Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | APPENDIX- A- TURFING ON D/S OF SADDLE DAM |
| 2 | 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared as per specification and as per direction of Engineer in charge. |
| 3 | 30.2.1 : Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure) as per specification and as per direction of Engineer in charge. |
| 4 | 30.2.3 : Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment) as per specification and as per direction of Engineer in charge. |
| 5 | 60.2.1 : EARTH WORK FILLING- Supplying contractors own earth includingcost of conveyance androyalty and filling (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per specification and as per direction of Engineer in charge. |
| 6 | 30.2.25 : Supplying and stacking of well decayed cattlemanure at site including royalty and carriage upto 5 k.m. lead complete (cattlemanure measured in stacks will reduced by 8% for Payment) as per specification and as per direction of Engineer in charge. |
| 7 | 30.2.8 : Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge(cost of sludge, dump manure and/ or good earth to be paid separately) as per specification and as per direction of Engineer in charge. |
| 8 | 30.2.33 : Providing and fixing Neelgiri/Mexicangrass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler as per specification and as per direction of Engineer in charge. |
| 9 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil as per specification and as per direction of Engineer in charge. |
| 10 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) as per specification and as per direction of Engineer in charge. |
| 11 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) as per specification and as per direction of Engineer in charge. |
| 12 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 13 | 13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing as per specification and as per direction of Engineer in charge. |
| 14 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) as per specification and as per direction of Engineer in charge. |
| 15 | APPENDIX -B -I-REPAIRES TO CULVERTS & BRIDGES - CONSTRUCT A CULVERT CUM DRAIN AT THE MAIN ENTRANCE OF DAM |
| 16 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil as per specification and as per direction of Engineer in charge. |
| 17 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) as per specification and as per direction of Engineer in charge. |
| 18 | 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 19 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform as per specification and as per direction of Engineer in charge. |
| 20 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more as per specification and as per direction of Engineer in charge. |
| 21 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size as per specification and as per direction of Engineer in charge. |
| 22 | 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 23 | 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) as per specification and as per direction of Engineer in charge. |
| 24 | APPENDIX B - II- REPAIRES TO CULVERTS & BRIDGES - CONSTRUCTION OF CULVERTS AT KSEB JUNCTION & DAM TOP GATE |
| 25 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil as per specification and as per direction of Engineer in charge. |
| 26 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) as per specification and as per direction of Engineer in charge. |
| 27 | 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 28 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform as per specification and as per direction of Engineer in charge. |
| 29 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more as per specification and as per direction of Engineer in charge. |
| 30 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size as per specification and as per direction of Engineer in charge. |
| 31 | 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 32 | 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) as per specification and as per direction of Engineer in charge. |
| 33 | APPENDIX C - I - SAFETY & SECURITY MEASURES - CONSTRUCTION OF COMPOUND WALL WITH GATE & FENCING AT IB COMPOUND |
| 34 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil as per specification and as per direction of Engineer in charge. |
| 35 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) as per specification and as per direction of Engineer in charge. |
| 36 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) as per specification and as per direction of Engineer in charge. |
| 37 | 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 38 | 5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 39 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete as per specification and as per direction of Engineer in charge. |
| 40 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts as per specification and as per direction of Engineer in charge. |
| 41 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more as per specification and as per direction of Engineer in charge. |
| 42 | 6.1.2 : Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) as per specification and as per direction of Engineer in charge. |
| 43 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) as per specification and as per direction of Engineer in charge. |
| 44 | 13.37.1 : White washing with lime to give an even shade:New work (three ormore coats) as per specification and as per direction of Engineer in charge. |
| 45 | 13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) as per specification and as per direction of Engineer in charge. |
| 46 | 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works as per specification and as per direction of Engineer in charge. |
| 47 | 13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work as per specification and as per direction of Engineer in charge. |
| 48 | 16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade as per specification and as per direction of Engineer in charge. |
| 49 | 16.19 : Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete as per specification and as per direction of Engineer in charge. |
| 50 | APPENDIX C - II - SAFETY & SECURITY MEASURES - CONSTRUCTION OF COMPOUND WALL WITH GATE & FENCING AT DAM COMPONUD |
| 51 | 15.7.1 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar as per specification and as per direction of Engineer in charge. |
| 52 | 15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 53 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil as per specification and as per direction of Engineer in charge. |
| 54 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) as per specification and as per direction of Engineer in charge. |
| 55 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) as per specification and as per direction of Engineer in charge. |
| 56 | 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 57 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 58 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete as per specification and as per direction of Engineer in charge. |
| 59 | 5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 60 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts as per specification and as per direction of Engineer in charge. |
| 61 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more as per specification and as per direction of Engineer in charge. |
| 62 | 6.1.2 : Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) as per specification and as per direction of Engineer in charge. |
| 63 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) as per specification and as per direction of Engineer in charge. |
| 64 | 16.18.1 : Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for serarately) :- Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire as per specification and as per direction of Engineer in charge. |
| 65 | 16.19 : Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete as per specification and as per direction of Engineer in charge. |
| 66 | 16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade as per specification and as per direction of Engineer in charge. |
| 67 | 13.88 : Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete as per specification and as per direction of Engineer in charge. |
| 68 | 13.91 : Removing dry or oil bound distemper, water proofing cement paint and thelike by scrapping, sand papering and preparing the surface smooth includingnecessary repairs to scratches etc. complete as per specification and as per direction of Engineer in charge. |
| 69 | 13.87.1 : White washing with lime to give an even shade :Old work (two or more coats) as per specification and as per direction of Engineer in charge. |
| 70 | 13.37.1 : White washing with lime to give an even shade:New work (three ormore coats) as per specification and as per direction of Engineer in charge. |
| 71 | 13.98.1 : Wall painting with plastic emulsion paint of approved brand and manufactureto give an even shade:One or more coats on old work as per specification and as per direction of Engineer in charge. |
| 72 | 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work as per specification and as per direction of Engineer in charge. |
| 73 | 13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work as per specification and as per direction of Engineer in charge. |
| 74 | 13.71 : Lettering with black Japan pint of approved brand and manufacture as per specification and as per direction of Engineer in charge. |
| 75 | APPENDIX C - III -SAFETY & SECURITY MEASURES - REPAIRS & RENOVATION OF WATCHMAN AND SHUTTER OPERATORS BUILDING AT HEAD REGULATOR |
| 76 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil as per specification and as per direction of Engineer in charge. |
| 77 | 15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below as per specification and as per direction of Engineer in charge. |
| 78 | 15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet as per specification and as per direction of Engineer in charge. |
| 79 | 15.13.2 : Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area beyond 3 sq. metres as per specification and as per direction of Engineer in charge. |
| 80 | 15.28.2 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos Sheet as per specification and as per direction of Engineer in charge. |
| 81 | 15.14.1 : Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above as per specification and as per direction of Engineer in charge. |
| 82 | 15.9.1 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In Lime Mortor as per specification and as per direction of Engineer in charge. |
| 83 | 15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) as per specification and as per direction of Engineer in charge. |
| 84 | 14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) as per specification and as per direction of Engineer in charge. |
| 85 | 6.4.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand) as per specification and as per direction of Engineer in charge. |
| 86 | 14.2.1 : Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm, with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meters lead:Door chowkhats as per specification and as per direction of Engineer in charge. |
| 87 | 10.11.1 : Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 88 | 10.12 : Extra for providing and fixing steel beading of size 10 x 10 x 1.6 mm (box type), approved shape and section with screws instead of glazing clips and metal sash putty, in steel doors, windows, ventilators and composite units as per specification and as per direction of Engineer in charge. |
| 89 | 10.30.1 : Providing & fixing glass panes with putty andglazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes as per specification and as per direction of Engineer in charge. |
| 90 | 9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding as per specification and as per direction of Engineer in charge. |
| 91 | 50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood as per specification and as per direction of Engineer in charge. |
| 92 | 50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wooas per specification and as per direction of Engineer in charge. |
| 93 | 50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows(Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood as per specification and as per direction of Engineer in charge. |
| 94 | 50.9.5.1 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood/ jack wood 35 mm thick shutters as per specification and as per direction of Engineer in charge. |
| 95 | 12.1.2 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2 as per specification and as per direction of Engineer in charge. |
| 96 | 11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm as per specification and as per direction of Engineer in charge. |
| 97 | 16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 98 | 13.88 : Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete as per specification and as per direction of Engineer in charge. |
| 99 | 13.50.1 : Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood) as per specification and as per direction of Engineer in charge. |
| 100 | 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work as per specification and as per direction of Engineer in charge. |
| 101 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer as per specification and as per direction of Engineer in charge. |
| 102 | 13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade.Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture as per specification and as per direction of Engineer in charge. |
| 103 | 14.35.3 : Providing and fixing finished brass hard drawn hooks and eyes:200 mm as per specification and as per direction of Engineer in charge. |
| 104 | 50.9.15.2 : Supplying and fixing 300 mm Aluminium aldrop as per specification and as per direction of Engineer in charge. |
| 105 | 9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm as per specification and as per direction of Engineer in charge. |
| 106 | 9.100.3 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm as per specification and as per direction of Engineer in charge. |
| 107 | APPENDIX D - I - CAVITY FILLING & STREANGTHENING OF PROTECTION WALL AT LEFT,VERY NEAR TO THE MASONRY DAM |
| 108 | 15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) as per specification and as per direction of Engineer in charge. |
| 109 | 26.28.1 : Chipping of unsound/weak concrete material from slabs, beams, columns etc.with manual Chisel and/ or by standard power driven percussion type or ofapproved make including tapering of all edges, making square shoulders ofcavities including cleaning the exposed concrete surface and reinforcementwith wire brushes etc. and disposal of debris for all lead and lifts all completeas per direction of Engineer-In-Charge75mm average thickness as per specification and as per direction of Engineer in charge. |
| 110 | 26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chippedportion of RCC as per specifications and direction of Engineer-In-chargecomplete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per specification and as per direction of Engineer in charge. |
| 111 | 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per specification and as per direction of Engineer in charge. |
| 112 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. as per specification and as per direction of Engineer in charge. |
| 113 | 14.72 : Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge.The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be doneas per specification and as per direction of Engineer in charge. |
| 114 | APPENDIX D - II - CAVITY FILLING AND STREANTHENING OF PARAPET OF SADDLE DAM |
| 115 | 14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) as per specification and as per direction of Engineer in charge. |
| 116 | 26.29.1 : Cleaning of reinforcement from rust from the reinforcing bars to give it a totalrust free steel surface by using alkaline chemical rust remover of approvedmake with paint brush and removing loose particles after 24 hours of itsapplication with wire brush and thoroughly washing with water and allowingit to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter as per specification and as per direction of Engineer in charge. |
| 117 | 26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chippedportion of RCC as per specifications and direction of Engineer-In-chargecomplete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per specification and as per direction of Engineer in charge. |
| 118 | 26.38.1 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approveddesign mix concrete having the specified minimum characteristic compressivestrength [with ordinary portland cement, coarse sand and graded stoneaggregate of 10 mm maximum size in proportion as per design criteria]including the cost of centering and shuttering at edges and corners etc. asdirected by Engineer- in-Charge Note: Rates shall include the providing necessary ground wires etc. Thelevelling gauges, if used, shall be paid for separately. Payment under this itemshall be made only after proper wet curing has been done and surface hasbeen satisfactorily evaluated by sounding/tapping with a blunt metalinstrument.25mm thick in Grade M 25 with cement content not less than 330 kg per cum as per specification and as per direction of Engineer in charge. |
| 119 | 14.17 : Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead as per specification and as per direction of Engineer in charge. |
| 120 | 13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) as per specification and as per direction of Engineer in charge. |
| 121 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer as per specification and as per direction of Engineer in charge. |
| 122 | 13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) as per specification and as per direction of Engineer in charge. |
| 123 | APPENDIX -D -III - STRENGTHENING OF HOISTING PILLERS AND BEAMS AT DAM TOP |
| 124 | 26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc.with manual Chisel and/ or by standard power driven percussion type or ofapproved make including tapering of all edges, making square shoulders ofcavities including cleaning the exposed concrete surface and reinforcementwith wire brushes etc. and disposal of debris for all lead and lifts all completeas per direction of Engineer-In-Charge25 mm average thickness as per specification and as per direction of Engineer in charge. |
| 125 | 26.29.1 : Cleaning of reinforcement from rust from the reinforcing bars to give it a totalrust free steel surface by using alkaline chemical rust remover of approvedmake with paint brush and removing loose particles after 24 hours of itsapplication with wire brush and thoroughly washing with water and allowingit to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter as per specification and as per direction of Engineer in charge. |
| 126 | 26.30.1 : Drilling suitable holes in reinforced or plain cement concrete with power drivendrill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels,columns and slabs to introduce steel bars for sunshades/balconies includingfixing the steel bars in position using epoxy resin anchor grout of approvedmake but excluding the cost of reinforcement, all complete as per direction ofEngineer-In-Charge.Upto and including 12mm dia as per specification and as per direction of Engineer in charge. |
| 127 | 14.72 : Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge.The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done as per specification and as per direction of Engineer in charge. |
| 128 | 26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chippedportion of RCC as per specifications and direction of Engineer-In-chargecomplete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per specification and as per direction of Engineer in charge. |
| 129 | 5.19 : Encasing rolled steel sections, in beams and columns, with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size), including centering and shuttering complete but excluding cost of reinforcement as per specification and as per direction of Engineer in charge. |
| 130 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more as per specification and as per direction of Engineer in charge. |
| 131 | 50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete as per specification and as per direction of Engineer in charge. |
| 132 | APPENDIX E - SURVEY OF RESERVOIRS SUBMERGENCE AREA |
| 133 | od21900/2021_2022/P2 : Conducting land survey to demarcate boundary of the KIP acquired land by engaging Taluk surveyors as per revenue records and sketches ,including wages to chain man conveyance and hire charges or cost of necessary survey equipment,all labour charges for conductingsurvey ,clearing jungles,etc. for the smooth conduct of the survey etc. complete including preparation of necessary sketches.Details for 400 m as per specification and as per direction of Engineer in charge. |
| 134 | 56.12.c : Total station surveying and preparation of site plan in hilly terrain as per specification and as per direction of Engineer in charge. |
| 135 | 56.13 : Providing access to the site clearing site and making good for surveying in order to provide clear line of site devoid of any hindrance due to vegetation etc. and clearing areas for station points (This item is applicable only for sites without access such as in case of new road formation,bridge and building sites at in accessible locations) as per specification and as per direction of Engineer in charge. |
| 136 | od21911/2021_2022/P2 : Hire charges for providing 2 nos of 2nd Class boat with boatman as per direction of Engineer in charge. |
| 137 | 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared as per specification and as per direction of Engineer in charge. |
| 138 | 60.11.5 : Providing BOUNDARY STONE .- 30*30*75 cm of hard stone 15cm chiseled dressed on all four sides including top including earthwork excavation and levelling course as per specification and as per direction of Engineer in charge. |
| 139 | od23356/2021_2022/P2 : Constructing Jundahs in CC. 1:3:6 using 40mm graded metal of size 60cm.*60cm.*(75+50)/2cm. including foundation with cement concrete using 40mm metal of size 70cm.*80cm.*30cm. with cost and conveyance of all materials, labour charges and all leads and lifts etc. complete as per specification and as per direction of Engineer in charge. |
| 140 | od23359/2021_2022/P2 : Labour (Head load mazdoor) engaged for helping the survey team to the survey area at various locations of forest, with the help of experiencedhead load mazdoor for conveying surveying instruments ,food , drinking water etc.and all other materials to facilitate the survey work as per specification and as per direction of Engineer in charge. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail