| 1 | Repair / maintenance of street / security/Flame proof lights any type, flood lights, post top lanterns or any other external lights in its position fixed on pole / high mast / building structure or by taking down to ground, if required, testing all the components / parts, wiring etc, identifying and replacing the defective components like, electronic driver (in case of LED lights),connector, connection wires/ cable, MCB etc including refixing the fittingto its original position (if taken down), including repair / maint of street light control timer & junction box all as directed by Engr-in-charge. Note:(i)The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) Spares such as, electronic driver, connector, connection wire, MCB, timer spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of BOQ here-in-below. |
| 2 | (iii)The contractor\"s representative will report to concerned JE E/M at 0900hrs daily to collect the list of defectivelights fittings and will submit the completion report as per complaints received on the same daybefore 1730hrs to the JE E/M. (iv) The contractor has to rectify thedefects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M.In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall carry out repair / maint work simultaneouslyfor different areasby engaging separate team of electricians / technicians for Sprite area, LRSAM area and DRDL area in order to ensure prompt & timely rectification of defects. |
| 3 | (v) Contractor shall arrange requisite and cost sufficient number oftransport and vehicle mounted hydraulic ladder at his own cost wherever required.(vi) The contractor shall maintain proper record of repair / maintenance in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maintenance record register to Engineer-in-charge for inspection on every Monday or as and when asked for. |
| 4 | (vii) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments anddepartment shall not be responsible for any kind of mishap / accident / injury to his men.(viii) The contractor shall maintain sufficient stock of spares / material required for repair / maintenance of street lights with the concerned JE E/M against the supply only items here-in-below. |
| 5 | Supply only PVC insulated copper conductor FR grade2.5 sqmm,three core cable, ISI marked. |
| 6 | Supply only PVC insulated copper conductor FR grade1.5 sqmm,three core cable, ISI marked. |
| 7 | Supply only PVC insulated alluminium conductor FR grade 2.5 sqmm, two core flat cable,for service connections, ISI marked. |
| 8 | Re-stringing, tightening and fixing in position, the existing OH ACSR conductor LT Line phase with neutral and earth wire 230V, 2/3 wire by loosening and taking down existing binding wire from the insulator of any size of ACSR conductor and bringing it to required sag including provision of new binding wire and tightening of cross arms on each pole and requiredtrimming of tree branchesNote: 1.Span length of conductor shall be measured in running meter unit for each conductor |
| 9 | Cutting/ trimming / punning tree branches overhanging or interfering or obstructing electrical pole or street lightsin such a way that theclearance between Street light pole and tree branches should not be less than 3 mtrs around the Pole/Fitting including removing debris complete all as directed. Note: Quoted rate is deemed toinclude necessary hydraulic ladder arrangement and tree cutting machine and tools required at site. |
| 10 | M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT preparing surface for painting and applying black & yellow paint strips of 30 cms each upto 1.5 m above the PCC and applying one coat of red oxide and two coats of aluminium paint for the remaining height of pole including MS clamps, GI bracket, fittings etc and marking of pole No, 2m above the PCC muff, letter shall not be more than 6 cm height with 16 cm dia circle around the marked No. complete all as directed. Note : Quoted rate is deemed to include removal of any type of boards, direction plates etc and refixing the same after painting, in its original position with necessary bolts and nuts. |
| 11 | S&F in repairs automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, single Phase, suitable for 6KW load, comprising of 32 Amps, 3 Pole, MCB SPN, 40A power contactor and 230V digital timer switch for controlling street lights outdoor type,including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Make: Havells Cat Part: IHXSS01060 or equivalent in L&T/Legrand/Indo Asian |
| 12 | S&F in repairsautomatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, suitable for 12KW load single phase comprising of 65 Amps SP MCB, 63A power contactor and 230V digital timer switch for controlling street lights,including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Make:Havells Cat Part No : IHXTS09120 or equivalent in L&T/Legrand/Indo AsianNote:- Rate quoted shall be inclusive of necessary excavation & earth work and PCC foundation. |
| 13 | S&Fin repairs SMC junction boxes (weather proof) IP 66,on street light poles made out of thermoplastic of size not less than 375mm x 262 mm x 155 mm size withconnector for connecting incoming and outgoing of cableincluding provision of 01 No of MCB SP 06 Amps to control the pole light circuit andMS brackets made out of 32 x 4 mm flat for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incoming, outgoing of cable Complete all as directed.Make:- Sintex/Hensel or as approved by the GE |
| 14 | S&Fin repairs SMC junction boxes (weather proof) IP 66,on street light poles made out of thermoplastic of size not less than 280mm x 170 mm x 105 mm size withconnector for connecting incoming and outgoing of cableincluding provision of 01 No of MCB SP 06 Amps to control the pole light circuit andMS brackets made out of 32 x 4 mm flat for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incoming, outgoing of cable Complete all as directed.Make:- Sintex/Hensel or as approved by the GE |
| 15 | S&Fin repairs LED 90 watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 5700K includingfixing to pole/wall with necessary nuts, bolts and washers complete all as directed.Make:- Havells, Model No:- ENDURAOMNIPLUSSL90WLED757SASYTOPC / Wipro Cat par No.LR02-102-XXX-57-G2 or Equivalent in Philips/ Crompton greaves |
| 16 | S&F in repairs of LED 45watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 6500K includingfixed to pole/wall with necessary MS clamp & accessories complete all as directed.Make:- Havells cat partNo: ENDURASUNDOWNSL45WLED765PASYBOPC / Wipro cat part No. LR-02-501-XXX-57-XX or Equivalent in Philips/ Crompton greaves |
| 17 | S&F in repairs LED street light 60 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary nuts and bolts as required at site complete all asdirected. Make:- Havells cat partNo: ENDURAOMNIPLUSSL60WLED757SASYTOPC /Wipro Cat part No.LR02-331-XXX-67-XX or Equivalent in Philips/ Crompton greaves |
| 18 | S&F in repairs LEDstreet light 100 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary nuts and bolts as required at site complete all as specified and directed. Make:- Havells Model No: ENDURAOMNIPLUSSL100WLED757SASYTOPC / Wipro Cat part No.LR06-311-XXX-67-XX or Equivalent in Philips/ Crompton greaves |
| 19 | S&Fin repairs LED 150 watt flood light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 5700K includingfixing to pole/wall with necessary nuts, bolts and washers complete all as directed.Make:- Havells, Model No:- JETAIRISFL150WLED757ARNBLTG / Equivalent in Philips/ Crompton greaves |
| 20 | S&Fin repairs LED 120 watt highbay light fitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mass pole/truss with necessary nuts, bolts and washers complete all as directed.Make :- Havells, Model No:- SAUCERGENXHBP120WLED757P90DBOLTG or Equivalent in Philips/ Crompton greaves |
| 21 | S&Fin repairs LED 150 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mass pole/truss with necessary nuts, bolts and washers complete all as directed.Make :- Havells, Model No:- SAUCERGENXHBP150WLED857PNBBORL or Equivalent in Philips/ Crompton greaves |
| 22 | S&Fin repairs LED 185 watt high mast light fitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mass pole/truss with necessary nuts, bolts and washers complete all as directed.Make:- Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Philips/ Crompton greaves |
| 23 | S&F in repairsIntegral LED bollards 8 watt with opal acrylic diffuser made of extruded aluminium housing and IP65 protection including PCC foundation with suitablephospher bronze/GI nuts and bolts for fixing the bollard as per site requirement complete all asdirected Note:-Rate quoted shall be inclusive of necessary excavation 150 X 150X 150 and PCC fillingrequired.Make- Havells Cat Part No. BAMBOOBLS8WLED830PSYMTOPC or equivalent in Wipro/Philips |
| 24 | S&F in repairs 70 watt, 5700K, LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection Make :- Havells Cat No. CORALMAXIPT70WLED830PSYMTOPC or eqv Philips/ Wipro. |
| 25 | S & F in repairs LED flame proof tube light fitting, housing only, suitable for LED T8 2x18 W LRD retrofit tube including lamp and integral reflector made of alluminium alloy LM6, bipin holders connector block, etc., and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size.Make :- Shakti Fixtures Pvt Ltd or equivalent in Sudhir |
| 26 | S & F in repairs LED flame proof tube light fitting, housing only, suitable for LED T8 1x20 W LRD retrofit tube including lamp and integral reflector made of alluminium alloy LM6, bipin holders connector block, etc., and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size.Make :- Shakti Fixtures Pvt Ltd cat Part no. SZHTLXX1-20FLP or equivalent in Sudhir |
| 27 | S & F in repairs Flame proof LED highbay light fitting 70W with cast aluminium housing & toughened glass suitable for hazardous area ighting. IP65/IP66 > 100lm/watt and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size.Make :- Shakti Fixtures Pvt Ltd cat Part no. SZHHCCX070-FLP or equivalent Sudhir |
| 28 | S & F in repairs Flame proof LED highbay light fitting 100W with cast aluminium housing & toughened glass suitable for hazardous area lighting. IP65/IP66 > 100lm/watt and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size.Make :- Shakti Fixtures Pvt Ltd cat Part no. SZHHCCX100-FLP or equivalent Sudhir |
| 29 | Supply & Laying, jointing & testing of XLPE UG LT cables,insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs for the following cable sizes all asdirected.Make: HAVELLS/UNIVERSAL/CCI/GLOSTER/ KEI/ POLYCAB/KEC INTERNATIONAL (RPG) |
| 30 | 6 sqmm 4 core |
| 31 | 10 sqmm 4 core |
| 32 | 16 sqmm 4 core |
| 33 | 25 sqmm 3.5 core |
| 34 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables and getting out in soft/loose soil complete all asdirected. |
| 35 | Returning, filiing in, including spreading, levelling watering and well ramminginlayers not exceeding 25 cm thick each, using soil complete all as directed. |
| 36 | Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified. |
| 37 | Supply & Lay reinforced concrete pipe of 150 mm dia, 2 nos half round for bottom and top and before laying, excavated area shall be levelled all as directed by Engr-In- Charge . Note: One half round Top and One half round bottom together will be considered as one unit. |
| 38 | Supply and laying in repairs corrugated HDPE pipe of40mm dia for cable protection confirming IS-14930 1 & 2 , in trenches or fixing to the pole with necessary accessories complete all as directed.Make:- Astral/Sudhakar or equalent ISI certified manufacturer. |
| 39 | S&F in repair light gradeGI pipe bracket of 40 mm dia, 1.2mtr long, bent to shape for street light fitting fixed on pole using new 2 Nos FI clamps, nuts, bolts and washers for fixing on steel pole complete all asdirected. |
| 40 | S&F in repairs GI street light bracketwith 4 feet mast armfor poles SP-25 to SP-31 as per the site requirements fixing on top of the pole with necessary nuts and bolts including shifting the existing street light from the bracket and connecting up with three core flexible cable by making necessary holes on the poles complete for passing the copper cable concealed in the poleincluding removing of spikes installed on existing pole complete all asdirected. |
| 41 | M&L for Earthingwith GI plate electrode 600x 600x 6 mm thick buried directly in ground vertically to a depthnot less than 2.25 mtr deep below normal ground level with top edge of earth plate, not less than 1.5 mtr below normal ground level connected to GI wire of size 4 mm by means of bolts, nuts/check nuts and washers etc of galvanised iron, protected by 15 mm dia galvanised iron pipe, light gradeupto a length of 7.5 mtr away from earth electrode and connected to main switch/control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber,40 mm thick RCC cover slab 1:2:4 type B1 with 8 mm dia TMT Bars at 140 mmc/c both ways,GI funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in Electrical plate No. 3of SSR Part I and testing complete including removing unserviceableearthing material completeall asdirected.Note : GI earth wirebeyond 7.5 metres will be measured and paid separately. |
| 42 | S&F in repairsgalvanised steel earth wire of 4mm dia on the over head LT pole with the help of aluminium tapes/ binding wire and necessary clamps for fixing the earth wire, providing the required sag for avoiding tension in earth wire complete all as directed. |
| 43 | S&F cable jointing kit forstraight through joint (epoxy) for 1.1 KV grade XLPE, PVC insulated and sheathed aluminium conductor under ground cable includingthimbles, nuts & bolts, washers etc and testing after jointing complete, all as directed for the following sizes.Make: M-seal/Raychem/Transeal/Denson |
| 44 | 16 sqmm to 25 sqmm 3.5 core |
| 45 | 35 sqmm to 50 sqmm 3.5 core |
| 46 | 70 sqmm to 120 sqmm 3.5 core |
| 47 | S&F in repairspolymer white , Grey or Green insulator of 11KV grade including one galvanised mild steel strap washers, bolts, washers and nuts complete all as directed.Make - RashtriyaElectrical/ BHEL/ National |
| 48 | S&F, in repairs stay assembly 20 mm dia stay rods complete with accessories as shown in electrical plate No.1 of SSR part I including loop type insulator, stay clamps, stay strands, excavation & earthwork and PCC work complete all as specified and directed.Note:- Rate quoted shall be inclusive of necessary excavation & earthwork and concrete as required. |
| 49 | M&L for paintingthe pole number on the LT/Street Light pole in circular shape with black synthetic enamel paint background andwhite synthetic enamel painted letters.Note:- The numbers and words shall be all as directed by the Engineer-in-charge. |
| 50 | S&F Electronic driverfor 25 watts LED security light fittings Make :-Is certified |
| 51 | S&F Electronic driverfor 35 watts LED security light fittings Make :- Is certified |
| 52 | S&F Electronic driver for 40 watts LED road way/Flood light/post top Make :- Is certified |
| 53 | S&F Electronic driver for 45 watts LED road way/Flood light/post top Make :- Is certified |
| 54 | S&F Electronic driver for 60 watts LED road way/Flood light/post top Make :- Is certified |
| 55 | S&F Electronic driver for 90 watts LED road way/Flood light/post top Make :- Is certified |
| 56 | S&F Electronic driver suitable for 100watts LED street light/Flood light fittings.Make :-Is certified |
| 57 | S&F Electronic driver suitable for 120watts LED street light/Flood light fittings.Make :-Is certified |
| 58 | Retro Reflective stickering round cutting of dia 100mm dia with white background & black letter of suitable size complete all as specified and directed. |