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 37 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 38 | Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 39 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant included ). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm , & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm up to 5.00 sqm). |
| 40 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, Float glass panes of 5.50 mm thickness all complete as per approved drawing &direction of Engineer-in-Charge. |
| 41 | Providing and fixing factory made uPVC white colour sliding glazed window up to 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process ofrequired length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction ofEngineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) -Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window up to 1.75 sqm) |
| 42 | Providing and fixing factory made uPVC white colour sliding glazed window up to 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension (Area of window up to 1.75 sqm). No Item heading |
| 43 | Providing and fixing of Wooden Finish UPVC (Unplascticised Poly Vinyl Chloride) three track Sliding Window using 60mm x 37mm outer frame with door Sash of 39 x 75mm frame and all sections shall reinforced with galvanised steel. The Glazed shutters are fixed with 6mm clear float glass fixedwith EPDM gasket and co extruded beadings with Espag locking system. The door frame is fixed to the walls using fasteners and to be sealed as external and internal surfaces using weather resistant Silicon sealant of approved make complete as per drawing. |
| 44 | Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sashadaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame &sash shall be mitred cut and fusion welded at all corners, including drillingof holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm up to 5.00 sqm) |
| 45 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 46 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 47 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5m long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 48 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and up to 16.80 sqm in the area |
| 49 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped- Hot finished welded type tubes |
| 50 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 51 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer - M.S. tube |
| 52 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 53 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 4.0 mm thick glass panes |
| 54 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge. |
| 55 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete - 40 mm thick with 20 mm nominal size stone aggregate |
| 56 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer\"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 57 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. - White Sand Stone. |
| 58 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades any size as approved by Engineering-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 59 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades,laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 60 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete - Tile Size : - 600mm X 600MM. |
| 61 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 62 | Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete. |
| 63 | Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete. |
| 64 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of raw plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square SUB HEAD : 12- ROOFING 742 edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I |
| 65 | Providing and Fixing 15 mm densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spin tone /cosmos /Hexa or equivalent of size 595x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main \"T\" runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross \"T\" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main \"T\" of size 24 x 28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main\"T\" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of raw plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (Spin tone / Cosmos/hexa) in the grid, including cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever require. Main \"T\" runners to be suspended from ceiling using G.I slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size of 85x30x0.8 mm, spaced at 1200mm centre to centre along main \"T\" bottom exposed with 24 mm of all T- sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed byengineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. value of 0.50 (Minimum), light reflection > 85% non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity < 0.043 w/m 0 KC. |
| 66 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 67 | Ceiling Plastering with CM 1:3, 6mm thick |
| 68 | Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :Flush/ Ruled pointing |
| 69 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 70 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work |
| 71 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
| 72 | Providing and applying plaster of Paris putty of 2 mm thickness over plasteredsurface to prepare the surface even and smooth complete. |
| 73 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coat for new work - - For Ceiling & Internal walls |
| 74 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. - External walls |
| 75 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 76 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead: With cement mortar 1:4 ( 1 cement : fine sand) |
| 77 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge - With cement mortar 1:4 (1cement: 4 coarse sand) |
| 78 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window |
| 79 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 80 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 81 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done |
| 82 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge |
| 83 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 84 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. - In Cement mortar |
| 85 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : |
| 86 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - Of area 3 sq. metres and below |
| 87 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - Of area beyond 3 sq. metres |
| 88 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 89 | Dismantling wooden trellis work excluding frames but including stacking the serviceable material within 50 metres lead. |
| 90 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe |
| 91 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 92 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 93 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 94 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge. Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade. |
| 95 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 96 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 97 | Providing and fixing APP ( Atactic Polypropylene Polymer) modified prefabricated five layer 2 mm thick water proofing remembrance, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 250C, 0.87 - 0.89 kg/ litre and viscosity 70- 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 230C as 350/ 300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80 N. Softening point of membrane not less than 1500C. Cold flexibility shall be up to - 20C when tested in accordance with ASTM, D- 5147 The laying of membrane shall be got done through the authorized applicator of the manufacture of membrane. |
| 98 | Filling with contractor\"s own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 99 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc. complete |
| 100 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc. complete |
| 101 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete |
| 102 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 103 | Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110 mm dia 4 Kg/cm2 |
| 104 | Supplying Fabricating and Fixing in position of single leafaluminium anodized natural colour matt finish door with frame using frame section 101.64x44.45x3.18mm for vertical style and horizontal piece, shutters section for top, middle and vertical style of size 50x44.45x2.50mm board section of size 100x44.45x2.50mm half glazed 5.50mm thick and half PLB board 12mm thickglazed door using rectangular aluminium box section with necessary accessories such as rubber beading, aluminium chips, best double action door closer with handles, locks and glass etc.,including all materials, labour and power consumption charges required for fabrication if necessary chipping, dismantling making necessary holes in RCC columns, beams or masonry wherever necessary with power drill to the extent required and made good to the original condition after fixing etc., complete. The aluminium surfaceshould beanodized with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 of anodic film thickness of not less than 15 microns for all sections. All the materials should be got approved by theEngineer - in - Charge before fixing in position and as directed by the departmental officers. |
| 105 | Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1500mm(W) x 2100mm(H) Wall Opening Width (W): 1500mm Wall Opening Height(H): 2100mm Profile Size – Single Rebate: 100*58 Door Thickness: 46mm Infill Material: 25mm with density 1000GSM Frame Sheet Tickness:1.6mm Shutter Sheet Thickness: 1.2mm Finish- PU Paint/ Laminate Door Type: Fire Door with Acoustic Treatment Number of Door Leaf: Fire rating - 2Hours : Single Door Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal. |
| 106 | Fabricating, Supplying and Fixing in position MS Staircase railings with Top hand rail ofTeak wood member of 100 mm diaof First class teak wood fixedto beas railing connected to the verticals made of combination of 50x50mm 14 SWGcorner posts & 16x16mm 14 SWG intermediate posts @ ~ 355mmthrough 25mm dia connectors. There shall 2 horizontal members of 20x20mm 14SWG connected to the wall at the ends & to the verticals as shown in the detailed drawing. There shall be additional intermediate posts @ 118mm c/c between the mid-rails. Balusters should be fixed to the concrete slabs throughconnector plates & cap plates as per the detail drawings. All MS will be Enamel painted finish with base primer coat and ready mixed wax polish for Teak woodas perProject Consultants / Site in charge instructions. |
| 107 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement, teak wood jamb with ready mixed wax coat(75mmx225mm) and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in charge |
| 108 | Dismantling the existing DG 2nos and Electrical Panels and other Mechanical & Electrical items etc.,work manually/ by mechanical means including stacking of dismantling materialas per direction of Engineer-in-charge. ( Existing Mechanical & Electrical items including DGs & Panels etc., ) |
| 109 | Expand Joint area cleaning, PU sealant applying, Two coat Boscolastic or equivalent chemical coating |
| 110 | Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) |
| 111 | Dismantling the existing truss roof and roofing sheet work manually/ by mechanical means including stacking of dismantling materialas per direction of Engineer-in-charge for buildings having cumulativePlinth area as specified in the quantity.Bidder to quote amount based on theirown assessment during site visit prior to submission of Bid. |
| 112 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 113 | Supplying and laying Mangalore tile type decorative roofing tileover the RCC sloped roof jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 114 | All cracks area v cutting and cleaning, one coat Hydroment476 or equivalent chemical primer coating,Elastobar chemical with cementation chemical packing |
| 115 | Providing and fixing partition up to ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture\"s specification and direction of engineer in charge all complete.66 mm overall thickness partition using 8 mm thick double skin multipurpose cement bonded wood particle board manufactured as per IS: 14276 with suitable cement bonded board screws |
| 116 | GI sheet area One coat Oil Bitumen primer Applying@ 0.40 litre/sqm,2mm Bitumen felt butane torch applying, all Bitumen joint area heatmeltingang Hot bitumen sealing, final one coat heat resistance silver paint applying |
| 117 | Dismantling / removing the existing roofing sheet with wooden truss etc.,work manually/ by mechanical means including stacking of dismantling materialas per direction of Engineer-in-charge andthe new roofing truss as per site conditions for buildings having cumulativePlinth area as specified in the quantity to be designed by the contractor as per the applicable codes and standard. Bidder to quote amount based on theirown assessment during site visit prior to submission of Bid. |
| 118 | Dismantling and removing air conditioning indoor and outdoor unit along with wires, cables etc. complete and then keeping them in a secured place as per the instruction of the engineer in charge. |
| 119 | Dismantling and removing all kinds of chairs fixed to flooring all complete and keeping them in a secured place as per the instruction of the engineer in charge. |
| 120 | Dismantling and removing acoustic wall panels and acoustic flooring all complete and keeping them in a secured place as per the instruction of the engineer in charge. |
| 121 | Dismantling the existing stage with the height not more than 1 mtr from FFL ( PCC, Brick work & Plastering ) and carting away the compacted earth inside stage and disposing the rubbish and earthas directed by the Engineer in charge. |
| 122 | Supply and fixing of Green fabric of thickness not less than 250 GSM for Chroma screen 0% gathering with eyelets. Size: LMtr x HMtr. ( Makes: Mayur / Omphile / Raymonds / Nexgen) . |
| 123 | RCC walls and Floor area Holes cleaning, Bostic Patch fix/Raft bondmicro concrete Chemical and baby chips packing (hole size up to 100mm dia & up to 200 mmdepth ) Bidder to quote amount based on theirown assessment during site visit prior to submission of Bid. |
| 124 | Brick wall Holes area cleaning ,one coatboscochem 475 chemical /Raft bondprimer coating, Micro concrete chemical packing (hole size up to 100mm dia & up to 100 mmdepth ) Bidder to quote amount based on theirown assessment during site visit prior to submission of Bid. |
| 125 | Treatment for reinforcement exposed in and around the existing buildings, First coat Hydroment476 chemical primer coating 4 Hours curring,After 4 hours Two coat Hydroment476 with cementation .Bidder to quote amount based on theirown assessment during site visit prior to submission of Bid. |
| 126 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 127 | Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick: - 5.5mm float glass |
| 128 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 129 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineering- charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm |
| 130 | Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and up to floor five level. Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 131 | Part 2. Plumbing works |
| 132 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth. including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m: Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 133 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \"S\" or \"P\" trap including dismantling of old WC seat and \"S\" or \"P\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm |
| 134 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc. complete. |
| 135 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. Size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge. |
| 136 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm |
| 137 | Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm |
| 138 | Providing and fixing C.P. brass toilet paper holder: |
| 139 | Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet - Sand cast iron S & S as per IS : 3989 |
| 140 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 141 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms |
| 142 | Providing and fixing white vitreous china flatback or wall corner type lipped front urinal basin of 430 x 260 x 350mm and 340x410x 265mm sizes respectively with automatic flushing cistern with standard flush pipe and CP brass spreaders with brass unions and GI clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre PVC automatic flushing cistern. |
| 143 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm nominal outer dia pipes |
| 144 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm nominal outer dia pipes |
| 145 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm nominal outer dia pipes |
| 146 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore |
| 147 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore |
| 148 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore |
| 149 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 20 mm nominal bore |
| 150 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 25 mm nominal bore |
| 151 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter |
| 152 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 153 | Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type - With Sewer bricks conforming to IS : 4885 |
| 154 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg): |
| 155 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design |
| 156 | Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 157 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 |
| 158 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 |
| 159 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 |
| 160 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 161 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single15 mm C.P. brass pillar tap |
| 162 | Supply and fix electrical water heater 25 liter capacity with all necessary accessories complete with all water proofing mounting and fastening material heat insulation, safety and return valves complete with all accessories etc complete as per drawing and as directed by the Engineer-in-charge. |
| 163 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern and all necessary accessories, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm |
| 164 | Part 3.Internal firefighting works |
| 165 | Supply, erection, testing and commissioning of heavy C class MS pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete- 150mm dia pipe |
| 166 | Supply, erection, testing and commissioning of heavy C class MS pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete- 50mm dia drain line |
| 167 | Supply, erect, jointing, testing and commissioning MS Heavy C class in trenches (1 Mtrs below ground level).Rate quoted shall include for necessary specials like long radius bends, tees including cutting, welding, flanged joints with necessary washers, nuts, bolts etc.Rate quoted shall also include for providing concrete anchor blocks at all change in direction of pipeline and also near each joints and giving anticorrosive treatment as per specification. Including cost for excavation & refilling. - 150mm dia pipe |
| 168 | Providing, Laying, Testing and commissioning of 250 mm dia RCC pipes of NP2 class hume pipes |
| 169 | Supply, fixing, testing and commissioning of lever operated slim seal butterfly valves as per detailed specifications complete with Tamper switch, companion flange, nuts, gaskets, bolts etc. complete as required - 150mm dia pipe |
| 170 | Supply, fixing, testing and commissioning of Single Hydrant valve (SS) |
| 171 | Supply, fixing, testing and commissioning of RRL hose filled with SS couplings of 15 mtr long |
| 172 | Supply, fixing, testing and commissioning of SS branch pipe |
| 173 | Supply, fixing, testing and commissioning of Hose reel Drum with Hose Reel of 30 mtr and spray nozzle. |
| 174 | Supply, fixing, testing and commissioning of MS Hose Tray MS Hose tray is type of Hose rack. It is fixed inside the fire cabinet/fire duct door. |
| 175 | Supply and fix Internal glass fronted duct Door (GI metal)with hinged and lock, made out ofAluminium powder coated(po red) sheet of suitable size as per specifications and drawings |
| 176 | Supply & fixing ofBrass air release valve 25mm at the top of each floor of the riser with drain connection and the rates shall include all the accessories. |
| 177 | Supply, erection, testing and commissioning of C class GI pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete - 150mm dia |
| 178 | Supply, erection, testing and commissioning of C class GI pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 50mm dia |
| 179 | Supply, erection, testing and commissioning of C class GI pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 40mm dia |
| 180 | Supply, erection, testing and commissioning of C class GI pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete - 32mm dia |
| 181 | Supply, erection, testing and commissioning of C class GI pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 25mm dia |
| 182 | Supply, fixing, testing and commissioning of lever operated slim seal butterfly valves as per detailed specifications complete with Tamper switch, companion flange, nuts, gaskets, bolts etc complete as required - 100m dia |
| 183 | Supplying, Installing, testing and commissioning of Test & Drain valve of size 50mm. |
| 184 | Supplying, erecting, testing and commissioning of Standard Response Pendent sprinkler 1/2\" (15mm)BSPT end connection, 68 deg , Celsius, chrome finish. |
| 185 | Supplying, Installing, testing and commissioning of flow switch 150mm diainstalled on the sprinkler main distribution line connected to the main sprinkler annunciation panel located in the ground floor. |
| 186 | Supplying, Installing, testing and commissioning ofSS ball valve of size 25mm dia for flushing purpose. |
| 187 | Supply, Installation, Testing & Commissioning of 4 Kg Capacity of ABC type fire extinguisher fixing on the floor with suitable fixture. |
| 188 | Supply, Installation, Testing & Commissioning of 4.5 Kg capacity of CO2type fire extinguisher fixing on the floor with suitable fixture. |
| 189 | Supply, erection, testing and commissioning of C class GI pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 65mm dia |
| 190 | Part 4.Acoustic works |
| 191 | Drishya building -Supply and installation of False ceilings with Compressed polyfibre panel: Polyfibre panels, core-pigmented, high-density, rigid panels of size 1200x2400x9mm, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2 installed by usingStrut ceiling framework. TheStrut ceiling framework system shall includeStrut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspendStrut MC45 Main channels, fully knurled,sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers withStrut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm.Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mmand equal flanges 9.5mm is fastened to theStrut MC45 perpendicularly at 600mm centers.panels of size 1200x2400x9mm is installed on theStrut CC25 with suitable fasteners in a staggered manner. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependent, Green (VoC, RC %) – Nil,30. Colour to be choose by client/architect/consultant. Approved Makes- Anutone/Topakustik /Tranquil/Equivalent. |
| 192 | Drishya building - Supply and installation of Compressed polyfibre panel:, Core-pigmented, high-density, Polyfibre panels rigid panels of size 1200x2400x9mm thk, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2. Prior to installation, ensure wall or surface behind are flat, dry and free from dust or other contaminants and leveled. Panels are then adhered to wall or surface behind with stick S7 adhesive. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependent, Green (VoC, RC %) – Nil,30. Colour to be choose by client/architect/consultant. Approved Makes- Anutone/Topakustik /Tranquil/Equivalent |
| 193 | Drishya building -Supply and installation of Vinyl flooring using 2mm thk Industrial grade Vinyl flooring with Anti -skid ,abrasion resistance , fire proof with hardness. The costing includes150mm skirting with all accessories. Vinyl floor of approved make and shade as per approved sample by Architect & Consultant. Approved Makes- Armstrong, Gerflor , LG/Equivalent |
| 194 | DI BUILDING-FALSE CEILING - Supply and Installation ofAcoustical Ebony square edge, Glassfibre core fully encapsulated ceiling tile of size 595x1195x15mm having density 100-120Kgs/m3, weight 1.5-1.8kg/m2 which is suspended by using 0.3mm thick and 15mm widepre coated metal T15 grid system.The T15 Grid system of 600x600mm module shall include wall angle (WA15W30) with unequal flanges of size 14&20mm wide, length 3000mm, 0.43mm thick fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15 (MT15W36) havingflange width 15mm, height 32mm and length 3600mm from the soffit with help of soffit cleat and wire rod with leveling spring clip at 1200mm c/c. Cross T15 (CT15W12) having flange width 15mm, height32mm and length 1200mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the Main T15. Finally Cross T15 (CT15W06) having flange width 15mm, height 32mm and length 600mm are then interlocked into the pre cut slots in the 1200mm Cross T15 at 1200mm centers andin direction parallel to the Main T15.Acoustical Ebony Square edge of size 595x51195x15mm thick shall be placed into the grid size of 600x600mm.Ensure arrow marks behind Acoustical panels are oriented in one direction to achieve uniform shade.Appoved Makes- Anutone/Gyproc/Armstrong/Equivalent |
| 195 | DI BUILDING-FALSE CEILING - Supply and installation ofPeripheral False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by usingStrut ceiling framework. The Strut ceiling framework system shall includeStrut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspendStrut MC45 Main channels, fully knurled,sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers withStrut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm.Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mmand equal flanges 9.5mm is fastened to theStrut MC45 perpendicularly at 600mm centers.tufbloc HDFR, 1200x2400x10mm is installed on theStrut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Approved Makes- Anutone/Gyproc/Armstrong/Equivalent. |
| 196 | DI BUILDING-SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Compressed polyfibre panel:, Core-pigmented, high-density, Polyfibre panels rigid panels of size 1200x2400x9mm thk, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2. Prior to installation, ensure wall or surface behind are flat, dry and free from dust or other contaminants and leveled. Panels are then adhered to wall or surface behind with stick S7 adhesive. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependent, Green (VoC, RC %) – Nil,30. Colour to be choose by client/architect/consultant. Approved Makes- Anutone/Topakustik /Tranquil/Equivalent |
| 197 | Supply and installation of black screen masking fabric of thickness not less than 250 GSM on the metal screen frame structure provided. Bidderto make their own assessment based on the relevant drawings to meet the requirement. |
| 198 | DI BUILDING- CARPET FLOORING - Supply and installation of carpet 4mm thick Tile over the specified area with following specification. The floor which receives the carpet to be thoroughly cleaned as per manufacturer\"s specification. The carpet is to be laid over a bed of manufacturer\"s approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover/on commissioning. The measurements of carpet will be the actual laid area. Providing & laying carpet tile with following specification:Style: Tile, Construction : Tufted Textured Loop, Fiber Product: 100% Solution Dye PP, Gauge: 39.4/10cm. (1/12),Finish Pile Thickness: 7.49mm +/- 0.5, Production yarn weight: 20 oz, Dye Method: 100% solution Dyed, Primary backing: Action Back, Tuft Bind: As per ASTM Standards, Delamination Strength: As per ASTM Standards, Static Control: As per ASTM Standards, Soil retardant: Protek ,Anti-Microbial:Alphasan Built in Protection, Moisture Control: Yes, Electrostatic propensity: less than 3.5KV-Permanent Cond, Flammability( Radiant Panel ASTM-E-662): >_0.45 ( Class I) |
| 199 | DI BUILDING- ACOUSTIC FIRE RATED DOOR - Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1500mm(W) x 2100mm(H)Wall Opening Width (W): 1500mmWall Opening Height(H): 2100mmProfile Size – Single Rebate: 100*58Door Thickness: 46mmInfill Material: 25mm with density 1000GSMFrame Sheet Tickness:1.6mmShutter Sheet Thickness: 1.2mmFire rating - 2 HoursFinish- PU Paint/ LaminateDoor Type: Fire Door with Acoustic TreatmentNumber of Door Leaf: SingleFire rated - 2 HoursDoor Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal. |
| 200 | DI BUILDING-THEATRE CHAIRS - Supply & Installation of Back push recliner chair of center to center 588mm,1100mm height, Plywood (hardwood) with induction heating and high pressure pressed. ABS moulded housing for seat & back cushions, armrest made of PP/PPCP/ABS or semi rigid PU foam. Polyurethane injection moulded flexible foam seat and back density 50 – 55 kg/m3, Fabric to be 100% polyester synthetic fabric with 4 mm polyurethane foam lamination. Fire retardant standard ISO3795, FMVVSS302, Water repellent -Standard -AATCC193. Torsion spring/spring steel IS:4454 1981 Grade III. HRCA/CRCA Sheet metal IS:1079 1994, Electrostatic epoxy powder coating thickness:70 - 80 microns. Seat numbering at side of the chair with LED lights on sides along with aisles. The chairs should be installed to the flooring with the anchor fasteners 12mmx100mm pin type. Fabric colour to customer choice. The chair frame shall be up of metal or wood as directed engineer in charge |
| 201 | OFFICE BUILDING- DUBBING STUDIO -FALSE CEILING - Supply and Installation ofAcoustical square edge, Grassfire core fully encapsulated ceiling tile of size 595x1195x15mm having density 100-120Kgs/m3, weight 1.5-1.8kg/m2 which is suspended by using 0.3mm thick and 15mm widepre coated metal T15 grid system. The T15 Grid system of 600x600mm module shall include wall angle (WA15W30) with unequal flanges of size 14&20mm wide, length 3000mm, 0.43mm thick fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15 (MT15W36) havingflange width 15mm, height 32mm and length 3600mm from the soffit with help of soffit cleat and wire rod with leveling spring clip at 1200mm c/c. Cross T15 (CT15W12) having flange width 15mm, height32mm and length 1200mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the Main T15. Finally Cross T15 (CT15W06) having flange width 15mm, height 32mm and length 600mm are then interlocked into the pre cut slots in the 1200mm Cross T15 at 1200mm centers andin direction parallel to the Main T15.Acoustical Ebony Square edge of size 595x51195x15mm thick shall be placed into the grid size of 600x600mm.Ensure arrow marks behind Acoustical panels are oriented in one direction to achieve uniform shade. Appoved Makes- Anutone/Gyproc/Armstrong/Equivalent |
| 202 | OFFICE BUILDING- DUBBING STUDIO -FALSE CEILING -Supply and installation ofPeripheral False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by usingStrut ceiling framework. TheStrut ceiling framework system shall includeStrut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspendStrut MC45 Main channels, fully knurled,sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers withStrut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm.Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mmand equal flanges 9.5mm is fastened to theStrut MC45 perpendicularly at 600mm centers.tufbloc HDFR, 1200x2400x10mm is installed on theStrut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Approved Makes- Antonne/Gyproc/Amstrong/Equivalent. |
| 203 | OFFICE BUILDING- DUBBING STUDIO - SIDE WALLS ACOUSTIC PANELLING - Supply and installation ofIsolation & Absorption treatment: Using Calcium Silicate/Cement Core board & Stretch NRC wall fabric system with Magnesite bonded pinewood strand boards: The CC25 cross channel Strut framework fastened to wall with 10mm thick 100x100mm Nitrile/Neoprene rubber pads backed with 12mm plywood/hard wood piece of 100x100mm. The channels should never have any direct contact on the dry wall. 12mm Calcium Silicate board of two layers sandwiched with sound membrane sheet of3mm is fixed on the frame work .Strand square edge magnesite bonded pinewood fiber panels of size 600x1200x20mm having density 400kg/m3, weight 4kg is fastened on the sandwiched board assembly andbacked with micro wadding polywool of 1000gsm and 25mm thickness adhered with 12mm rigid vinyl stretch tracks half wrap/full wrap 15mm (FS15) and Midseam 15mm (FS15), with requisite accessories & tools. FS15 tracks to be installed on wooden base, after applying suitable adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of stretch track. Fabric of width 1700mm is then aligned to the stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools.Fabric colour & design will be specified by architect/consultant. |
| 204 | OFFICE BUILDING- DUBBING STUDIO - Supply and Installation of Acoustic polyether foam base traps of minimum size of 610x280x280 for corners and 600x600x50mm pyradid base base traps for the ceilings & wall surfaces( Minimum 8 nos of corner and 20 nos for walls & ceiling) - (Bass Trap) |
| 205 | OFFICE BUILDING- DUBBING STUDIO - CARPET FLOORING - Supply and installation of carpet 4mm thick Tile over the specified area with following specification. The floor which receives the carpet to be thoroughly cleaned as per manufacturer\"s specification. The carpet is to be laid over a bed of manufacturer\"s approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover/on commissioning. The measurements of carpet will be the actual laid area. Providing & laying carpet tile with following specification:Style: Tile, Construction : Tufted Textured Loop, Fiber Product: 100% Solution Dye PP, Gauge: 39.4/10cm. (1/12),Finish Pile Thickness: 7.49mm +/- 0.5, Production yarn weight: 20 oz, Dye Method: 100% solution Dyed, Primary backing: Action Back, Tuft Bind: As per ASTM Standards, Delamination Strength: As per ASTM Standards, Static Control: As per ASTM Standards, Soil retardant: Protek ,Anti-Microbial:Alphasan Built in Protection, Moisture Control: yes, Electrostatic propensity: less than 3.5KV-Permanent Cond, Flammability( Radiant Panel ASTM-E-662): >_0.45 ( Class I) |
| 206 | OFFICE BUILDING- DUBBING STUDIO - DOUBLE GLAZED GLASS PARTITION - Supply and installation of Double glazed units with outer glass 6 mm thick clear toughened glass with 12mm air gap and inner 6mm thick clear toughened glass of Saint Gobin make, made as per standard specifications including providing and fixing 200 micron thick Blast Mitigation Film (including Shatter Resistance capability) |
| 207 | OFFICE BUILDING- ACOUSTIC FIRE RATED DOOR - Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1200mm(W) x 2400mm(H)Wall Opening Width (W): 1200mmWall Opening Height(H): 2400mmProfile Size – Single Rebate: 100*58Door Thickness: 46mmInfill Material: 25mm with density 1000GSMFrame Sheet Tickness:1.6mmShutter Sheet Thickness: 1.2mmFinish- PU Paint/ LaminateDoor Type: Fire Door with Acoustic TreatmentNumber of Door Leaf: SingleFire rating - 2 HoursDoor Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM)Door (Drop) Bottom Seal. |
| 208 | OFFICE BUILDING-FALSE CEILING - Supply and installation of False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by usingStrut ceiling framework. TheStrut ceiling framework system shall includeStrut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspendStrut MC45 Main channels, fully knurled,sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers withStrut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm.Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mmand equal flanges 9.5mm is fastened to theStrut MC45 perpendicularly at 600mm centers.tufbloc HDFR, 1200x2400x10mm is installed on theStrut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Approved Makes- Anutone/Gyproc/Armstrong/Equivalent. |
| 209 | OFFICE BUILDING-SIDE WALLS ACOUSTIC PANELLING - Supply and installation ofIsolation & Absorption treatment: Using Calcium Silicate/Cement Core board & Stretch NRC wall fabric system with Magnesite bonded pinewood strand boards: The CC25 cross channel Strut framework fastened to wall with 10mm thick 100x100mm Nitrile/Neoprene rubber pads backed with 12mm plywood/hard wood piece of 100x100mm. The channels should never have any direct contact on the dry wall. 12mm Calcium Silicate board of two layers sandwiched with sound memberane sheet of3mm is fixed on the frame work .Strand square edge magnesite bonded pinewood fiber panels of size 600x1200x20mm having density 400kg/m3, weight 4kg is fastened on the sandwiched board assembly andbacked with micro wadding polywool of 1000gsm and 25mm thickness adhered with 12mm rigid vinyl stretch tracks half wrap/full wrap 15mm (FS15) and Midseam 15mm (FS15), with requisite accessories & tools. FS15 tracks to be installed on wooden base, after applying suitable adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of stretch track.Fabric of width 1700mm is then aligned to the stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools.Fabric colour & design will be specified by architect/consultant. |
| 210 | OFFICE BUILDING-Supply and Installation ofAcoustic Soak Cord, square edge, fabric wrapped pinewood fiber core panel of size 600x1200x25 / 600X600X25 mm,with ribbed finish, volume density 400Kgs/m3, weight 10kg/m2 installed by using Strut Z bar. Strut Z bars having40mm height, thickness 1mm is first fixed behind the panels by using suitable fasteners. Another length of Strut Z bars to be fastened perpendicular to wall. Soak cord, square edge panels are then slided on to Strut Z bar to fix on the wall surface. Technical Parameter Fire (Class) – 1 & P Acoustics – NRC 0.9 Thermal conductivity (W/mk)– 0.08, Climate (°C, RH) – 50, 90, Light reflectance (%) – colour dependant,Green (VOC, RC %) – Low,30.Appoved Makes- Anutone/Gyproc/Armstrong/Equivalent |
| 211 | OFFICE BUILDING-Supply and Installation of Acoustic polyether foam base traps of minimum size of 610x280x280 for corners and 600x600x50mm pyradid base base traps for the ceilings & wall surfaces( Minimum 8 nos of corner and 20 nos for walls & ceiling) - (Bass Trap) |
| 212 | OFFICE BUILDING- DUBBING -CONSOLE ROOM - WOODEN FLOORING - Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200 mm X 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm the top abrasive layer over a decorative layer followed by a High-density fiberboard (HDF) having density > 850 kg/m3 substrate core over a resin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer \"T\" profile etc. Cost of Laminate Floor Accessories only (Skirting ,End edge, T- moulding,Reducer) shall have to be added separately, wherever required. (Type and design to be confirmed by Consultant/ Architect/ Client) |
| 213 | OFFICE BUILDING-VINYL FLOORING - Supply and installation of Vinyl flooring using 2mm thk Industrial grade Vinyl flooring with Anti -skid ,abrasion resistance , fire proof with hardness. The costing includes150mm skirting with all accessories. Vinyl floor of approved make and shade as per approved sample by Architect & Consultant. Approved Makes- Armstrong, Gerflor , LG/Equivalent |
| 214 | OFFICE BUILDING-MULTI MATERIAL FLOORING - Supply and installation of multi flooring materials such us tile, carpet, wooden, stone, concrete, wooden plank, granite, marble, water tub, sand floor etc as per drawing and design specified for the multipurpose of foley studio. |
| 215 | OFFICE BUILDING- ACOUSTIC FIRE RATED DOOR - Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 2200mm(W) x 2400mm(H)Wall Opening Width (W): 2200mmWall Opening Height(H): 2400mmProfile Size – Single Rebate: 100*58Door Thickness: 46mmInfill Material: 25mm with density 1000GSMFrame Sheet Tickness:1.6mmShutter Sheet Thickness: 1.2mmFinish- PU Paint/ LaminateDoor Type: Fire Door with Acoustic TreatmentNumber of Door Leaf: DoubleFire rating - 2 HoursDoor Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM)Door (Drop) Bottom Seal. |
| 216 | OFFICE BUILDING- FOLEY STUDIO - FLOATING PROPERTIES FOR FOLEY ROOM - Supply and installation of loose furniture\"s like table, chair, storage cabinet, cupboards and other loose properties( Bidder to make own assessment and contractor should prepare furniture layout plan based on the client requirement and submit the same to the Engineer in charge for approval ) |
| 217 | OFFICE BUILDING- FOLEY -CONSOLE ROOM - Supply and Installation of Acoustic polyether foam base traps of minimum size of 610x280x280 for corners and 600x600x50mm pyramid basetraps for the ceilings & wall surfaces( Minimum 8 nos of corner and 20 nos for walls & ceiling) |
| 218 | OFFICE BUILDING- -WOODEN FLOORING -Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200 mm X 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 850 kg/m3 substrate core over a resin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer \"T\" profile etc. Cost of Laminate Floor Accessories only (Skirting ,End edge, T- moulding,Reducer) shall have to be added separately, wherever required. (Type and design to be confirmed by Consultant/ Architect/ Client) |
| 219 | - Supply and affix the M10 Threaded rod from the ceiling using suitable hardware\"s in a grid of 1200mmX600mm as per shared schematics for the Isolation Ceiling.-Prepare and affix 26mm Ceiling channel perpendicular to the Ceiling Slab (600x600mmc.c.) as per the shared schematics. All proprietary accessories and hardware to be used for the 26mm furring Ceiling channel sections as per the guidelines of the OEM.-Care to be taken that the supports donot make any physical contact with the Services in the ceiling.-25mm 96 Density Rockwool Wool Insulation to be filled in the framing voids. |
| 220 | The following cladding to be executed over the furring channel:-1x12.5mm Gyproc Glasroc BoardAll joints to be staggered and duly sealed with silicone and jointing compound as per standard practices |
| 221 | STANDARD SERVICES DETAILS: All service openings to be sealed in line with the shared Standard ServicesDetails |
| 222 | -Prepare and affix an assembly of 45mm Intermediate channel to the threaded rod suspended from the ceiling-Affix 26mm furring channel perpendicular to the intermediate channel as per the shared schematics.-Care to be taken that the supports donot make any physical contact with the Services in the ceiling.-50mm 64 Density Rockwool Wool Insulation to be filled in the framing voids. |
| 223 | The following cladding to be executed over the furring channel:-1x12.5mm Gyproc Habito Board-1x12mm Gyproc Gypsum BoardAll joints to be staggered and duly sealed with silicone and jointing compound as per standard practices |
| 224 | STANDARD SERVICES DETAILS: All service openings to be sealed in line with the shared Standard ServicesDetails |
| 225 | Providing & fixing Acoustically designed doors with a BTC 100mm x 70mm\" Frame. Door Leaf to be assembledas per the shared schematics:-30mm FR door blank (Not Pine) (FR as per Fire Consultant)-25x25mm Framing with 25mm 80Density AbFoam in the framing Voids, (Class-O FR)-8mm Fibber Cement Board bonded to 3mm GI Sheet as shown in the schematics-18mm E0 MDF bonded with 5mm 10kg/m2 Mass Loaded Vinyl as per the shared door schematics.-All door hardware and finishing as per Architect\"s Details.-At least 4 hinges to be used of 5mm thk Magnum ( 6\" x 3.25\" ball bearing type).-The door closer should be heavy duty 150 kg (external type).-The handle should be solid and be a high gauge 12 \" D type. (minimum 30-35mm dia)-Perimeter Raven RP 85 Magnetic Seals and Raven RP 120 Corner Door Seals as shown in the schematicsalong 3 sides of the door.- Raven RP 126Si Drop down seal to be executed in the floor trim as per the shared details |
| 226 | Providing & fixing Acoustically designed doors with a BTC 100mm x 70mm\" Frame. Door Leaf to be assembled as per the shared schematics:-30mm FR door blank (Not Pine) (FR as per Fire Consultant)-25x25mm Framing with 25mm 80Density AbFoam in the framing Voids, (Class-O FR)-8mm Fibber Cement Board bonded to 3mm GI Sheet as shown in the schematics-18mm E0 MDF bonded with 5mm 10kg/m2 Mass Loaded Vinyl as per the shared door schematics.-All door hardware and finishing as per Architect\"s Details.-At least 4 hinges to be used of 5mm thk Magnum ( 6\" x 3.25\" ball bearing type).-The door closer should be heavy duty 150 kg (external type).-The handle should be solid and be a high gauge 12 \" D type. (minimum 30-35mm dia)-Perimeter Raven RP 85 Magnetic Seals and Raven RP 120 Corner Door Seals as shown in the schematics along 3 sides of the door.-Raven RP 65 Morticed seal to be executed between two door leafs as per the shared details-Raven RP 126Si Drop down seal to be executed in the floor trim as per the shared details |
| 227 | Prepare and Fix 75X50mm 1.6mm Gauge GI/Aluminium Frame as shown in the drawing affixed to the floor and Isolation ceiling using suitable hardware\"s-Suitable openings to be made on the wall for housing the speakers.-Speaker boxing to be built with sandwiched layer of 2x18mm Birch Plywood-Speaker boxing to be lined with 25mm 80 density AB foam All remaining voids inside the Speaker wall to be filled with 50mm 64 Density Rockwool Insulation |
| 228 | The following cladding to be executed o the front of the speaker wall:-1x12mm Birch Plywood-1x12mm Gypsum Board-1x50mm AB FoamAll joints to be staggered and duly sealed with silicone and jointing compound as per standard |
| 229 | PERFORATED WALL:-Supply and Fix a 92mm x 1.2mm GI C Stud frame (600mm C.C) as shown in the drawings. (All angles to be marked and confirmed with Acoustic consultant-All proprietary accessories and hardware to be used for the GI Framing sections as per the guidelines of the OEM.-The foot runner to be affixed to the floor as per OEM Specifications and Architect details-The head runner to be affixed to the Isolation ceiling as per OEM Specifications-100mm 64Density Rockwool Insulation to be filled in the GI frame backed with a chicken mesh (or Nylon mesh) so as to prevent the spill out of rockwool into the air gaps.- The GI Frame will be cladded with 1x12mm Perforated Plywood Board.All speaker enclosures to be followed as per Setout plan and section and their constructional details |
| 230 | TREATMENT BAND 1:-Supply and Fix 18mm Birch Plywood sides. With 18mm Trim as per the shared schematics The depth of the band is 125mm as per the shared schematics-Providing nylon mesh to maintain an Air-Gap of 25mm from the Perforated gypsum-Affix 50mm 1200GSM Aero fill-Affix 50mm Basotect Foam above Aero fill-Affix 12mm Fabric Tracking System over the 18mm Plywood sides as shown.-final finish fabric to be installed as per approved details by architect |
| 231 | SPEAKER BAND:-All Speaker boxing to be built with 1x18mm Birch Plywood. Dimensions to be followed as per the shared schematics.-Affix 25mm AB Foam to be lined in the 18mm Ply boxing around the demarcated space to Fix SLS WMA-15 Wall Mount Rigging Kit.-Affix 12mm Fabric Tracking System over the lip of the speaker boxing as per the shared schematics |
| 232 | TREATMENT BAND 2:-Supply and Fix 18mm Birch Plywood sides. With 18mm Trim as per the shared schematics The depth of the band is 125mm as per the shared schematics-Providing nylon mesh to maintain an Air-Gap of 50mm from the Perforated gypsum-Affix 50mm 1200GSM Aero fill-Affix 25mm Basotect Foam above Aero fill-Affix 12mm Fabric Tracking System over the 18mm Plywood sides as shown.-final finish fabric to be installed as per approved details by architect |
| 233 | DELOCALISATION SLATS:-Supply and Fix 50x25mm Hardwood Frame in the level of fabric to provide supports to affix wooden slats-Supply and Fix 50x30mm Wooden Slats as per the shared schematics-Final finishes to be as per architect\"s specifications |
| 234 | COVE FOR LIGHTING:-Prepare a cove using 18mm Birch Plywood above the modules to fix the LED Strip light as per the shared scheme.-LED Strip Light Specifications as per architect\"s requirements-All finishes to be as per architect\"s specifications |
| 235 | REMOVABLE SKIRTING:-Prepare the removable assembly as shown in the schematic using 18mm Birch Plywood for the sides and 12mm Birch Plywood Board for the back and removable front-The removable front to be affixed to the assembly using suitable hardware\"s-All finishes to be as per architect\"s specifications |
| 236 | -Supply and fix 20mm 1200x600mm & 600x600mm Acoustic Grid ceiling tile suspended from the Isolation ceiling with necessary framing system and hardware as per OEM Specification-50mm 64 density rockwool insulation to be filled in the framing voids |
| 237 | WALL SPEAKER:-Supply and fix 90x30x600mm Hardwood support inside the 92mm Stud to Fix the speaker boxing as per the shared schematics.-The treatment in the speaker boxing as per the speaker band details |
| 238 | CEILING SPEAKER:\"-Supply and affix the HD1 Type AV Hangers (in line with the drawings and specifications to be approved by the Acoustic Consultants based on test reports shared by the contractor) as per the shared schematic to the Isolation ceiling by means of suitable hardware as per the shared schematics-Providing groove in the SLS FCT-24 Flat Mount Rigging Kit to suspend the same-SLS FCT -24 Flat Mount Rigging Kit to be suspended to the groove in the Ceiling Hangers by means of suitable hardware as per the shared schematics-AV Hanger with a point load capacity of 60kg per hanger to be used. |
| 239 | SURROUND SUBWOOFER:\"-Supply and affix the HD1 Type AV Hangers (in line with the drawings and specifications to be approved by the Acoustic Consultants based on test reports shared by the contractor) as per the shared schematic to the Isolation ceiling by means of suitable hardware as per the shared schematics-Suspending SLS 118-I to the groove in the Ceiling Hangers by means of suitable hardware as per the shared schematics.-AV Hanger with a point load capacity of 60kg per hanger to be used. |
| 240 | -Supply and fix 25mm Birch Plywood Window frame as per the shared schematics The glazing assembly of the window to be as follows:-6mm+1.52PVB+6mm Extra Clear Toughened Laminated Glass-Airgap as per schematics-8mm+1.52PVB+8mm Extra Clear Toughened Laminated Glass-25mm AB Foam in the Framing void-Silica Gel layer bed to avoid Moisture |
| 241 | -Supply and fix 9MM Laminated Floor with Suitable underlay as per the OEM Specifications-Finishes and Shades as per Architect Specifications |
| 242 | Supply and installation of peripheral False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by usingStrut ceiling framework. TheStrut ceiling framework system shall includeStrut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centres. Then suspendStrut MC45 Main channels, fully knurled,sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centres withStrut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm.Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mmand equal flanges 9.5mm is fastened to theStrut MC45 perpendicularly at 600mm centres.tufbloc HDFR, 1200x2400x10mm is installed on theStrut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Approved Makes- Anu tone/Gyproc/Amstrong/Equivalent |
| 243 | Supply and installation ofSkyline hard wood diffusers: Solid teak wood skyline diffusers of base plate 1000x1000x100mm. Each diffuser is made of 100mm thick block hard wood placed on the base plate based on the design provided to address specific frequencies. The assembly of wood pieces on each base board will be provided by the design consultant and to be followed exactly as per the design. The placement of each diffusers will be as per drawings issued to the contractor. Each diffuser should be mounted on the walls and ceiling using a Z clamp to have a stable fixing. |
| 244 | Supply and Installation of Acoustic polyether foam base traps of minimum size of 610x280x280 for corners and 600x600x50mm pyradid base base traps for the ceilings & wall surfaces( Minimum 8 nos of corner and 20 nos for walls & ceiling) |
| 245 | Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200 mm X 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 850 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer \"T\" profile etc. Cost of Laminate Floor Accessories only (Skirting ,End edge, T- moulding,Reducer) shall have to be added separately, wherever required. (Type and design to ce confirmed by Consultant/ Architect/ Client) |
| 246 | Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1500mm(W) x 2400mm(H)Wall Opening Width (W): 1500mmWall Opening Height(H): 2400mmProfile Size – Single Rebate: 100*58Door Thickness: 46mmInfill Material: 50mm with density 1000GSMFrame Sheet Tickness:1.6mmShutter Sheet Thickness: 1.2mmFinish- PU Paint/ LaminateDoor Type: Fire Door with Acoustic TreatmentNumber of Door Leaf: SingleDoor Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM)Door (Drop) Bottom Seal.STC of no less than 45 |
| 247 | Supply and installation ofAcoustic Wall Panels of size 1200x600x25mm: Supply and Installation ofAcoustic Soak Cord, square edge, fabric wrapped pinewood fiber core panel of size 600x1200x25 / 600X600X25 mm,with ribbed finish, volume density 400Kgs/m3, weight 10kg/m2 installed by using Strut Z bar. Strut Z bars having40mm height, thickness 1mm is first fixed behind the panels by using suitable fasteners. Another length of Strut Z bars to be fastened perpendicular to wall. Soak cord, square edge panels are then slided on to Strut Z bar to fix on the wall surface. Technical Parameter Fire (Class) – 1 & P Acoustics – NRC 0.9 Thermal conductivity (W/mk)– 0.08, Climate (°C, RH) – 50, 90, Light reflectance (%) – colour dependant,Green (VOC, RC %) – Low,30.Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent |
| 248 | Part 5.HVAC works |
| 249 | DRISHYA BUILDING - SITC , Unloading, leading, positioning of 2.0 TR Four way casette type Unit Split Air Conditioner with rotary compressor or to Suit for (Camera Lens Storage Room). Unit shall be supplied along with remote control .(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered in the unit price. The cost is inclusive of Communication cable between IDU to ODU. |
| 250 | SITC Copper Pipe for Both Suction and Liquid line along with insulation as per piping specs - Unit 1 |
| 251 | SITC Copper Pipe for both Suction and Liquid linealong with insulation as per piping specs -Unit 2 |
| 252 | SITC , Unloading, leading, positioning 1.0 TRFour way cassette type IDU for (Store manager Room).Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 253 | SITC , Unloading, leading, positioning 1.5 TRFour way cassette type IDU for (Construction Wing).Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 254 | SITC , Unloading, leading, positioning 2.0 TR Four Way Cassette type Unit IDU for (Lobby).Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 255 | SITC , Unloading, leading, positioning 2.0 TRFour way cassette type IDU for (AAO Room).Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 256 | SITC , Unloading, leading, positioning 1.5 TRFour way cassette type IDU for Library. Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 257 | SITC , Unloading, leading, positioning 2.0 TRFour way cassette type IDU for Electronic Store. Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 258 | SITC , Unloading, leading, positioning 3.0 TRFour way cassette type IDU for Accounts Office. Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 259 | SITC , Unloading, leading, positioning 2.0 TRFour way cassette type IDU for Admin Office. Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 260 | SITC,Unloading, leading, positioning16 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit Totaling to 32 HP) withcompressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc. to be considered. (Basement). Unit with lower power consumption at full load / Part load will be preferred. All compressors shall be of full inverter type |
| 261 | SITC ofInterconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF |
| 262 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units.- Pipe Line Size -5/8\" |
| 263 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units.-Pipe Line Size -3/8\" |
| 264 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units.- Pipe Line Size -1/2\" |
| 265 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/4\" |
| 266 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units. Pipe Line Size - 3/4\" |
| 267 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 1/8\" |
| 268 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 3/8\" |
| 269 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units- Pipe Line Size -7/8\" |
| 270 | SITC of Refrigerant Gas. |
| 271 | SITCof condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of sizefrom the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber or as required to avoid sweating. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site |
| 272 | Supply of Remote control for each units |
| 273 | Supply and fixing of Refnet Joints |
| 274 | SITC of Fresh Air Filter |
| 275 | SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 276 | SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 277 | SITC of 100 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 278 | SITC Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (950 Cfm) Electrical Panel Room |
| 279 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (700 cfm) - Electrical Panel Room |
| 280 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Spare room |
| 281 | SITC Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (500 Cfm) Temperature Holding Area |
| 282 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (600 cfm) - Temperature Holding Area |
| 283 | SITCAir Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (500 Cfm) Light Ancillary Area |
| 284 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Light and Ancillary Area |
| 285 | SITC Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (800 Cfm) - Rental Dispatch Area |
| 286 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (950 cfm) - Rental Dispatch Area |
| 287 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (700 cfm) - Receiving Area |
| 288 | SITC Exhaust Air Fan with min static of 15 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (1700 cfm) - Central Store Area ( Inline High Static Low Noise Fan) |
| 289 | SITCAir Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (600 Cfm) - Central Store Area |
| 290 | Supply and fixingof 24G G.I Sheet (Up to 750mm) for GI ductingfor fresh air |
| 291 | Supply and fixing of Canvas Connection for the inlet and outlet of Exhaust Fan For Central Store Area |
| 292 | Supply and fixing of Grill Horizontal For Central Store Area |
| 293 | SITC , Unloading, leading, positioning8.5 TR Ductable Split Unit circuit with air cooled outdoor unit SCROLL compressor (Inverter compressor can also be considered based on OEM availability), having suitable condenser fan / or as per OEM recommendation andseparate isolators to be provided for each unit towards maintenance purpose . The Unit shall have all interconnecting communication cables so as to have effective communication between IDU & with ODU. The price quoted shall be inclusive of IDU and ODU with necessary supporting arrangements for the units indoor and outdoor as required at site |
| 294 | Supply and layingof Communication Cable between IDU and Outdoor unit to suit |
| 295 | SITC , Unloading, leading, positioning 3.0 TRFour way cassette type IDU for (Camera Room 1).Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 296 | SITC , Unloading, leading, positioning 3.0 TRFour way cassette type IDU for (Camera Room 2)- Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 297 | SITC , Unloading, leading, positioning 4 TRFour way cassette type IDU for (Equipment Store)- Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 298 | SITC , Unloading, leading, positioning 2 TRFour way cassette type IDU for (AC Customer Lobby) - Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 299 | SITC , Unloading, leading, positioning 3 TRFour way cassette type IDU for (Shooting Lobby) - Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 300 | SITC , Unloading, leading, positioning 2 TRFour way cassette type IDU for (Documentary Section)- Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 301 | SITC , Unloading, leading, positioning 1.5TRFour way cassette type IDU for (VIP room) - Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 302 | SITC , Unloading, leading, positioning 2.0 TRFour way cassette type IDU for (Mini Theatre) - Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 303 | SITC,Unloading, leading, positioning28 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit) withcompressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc. to be considered. (Basement). Unit with lower power consumption at full load / Part load will be preferred. All compressors shall be of full inverter type. |
| 304 | Supply and laying of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF |
| 305 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -5/8\" |
| 306 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -3/8\" |
| 307 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/2\" |
| 308 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/4\" |
| 309 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/4\" |
| 310 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 1/8\" |
| 311 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 3/8\" |
| 312 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -7/8\" |
| 313 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Suction Line -1 1/8\" |
| 314 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Liquid Line - 5/8\" |
| 315 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Suction Line -1 1/8\" |
| 316 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Liquid Line - 5/8\" |
| 317 | SITC of Refrigerant Gas - VRF |
| 318 | SITC of Refrigerant Gas - Ductable Unit |
| 319 | SITCof condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of sizefrom the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber or as required to avoid sweating. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site |
| 320 | Supply of Remote control for each units |
| 321 | SITC of Refnet Joints |
| 322 | SITC of Rectangle duct with necessary fittings and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted toclient approval. - 24G G.I Sheet (Up to 750mm) |
| 323 | SITC of Rectangle duct with necessary fittings and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted toclient approval - 22G G.I Sheet (from 751 - 1500 mm) |
| 324 | SITC of Rectangle duct with necessary fittings and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted toclient approval - 20G G.I Sheet (From 1501 - 2250mm) |
| 325 | SITC of Canvas (Fire retardent) along with Damper for supply air for all the units Size - To suit |
| 326 | SITC of VCD (Volume Control Damper)- with Multi Opposed Blade type & frame shall be with Galvanized Iron with min thickness of 18 gauge of frame and min 20 G thick blade shall be used. |
| 327 | SITC of Fresh air damper with pre filter to suit |
| 328 | SITC of Fire Damper with Fusible link to suit the return air (Fire dampers shall be with at least 1.5 hours fire rating. Damper blades shall be one piece folded construction manufactured from high strength galvanized steel Opposed blade type. Damper frames shall be of 18 gauge GI and the blades of min 20 gauge GI). |
| 329 | SITCair grills / diffusers shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars - Air Grill with Damper |
| 330 | SITC return air grills / diffusers shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars - RA Grill |
| 331 | Supply & fixing of thermal insulation with min 9 mm thick closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum,Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided. |
| 332 | Supply & fixing of acoustic insulation with 10 mm thick open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type. |
| 333 | Supply and installation of fresh air filter |
| 334 | SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 335 | SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 336 | SITC of 100 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 337 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (250 cfm) - Staff Outdoor Unit Room 1 |
| 338 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (250 cfm) - Staff Out door unit Room 2 |
| 339 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (500 cfm) - Staff Out door unit Room 3 |
| 340 | SITCAir Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (800 Cfm) - Receiving Area |
| 341 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (950 cfm) - Receiving Area |
| 342 | SITC Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (300 Cfm) - VRF IDU Fresh Air Supply (Documentation Area) |
| 343 | SITC , Unloading, leading, positioning of 4.0 TRFour way cassette type Unit or to Suit for (Projection Room) Unit shall be supplied along with remote control.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered. Communication cable between IDU to ODU shall be considered by the bidder and the cost shall be included in this price quoted |
| 344 | Supply and layingof Copper pipe (Both Suction and Liquid line to be considered for costing) for the units along with insulation as per piping specs - Unit 1 |
| 345 | SITC , Unloading, leading, positioning 1.5 TRHi wall Mount type IDU for (Edit Room) |
| 346 | SITC , Unloading, leading, positioning 2.0 TRHi wall Mount for (Server Room) |
| 347 | SITC , Unloading, leading, positioning 3 TRFour way cassette type IDU for (VFX Room) |
| 348 | SITC , Unloading, leading, positioning 4 TRFour way cassette type IDU for (View Hall) |
| 349 | SITC , Unloading, leading, positioning 2 TRFour way cassette type IDU for (Edit Suite 1) |
| 350 | SITC , Unloading, leading, positioning 2 TRFour way cassette type IDU for (Edit Suite 2) |
| 351 | SITC , Unloading, leading, positioning 2 TRFour way cassette type IDU for (Edit Room) |
| 352 | SITC , Unloading, leading, positioning 2 TRFour way cassette type IDU for (HOD Room) |
| 353 | SITC,Unloading, leading, positioning 16 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit total of 32 HP) withcompressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc. to be considered. (Basement). Unit with lower power consumption at full load / Part load will be preferred. All compressors shall be of full inverter type |
| 354 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -5/8\" |
| 355 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -3/8\" |
| 356 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/2\" |
| 357 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/4\" |
| 358 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/4\" |
| 359 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 1/8\" |
| 360 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 3/8\" |
| 361 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -7/8\" |
| 362 | Supply and filling of Refrigerant Gas . |
| 363 | SITCof condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of sizefrom the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. |
| 364 | Supply of Remote control for each units |
| 365 | Supply and fixing of Refnet Joints |
| 366 | Supply and layingof Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM |
| 367 | SITC of Drain Pump for Hi wall Mount VRF / and for independent Split Unit as required |
| 368 | SITC , Unloading, leading, positioning of2.0 TRHigh Wall type Unit (SERVER ROOM). Unit shall be supplied along with remote control Split Air Conditioner with rotary compressor.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Unit shall be supplied along with remote control. Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered in the unit price. Communication cable between IDU to ODUshall be inclusive of this cost. |
| 369 | Supply and laying of Copper Pipe (Cost inclusive of Both Suction and Liquid line ) for the units along with insulation as per piping specs. - Unit 1 |
| 370 | Supply and fixingof Fresh Air Filter |
| 371 | SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 372 | SITC of 100 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 373 | SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Store Room |
| 374 | Supply and fixingAir Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (300 Cfm) - View Hall / Edit Suite Cassette Unit FA Supply |
| 375 | Supply and laying of Rubber pads for out door units |
| 376 | Supplying, Fabrication of MS Structural support / Channelsfor IDU s / ODU Sto suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc. to be provided (For Basement / G floor and First Floor) |
| 377 | Any Other Miscellaneous Charges requiredfor the completion of HVAC works. |
| 378 | Supply, Installation, Leading, Positioning, Testing and commissioning of 44TR Capacity (To Suit) of 17600CFM, 55 mm static pressure,Floor mounted Double Skin, (48 - 50mm thick PUF panels, density of 40kg/cum,with min 0.6-mm thick inner & 0.8-mm outer skin) air-handling units, with Thermal break profile, Pre-filter section with Pre-filters (90% down to 10 micron) with highest Efficiency alongfilter frame. The Ahu shall be with preferably 6 row DX Cooling coil section to suit the ODU Selected along with the AHU for Thiruvanthapuram climate. The AHU shall have a drain pan with min 1.2-mm thick Stainless steel (SS 304) material. Pan should be Insulated with min 9-mm thick Nitrile rubber at the bottom. Copper tubes selected shall be of preferably 0.5mm thick and min of 12 Fins Per inch shall be maintained. The contractor should consider suitable expansion Valve, Filter Drier (AHU KIT if any) so that the AHU is coupled with the selected ODU. Ahu shall also have a DIDW fan blower with fan motor of minimum IE 3 Motor (IE 2 can be provided only if IE 3 is not available for that capacity), fan with drive coupling to suit, along with necessary mounting frame, Vibration isolators, 2 MM GI base frame, Aluminium structural frame work, Fire retardant flexible connection, Marine light, Access door and Access door limit switch, View port for fan section, accessories and as per technical specifications. Coils shall be sized to meet conditions provided in AHU specifications. The Coil face velocity shall not exceed 2.5 M/s. The quoted price shall include the cost of supply, installation, testing and commissioning of air handling unit wall mountable electrical starter panel , main circuit breaker, LCD screen with temperature indicator. Panel shall be preferably wall mounted type, powder coated type. The electrical panel shall have potential free relay contacts to be interlocked with fire alarm control module & BMS on/off command, trip status. |
| 379 | SITC of 11 TR / 12 TR Condensing unitcomprising ODU with Scroll compressor and condenser fan unit to suit the above indicated AHU. The contractor shall consider all the interconnecting circuit components required for connecting the AHU including safety & communication between the AHU & ODU. |
| 380 | Supply and laying of Communication & Power Cable between AHU and Outdoor unit to suit |
| 381 | Supply of Panel for AHU (Each Panel to have a switch on / off control of 44 TR Capacity i.e. 11 X 4 Units) |
| 382 | SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between condensing unit & indoor units - Suction Line -7/8\" |
| 383 | SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between condensing unit & indoor units - Liquid Line - 1 1/8\" |
| 384 | Supply and fillingof Refrigerant Gas |
| 385 | SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of sizefrom the indoor unit up to the nearest drain point . |
| 386 | SITC of Rectangle duct with necessary supporting arrangements,standards of sizing and supporting arrangements - 24G G.I Sheet |
| 387 | SITC of Rectangle duct with necessary supporting arrangements,standards of sizing and supporting arrangements - 22G G.I Sheet |
| 388 | SITC of Rectangle duct with necessary supporting arrangements,standards of sizing and supporting arrangements - 20G G.I Sheet |
| 389 | SITC of Rectangle duct with necessary supporting arrangements,standards of sizing and supporting arrangements - 18G G.I Sheet |
| 390 | Supply and erection of GI Spiral Ducting with necessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice and the cost is inclusive of necessary coating. 900 mmDia |
| 391 | Supply and erection of GI Spiral Ducting with necessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice and the cost is inclusive of necessary coating - 700mm Dia |
| 392 | Supply and erection of GI Spiral Ducting with necessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice and the cost is inclusive of necessary coating - 450 Dia |
| 393 | Supply and fixingof Canvas (Fire retardant) along with Damper for supply air for all the units Size - To suit |
| 394 | Supply and fixing of VCD for controlling air flow on Main ducts |
| 395 | Supply and fixingof Fresh air damper with pre filter to suit |
| 396 | Supply and fixing of Fire Damper with Fusible link to suit the return air |
| 397 | SITC ofhorizontal continuous grill/diffusers of size - 450 Dia Jet Diffusers (24Nos) |
| 398 | Supply and fixing of RA Grill |
| 399 | Thermal Insulation - Supply & fixing of thermal insulation with closed cell anti microbial nitrile rubber for the additional new ducts if any provided for Recording theater along with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum,Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided. The thermal insulation with min 9 mm thick closed cell nitrile rubber with a wrap over the ducting. |
| 400 | Supply & fixing of thermal insulation with min 25 mm thick closed cell nitrile rubber (For Exposed Duct) with a wrap over the ducting. |
| 401 | Supply & fixing of acoustic insulation for the new additional ducts if any provided for the recording Theater with Minimum 10 mm thick or as required open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type. |
| 402 | Supply and fixing of Rubber pads for out door units |
| 403 | Supplying , Fabrication of MS Structural support / Channelsfor IDU s / ODU Sto suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc. to be provided |
| 404 | Any Other Miscellaneous Charges requiredfor the completion of HVAC works. |
| 405 | Shifting,Leading, Positioning,re installing,Testing and commissioning of 17 TR x 2 Nos of existing Packaged Unit along with necessary out door units (8.5 TR X 2 units or as with available combination with client place) and fixing the same near the Medium floor AHU room indicated in the drawing. Vendor shall ensure that unit is properly shifted without any damage and shall ensure that the unit shall work to its rated capacity as it is an un used existing units. Any repair work to ensure the unit working to its fullest capacity will be in vendors scope for which the vendor can inspect the units if required. The quoted price shall include the cost of installation, testing, repairing if any andcommissioning of electrical indoor / microprocessor unit starter panel (provided with the unit), and its related main circuit breaker, Display screen with temperature indicator. The electrical / microprocessor panel shall be added with a potential free relay contacts which can be interlocked with fire alarm control module & BMS on/off command, trip status. The price quoted shall be inclusive of indoor / outdoor unit shifting etc. and its related work in total including any repair works till proper commissioning and handing over the same to client use. |
| 406 | Supply and layingof Communication & Power Cable between Packaged unit to the Outdoor unit so asto suit |
| 407 | SITC, I.e Supply ,Installing, testing, commissioning including Leading, Positioning, of 8.5 / 8.75 TR or as per nearest available capacity by OEM Ductabletype Packaged Unit along with necessary out door units (8.5 TR / 8.75 / or to suit X 1 units as available) and fixing the same near the Medium floor AHU room as indicated in the drawing. Vendor shall ensure that unit is properly supplied, integrated with the 2 nos of 17 TR units in the plenumand shall ensure that the unit shall work to its rated capacity. The quoted price shall include the cost of installation, testing,andcommissioning of electrical indoor unit starter panel (provided with the unit), and its related main circuit breaker, Display screen with temperature indicator. The electrical panel / microprocessor panelshall be added with a potential free relay contacts which can be interlocked with fire alarm control module & BMS on/off command, trip status. Unit shall have all requisite micro processor units for controlling the temperature and it shall have an option of switching over the operation of compressor when it is more than one number of compressor. |
| 408 | SITC of Outdoor unit 8.5 TR to suit the packaged unit supplied |
| 409 | Supply and laying of Communication & Power Cable between Packaged unit to the Outdoor unit so asto suit with requisite supports. |
| 410 | SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting for the Packaged units as per the colour approved by client / standards. In case if the piping requires insulation in any area, thenthe same shall be done for the all the lines as required with fittings, valves, and strainer bodies etc. with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber for all the units. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between condenser unit & indoor Packaged units - PACKAGE 17TR (2Units) - Liquid Line -5/8\" |
| 411 | SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting for the Packaged units as per the colour approved by client / standards. In case if the piping requires insulation in any area, thenthe same shall be done for the all the lines as required with fittings, valves, and strainer bodies etc. with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber for all the units. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between condenser unit & indoor Packaged units - PACKAGE 17TR (2Units) - Discharge Line - 7/8\" |
| 412 | SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting for the Packaged units as per the colour approved by client / standards. In case if the piping requires insulation in any area, thenthe same shall be done for the all the lines as required with fittings, valves, and strainer bodies etc. with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber for all the units. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between condenser unit & indoor Packaged units - PACKAGE 8.5TR (1Unit) - Liquid Line -5/8\" |
| 413 | SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting for the Packaged units as per the colour approved by client / standards. In case if the piping requires insulation in any area, thenthe same shall be done for the all the lines as required with fittings, valves, and strainer bodies etc. with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber for all the units. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between condenser unit & indoor Packaged units - PACKAGE 8.5TR (1Unit) - Discharge Line - 7/8\" |
| 414 | Supply and filling of Refrigerant Gas |
| 415 | SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of sizefrom the indoor unit up to the nearest drain point. |
| 416 | SITC of Rectangle duct with necessary supporting arrangements, withstandardsizing and supporting arrangements - 24G G.I Sheet |
| 417 | SITC of Rectangle duct with necessary supporting arrangements, withstandardsizing and supporting arrangements - 22G G.I Sheet |
| 418 | SITC of Rectangle duct with necessary supporting arrangements, withstandardsizing and supporting arrangements - 20G G.I Sheet |
| 419 | SITC of Rectangle duct with necessary supporting arrangements, withstandardsizing and supporting arrangements - 18G G.I Sheet |
| 420 | Supply and erection of GI Spiral Ducting with necessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice on colour and the cost is inclusive of necessary coating -600mm Dia |
| 421 | Supply and erection of GI Spiral Ducting with necessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice on colour and the cost is inclusive of necessary coating - 550mm Dia |
| 422 | Supply and erection of GI Spiral Ducting with necessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice on colour and the cost is inclusive of necessary coating- 350mm Dia |
| 423 | Supply and fixingof Canvas (Fire retardant) along with Damper for supply air for all the units Size - To suit |
| 424 | Supply and fixing of VCD for controlling air flow on Main ducts |
| 425 | Supply and fixingof Fresh air damper with pre filter to suit |
| 426 | Supply and fixing of Fire Damper with Fusible link to suit the return air |
| 427 | SITC ofhorizontal continuous grill/diffusers of sizes 350mm Dia Jet Diffusers (24Nos) |
| 428 | Supply and fixingof RA Grill |
| 429 | Thermal Insulation - Supply & fixing of thermal insulation with closed cell anti microbial nitrile rubber .(Insulation material shall have a density of 60Kg/Cum,Class - O Type) Ducting insulation shall be done with in the inside surface of the duct and externally powder coating of the duct with requisite color shall be provided for the duct as per client requirement. Thermal insulation with min 9 mm thick closed cell nitrile rubber within ducting. |
| 430 | Supply & fixing of thermal insulation with min 25 mm thick closed cell nitrile rubber (For Exposed Duct) with al.foil finish and a UV wrap over the ducting wherever applicable. |
| 431 | Supply & fixing of acoustic insulation for the ducts provided with Minimum 10 mm thick or as required open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type. |
| 432 | Supply and fixingof Rubber pads for out door units |
| 433 | Supplying, Fabrication of MS Structural support / Channelsfor IDU s / ODU Sto suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc. to be provided |
| 434 | Miscellaneous chargeslike, required civil works etc.for completing HVAC (demolishing & finishing the damaged portion) |
| 435 | DI building - SITC , Unloading, leading, positioning8.5 TR Ductable Split Unit circuit with air cooled outdoor unit SCROLL compressor (Inverter compressor can also be considered based on OEM availability), having suitable condenser fan / or as per OEM recommendation andseparate isolators to be provided for each unit towards maintenance purpose . The Unit shall have all interconnecting communication cables so as to have effective communication between IDU & with ODU. The price quoted shall be inclusive of IDU and ODU with necessary supporting arrangements for the units indoor and outdoor as required at site |
| 436 | Supply and laying of Communication Cable between IDU and Outdoor unit to suit |
| 437 | SITC of Rectangle duct with necessary fittings, standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by client. Bidder to ensure that the duct is supported with necessary stiffeners etc. to handle the insulation weight as duct is insulated both acoustically and thermally for full length - 24G G.I Sheet (Up to 750mm) |
| 438 | SITC of Rectangle duct with necessary fittings, standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by clientconsultant. Bidder to ensure that the duct is supported with necessary stiffeners etc. to handle the insulation weight as duct is insulated both acoustically and thermally for full length - 22G G.I Sheet (from 751 - 1500 mm) |
| 439 | SITC of Rectangle duct with necessary fittings, standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by clientconsultant. Bidder to ensure that the duct is supported with necessary stiffeners etc. to handle the insulation weight as duct is insulated both acoustically and thermally for full length - 20G G.I Sheet (From 1501 - 2250mm) |
| 440 | SITC of Canvas (Fire retardant) along with Damper for supply air for all the units Size - To suit |
| 441 | SITC of VCD (Volume Control Damper)- with Multi Opposed Blade type & frame shall be with Galvanized Iron with min thickness of 18 gauge of frame and min 20 G thick blade shall be used. |
| 442 | SITC of Fresh air damper with pre filter to suit |
| 443 | SITC of Fire Damper with Fusible link to suit the return air (Fire dampers shall be with at least 1.5 hours fire rating. Damper blades shall be one piece folded construction manufactured from high strength galvanized steel Opposed blade type. Damper frames shall be of 18 gauge GI and the blades of min 20 gauge GI). |
| 444 | The supply and fixingreturn air grills / diffusers shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars. In case of diff size of grills / diffusers used then the same shall be considered in sq mtr value to the nearest thickness / sizes. The colour of the grill shall be decided by clientand contractor to ensure that the requisite colour of grill is supplied without any additional cost. (Horizontal Continuous grill of 6 inch height with 15 deg c Deflection or as required at site)-Air Grill with Damper |
| 445 | Supply and fixing of RA Grill |
| 446 | Supply & fixing of thermal insulation with min 9 mm thick closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum,Class - O Type) and min 0.7 mm thick Aluminium cladding over the insulation shall be provided. (Cost is inclusive of Duct support for handling insulation units |
| 447 | Supply & fixing of acoustic insulation with 20 mm thick open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type. (Cost is inclusive of Duct support for handling insulation units.) |
| 448 | SITC of 2.0 TRFour way cassette type Air Conditioner (Confirmation Room 1 & 2)consisting of total unit including Grills etc. along with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 449 | SITC of 2.0 TRFour way cassette type Air Conditioner (Discussion room)consisting of total unit including Grills etc. along with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 450 | SITC of 2.0 TRFour way cassette type Air Conditioner (Reception)consisting of total unit including Grills etc. along with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 451 | SITC of 1.5 TRFour way casette type Air Conditioner (HOD room)consisting of total unit including Grills etc. along with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 452 | SITC,Unloading, leading, positioning10 HP Min CapacityVariable Refrigerant Flow Outdoor unit withcompressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc. to be considered. Unit with lower power consumption at full load / Part load will be preferred. |
| 453 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 1 - Suction Line -1 1/8\" |
| 454 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 1 - Liquid Line - 5/8\" |
| 455 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 2 - Suction Line -1 1/8\" |
| 456 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 2 - Liquid Line - 5/8\" |
| 457 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 3 - Suction Line -1 1/8\" |
| 458 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 3 - Liquid Line - 5/8\" |
| 459 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size -5/8\" |
| 460 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polychelid coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size -3/8\" |
| 461 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size -7/8\" |
| 462 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size -1/2\" |
| 463 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size -1/4\" |
| 464 | SITC of Refrigerant Gas - VRF |
| 465 | SITC of Refrigerant Gas - Ductable Unit |
| 466 | SITCof condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of sizefrom the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site |
| 467 | Supply of Remote control for each units |
| 468 | Supply and fixing of Refnet Joints |
| 469 | Supply and laying of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF |
| 470 | SITC , Unloading, leading, positioning of 3 TR Four Way Cassette Type Units along with Remote Control for Projection room (Working Unit) Split Air Conditioner with rotary compressor.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Cos is inclusive of Supports for IDU and ODU including Stabilizer (Minimum Double Booster) andCommunication cable between IDU to ODU. |
| 471 | SITC , Unloading, leading, positioning of 2 TR High Wall Mount Unit along with Remote Control for Projection room (Standby Unit) Split Air Conditioner with rotary compressor.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Cos is inclusive of Supports for IDU and ODU including Stabilizer (Minimum Double Booster) andCommunication cable between IDU to ODU. |
| 472 | Supply of copper pipes both suction and Liquid line - Unit 1 (Cassette Type) |
| 473 | Supply of copper pipes both suction and Liquid line - Unit 2 (Hi wall Type Stand By) |
| 474 | SITC of 2 TR High Wall Mount Units along with Remote Control for SERVER ROOM - (1 Working and 1 Standby Unit) |
| 475 | Supply and layingof copper pipes both suction and Liquid line - Unit 1 (Hi wall Type Working) |
| 476 | Supply and laying of copper pipes both suction and Liquid line - Unit 2 (Hi wall Type Stand By) |
| 477 | SITC of 3 TR Four Way Cassette Type Units along with Remote Control for Projection room (Working Unit) for DI 3 |
| 478 | SITC of 2 TR High Wall Mount Units along with Remote Control for Projection room (Standby Unit) for DI 3 |
| 479 | Supply and laying of copper pipes both suction and Liquid line - Unit 1 (Cassette Type) |
| 480 | Supply and laying of copper pipes both suction and Liquid line - Unit 2 (Hi wall Type Stand By) |
| 481 | SITC of Drain Pump for Hi wall Mount VRF / Split AC Unit as required. (For Cassette Unit inbuilt drain pump is considered) |
| 482 | Supply and fixingof Rubber pads for out door units |
| 483 | Supply, Fabrication of MS Structural support / Channelsfor IDU s / ODU Sto suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc. to be provided |
| 484 | Supply and fixing of Fresh Air Filter |
| 485 | SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required for VRF IDU FA / Individual Cassette ACConnection |
| 486 | SITCAir Fan with min static of 15-20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (300 cfm) Battery Room |
| 487 | SITC of Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Battery Room |
| 488 | SITC of Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Stores |
| 489 | SITC Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (250 cfm) DI Suite room 3 |
| 490 | Miscellaneous chargeslike, required civil works etc.for completing HVAC (demolishing & finishing the damaged portion) |
| 491 | OFFICE BUILDING - SITC of2.0 TRFour way Cassette Type IDU / Hi wall Mount Unit ( Chairman room). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 492 | OFFICE BUILDING - SITC of1.5 TRFour way Cassette Type IDU / Hi wall Mount Unit (M.D room). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 493 | OFFICE BUILDING - SITC of3.0 TRFour way Cassette Type IDU / Hi wall Mount Unit (Board room). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 494 | OFFICE BUILDING - SITC of1.5 TRFour way Cassette Type IDU / Hi wall Mount Unit (Studio manager room). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 495 | OFFICE BUILDING - SITC of2.0 TRFour way Cassette Type IDU / Hi wall Mount Unit (PRO). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 496 | OFFICE BUILDING - SITC of3.0 TRFour way Cassette Type IDU / Hi wall Mount Unit (Reception & Waiting Longue). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 497 | OFFICE BUILDING - SITC of1.5 TRFour way Cassette Type IDU / Hi wall Mount Unit (Huddle room - 1). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 498 | OFFICE BUILDING - SITC of1.5 TRFour way Cassette Type IDU / Hi wall Mount Unit (Huddle room - 2). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 499 | OFFICE BUILDING - SITC of2.0 TRFour way Cassette Type IDU / Hi wall Mount Unit (Office room). Unit shall be considered with Grills, and with drain pump etc. as required for complete installation including necessary supporting arrangement etc. |
| 500 | SITC,Unloading, leading, positioning24 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit) withcompressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc. to be considered. (Basement). Unit with lower power consumption at full load / Part load will be preferred. All compressors shall be of full inverter type. |
| 501 | Supply an layingof Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF |
| 502 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -5/8\" |
| 503 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -3/8\" |
| 504 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/2\" |
| 505 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/4\" |
| 506 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/4\" |
| 507 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 1/8\" |
| 508 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 3/8\" |
| 509 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -7/8\" |
| 510 | SITC , Unloading, leading, positioning of2.0 TR HI Wall Mount Unit - Split Air Conditioner with rotary compressor) or to Suit for (Chairman Room) Unit shall be supplied along with remote control.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. The cost is inclusive of Supports required for IDU and ODU including Stabilizer and Communication cable between IDU to ODU. |
| 511 | SITC , Unloading, leading, positioning of1.5 TR HI Wall Mount Unit - Split Air Conditioner with rotary compressor) or to Suit for (Chairman Room) Unit shall be supplied along with remote control.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. The cost is inclusive of Supports required for IDU and ODU including Stabilizer and Communication cable between IDU to ODU. |
| 512 | Supply and laying of Copper Pipe for both Suction and Liquid linealong with insulation as per piping specs - 2 TR Chair Man Room Unit (Piping) |
| 513 | Supply and laying of Copper Pipe for both Suction and Liquid linealong with insulation as per piping specs - 1.5 TR MD Room Unit (Piping) |
| 514 | Supply and fixing of Fresh Air Filter |
| 515 | SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 516 | SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 517 | SITC of 100 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 518 | SITC Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (400 Cfm) - To VRF Units (Inline high static Low Noise Fan) |
| 519 | SITC Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (300 Cfm) - To VRF Units (Inline high static Low Noise Fan) |
| 520 | SITC of Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Store room |
| 521 | SITC of 2.0 TRFour way Cassette Type IDU / Hi wall Mount Unit , inclusive ofGrills, and with drain pump etc.complete installation including necessary supporting arrangement etc.( VIP waiting area) |
| 522 | SITC , Unloading, leading, positioning 5.5 / 6(AS PER OEM AVAILABILITY) TR Ductable with Remote control (Corded Remote Preferably or as per client requirement) for (Dubbing) including all necessary kits for interconnecting with VRF. Unit shall also be supplied along with drain pump as required |
| 523 | SITC , Unloading, leading, positioning 2.0 TR Ductable with Remote control (Corded Remote Preferably or as per client requirement) for (Console) including all necessary kitsfor interconnecting with VRF. Unit shall also be supplied along with drain pump as required |
| 524 | SITC , Unloading, leading, positioning 2.0 TR Ductable with Remote control (Corded Remote Preferably or as per client requirement) for (Console) including all necessary kitsfor interconnecting with VRF. Unit shall also be supplied along with drain pump as required |
| 525 | SITC of 3.0 TRFour way Cassette Type IDU / Hi wall Mount Unit , inclusive ofGrills, and with drain pump etc.complete installation including necessary supporting arrangement etc.(Store room) |
| 526 | SITC of 3.0 TRFour way Cassette Type IDU / Hi wall Mount Unit , inclusive ofGrills, and with drain pump etc.complete installation including necessary supporting arrangement etc.(Reception and waiting longue) |
| 527 | SITC , Unloading, leading, positioning 3.0 TR Ductable with Remote control (Corded Remote Preferably or as per client requirement) for (Foley Studio) including all necessary kitsfor interconnecting with VRF. Unit shall also be supplied along with drain pump as required |
| 528 | SITC,Unloading, leading, positioning24 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit) withcompressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc. to be considered. (Basement). Unit with lower power consumption at full load / Part load will be preferred. All compressors shall be of full inverter type. |
| 529 | Supply and laying of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF |
| 530 | OFFICE BUILDING - SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -5/8\" |
| 531 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -3/8\" |
| 532 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/2\" |
| 533 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1/4\" |
| 534 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -3/4\" |
| 535 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 1/8\" |
| 536 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc. with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -1 3/8\" |
| 537 | SITC ofInter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units - Pipe Line Size -7/8\" |
| 538 | SITC of Rectangle duct with necessary fittings, following SMACNA standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by client . All ductings shall be suitably supported with necessary stiffeners provided on the ducts so as to reduce vibrations and to handle the insulation weight since complete ducts will be both thermally and acoustically insulated - 24G G.I Sheet (Up to 750mm) |
| 539 | SITC of Rectangle duct with necessary fittings, following SMACNA standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by client . All ducting\"s shall be suitably supported with necessary stiffeners provided on the ducts so as to reduce vibrations and to handle the insulation weight since complete ducts will be both thermally and acoustically insulated - 20G G.I Sheet (From 1501 - 2250mm) |
| 540 | SITC of Canvas (Fire retardant) for supply air for all the units Size - To suit |
| 541 | SITC of VCD (Volume Control Damper)- with Multi Opposed Blade type & frame shall be with Galvanized Iron with min thickness of 18 gauge of frame and min 20 G thick blade shall be used. |
| 542 | SITC of Fresh air damper with pre filter to suit |
| 543 | SITC of Fire Damper with Fusible link to suit the return air (Fire dampers shall be with at least 1.5 hours fire rating. Damper blades shall be one piece folded construction manufactured from high strength galvanized steel Opposed blade type. Damper frames shall be of 18 gauge GI and the blades of min 20 gauge GI). |
| 544 | supply and fixing of Air Diffuser / Grill with Damper, it shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars. The grills / diffusers selected shall have a low NC of around 25. In case of diff size of grills / diffusers used then the same shall be considered in sq mtr value to the nearest thickness / sizes. Diffuser colour shall be decided by clientand contractor has to ensure that the requisite colour of grill is supplied without any additional cost / i.e. inclusive ofcost of spray painting / coating. |
| 545 | supply and fixing ofDiffuser / RA Grill, it shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars. The grills / diffusers selected shall have a low NC of around 25. In case of diff size of grills / diffusers used then the same shall be considered in sq mtr value to the nearest thickness / sizes. Diffuser colour shall be decided by clientand contractor has to ensure that the requisite colour of grill is supplied without any additional cost / i.e inclusive ofcost of spray painting / coating. |
| 546 | Supply & fixing of thermal insulation with min 25 mm thick (for Exposed area) closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum,Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided. |
| 547 | Supply & fixing of thermal insulation with min 9 mm thick (for Non Exposed / Air conditioned area) closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum,Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided. |
| 548 | Supply & fixing of thermal insulation with min 50 mm thick Pharmocol with wire mesh wrapped and cement plastering done for the supply air / Return air ducting exposed to Atmosphere |
| 549 | Supply & fixing of acoustic insulation Minimum 20 mm thick or as required open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type.(Complete Duct for Dubbing, Console room - 2 nos and Foley studio shall be acoustically insulated) |
| 550 | Supply and fixing of Fresh Air Filter |
| 551 | SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc. as required |
| 552 | SITC of Refrigerant Gas - VRF |
| 553 | SITCof condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of sizefrom the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber or as required to avoid sweating. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site (Both Left & Right Wing) |
| 554 | Supply of Remote control for each units (Both Left and Right wing) |
| 555 | Supply and fixing of Refnet Joints (Both Left and Right wing) |
| 556 | SITC of Drain Pump for Hi wall Mount VRF / and for independent Split Unit as required for MD and Chair Man Room Stand By Units |
| 557 | Supply and fixing of Rubber pads for out door units |
| 558 | Supply, Fabrication of MS Structural support / Channelsfor IDU s / ODU Sto suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc. to be provided |
| 559 | Miscellaneous chargeslike, required civil works etc.for completing HVAC (demolishing & finishing the damaged portion) |
| 560 | Supply, Installation, Leading, Positioning, Testing and commissioning of 22 TR Capacity (To Suit) of 8800 CFM, 70 mm static pressure or to suit actual site condition, Floor mounted Double Skin, (46 - 48 mm thick PUF panels, density of 40kg/cum,with min 0.6-mm thick inner & 0.8-mm outer skin) air-handling units, with Thermal break profile, Pre-filter section with Pre-filters (90% down to 10 micron) with highest Efficiency alongfilter frame. The AHU shall be with preferably 6 row DX Cooling coil section to suit the ODU Selected along with the AHU for Thiruvanthpuram climate. AHU shall be acoustically insulated for the panels inside including fan housing for maintaining low noise. The AHU shall have a drain pan with min 1.2-mm thick Stainless steel (SS 304) material. Pan should be Insulated with min 9-mm thick Nitrile rubber at the bottom. Copper tubes selected shall be of preferably 0.5mm thick and min of 12 Fins Per inch shall be maintained. The Vendor should consider suitable expansion Valve, Filter Drier (AHU KIT if any) so that the AHU is coupled with the selected ODU. AHU shall have a DIDW fan blower or plug fan (having lower noise level and if required a higher size fan also be considered for the same to have lesser noise at lower RPM) with fan motor of minimum IE 3 Motor (IE 2 can be provided only if IE 3 is not available for that capacity), fan with drive coupling to suit, along with necessary mounting frame, Vibration isolators, 2 MM GI base frame, Aluminium structural frame work, Fire retardant flexible connection, Marine light, Access door and Access door limit switch, View port for fan section, accessories and as per technical specifications. Coils shall be sized to meet conditions provided in AHU specifications. The Coil face velocity shall not exceed 1.8 M/s. The quoted price shall include the cost of supply, installation, testing and commissioning of air handling unit wall mountable electrical starter panel , main circuit breaker, LCD screen with temperature indicator. Panel shall be with powder coated type. The electrical panel shall have potential free relay contacts to be interlocked with fire alarm control module & BMS on/off command, trip status. IMP NOTE: Vendor to note that Recording theatre is highly sensible to noise and hence it will be the vendors responsibility to fine tune the equipment during commissioning to the required CFM and to ensure that there is no air noise or AHU noise passing into to the room. The diffusers selected for the supply air shall also have a lower noise level for which necessary acoustic insulation as required shall be carried out by the vendor. The static pressure and fan supply air quantity shall be adjusted as per site requirement so that the noise level is not carried away to the recording theatre. |
| 561 | SITC of 11 TR / 12 TR Condensing unit (Inverter Type can also be quoted by Vendor) comprising ODU with Scroll compressor and condenser fan unit to suit the above indicated AHU. The vendor shall consider all the interconnecting circuit components required for connecting the AHU including safety & communication between the AHU & ODU. |
| 562 | Providing and laying communication Cable between AHU and Outdoor unit to suit |
| 563 | SITC Panel for AHU suitable for 11 TR/12 TR Condensing unit |
| 564 | Inspection / Removing of the ducting (Both Supply air and return air as applicable). The charges quoted shall be inclusive of providing necessary scaffoldings / Civil wall & floor breaking charges as required. with considering all safety norms as per local government rules. This item is only for removal of ducting charges including removal of thermal and acoustic insulation on ducting and positioning the debris / scrap items at suitable location as instructed by client in site where in the ducts cannot be re used. |
| 565 | Repairing/ Rectification / Refixing of the removed ducting (Both Supply air and return air as applicable) including necessary additional supports with vibration isolators as required to reduce vibration as much as possible and as per Standards / Site requirements. The charges quoted shall be inclusive of providing necessary scaffoldings / Civil wall & floor breaking charges/ Cleaning of ducts / as required (Manual / Robotic cleaning) in detail as per S.No II of this BOQ above, and with considering all safety norms as per local government rules. |
| 566 | Thermal Insulation of Ducting-Supply & fixing of thermal insulation in existing ducting (In Supply air duct and in Return air passage as required) with min 25 mm thick closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum,Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided as required at site. |
| 567 | Acoustic Insulation - Supply & fixing of acoustic insulation in existing ducting (In Supply air duct and in Return air passage as required) with minimum 20 mm thick or as required open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type. |
| 568 | SITC Sound Attenuators with minimum 20 mm thick acoustic insulation (Additionally as required) shall be fixed in the supply air and in the return air of the ducting preferably near the entry room of the supply air to theatre and at the RA starting point of the duct passage so that the noise carried away in the ducting shall be eliminated without entering the Recording Theatre. The Sound Attenuator is indicated in HVAC drawings, However the Vendor shall select the exact suitable location of the sound attenuator position as per site actual conditions. |
| 569 | Any Other Miscellaneous Charges requiredfor the completion of HVAC works. |
| 570 | SITC of Rectangle duct with necessary fittings, following SMACNA standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the consultant / client approval as and when required by clientconsultant. All ductings shall be suitably supported with necessary stiffeners provided on the ducts so as to reduce vibrations and to handle the insulation weight as all ducts will be both thermally and acoustically insulated. However it may be noted that the existing ducting only shall be used for the recording theatre as much as possible and the quantity given below is for the additional quantity which will be consumed at site as and only if required - 24G G.I Sheet (Upto 750mm) |
| 571 | SITC of Rectangle duct with necessary fittings, following SMACNA standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the consultant / client approval as and when required by clientconsultant. All ductings shall be suitably supported with necessary stiffeners provided on the ducts so as to reduce vibrations and to handle the insulation weight as all ducts will be both thermally and acoustically insulated. However it may be noted that the existing ducting only shall be used for the recording theatre as much as possible and the quantity given below is for the additional quantity which will be consumed at site as and only if required - 22G G.I Sheet (from 751 - 1500 mm) |
| 572 | SITC of Rectangle duct with necessary fittings, following SMACNA standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only.The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the consultant / client approval as and when required by clientconsultant. All ductings shall be suitably supported with necessary stiffeners provided on the ducts so as to reduce vibrations and to handle the insulation weight as all ducts will be both thermally and acoustically insulated. However it may be noted that the existing ducting only shall be used for the recording theatre as much as possible and the quantity given below is for the additional quantity which will be consumed at site as and only if required - 20G G.I Sheet (From 1501 - 2250mm) |
| 573 | SITC of Canvas (Fire retardant) along with Damper for supply air for all the units Size - To suit |
| 574 | SITC of VCD (Volume Control Damper)- with Multi Opposed Blade type & frame shall be with Galvanized Iron with min thickness of 18 gauge of frame and min 20 G thick blade shall be used. |
| 575 | SITC of Fresh air damper with pre filter to suit |
| 576 | SITC of Fire Damper with Fusible link to suit the return air (Fire dampers shall be with at least 1.5 hours fire rating. Damper blades shall be one piece folded construction manufactured from high strength galvanized steel Opposed blade type. Damper frames shall be of 18 gauge GI and the blades of min 20 gauge GI). |
| 577 | The supply and fixingreturn air grills / diffusers shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars. The grills / diffusers selected shall have a low NC of around 25. In case of diff size of grills / diffusers used then the same shall be considered in sq mtr value to the nearest thickness / sizes. Diffuser colour shall be decided by client / Architect and vendor has to ensure that the requisite colour of grill is supplied without any additional cost / i.e. cost of spray painting / coating to be covered -Supply Air Diffuser / Grill with Damper |
| 578 | The supply and fixing return air grills / diffusers shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars. The grills / diffusers selected shall have a low NC of around 25. In case of diff size of grills / diffusers used then the same shall be considered in sq mtr value to the nearest thickness / sizes. Diffuser colour shall be decided by client / Architect and vendor has to ensure that the requisite colour of grill is supplied without any additional cost / i.e. cost of spray painting / coating to be covered in theprice - RA Grill / Diffuser |
| 579 | Supply & fixing of thermal insulation with min 25 mm thick closed cell anti microbial nitrile rubber for the additional new ducts if any provided for Recording theatre along with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum,Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided. |
| 580 | Supply & fixing of thermal insulation with min 50 mm thick Thermocol with wire mesh wrapped and cement plastering done for the supply air / Return air ducting exposed to Atmosphere |
| 581 | Supply & fixing of acoustic insulation for the new additional ducts if any provided for the recording Theatre with Minimum 20 mm thick or as required open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type. |
| 582 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc - Unloading, leading, positioning 3.0 TRFour way cassette type IDU for (Equipment Room G Flr) |
| 583 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc - Unloading, leading, positioning 3.0 TR Four way cassette type IDU for (Office Room - G Flr) |
| 584 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc- Unloading, leading, positioning 4 TRFour way cassette type IDU for (Entrance LobbyG Flr) |
| 585 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc - Unloading, leading, positioning 4 TRFour way cassette type IDU for (5.1 Pre Mix Suite G Flr) |
| 586 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc - Unloading, leading, positioning 2 TRFour way cassette type IDU for (Discussion Room G Flr) |
| 587 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc - Unloading, leading, positioning 3 TRFour way cassette type IDU for (Atmos Pre Mix Suite G Flr) |
| 588 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc -Unloading, leading, positioning 3 TRFour way cassette type IDU for (Waiting Lounge G Flr) |
| 589 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc -Unloading, leading, positioning 3 TRFour way cassette type IDU for (Stereo Track Laying G Flr) |
| 590 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc -Unloading, leading, positioning 1.5 TRHi wall Mount type IDU for (Console G Flr) |
| 591 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc - Unloading, leading, positioning 2.0 TRHi wall Mount type IDU for (UPS Room G Flr) |
| 592 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc - Unloading, leading, positioning 2 TRFour way cassette type IDU for (Waiting Lounge I FLr) |
| 593 | SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc - Unloading, leading, positioning 1.5 TRHi wall Mount type IDU for (Staff Rest Room I flr) |
| 594 | SITC,Unloading, leading, positioning18 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit of 18 HP X 2 - Totalling to 36 HP) withcompressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc to be considered. (Basement). Unit with lower power consumption at full load / Part load will be preferred. All compressors shall be of full inverter type. |
| 595 | SITC of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF |
| 596 | SITCof Pipe Line Size -5/8\" - RECORDING THEATRE (13 Indoor with Single Outdoor Unit of 18 TR X 2 Combined Circuit Totalling to 36 HP - VRF Unit) - SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc |
| 597 | SITCof Pipe Line Size -3/8\" - RECORDING THEATRE (13 Indoor with Single Outdoor Unit of 18 TR X 2 Combined Circuit Totalling to 36 HP - VRF Unit) - SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc |
| 598 | SITCof Pipe Line Size -1/2\" -RECORDING THEATRE (13 Indoor with Single Outdoor Unit of 18 TR X 2 Combined Circuit Totalling to 36 HP - VRF Unit) - SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc |
| 599 | SITCof Pipe Line Size -1/4\" - RECORDING THEATRE (13 Indoor with Single Outdoor Unit of 18 TR X 2 Combined Circuit Totalling to 36 HP - VRF Unit) - SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc |
| 600 | SITCof Pipe Line Size -3/4\" - RECORDING THEATRE (13 Indoor with Single Outdoor Unit of 18 TR X 2 Combined Circuit Totalling to 36 HP - VRF Unit) - SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc |
| 601 | SITCof Pipe Line Size -11/8\" -RECORDING THEATRE (13 Indoor with Single Outdoor Unit of 18 TR X 2 Combined Circuit Totalling to 36 HP - VRF Unit) - SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc |
| 602 | SITCof Pipe Line Size -1 3/8\" - RECORDING THEATRE (13 Indoor with Single Outdoor Unit of 18 TR X 2 Combined Circuit Totalling to 36 HP - VRF Unit) - SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc |
| 603 | SITCof Pipe Line Size -7/8\" - RECORDING THEATRE (13 Indoor with Single Outdoor Unit of 18 TR X 2 Combined Circuit Totalling to 36 HP - VRF Unit) - SITC of Cassette Type IDU / Hi wall Mount Unit as required. Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc |
| 604 | SITC ofSuction Line -7/8\" - Unit 1- RECORDING THEATRE AHU with CONDENSING UNITS |
| 605 | SITC of Liquid Line - 1 1/8\" - Unit 1 -RECORDING THEATRE AHU with CONDENSING UNITS |
| 606 | SITC of - Suction Line -7/8\" - Unit 2 - RECORDING THEATRE AHU with CONDENSING UNITS |
| 607 | SITC of Liquid Line - 1 1/8\" - Unit 2-RECORDING THEATRE AHU with CONDENSING UNITS |
| 608 | SITC of Refrigerant Gas - VRF |
| 609 | SITC of Refrigerant Gas - AHU With Condensing Unit |
| 610 | SITCof condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of sizefrom the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber or as required to avoid sweating. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site |
| 611 | Supply of Remote control for each units |
| 612 | Supply and laying of Refnet Joints |
| 613 | SITC , Unloading, leading, positioning of following Split Air Conditioner with rotary compressor.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered in the unit price. Communication cable between IDU to ODU shall be considered by the bidder and the cost shall be included in this price quoted- 2 TR High Wall Mount Units along with Remote Control for Projection Room |
| 614 | SITC , Unloading, leading, positioning of following Split Air Conditioner with rotary compressor.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered in the unit price. Communication cable between IDU to ODU shall be considered by the bidder and the cost shall be included in this price quoted - 2 TR High Wall Mount Units along with Remote Control for UPS Room |
| 615 | SITC , Unloading, leading, positioning of following Split Air Conditioner with rotary compressor.(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered in the unit price. Communication cable between IDU to ODU shall be considered by the bidder and the cost shall be included in this price quoted - 4 TR Cassette Type with Inverter Compressor for Dubbing Room |
| 616 | Supply and Laying of Copper Pipe (Both Suction and Liquid line to be considered for costing) additionally required for the units along with insulation as per piping specs . Unit 1 (Projection Room) |
| 617 | Supply and fixing Copper Pipe (Both Suction and Liquid line to be considered for costing) additionally required for the units along with insulation as per piping specs- Unit 2 (Projection Room) |
| 618 | Supply and fixing Copper Pipe (Both Suction and Liquid line to be considered for costing) additionally required for the units along with insulation as per piping specs -Unit 1 - UPS room |
| 619 | Supply and fixing Copper Pipe (Both Suction and Liquid line to be considered for costing) additionally required for the units along with insulation as per piping specs- Unit 1 - Dubbing RoomCassetter Type |
| 620 | Providing and installation Drain Pump for Hi wall Mount VRF Unit or as required |
| 621 | Supply and installation of FRESH AIR REQUIREMENT FOR VENTILATION COMPLETE INCLUDING CONNECTION TO VRF IDU AS DESCRIBED BELOW - Fresh Air Filter |
| 622 | SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc as required |
| 623 | SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thickness of min 25 mm nitrile rubber / connecting to each units etc as required |
| 624 | SITC of Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (500 cfm) - Store room |
| 625 | SITCAir Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (400 Cfm) - Store Room |
| 626 | Supply and fixing of Rubber pads for out door units |
| 627 | Supply and erection of MS Structural support / Channelsfor IDU s / ODU Sto suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc to be provided |
| 628 | Miscellenoeous chargeslike, required civil works etcfor completing HVAC (demolishing & finishing the damaged portion) |
| 629 | Part 6.Internal Electrical , Fire alarm & Elevator works |
| 630 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 631 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 632 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 633 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 634 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 635 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 636 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 637 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 638 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 639 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 640 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 641 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm |
| 642 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep |
| 643 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 644 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 645 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet |
| 646 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 1 run of Cable |
| 647 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door |
| 648 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 649 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 650 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 651 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 652 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 653 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 654 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 655 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 656 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 657 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 658 | Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 amps \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 659 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 660 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 661 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 662 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 663 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 664 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 665 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 666 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 667 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 668 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 669 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 670 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 671 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 672 | Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 673 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½x 35 Sq.mm. AYFY, XLPE, Al, UGcable |
| 674 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 Sq.mm. AYFY, XLPE, Al, UGcable |
| 675 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 25 Sq.mm. AYFY, XLPE, Al, UGcable |
| 676 | Supplying, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection .) having high performance, regulating programmable type, suitable for connected load up to 10 Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 677 | Supplying, installation, testing and commissioning of Microwave technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load up to 10 Amp, for mounting height up to 2.6 mtr and for 5m x 20 m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 678 | Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc. complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc. as required. (Group B/ RoHS compliant modular accessories). Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Medium point |
| 679 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades and resistance type regulator working on 230V/240V single phase A/C |
| 680 | Supply and installation of sheet steel, phosphatized and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43) |
| 681 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - three phase double cover (IP 42/43 |
| 682 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 683 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 10 sq mm |
| 684 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 35 Sq.mm. AYFY, XLPE, Al, UGcable |
| 685 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4Cx 16 Sq.mm. AYFY, XLPE, Al, UGcable |
| 686 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4Cx 25 Sq.mm. AYFY, XLPE, Al, UGcable |
| 687 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 35 Sq.mm. AYFY, XLPE, Al, UGcable |
| 688 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4Cx 16 Sq.mm. AYFY, XLPE, Al, UGcable |
| 689 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4Cx 25 Sq.mm. AYFY, XLPE, Al, UGcable |
| 690 | Wiring for group controlled (Looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.,) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, and earthing the points with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable for looping as required. |
| 691 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door |
| 692 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch |
| 693 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 694 | Supplying and fixing following modular base & cover plate on existing modular metal boxes etc., as required 3 module |
| 695 | Supplying and fixing following modular base & cover plate on existing modular metal boxes etc., as required 4 module |
| 696 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 697 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 698 | Steel work in built up tubular (round, square, hallow tub etc.,) trusses etc., including cutting, hoisting, fixing and applying a primer coat of approved steel primer including welding and bolting with special shaped washers etc., complete hot finish welded type tubes |
| 699 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 700 | Supplying and fixing of modular Socket including connectionsetc. as required. Data socket outlet |
| 701 | Supplying and fixing of 1M / 2M Surface plate and 2 M Surface boxincluding connectionsetc. as required. Data socket / telephone outlet |
| 702 | Supplying and fixing of 2M Surface plate and 2 M Metal boxincluding connectionsetc. as requiredData socket outlet |
| 703 | Supply, erection, testing and commissioning of 18 W LED down lighter fittingwith cool day light made out of CRCA powder coated body,poly carbonate diffuser, glare free light, suitable for recessed / surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. |
| 704 | Supply, erection, testing and commissioning of24 W LED down lighter fitting with cool day light, made out of CRCA powder coated body, poly carbonate diffuser, glare free light, suitable for recessed / surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. |
| 705 | Supply, erection, testing and commissioning of36 W LED down lighter fitting with cool day light, made out of CRCA powder coated body,poly carbonate diffuser, glare free light, suitable for recessed / surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. |
| 706 | Supply, erection, testing and commissioning of10 W LED bulk head fitting with cool day light suitable for surface mounting, made out of CRCA powder coated body, poly carbonate diffuser, Suitable for fitting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. |
| 707 | Supply, erection, testing and commissioning of150 W LED flood light fitting with cool day light suitable for surface / recessed mounting, made out of CRCA powder coated body, poly carbonate diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. |
| 708 | Supply, erection, testing and commissioning of250 W LED Flood light fitting with cool day light suitable for surface / recessed mounting, made outCRCA powder coated body,poly carbonate diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive. |
| 709 | Supply, erection, testing and commissioning of3 W LED foot light with cool day light suitable for surface mounting, made out of CRCA powder coated body,poly carbonate diffuser, Suitable for fitting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. |
| 710 | Supply, erection, testing and commissioning of11 W LED entry / exit light fitting with cool day light, made out of CRCA powder coated body, poly carbonate diffuser, glare free light, suitable for recessed / surface mounting test switch, electronic drivers, day light colour LED inter connecting wiring etc.,including accessories all inclusive. |
| 711 | Supply and providing 300 mm (12\") sweep (light duty) 1400 RPM, AC exhaust fan complete in the provided cut-out including interconnection wire. |
| 712 | Supply and providing 450 mm (18\") sweep (light duty) 1400 RPM, AC exhaust fan complete in the provided cut-out including interconnection wire. |
| 713 | Supply, erection, testing and commissioning of230 V AC buzzer, 1 module suitable switch board mounting. |
| 714 | Supply, erection, testing and commissioning of 5 W LED type foot lamp suitable for GI module back box. |
| 715 | Supply, installation testing and commissioning of Online 1.0 KVA UPS with 30 minutes SMF battery backup, with 230V, 1 phase input, 230 V single phase output |
| 716 | Supply, installation testing and commissioning of Online 3.0 KVA UPS with 30 minutes SMF battery backup, with 230V, single phase input, 230 V single phase output |
| 717 | Supply, installation testing and commissioning of Online 5.0 KVA UPS with 30 minutes SMF battery backup, with 230V, single phase input, 230 V single phase output |
| 718 | Supply, installation testing and commissioning of Online 10 KVA UPS with 30 minutes SMF battery backup, with 415V, 3 phase input, 230 V single phase output |
| 719 | Supply, erection, testing and commissioning of10 W LED mirror light fitting made out of CRCA powder coated body,poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting electronic drivers, day light / warm white colour LED inter connecting wiring etc.,including accessories all inclusive. |
| 720 | Supply, erection, testing and commissioning of60 W LED (Per 5 Meter) professional LED strip light IP 21 with cool day light, including suitable fixing, electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. |
| 721 | Supply, erection, testing and commissioning of1 W LED spot LED light with cool day light, including suitable fixing, electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. |
| 722 | Dismantling of existing electrical wiring, light fitting, ceiling fan, AC units, power sockets, Dataand telephone sockets and associated wiring and handing overthe same to stores etc. all incisive. Bidder to quote amount based on theirown assessment during site visit prior to submission of Bid.(Drishya & Large shooting floor) |
| 723 | Dismantling of existing electrical wiring, light fitting, ceiling fan, AC units, power sockets, Dataand telephone sockets and associated wiring and handing overthe same to stores etc. all incisive. Bidder to quote amount based on theirown assessment during site visit prior to submission of Bid.(Mini shooting floor, Medium shooting floor& Office building) |
| 724 | Supply, installation testing and commissioning ofWall fan with 600 mm (24\") Sweep, Heavy duty oscillation type propeller fan available with impeller consisting of 3 blades in pedestal & bracket type (wall & column mounted). |
| 725 | Supply, installation testing and commissioning of Online 2.0 KVA UPS with 30 minutes SMF battery backup, with 230V, single phase input, 230 V single phase output |
| 726 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 727 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/230V single phase A/C |
| 728 | Dismantling of existing electrical wiring, light fitting, ceiling fan, AC units, power sockets, Dataand telephone sockets and associated wiring and handing overthe same to stores etc all incisive.Bidder to quote amount based on theirown assessment during site visit prior to submission of Bid. |
| 729 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analogue/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel |
| 730 | Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 731 | Supplying, installation, testing & commissioning of intelligent analogue addressable photothermal detector complete with mounting base complete as required. |
| 732 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc. as required. |
| 733 | Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. |
| 734 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 735 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 736 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or separate) complete with emitter and receiver including connections with remote test features etc. complete as required. |
| 737 | Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. |
| 738 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 739 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 740 | Supplying & laying of 2x1.5 sqmm fire alarm unarmoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required - (a) 2c x 1.5 sq. mm unarmoured cable. |
| 741 | Supplying, erecting, testing and commissioning of machine room less passenger Elevator having 10 passengers capacity of 680 Kgs, rated speed 1.0 mtr./sec., for GF, plus 1 upper floor, 2 openings, 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding, simplex full collective with/with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, stainless steel panels with hairline finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, stainless steel hairline finish sliding doors, painted frame with down light false ceiling, Stainless Steel mirror finish hand rails, granite flooring of client choice, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman\"s switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door. Car Entrance:- Clear opening 900 mm wide x 2100mm high etc., inclusive of all tax and duties |
| 742 | Part 7.Common Infra - External electrical,Street lighting & Power socket |
| 743 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral |
| 744 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 745 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 746 | Supply, installation, testing commissioning of 415 V, three phase incoming and 230 V single phase outgoing portable power socket suitable for outdoor operation with IP 67 rating, with following Excluding MCB\"s: (Type - I)Provision for Incommer : 63 Amps 4 pole MCB - 1 no.Provision for outgoing :32 A SP MCB - 2 nos. 16 A SP MCB - 4 nos.Industrial power socket : 32 A 3 pin socket with plug - 2 nos.16 A 3 pin socket with plug- 4 nos.The enclosure shall be made out of poly carbonate suitable for outdoor operation with necessary mounting arrangement |
| 747 | Supply, installation, testing commissioning of 415 V, three phase incoming and 230 V single phase outgoing portable power socket suitable for outdoor operation with IP 67 rating, with following Excluding MCB\"s:(Type - II )Provision for Incommer : 63 Amps 4 pole MCB - 1 no.Provision for outgoing :16 A SP MCB - 4 nos.Industrial power socket : 16 A 3 pin socket with plug- 4 nos.The enclosure shall be made out of poly carbonate suitable for outdoor operation with necessary mounting arrangement |
| 748 | Supply, testing and commissioning of PVC Insulated and PVC Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial unarmoured Cables for Voltage Grade 1100 Volts as per IS: 694:20104 core x 16 sq.mm cable |
| 749 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 750 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 751 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 752 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 Sq.mm. AYFY, XLPE, Al, UGcable |
| 753 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 16 sq mm |
| 754 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required - Above 6.5 metre and up to 8.0 metre Each |
| 755 | Design, manufacture, supply, erection, testing and commissioning of 415 V street lighting feeder pillar box suitable for outdoor installation, made up of CRCA sheet steel of thickness not less than 2 mm with a weather proof canopy of top, double door construction, IP 55 protection, anti corrosive chemical resistant paint with 1no. 125 A TPN MCCB with 16 kA breaking capacity in the incoming and 8 nos 25 A,TPN contactor 10nos. 25 A TPN MCCB, 24 nos, 10A SP MCB as outgoing, automatic dawn and dusk with cyclic timer control for street light outgoing and adequate plate to terminate suitable cable as incomer and suitable cable as outgoing. energy saver for automatic switching ON/OFF as per pre-sets time cycle, digital multifunctional meter with RS485 port and suitable CT etc., including concrete pedestal and associated civil works. |
| 756 | Design, manufacture, supply of 7.50 meter swaged street light pole (410-SP-6)with 1.50 m single arm including transportation to site. |
| 757 | Supply and fixing of following LED street light fitting with cool day light, made out of Pressure die cast aluminium body, separate compartment for LED, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams as required including accessories all inclusive - 90 W LED street light fitting |
| 758 | Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. 1250 amps 50 KA SC for 1 sec |
| 759 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 760 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 761 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 762 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 763 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 764 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 765 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 766 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 767 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 768 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 769 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 770 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 771 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 772 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 773 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.Above 120 sq. mm and up to 400 sq. mm |
| 774 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½x 25 Sq.mm. AYFY, XLPE, Al, UGcable |
| 775 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½x 35 Sq.mm. AYFY, XLPE, Al, UGcable |
| 776 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½x 70 Sq.mm. AYFY, XLPE, Al, UGcable |
| 777 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½x 95 Sq.mm. AYFY, XLPE, Al, UGcable |
| 778 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½x 120 Sq.mm. AYFY, XLPE, Al, UGcable |
| 779 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½x 240 Sq.mm. AYFY, XLPE, Al, UGcable |
| 780 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½x 300 Sq.mm. AYFY, XLPE, Al, UGcable |
| 781 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 10 Sq.mm. AYFY, XLPE, Al, UGcable |
| 782 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 Sq.mm. AYFY, XLPE, Al, UGcable |
| 783 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sqmmXLPE Al. Ar. cable |
| 784 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sqmmXLPE Al. Ar. cable |
| 785 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 25 Sq.mm. AYFY, XLPE, Al, UGcable |
| 786 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 35 Sq.mm. AYFY, XLPE, Al, UGcable |
| 787 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 70 Sq.mm. AYFY, XLPE, Al, UGcable |
| 788 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 95 Sq.mm. AYFY, XLPE, Al, UGcable |
| 789 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 120 Sq.mm. AYFY, XLPE, Al, UGcable |
| 790 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 185 Sq.mm. AYFY, XLPE, Al, UGcable |
| 791 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 240 Sq.mm. AYFY, XLPE, Al, UGcable |
| 792 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3½Cx 300 Sq.mm. AYFY, XLPE, Al, UGcable |
| 793 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3½Cx 25 Sq.mm. AYFY, XLPE, Al, UGcable |
| 794 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3½Cx 35 Sq.mm. AYFY, XLPE, Al, UGcable |
| 795 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3½Cx 70 Sq.mm. AYFY, XLPE, Al, UGcable |
| 796 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3½Cx 95 Sq.mm. AYFY, XLPE, Al, UGcable |
| 797 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3½Cx 120 Sq.mm. AYFY, XLPE, Al, UGcable |
| 798 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3½Cx 185 Sq.mm. AYFY, XLPE, Al, UGcable |
| 799 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3½Cx 240 Sq.mm. AYFY, XLPE, Al, UGcable |
| 800 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3½Cx 300 Sq.mm. AYFY, XLPE, Al, UGcable |
| 801 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 25 Sq.mm. AYFY, XLPE, Al, UGcable |
| 802 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 35 Sq.mm. AYFY, XLPE, Al, UGcable |
| 803 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 70 Sq.mm. AYFY, XLPE, Al, UGcable |
| 804 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 95 Sq.mm. AYFY, XLPE, Al, UGcable |
| 805 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 120 Sq.mm. AYFY, XLPE, Al, UGcable |
| 806 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 185 Sq.mm. AYFY, XLPE, Al, UGcable |
| 807 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 240 Sq.mm. AYFY, XLPE, Al, UGcable |
| 808 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3½Cx 300 Sq.mm. AYFY, XLPE, Al, UGcable |
| 809 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4Cx 10 Sq.mm. AYFY, XLPE, Al, UGcable |
| 810 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4Cx 16 Sq.mm. AYFY, XLPE, Al, UGcable |
| 811 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 10 sq mm |
| 812 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 16 sq mm |
| 813 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm |
| 814 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm |
| 815 | 11 kV HT RMU Panel Supply and Installation of Data Acquisition compatible, Extensible, add-on type Ring Main Unit with VCB (Single Switch T-Extension) with motors for remote switching and DA CompatibleDesign, Engineering, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at site, erection, installation, testing & commissioning of 11 kV HT switchgear with all accessories and suitable for installationin three phase, three wire,11 kV, 50 Hz, A.C. distribution network. complete with all accessorieserected in the provided foundation complete as per specification and as directed by engineer in charge at site. The RMU shall be complying to KSEB specification. Outdoor type, 11 kV Extensible Ring Main unit (RMU), with 1 No. Vacuum Circuit Breaker in tee OFF the Vacuum Circuit Breaker (VCB) feeder shall Comprise of1 No. 11 kV, 630A, 18.0 kA, for 3 sec, manual operated VCB 1 No. Common Items, Earth Switch & Accessories for each RMU1 set Operating Handle (Supplied Loose with RMU)The panel shall be suitable for terminating 1 R of 3C x 300 Sq.mm XLPE 11kV (E) cable |
| 816 | Outdoor transformersSupply, erection, testing and commissioning of 11 / 0.433 kV, 800 kVA, copper wound, outdoor distribution transformer, ONAN, DYn11,with Off load tap changer range from +5% to -10% in steps of 2.5% with 6 steps / 7 positions, complete with first oil filled, with suitable cable box for HT side termination and Bus duct in LT side termination complying to IS 2026, including transportation, unloading at site, all control cables between transformer Marshalling box to MV Panel,in the constructed foundation of adequate depth for transformer plinth of height 450 mm above FGL, mounting channeling etc., all inclusive.Specification should meet IS 118o transformer losses level -3. |
| 817 | Supply, erection, testing, commissioning of 400 KVA, 415 V, 3 phase, 50 Hz, DG Set suitable for synchronization with diesel engine at 1500 RPM coupled with alternator rated at 400 KVA, 415 V, 0.8 PF mounted on a channel Iron base frame, fuel tank of adequate capacity, starting batteries with leads, AMF panel, hospital type silencer, with acoustic enclosure , control panel, inter connecting control cable, cable end termination, including lubrication system, cooling system, all inclusive. DG set should comply with central pollution control board (CPCB) norms as per the latest environment (protection) rules, |
| 818 | Supply, erection, testing, commissioning of auto synchronization panel suitable for 2nos x 400 KVA, 415 V, 3 phase, 50 Hz, DG Setwith CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification / as per local norms, comprising of the following major switchgear/ devices / components and form-III B form of construction with incomer of 2 nos 630 Amps, 50 kA, 4 pole microprocessor based ACB,andoutgoing of 1 no. 1250 Amps, 50 kA, 4 pole microprocessor based ACB, auto synchronizing relay, Microprocessor based DG set protection relay with associated control and protection CTof appropriate burden, electronic energy meter, auto / manual selection for synchronizing. |
| 819 | MV panel Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction as per SLD.Protection27, 50, 51, 50N, 51G, 81, 64R & 86 for Transformer Incomer Feeder. Including necessary CT for 51G27, 50, 51, 50N, 51G, 81 & 86 for Diesel Generator Incomer Feeder. Including necessary CT for 51GMetering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication, Digital energy meter with necessary CTs Power pack with battery backup for ACB operation.AMF relay including auto / manual selection with necessaryinterconnection and electrical interlock.IndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments.Busbar 1250A, 50 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Transformer incomer & Bus coupler1 No. each of 1250A, FP EDO, ACB, 50 kA with Microprocessor based O/C, S/C & E/F releases with electrical interlock with DG incomer & Bus CouplerDG incomer1 No. each of 1250A, FP EDO, ACB, 50 kA with Microprocessor based O/C, S/C & E/F releases with electrical interlock with DG setincomer & Bus CouplerOutgoing:630 A, TPN MCCB 50 kA, - 3 Nos.400 A, TPN MCCB 50 kA, - 3 Nos.250 A, TPN MCCB 36 kA, - 10 Nos.250 A, TPN Isolator 36 kA, - 1 Nos. for Fire pump125 A, TPN MCCB 25 kA, - 8 Nos. |
| 820 | Sub switch board(SSB) - AT Drishya buildingDesign, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP,Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing:63 A, TPN MCCB 25 kA, - 9 Nos.32 A, TPN MCCB 25 kA, - 9 Nos. |
| 821 | Sub switch board - at Recording theatreDesign, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing:63 A, TPN MCCB 25 kA, - 8 Nos.32 A, TPN MCCB 25 kA, - 2 Nos. |
| 822 | Sub switch board-AT Main shooting floor Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete, AMF relay with necessary control wiring arrangement as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP.Busbar 400A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer - 1400 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomerEDG Incomer - 2400 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with incomer-1Power change over Contactor 400 Amps 4 pole change over contact for EB & DG incomer with necessary power pack for AMF relay.Outgoing:125 A, TPN MCCB 25 kA, - 6 Nos.63 A, TPN MCCB 25 kA, - 10 Nos.32 A, TPN MCCB 25 kA, - 2 Nos. |
| 823 | Sub switch board- atDI building Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing:63 A, TPN MCCB 25 kA, - 8 Nos.32 A, TPN MCCB 25 kA, - 2 Nos. |
| 824 | Sub switch board-at Mini shooting floor Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing:63 A, TPN MCCB 25 kA, - 8 Nos.32 A, TPN MCCB 25 kA, - 2 Nos. |
| 825 | Sub switch board- at Office BUILDINGDesign, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing:63 A, TPN MCCB 25 kA, - 8 Nos.32 A, TPN MCCB 25 kA, - 2 Nos. |
| 826 | Sub switch board- at Property store Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments.Busbar 125A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer125 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomerOutgoing:63 A, TPN MCCB 25 kA, - 6 Nos. |
| 827 | Sub switch board- at L Shaped studioDesign, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments.Busbar 125A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer125 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomerOutgoing:63 A, TPN MCCB 25 kA, - 6 Nos. |
| 828 | Sub switch board- at Medium shooting floor Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments.Busbar 125A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer125 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomerOutgoing:63 A, TPN MCCB 25 kA, - 6 Nos. |
| 829 | Utility PanelDesign, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction.Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communicationIndicationsCluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments.Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer250A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomerOutgoing:125 A, TPN MCCB 25 kA, - 4 Nos.63 A, TPN MCCB 25 kA, - 6Nos.32 A, TPN MCCB 50 kA, - 4 Nos. |
| 830 | 270 KVAr APFC capacitor panel - at substationSupply, installation, testing and commissioning of 270 KVAr Automatic power factor correction panel (APFC) with 10 steps of capacitor switching with 7 % de-tuned filter, cubicle type, free standing, powder coated, 14 G CRCA sheet steelenclosed separate compartment for each capacitor, front operated, indoor type dust & vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 10 stage Digital Automatic power factor correction controller, Auto / Manual selector switch, cluster LED typeindicators, in the incomer with 630 A, TPN MCCB 50 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases,complete with 480 Volts MPP type Power capacitors, with 3 Nos. 50 KVAr,4 Nos. 25 KVAr,1 no. 10 KVAr and 2 nos. 5 KVAR capacitor banks in delta connection, capacitor duty contactors, MCCB’s, timer, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth & painting, Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., all inclusive. |
| 831 | Installation of existing 70 KVAr APFC capacitor panel at Drishya buildingInstallation, testing and commissioning of existing 70 KVAr Automatic power factor correction panel (APFC) including dismantling and re erection of the panel including all necessary accessories and hardware etc., as required all inclusive. |
| 832 | Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).12 core 2.5 sqmmXLPE Cu. Ar. cable. |
| 833 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 x 4 Sq.mm. AYFY, XLPE, Al, UGcable |
| 834 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 x 4 Sq.mm. AYFY, XLPE, Al, UGcable |
| 835 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.12 core 2.5 sqmmXLPE Al. Ar. cable |
| 836 | Supply of one number PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes11kV, 3 core 300 sqmmXLPE Al. Ar. cable |
| 837 | Supplying and laying 50 mm X 6 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 838 | Supply and Provision of Fire Sealant at cable penetration Area |
| 839 | 11kV Rubber Hand Gloves |
| 840 | 11 kV/ 415V Caution Board |
| 841 | Shock Treatment chart as per IE Rules (local language must) |
| 842 | Supply, erecting and connecting 4 No. 10 Ltr. capacity Fire Bucket painted with Red oxide outside and White inside with handle at the bottom in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with Red paint. |
| 843 | Supply and fising of First Aid Box. |
| 844 | 22kV grade synthetic insulation mat,1000 mm x 2.5 mm thickness, compliant to IS with amendment 1 & 2, Class A, CPRI type test certificate required |
| 845 | 1.1 kV grade synthetic insulation mat,1000 mm x 2 mm thickness, compliant to IS with amendment 1 & 2, Class A, CPRI type test certificate required |
| 846 | Supplying and fixing cable route marker made out of precast cement block complying to electricity board regulations including excavation and fixing the same with PCC concrete in ground as required. |
| 847 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 848 | Part 8.Common Infra - Lift |
| 849 | Supplying, erecting, testingand commissioning of machine room less passenger Elevator having 10 passengers capacity of 680 Kgs, ratedspeed 1.0 mtr./sec., forGF, plus 1 upper floor, 2 openings, 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding,simplex full collective with/with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, stainless steel panels with hairline finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, stainless steel hairline finish sliding doors, painted frame with down light false ceiling, Stainless Steel mirror finish hand rails, granite flooring of client choice, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman\"s switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door. Car Entrance:- Clearopening900 mm wide x 2100mm high etc., inclusive of all tax and duties |
| 850 | Supplying, erecting, testingand commissioning of machine room less Goods lift having 1000 kgs capacity, ratedspeed 0.5 mtr./sec., forGF, plus 1 upper floor, 2 openings, 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding,simplex full collective with/with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, Mild steel Power coated finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, Mild steel Power coated sliding doors, painted frame with down light false ceiling, Mild steel Power coated hand rails, chequered plate flooring, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman\"s switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door. Car Entrance:- Clearopening900 mm wide x 2100mm high etc., inclusive of all tax and duties |
| 851 | Part 9.Common Infra works - Sump,Pumproom,Septic tanks..etc |
| 852 | Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 853 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 854 | Treatment of soil underfloors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (Excluding the cost of Chemical emulsion) |
| 855 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. |
| 856 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock |
| 857 | Excavating trenches of required width for pipes, etc. includingexcavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then refilling the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes,exceeding 80 mm dia, but not exceeding 300 mm dia. |
| 858 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 859 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. Ordinary or hard rock |
| 860 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 861 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 862 | Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 863 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 864 | Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Note : 1) Excess /less cement used than specified in this item is payable / recoverable separately. M-15 grade plain cement concrete (cement content considered @ 220 kg/cum) |
| 865 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 866 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete |
| 867 | Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 868 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform |
| 869 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 870 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Columns, Pillars, Piers, Abutments, Posts and Struts |
| 871 | Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 872 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 873 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 |
| 874 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). - All works up to plinth level |
| 875 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level up to floor V level |
| 876 | Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cementcontent considered in M-30 is @ 340 kg/cum) |
| 877 | Add/less (\"+\" or \"-\")for using extra or less cement in the items of design mix over and above the specified cement content therein. |
| 878 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5in plinth Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 879 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) - 230mm thick |
| 880 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 230mm thick |
| 881 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 882 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades, of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 883 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 884 | Providing and fixing M.S. grills of required pattern in frames of windows etc. With M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 885 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) |
| 886 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing &direction of Engineer-in-Charge. The rate including Single / double glass panes and silicon sealant .( The thickness of glass shall be 6mm) |
| 887 | Providing and fixing of Wooden Finish UPVC (Unplasticized Poly Vinyl Chloride) three track Sliding Window using 60mm x 37mm outer frame with door Sash of 39 x 75mm frame and all sections shall reinforced with galvanised steel. The Glazed shutters are fixed with 6mm clear float glass fixedwith EPDM gasket and co extruded beadings with Espag locking system. The door frame is fixed to the walls using fasteners and to be sealed as external and internal surfaces using weather resistant Silicon sealant of approved make complete as per drawing. |
| 888 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 889 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with rackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 890 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 891 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 892 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer\"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 893 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades,laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 894 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 895 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 896 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 897 | 20 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 898 | Ceiling Plastering with CM 1:3, 6mm thick |
| 899 | Rough cast plaster up to 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. - Ordinary cement finish using ordinary cement |
| 900 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 901 | Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing |
| 902 | Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Flush/ Ruled pointing |
| 903 | Finishing walls with water proofing cement paint of required shade: New work ( Two or more coats applied @3.84kg/10sqm) |
| 904 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
| 905 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coat for new work - For Ceiling & Internal walls |
| 906 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. - External walls |
| 907 | Preparing the surface, providingandapplyingtwo coatsofSynthetic Enamel paintofapproved brand, quality, color etc. as per IS 2932 : 2003 after thoroughly sand papering the surfaces,removingthedust,dirt,repairing&fillingdents, holes,cracksetc.overtwo coatsofapproved primer as per IS 2074 and one coat of paste filler towall surfaces including cost oflabour,materials, scaffolding, transportation, loading and unloading, tools & plants, all other incidental charges,etc. complete as per drawings, specificationsat the following levels and as per the instructions of Engineer-in-Charge. The total painted thickness shall not be less than 100 microns DFT |
| 908 | Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead. |
| 909 | Dismantling and stacking with in 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of : R.C.C. |
| 910 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 911 | Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I staples on wooden plugs or G.I binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used . |
| 912 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at to[ in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ), and making necessary channel in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With Sewer bricks conforming to IS:4885 - Circular type manhole up to 0.91 m deep |
| 913 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottam and 0.56 m dia at to[ in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ), and making necessary channel in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With Sewer bricks conforming to IS:4885 -Circular type manhole up to 0.91 m to 1.67 m deep |
| 914 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 1.68 m deep with SFRC cover and frame (heavy duty Hd- 20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. ( Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With sewer bricks conforming IS:4885 - Circular type manhole 1.22 m internal dia 1.68 m deep |
| 915 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 1.68 m deep with SFRC cover and frame (heavy duty Hd- 20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. ( Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With sewer bricks conforming IS:4885 - Circular type manhole 1.22 m internal dia deep beyond 1.68 m to 2.29 m |
| 916 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement:4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as per standard design: 2.30 m deep with SFRC cover and frame (heavy duty HD - 20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With sewer bricks conforming IS:4885 - Circular type manhole 1.52 m internal dia2.30 m deep |
| 917 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement:4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as per standard design: 2.30 m deep with SFRC cover and frame (heavy duty HD - 20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With sewer bricks conforming IS:4885 - Circular type manhole 1.52 m internal dia2.31 mto 3.30 m deep |
| 918 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786,having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 919 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality -MD -10-Square shape 560 mm internal dimensions |
| 920 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineering- charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm |
| 921 | Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 922 | Filling with contractor\"s own earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 923 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc. complete. |
| 924 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc. complete |
| 925 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete. |
| 926 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 927 | Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110 mm dia 4 Kg/cm2 |
| 928 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 929 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 930 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : ordinary rock- depth 1.5m to 3.0m - Pipes,exceeding 80 mm dia, but not exceeding 300 mm dia. |
| 931 | Providing drop manhole connection with 160mm dia UPVC pipe,PCC 1:2:4 , UPVC specials , and necessary chamber etc. complete in all respects as per drawingcomplying with standard specifications and as directed by departmental officers. |
| 932 | Supplying and laying the 160mm dia dia uPVC pipes class SN 8, SDR-34, confirming to IS 15328-2003 and relevant specials including packing the joints with rubber /lubricant fixing ,holding wherever necessary and making good of the dismantled portion with necessary connectionsetc., complete in all respects and as per drawing. |
| 933 | Supplying and Laying Mangalore cement concrete tilesover the RCC roof jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cementmortar 1:4 (1 cement: 4 coarse sand). |
| 934 | Providing and fixing of precast R.C.C. post / struts / pillars of mix 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size ) of required size with wooden plugs or 6 mm bar nibs ( Cost is inclusive of steel reinforcement , shuttering as per drawing )wherever required as per direction of Engineer-in-Charge (cost of earth works in excavation, concrete works in foundation to be paid separately) |
| 935 | Filling of the polyurethane bags by mixture of good earth and manure in the ratio of 2:1 (2 part of good earth and 1 part of the cow dung manure) and placing the same of appropriate placeall complete as per direction of the Officer-in-charge. Polyurethane bags size 30 cm dia X 30 cm height |
| 936 | Supplying and stacking at site dump manure from approved source, including carriage up to 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm |
| 937 | Providing mono rail 3 tonne capacity, Height of Lift - 5 metres, Operation: Through pendant push button station,Long travel: 10.2 m using ISMB 250, Motor: A.C.Sq. CAGE S4 duty, F Class, IP 55, Open geared type bearing mounted assembly, pulley,motor arrangements ..etc. completewith all inclusive as directed by engineer - in -charge.Make: Reva Engineering, Avon cranes, W.H. Brady & Co. Ltd., Marris, Index, Safex, JAPS |
| 938 | Providing and Laying Graded metal stone 53mm and belowcomplete as per direction of Engineer-in-Charge |
| 939 | Carting away the excavatedearth/Ordinary rock and depositing the same up to 3 to 5 km with an average lead of 4 km from the site including loading and unloading etc., all complete and as directed by the Engineer in charge |
| 940 | Earthwork excavation & filling the excavated earth in low-lying area etc. complete as directed by the engineer in charge - All kinds of soil |
| 941 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: |
| 942 | Supply, Installation, testing and commissioning of boom barriers comprising of the following :-1. New generation road barrier , Boom length 6 m2. Motor type- 24 V DC 3. Usage - Intensive use4.Protection - IP655.Housing - Galvanized and powder coated with minimum dimension: 1300mm X 330mm X 240mm6.Adjustable opening/closing speed - 4-8 Sec7. Max. Absorbed power - 300 W8.Minimum Torqu - 600Nm9.Inbuilt encoder for safety10.Operating temperature - -20 degree to +55 degree11.Control Panel - To be located horizontally at top portion of the cabinet minimum 915mm above the Barrier foundation for simple and quick maintenance , to be compatible for connecting any access control system including RFID12.Provision for fixing Flashing LED on top of the cabinet13.Max. boom length 6 Mtr.14.Boom should be with Strong round Auminium pipe minimum 100mm dia15. Provision for fixing LED illumination on both side of the boom at middle line. Also with provision of fixingRED reflective adhesive stickers on both side of the boom.16. Suitable for fixing additional brake away system for the boom. Manual Operation needed in case of power failure.17.Provision for connecting Push Button switch for open/close. Provision for connection photoelectric cell, one side with an adapter on the cabinet18.Provision for connecting loop detectors( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 943 | Supply, Installation, testing and commissioning of horizontal centrifugal monobloc pump of capacity 280 LPM and 12 m head (Capacity 2HP pump) each and electric control panel boardwith cyclic timer, dry run protection, required electrical and control wiringand also including supply and fixing the required butterfly valves including the cost for the required length of pipes for header pipes, discharge pipe from pump up to existing OHT including the cost for the required dismantling joints on either side of the pumps, as per manufacturer specifications along with all accessories like common base plate with suction and discharge manifold complete and as directed by the engineer in charge. |
| 944 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 25mm dia |
| 945 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 32mm dia |
| 946 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 40mm dia |
| 947 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 62.5mm dia |
| 948 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 75mm dia |
| 949 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 950 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore |
| 951 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore |
| 952 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore |
| 953 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore |
| 954 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete asper standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 955 | Supplying and fixing of 25mm dia pressure reducing valve of approved quality for reducing the downstream pressure along the water distribution line along with necessary jointing materials, gaskets, bolts, nuts inclusive of dismantling pieces, washers etc. as per direction of Engineer in charge - 25mm dia pressure reducing valve |
| 956 | Constructing thrust block in R.C.C. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 nominal size) for CPVC pipeline along the downstream of OHT and including the base concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) with necessary excavation including required reinforcement, centering and shuttering, strutting, propping etc. and removal of form for the sizes as below as per the drawing and as per direction of Engineer in charge - Thrust block Size - 0.3 m x 0.3 m x 1.0 m (2 Nos each for potable and raw water distribution network) |
| 957 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete - 900mm dia RCC pipe |
| 958 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 100mm dia pipe |
| 959 | Supply, Installation, testing and commissioning of Vertical submersible pump ( 6Hp) of capacity 225 LPMand 54 m head each and electric control panel board with cyclic timer, dry run protection, required electrical and control wiringand also including supply and fixing the required butterfly valves, non return valves, pressure gauge at each pump outlet of 150mm dial, 1/2\" NPTM bottom connection, measuring element 316 SS diaphragm suitable to measure the discharge header pressure & pump discharge line pressure (0 to 10 kg/Sq.cm) etc. including the cost for the required length of pipes for header pipes, discharge pipes for each pump and for common discharge pipes and including the cost for the required dismantling joints on either side of the pumps, as per manufacturer specifications along with all accessories like common base plate with suction and discharge manifold complete and as directed by the engineer in charge. |
| 960 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 100mm dia |
| 961 | Providing and fixing C.I. double acting air valve of approved quality with bolsons, rubber insertions etc. complete: 50 mm dia |
| 962 | Constructing thrust block in R.C.C. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 nominal size) for HDPE pipeline and including the base concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) with necessary excavation including required reinforcement, centering and shuttering, strutting, propping etc. and removal of form for the sizes as below as per the drawing and as per direction of Engineer in charge - Size of 0.3 m x 0.3 m x 1.0 m (Pumping main) |
| 963 | Drilling of Bore wells including transportation from one place to another in all strata for 300 mm dia borewelldirect or reverse rotary rigs, including side packings, disinfections, soil sample tests, water quality test, cost of fuel, labour and drilling and water required for drilling at site including construction of mud pit, 200 dia column pipe (10kg/Sqm) etc. complete as per direction of engineer in charge (For 2 borewell locations) -Drilling of 200mm dia bore up to 100 m depth ending below ground level |
| 964 | Charges for developing the Bore well with air compressor (minimum 8 Hours) till a clear water comes from the bore well without any silt or mud mixes, including the cost required for transportation of the compressor, labour and fuel charges for compressor as directed byEngineer in charge |
| 965 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. - 100mm dia pipe |
| 966 | Supply, installation testing & commissioning of vertical submersible pump for borewell of capacity 280 LPM each pump and 174 m head each (19 HP pump set) along with non return valves, pressure gaugeincluding cable 3 C, 4 sq.mm copper conductor pvc insulated cable suitable for submersible pump set operation and with manufacturer\"s standard control panel board which is mandatory and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts, GI nipple, 40 mm dia HDPE hose of required length etc. including all accessories complete as directed by the engineer in charge - Horizontal submersible pump - 280 LPM each pump and 174 m head |
| 967 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work - 150mm dia |
| 968 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. : 100 mm diameter |
| 969 | Providing and fixing C.I. double acting air valve of approved quality with bolts,nuts, rubber insertions etc. complete: 50 mm dia |
| 970 | Supplying and fixing C.I. dirt box strainer in between bore well pump & valve with necessary nuts, bolts, rubber insertions etc. conforming to IS : 2373, complete and as directed by the Engineer in charge - 100 mm dia dirt box strainer |
| 971 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc.- 80mm dia nominal bore |
| 972 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cementmortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 973 | Providing and constructing bed block in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 nominal size) for CPVC pipeline with necessary excavation in all types of soil except hard rock including shoring, centering and shuttering, strutting, propping & curing concrete etc. as per the drawing and as per direction of Engineer in charge - Size of 0.20 m x 0.20 m x 0.15 m |
| 974 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete - 450mm dia RCC pipe |
| 975 | Supply, installation, testing, commissioning of Recommended Make 2MP IP Dome Camera indoor type of Recommended Make including necessary mounting clamps and appropriate accessories as required for satisfactory completion |
| 976 | Supply, installation, testing, commissioning of Recommended Make 2MP IP Pan Tilt Zoom (PTZ) Camera with Bracket outdoor type of Recommended Make including panel tilt mechanism, necessary mounting clamps and appropriate accessories as required for satisfactory completion |
| 977 | Supply, installation, testing, commissioning of Recommended Make 2MP IR IP H.265 Bullet camera with 2.8 to 12mm Motorized Lens, POE, SD card slot, WDR,Smart Analytics and 50M IR support, suitable IP65 enclosure for outdoor operationall-inclusive for satisfactory completion |
| 978 | Supply, installation, testing, commissioning of Recommended Make 64 Channel NVR including all accessories as required for satisfactory completion |
| 979 | Supply, installation, testing, commissioning of Recommended Make 32 Channel NVR including all accessories as required for satisfactory completion |
| 980 | Supply, installation, testing, commissioning of Recommended Make 6TB HDD including all accessories as required for satisfactory completion |
| 981 | Supply and fixing of 15U wall mount rack with tray and cable manager including all accessories as required for satisfactory completion |
| 982 | Supply and fixing of 6U wall mount rack with tray and cable managerincluding all accessories as required for satisfactory completion |
| 983 | Supply, erection of ABS Plastic junction boxes of size 150 x 150 x 75 mm suitable for out door operation with IP 65, weather proof, including 8 way 16 amps connectors cable entry hole as required with necessary mounting accessories as required. |
| 984 | Supply, installation, testing, commissioning of Recommended Make8 Port POE Switch with SFP Module |
| 985 | Supply, installation, testing, commissioning of Recommended Make24 Port POE Switch with SFP Module |
| 986 | Supply, installation, testing, commissioning of approved MakeOutdoor camera Pole with fixing |
| 987 | Supply and laying of Category 6 U/UTP 4 Pair 23AWG Cable with suitable PVC Conduit |
| 988 | Supply and laying of Category 6 U/UTP 4 Pair 23AWG armoured Outdoor cable. |
| 989 | Supply, installation, testing, commissioning of Recommended Make 24 Port Patch Panel |
| 990 | Supply, installation, testing, commissioning of Recommended Make Patch Chord 1 M |
| 991 | Supply, laying, testing, commissioning of Recommended Make 6 Core Multimode OFC Cable with required end splicing, and termination and OFC to RS 485 converters etc., as required laid in suitable surface / concealed PVC conduit as required including all accessories as required. |
| 992 | Supply, installation, testing, commissioning of Recommended Make 6 Port Loaded LIU |
| 993 | Supply, installation, testing, commissioning of Recommended Make 12 Port Loaded LIU |
| 994 | Supply, fixing of Recommended Make Patch Cord - Multimode |
| 995 | Supply installation testing and commissioning of 55\" LED Ultra HD display with necessary mounting arrangements |
| 996 | Supply, erection, testing and commissioning the Single lane - Dual Point Automatic Number Plate Recognition (ANPR) System.The ANPR kit should consist of one ANPR camera plus one overview cameras (Over view camera covered under CCTV system).Following ANPR kit Features and Technical Specifications are only indicative, better features and specifications shall be provided at the time of equipment supply without any additional cost. Desired ANPR camera Features:• Captures images of vehicles travelling at high speed • 24 hour round the clock operation. Real-time Detection. Number Plate Recording as (1) Images (2) Database. Reports for (1) Entry / Exit Times (2) Frequency of Visits (3) Lean/Peak time analysis. Black List / White listsOverstay Parking Alert • High accuracy (99%) • Logs vehicles with multiple overview camera images • 1/3\" progressive scan sensor • Resolution : 2MP or better • Powerful 5-50 mm lens • IP66 and superior performance for outdoor applications • True WDR technology • In-built IR Illuminator, Average life of illuminator to be 10 yrs approx. • Global Electronic Shutter • ANPR Management system softwareThe ANPR camera should captures the images of vehicle number plates from moving vehicles in both day and night time conditions (even when the vehicle headlights are switched on, the IR lights located beneath the housing to illuminate the registration plate without blinding the driver). |
| 997 | Supply, installation, testing, commissioning of Accessories |
| 998 | Charges towards Testing & Commissioning of CCTV system |
| 999 | Supplying & Drawing unarmoured PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit2 pair |
| 1000 | Supplying & Drawing unarmoured PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit10 pair |
| 1001 | Supply installation testing and commissioning of EPBAX system with following configuration:The system shall be provided with 48 nos analogue extensions, 8 nos trunk incoming. The system should be suitable for expandable up to 240 analogue / digital / IP phones, 8 PRI ports, with add on modules, 19” Rack Mount with 4U Enclosure suitable for wall mounting, operating with 100-240 V AC, 47-60Hz, 48V DC, +20%-15%. Model : Matrix GENX 12 S / equivalent |
| 1002 | Supply, laying ofSolid polyethylene insulated Jelly filled armoured copper telecom cable, of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).5 pair armoured UG cable |
| 1003 | Supply, laying ofSolid polyethylene insulated Jelly filled armoured copper telecom cable, of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).20 pair armoured UG cable |
| 1004 | Supply, laying ofSolid polyethylene insulated Jelly filled armoured copper telecom cable, of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).50 pair armoured UG cable |
| 1005 | Supply, installation testing and commissioning of krone box of following pair of cable including all fixing accessories as required.10 pair krone box |
| 1006 | Supply, installation testing and commissioning of krone box of following pair of cable including all fixing accessories as required.20 pair krone box |
| 1007 | Supply, installation testing and commissioning of krone box of following pair of cable including all fixing accessories as required.50 pair krone box |
| 1008 | Supply installation, testing and commissioning of Caller Id Landline phone Set, 30 Incoming and 5 outgoing memory, 2 Level ringer volume switch, Mute option, Redial, call back Real-time clock with year, date and month display Set includes one base unit, one handset, one main line cord and one coil cord |
| 1009 | Providing and fixing stainless steel (Grade 304) Post / Frame for external signage made hollow tubes, Channels, Plates etc., including welding, grinding, buffing, polishing and making curvature ( Wherever required) as per approved design and fitting the same with necessary stainless steel nuts and bolts complete, fixing the post in cement concrete 1:2:4( 1 cement : 2 Coarse sand : 4 HBG 20 mm size ) with suitable arrangement as per approval of Engineer in charge ( The rate including cost of all materials, Labours, HOM and Transport charges etc., complete ) |
| 1010 | Providing and applying tack coat with bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparingthe surface & cleaning with mechanical broom. with rapid setting bitumen emulsion : On bituminous surface @ 0.25 kg /sqm |
| 1011 | 2 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete. With paving Asphalt grade VG - 30 with no solvent |
| 1012 | Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete. |
| 1013 | Excavation for road work in soil with hydraulic excavator of 0.9cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance withrequirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead up to 1000m (New road) |
| 1014 | Cleaning jungle including uprooting of rank vegetation grass brush wood, trees and sapling of girth up to 30cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared |
| 1015 | Stepped earth cutting on both sides New workshop building areaincluding cutting and loading in tippers, trimming bottom and side slopes, in accordance withrequirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead up to 1000m |
| 1016 | Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixingby mix in place method with rotavator at OMC, and compactingwith vibratory roller to achieve the desired density, complete as per clause 401 - Grading-IV- For lower sub base - Mix in place Method |
| 1017 | Providing, laying spreading and compacting graded stone aggregate to Wet Mix Macadam specification 0including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in sub -base/ base course on well prepared surface and compacting with vibratory roller to achieve thedesired density. |
| 1018 | Providing and applying primer coat with bitumen emulsion (SS) on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.70-1.0 kg /sqm using mechanical means. |
| 1019 | Providing and applying tack coat with bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparingthe surface & cleaning with mechanical broom. with rapid setting bitumen emulsion : On bituminous surface @ 0.25 kg /sqm |
| 1020 | 2 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete. With paving Asphalt grade VG - 30 with no solvent |
| 1021 | Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete. |
| 1022 | Maintenanceof earth shoulder (stripping excess soil ) from the shoulder surface to achieve the approved level and compacting with plate compactor |
| 1023 | Excavation for roadwork in soil with hydraulic excavator of 0.9cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirement of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead up to 1000m (Interlocking blocks) |
| 1024 | Construction of granular sub-base by providing graded Material, Mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 - Grading I- Plant Mix Method |
| 1025 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge.80 mm thick C.C. paver block of M-40 grade with approved color design and pattern. |
| 1026 | Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical SpecificationsRCC Grade M20 - Using Concrete Mixer - (Without formwork) |
| 1027 | Plain/Reinforced cement concrete in open foundation complete - P.C.CGrade M20 |
| 1028 | Part 10. Firefighting - Network |
| 1029 | Supplying, erecting, testing and commissioning fire hydrant pump HorizontalCentrifugal End Suction capable of delivering 2850 lpm at 50 mtr head complete with adequate HP automatic diesel engine driven pumps having the residential silencer system and other accessories fuel tank, necessary cooling system . |
| 1030 | Supply, erection, testing and commissioning of single stage Horizontalcentrifugal End Suctionpumps, ofapproved make for giving discharge of 2850 lpm at a pressure of 50 mtrdirectly coupled to suitable TEFC motor to operate 400/440 volts 3 phase 50 cycles AC supply with a terminal box suitable for the receptionof power cable termination common base plate, necessary foundation bolts. |
| 1031 | Supply, erection, testing and commissioning of centrifugal Jockey Pump of approved make, which gives a discharge of 180 lpmat 50 mtr head, with suitable electrical driven motor directly coupled to suitable HP TEFC motor to operate 400/440 volts 3 phase 50 cycles AC supply with a terminal box suitable for the receptionof power cable termination common base plate, necessary foundation bolts. |
| 1032 | Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :Materials INCOMING250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor completewith all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required,push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indicationBattery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter.All standard relays and accessories for automatic operation of diesel engineSystem ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 1033 | Supply, fixing, and commissioning of Butterfly Valvesas per IS 780/Gate valve as per with flanged ends. The valve has to be fixed using bolts , nuts , washer & rubber gasket- 200mm dia |
| 1034 | Supply, fixing, and commissioning of Butterfly Valvesas per IS 780/Gate valve as per with flanged ends. The valve has to be fixed using bolts , nuts , washer & rubber gasket- 150mm dia |
| 1035 | Supply, fixing, and commissioning of Butterfly Valvesas per IS 780/Gate valve as per with flanged ends. The valve has to be fixed using bolts , nuts , washer & rubber gasket - 100mm dia |
| 1036 | Supply, fixing, testing and commissioning of gun metalBall valves with wheel complete as required - 50mm dia |
| 1037 | Supply, fixing, testing and commissioning of Non-return valve(Water Check valves) as per IS 5132 complete with hand wheel, companion flange, nuts, gaskets, bolts etc. complete as required - 150mm dia |
| 1038 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. - 150mm dia |
| 1039 | Providing & Fixing Y-Strainer GI complete with stainless steel bucket having 0.3mm perforation, flanged ends, filtration area 1:4,PN 16 rating, complete etc.200mm dia |
| 1040 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 1041 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 1042 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe |
| 1043 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150 mm dia |
| 1044 | Supply, erection, testing and commissioning of heavy C class MS pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete (Above Ground)- 150mm dia |
| 1045 | Supply, erect, jointing, testing and commissioning MS Heavy C class in trenches (1 Mtrs below ground level).Rate quoted shall include for necessary specials like long radius bends, tees including cutting, welding, flanged joints with necessary washers, nuts, bolts etc.Rate quoted shall also include for providing anticorrosive treatment as per specification. Including cost for excavation & refilling. (Under Ground ) - 150mm dia |
| 1046 | Supply and installation of Cast Iron Butterfly valve including makingflanged joints by providing necessary nuts, bolts, gaskets(1.5 mm CAF)etc. All complete as per specification. |
| 1047 | Supply and installation of Cast Iron Non - Return Valveincluding makingflanged joints by providing necessary nuts, bolts, gaskets etc. All complete as per specification. |
| 1048 | Providing pipe support wall with necessary PCC, CC and \"C\" channels as per drawing. |
| 1049 | Supply, fixing, testing and commissioning of Yard Hydrant(PN 16) system with 63 mm dia single head landingvalve (Stainless Steel) |
| 1050 | Supply, fixing, testing and commissioning of Yard Hydrant(PN 16) system with Hose pipe 63 mm dia 15 m.long with male and female coupling at both ends |
| 1051 | Supply, fixing, testing and commissioning of Yard Hydrant(PN 16) system with Branch pipe 63 mm dia with 20 mm (nominal internal diameter) nozzle and suitable for instantons connection |
| 1052 | Supply, fixing, testing and commissioning of Yard Hydrant(PN 16) system with Pre fabricated weather proof lockable cabinet of size not less than 0.75 x 0.6 x 0.25 mtr made out of MS sheet of 16 gauge thickness having central opening and 4 mm thick glazed glass doors (Two No.) suitably marked on the outside with the letters \"FIRE HOSE\" including necessary locking arrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade. |
| 1053 | Supply, fixing, testing and commissioning of lever operated slim seal butterfly valves as per detailed specifications complete with Tamper switch, companion flange, nuts, gaskets, bolts etc. complete as required - 150mm dia |
| 1054 | Supply, erection, testing and commissioning of heavy C class MS pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete (Above Ground)- 250mm dia |
| 1055 | Supply, erection, testing and commissioning of heavy C class MS pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete (Above Ground)- 80mm dia |
| 1056 | Providing, Laying, Testing and commissioning of 250 mm dia RCC pipes of NP3 class hume pipes |
| 1057 | Sprinkler System - Supply, erection, testing and commissioning of C class GI pipes .The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete - 150mm dia |
| 1058 | Obtaining the fire license from concerned authority including all the concerned charges |
| 1059 | Supply, Installation, Testing & Commissioning of 4 Kg Capacity of ABC type fire extinguisher fixing on the floor with suitable fixture. |
| 1060 | Supply, Installation, Testing & Commissioning of 4.5 Kg capacity of CO2type fire extinguisher fixing on the floor with suitable fixture. |
| 1061 | Part 11.Common Infra works - Furniture,Equipment, Biometric & Mini truck ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.) |
| 1062 | Supply of office table (wooden top) of size 48\" (width) x 24\" (depth) x 30\" (height) with three drawers on one side. Table support leg and three drawer with lock are to be made of metal. Table top Made of 18 mm pre-laminated board duly sealed with 2 mm PVC beading on all sides. Shall have single drawer unit on right side made of 0.5 mm thick prime quality CRCA MS sheet with overall size 355.5 (W) x 559 (D) x 433.5 (H) mm in three drawer option. |
| 1063 | Supply of office use cane chair without arms: Seat and back are made from seasoned wood, caned (which blends of high and low density polyethylene) and finished with synthetic paint (Colour: Black). seat/back assembly Back size: 380 mm (W) x 400 mm (H) Seat size: 380 mm (W) x 425 mm (D) cane for seat/back, should have blends of high and low density polyethylene. cane strength The under structure assembly should be a cantilever type frame made of diameter 25.4 mm x2 mm thick MS ERW tube and powder coated (DFT 40-60 microns)( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1064 | Supply of office table (wooden top) of size 60\" (width) x 36\" (depth) x 30\" (height) with three drawers on one side. Table support leg and three drawer with lock are to be made of metal. Table top Made of 18 mm pre-laminated board duly sealed with 2 mm PVC beading on all sides. Shall have single drawer unit on right side made of 0.5 mm thick prime quality CRCA MS sheet with overall size 355.5 (W) x 559 (D) x 433.5 (H) mm in three drawer option. |
| 1065 | Supply of office use cane chair with arms: Seat and back are made from seasoned wood, caned (which blends of high and low density polyethylene) and finished with synthetic paint (Colour: Black). seat/back assembly Back size: 380 mm (W) x 400 mm (H) Seat size: 380 mm (W) x 425 mm (D) cane for seat/back, should have blends of high and low density polyethylene. cane strength The under structure assembly should be a cantilever type frame made of diameter 25.4 mm x2 mm thick MS ERW tube and powder coated (DFT 40-60 microns). The armrest tube should be of diameter 25.4 mm x2 mm thick MS ERW tube and powder coated (DFT 40-60 microns).( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1066 | Supply of steel cupboard: overall size 915 mm (W) x 485 mm (D) x 1980 mm (H) including leg height of ~120 mm. CRCA steel sheet used for the body should be 0.9 mm thick as per IS-513 1994. Should have multi bend construction with interlocking design and full length over lapping doors and sides and should have three way bolting mechanism. The vertical two doors should have hinge mounted on frame Doors The doors have one handle and lever locking mechanism with 6- Six lever Mazak Zinc Plated Lock. All steel components should undergo eight tank anti rust treatment and oven Baked epoxy polyester powder coating with 50-60 micron dry film thickness. It should sustain Salt Spray test to withstand more than 1000 hours as per IS-101, Pencil scratch hardness more than 2H, Adhesion as per DIN 53152 Standards. Configuration It should have 4 adjustable shelves made of 0.8 mm thick CRCA steel sheet with stiffener. Steel sheet shall be oven baked epoxy polyester powder coated with 40-50 dry film thickness( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1067 | Supply of Invertor welding machine, 7 KVAweighing around 10 Kg, suitable for 2.5 mm, 3.2 mm and 4 mm electrodes, make KEN or equivalent - Inverter type 400AMPS( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1068 | Supply of 580R handheld drilling machine (connected with power cord) |
| 1069 | Supply of compressor for painting, capacity of 50 Litres, discharge pressure 8 to 12 bar, air tank capacity 500 L, AC three phase, less than or equal to 40 HP( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1070 | Supply of 12 mm electric planer machine, 560W ( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1071 | Supply of portable hand planer, 10 mm, discharge pressure 8-12 barThe contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1072 | Supply of cut-off saw, 14” wheel dia, power input 2100 w, weighing less than 17 Kg ( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1073 | Supply of welding glass, black colour( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1074 | Supply of helmet to be worn by the welder, fibre made, industrial use ( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1075 | Supply of all in one tool kit, package containing: Screwdriver Bits, Hexagon Socket Wrench\"s, Precision Bits, Adaptors, Ratchet Hand Screwdrivers, Allen Keys, Masonry Drill Bits, S-Plugs, Screws, Flat-nose Pliers, Combination Pliers, 1 Tester, 1 Hammer, Cutter, Measuring Tape 3m, 1 Insulation Tape, 1 Torch, 1 Wrench, 1 Handsaw( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1076 | Supply of Jig Saw, 1000 - 3100 Rpm( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1077 | Supply of Plier 8\"-70-482 sg ( The contractor should propose two or three makes, Meeting the specifications, along with a detailed comparison and submit the same to the engineer in charge for approval, prior to ordering.) |
| 1078 | Supply of Mini Truckfor the following specifications the rate including on road cost like Vehicle cost including body, Lift time road tax, Insurance for first year, Registration charges and all other taxes.Power - 75HPEngine speed - 3200RPM Payload - 1500kg Warranty - 3 Years / 1 Lakh Km whichever is later Cylinders - 4Displacement- 2200CCService Interval - 10000 Km (Oil change )Body Size- 8.4x5.6ftTransmission - 5 Speed(5F+1R)Gearbox - Synchromesh Clutch - single plate dry clutch Gradeability - 35% Max Speed - 80 Kmph Emission - BS6Fuel Type - Diesel Fuel Tank - As per manufacturerVariants - Cabin with Flat bed load body GVW - As per manufacturerSeating Capacity - D+1 Axle Configuration - 4X2Front Suspension - Rigid with leaf springs, With telescopic shock absorber / Semi elliptical leaf springRear Suspension - Rigid with leaf springs, With telescopic shock absorber / Semi elliptical leaf springAnti Roll Bar- FrontGround Clearance - 195mmOverall Length - As per manufacturerOverall width - As per manufacturerOverall Length - As per manufacturerSteering - Power steeringService Brakes -Front : Hydraulic Disc , Rear : Hydraulic Drum colour - Client choice |
| 1079 | Supply, Installation, testing and commissioning of Biometric attendance system (BAS)through finger print with in built Time andattendance software in Drishya building, Chithranjali Studio comprising of the following :-1.Network Switch D-Link & WIFI connectivity 2.Temper proof box for Machine 3.Power backup for 4Hrs4. Attendance software with Dongle5.All other necessary accessories etc., complete. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender