}

Purchase Of Equipments In Instrumentation Engineering Department , Trainer Kit – Hays Bridg , Dual Trace Analog Cro Dual Channel, Dc To 30 Mhz, 1Mv / Div., Invert Facility In Both Channels , Time Base : 20 Ns -0.2 S / Div., Variable Hold, Kannur-Kerala

Directorate Of Technical Education-DTE has published Purchase Of Equipments In Instrumentation Engineering Department , Trainer Kit – Hays Bridg , Dual Trace Analog Cro Dual Channel, Dc To 30 Mhz, 1Mv / Div., Invert Facility In Both Channels , Time Base : 20 Ns -0.2 S / Div., Variable Hold. Submission Date for this Tender is 12-09-2022. wrist watch Tenders in Kannur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

33619144
Corrigendum : Purchase Of Equipments In Instrumentation Engineering Department , Trainer Kit – Hays Bridg , Dual Trace Analog Cro Dual Channel, Dc To 30 Mhz, 1Mv / Div., Invert Facility In Both Channels , Time Base : 20 Ns -0.2 S / Div., Variable Hold
Open Tender
Indian
Kerala
Kannur
12-09-2022

Tender Details

Purchase Of Equipments In Instrumentation Engineering Department , Trainer Kit – Hays Bridg , Dual Trace Analog Cro Dual Channel, Dc To 30 Mhz, 1Mv / Div., Invert Facility In Both Channels , Time Base : 20 Ns -0.2 S / Div., Variable HoldOff, Sweep Delay, X10 Magnification, Xy Mode Triggering : Dc-60 Mhz, Active Tv Sync Sep., Alternate Triggering, Component And Continuity Tester, 2 Level Calibrator, Overscan Indication , Capacitive Transducer Trainer Kit , Piezo Electric Transducer Trainer Kit , Ad 590 Transdcucer Trainer Kit , Potentiometric Type Circular Chart Temperature Recorder , Strip Chart Temperature Recorder , Level Transmitter ( 0-100 Cm Range, 4-20 Ma Output, 2 Wire ) , Pressure Transmitter ( 0-10 Bar Range, 4-20 Ma Output, 2 Wire ) , Pid Controller ( Universal / 4-20 Ma Input, 4-20 Ma Output, Panel Mount Type, Auto Tuning, Segment Display 4+4 Digits , I To P Converter , Control Relay 24 V Dc Coil, 2 No + 2 Nc Contacts, Rated Current – 4 A Minimum, Panel Mount Type, Ip2x Protection, Standards - Bs 5424, Iec 60947, Nf C 63-140, Vde 0660, Industrial Type 0 , Pressure Process Station Trainer Stand Alone - Tower Type Mobile Design , Can Be Able To Do The Process Control Experiments To Illustrate The Principles Of Single-Loop Control And The Calibration & Tuning Of Controllers, Transmitters, Converters And Valves. It Can Be Used To Demonstrate Feedback Control, On-Off Control, P / Pi / Pid Control, And Pressure Control. - Must Include Industrial Standard ( 4-20 ) Ma Interfacing Signals, Piezo Resistive Pressure Transmitter ( 0-7 ) Bar May Use To Sense The Pressure, Electronic Regulated Power Supply Shall Fixed For Voltage Regulation., Electro Pneumatic ( I To P ) Converter Shall Mounted To Control The Pneumatic Control Valve, Pneumatic Control Valve For Controlling Flow Of Air, Air Regulator Cum Filter Shall Provided For Air Regulation, Two Separate Pressure Tank Shall Provided As Process Tank With Pressure Gauges And Relief Valves, Air Flow Lines Shall Fitted By Flexible Hoses / Fittings For Better Reliability, Hand Valve Provisions Shall Given For Series, Parallel Connection Of Pressure Tanks, Usb / Serial Port Data Acquisition Shall Provided, Supporting Process Control Software Shall Supported By Windows 10 And Higher Os. Should Be Compatible With Labview & Matlab 1 , Level Process Station Trainer Stand Alone - Tower Type Mobile Design , Can Be Able To Do The Process Control Experiments To Illustrate The Principles Of Single-Loop Control And The Calibration & Tuning Of Controllers, Transmitters, Converters And Valves. It Can Be Used To Demonstrate Feedback Control, On-Off Control, P / Pi / Pid Control, And Level Control. - Must Include Industrial Standard ( 4- 20 ) Ma Interfacing Signals, Capacitive Level Transmitter ( 0-100 ) Cm May Use To Sense The Level, Electronic Regulated Power Supply Shall Fixed For Voltage Regulation., Electro Pneumatic ( I To P ) Converter Shall Mounted To Control The Pneumatic Control Valve, Pneumatic Control Valve For Controlling Water Flow, Air Regulator Cum Filter Shall Provided For Air Regulation, Transparent Process Fiber Tank ( Of Min 800Mm ) With Graduated Level Scale Shall Be Provided As Process Tank With With Overflow Sensor And Auto Cut Off, Air Flow Lines Shall Fitted By Flexible Hoses / Fittings For Better Reliability, A Rotameter ( 1000 Lph ) Shall Be Provided For Visual Indication Of Flow Rate. Centrifugal Pump Shall Be Used For Water Circulation. Hand Valve Provisions Shall Given For Manually Fill The Tank, Usb / Serial Port Data Acquisition Shall Be Provided, Supporting Process Control Software Shall Supported By Windows 10 And Higher Os. Should Be Compatible With Labview & Matlab , Flow Process Station Trainer Stand Alone - Tower Type Mobile Design , Can Be Able To Do The Process Control Experiments To Illustrate The Principles Of Single-Loop Control And The Calibration & Tuning Of Controllers, Transmitters, Converters And Valves. It Can Be Used To Demonstrate Feedback Control, On-Off Control, P / Pi / Pid Control, And Flow Control. - Must Include Industrial Standard ( 4- 20 ) Ma Interfacing Signals, Dp Transmitter Of 1 To 100 Lph May Use To Sense The Flow, Electronic Regulated Power Supply Shall Fixed For Voltage Regulation., Electro Pneumatic ( I To P ) Converter Shall Mounted To Control The Pneumatic Control Valve, Pneumatic Control Valve For Controlling Water Flow, Air Regulator Cum Filter Shall Provided For Air Regulation, Transparent Process Fiber Tank ( Of Min 800Mm ) With Graduated Level Scale Shall Be Provided As Process Tank With With Overflow Sensor And Auto Cut Off, Air Flow Lines Shall Fitted By Flexible Hoses / Fittings For Better Reliability, A Rotameter ( 1000 Lph ) Shall Be Provided For Visual Indication Of Flow Rate, Centrifugal Pump Shall Be Used For Water Circulation. Hand Valve Provisions Shall Given For Manually Adjust The Flow Rate, Usb / Serial Port Data Acquisition Shall Be Provided, Supporting Process Control Software Shall Supported By Windows 10 And Higher Os. Should Be Compatible With Labview & Matlab , Temperature Process Station Trainer A Self-Contained Mobile Module For Temperature Process Control Experiments To Illustrate The Principles Of Single-Loop Control And The Calibration & Tuning Of Controllers, Transmitters, Converters And Valves. It Can Be Used To Demonstrate Feedback Control, On-Off Control, P / Pi / Pid Control, Distance-Velocity Lag And Temperature Control. Should Be Compatible With Labview & Matlab , Newton’S Ring Test Trainer Kit , Air Pollution Monitoring Equipment ( Multifunctional Air Quality Monitor Device With High Precise Electrochemical Formaldehyde Sensor, Laser Particle Sensor And Carbon Dioxide Sensor Based On Ndir ) , Paramagnetic Oxygen Analyzer , 5 Kva Ups With Batteries ( Min. 4 Hrs Backup At Full Load , 3 Year Warranty ) , 8051 Microcontroller Trainer Kit ( With External Pc Keyboard , With Add On Board / In Built Digital I / O, Matrix Key Board, Seven Segment Display, Lcd Display, Traffic Light, 8 Bit Adc&Dac, Stepper Motor Control, Dc Motor Control, Ad 590 Temperature Ic Interfacing 0 , Basic Electronic Trainer Kit Completely Self-Contained Stand Alone Unit., Built In Ic Based Dc Regulated Power Supply.Test Points Provided On Panel At Various Stages In The Circuit. Set Of Required Number Of Patch Cords.Strongly Supported By A Comprehensive Instruction Manual Complete With Theory And Operating Details. Experiments To Study The Characteristic Of Diode And Zener Diode. To Study The Rectifier Circuit. To Study The Characteristic Of Transistor And Application Of Transistor. To Study The Characteristic Of Ujt. To Study The Characteristic Of Fet. To Study The Characteristic Of Mosfet. To Study The Characteristic Of Scr. To Study The Characteristic Of Triac. To Study The Characteristic Of Diac. To Study The Characteristic Of Network Theorem. , Hand Pump Pressure Calibrator 0-40 Bar With Pressure And Vacuum Standard Gauges Measuring Parameters: Pressure And Vacuum; Vacuum Range: Ambient To -0.9 Kg / Cm²; Pressure Range: Ambient To 30 Kg / Cm² ( 30 Bar ) Material Of Construction: Aluminium And Stainless Steel; Supply Scope: 1 Unit Of Calibrator, 3 Nos Reducers ( 1 / 4, 1 / 2, 3 / 4 ) Applications: Calibration Labs, Field Calibration, Pressure Gauge Calibration, Pressure Transmitter Calibration. , Universal Multifunction Process Calibrator To Calibrate Various Types Of Process Control Instruments That Accept Mv, Ma, And Resistance Inputs. Multifunction Calibrator That Can Simultaneously Source And Measure Voltage, Current, Resistance, Tc, Rtd, Frequency, And Pulse Signals. Applications: Calibration Of Process Control Instruments, Temperature & Pressure Transmitters, I / P Convertors, Field-Level Transmitters, Flow Transmitters, Etc , Flow Measurement Using Orifice Plate Trainer Kit. This Setup Should Be A Table Top Model, It Comprises Of Source And Measuring Tank. The Measuring Tank Shall Be Of Acrylic With Liters Graduated. A Small Fhp Pump Should Be Fitted To Circulate The Water. An Orifice Meter With U-Tube Manometer Should Be Provided To Measure The Flow Rate. A Rotameter Should Provided To Measure The Exact Flow Rate. A Valve Shall Provided To Control The Water Flow Rate. Digital Timer Shall Provided To Notedown The Duration Of Flow. , Flow Measurement Using Venturimeter Trainer Kit. This Setup Should Be A Table Top Model, It Comprises Of Source And Measuring Tank. The Measuring Tank Shall Be Of Acrylic With Liters Graduated. A Small Fhp Pump Should Be Fitted To Circulate The Water. An Venturimeter Meter With U Tube Manometer Should Be Provided To Measure The Flow Rate. A Rotameter Should Provided To Measure The Exact Flow Rate. A Valve Shall Provided To Control The Water Flow Rate. Digital Timer Shall Provided To Notedown The Duration Of Flow. , Industrial Digital Stop Watch 1 / 100Th Second Resolution For 30 Minutes, 1 Second Resolution Up To 24 Hours, 12 Or 24 Hour Clock Format, Timing Capacity: 23 Hrs, 59 Mins, And 59.99 Secs, Basic Accuracy: ±3 Seconds / Day , Calendar Displays Day, Month And Date , Programmable Alarm And Hourly Chime Setting Backlight Turns Off After 4 Seconds, Water Resistant Housing And Neckstrap , Digital Multimeter Voltage: Dc: 1000 Volts; Ac: 1000 Volts; Dc Accuracy: ± 0.5% + 3 Digit; Ac Accuracy: ± 1% + 3 Digit;Current: Dc: 10 Amps; Ac: 10 Amps; Dc Accuracy: ± 1.5% + 3 Digit; Ac Accuracy: ± 1.5% + 3 Digit Resistance: 40 M Ohm; Resistance Accuracy: ± 1.5% + 3 Digit Capacitance: 1000 ?F; Capacitance Accuracy: ± 5% + 5 Digit Cat Iii 600 Volts Safety Rating; Big Display With Bright White Backlight Voltage, Resistance, Continuity, Capacitance Measurement Input Terminal For Ac And Dc Current Measurements Upto 10 A Current Diode Test, Data Hold, Min / Max , P To I Converter 0.2-1.0 Kg / Cm² ( 3-15 Psi ) Input & 4-20Ma Output Signal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Aug-2022 IMPORTANT NOTICE Other 12-09-2022
2 29-Aug-2022 CANCELLATION OF TENDER Other 12-09-2022

Key Value

Document Fees
INR 6254 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:
Sl. No. Item Description
1TRAINER KIT – HAYS BRIDG
2DUAL TRACE ANALOG CRO Dual Channel, DC to 30 MHz, 1mV/div., Invert facility in Both Channels ,Time Base : 20 ns -0.2 s/ div., Variable HoldOff, Sweep Delay, X10 Magnification, XY Mode Triggering : DC-60 MHz, Active TV Sync Sep., Alternate triggering,Component and Continuity Tester, 2 Level Calibrator, Overscan Indication
3CAPACITIVE TRANSDUCER TRAINER KIT
4PIEZO ELECTRIC TRANSDUCER TRAINER KIT
5AD 590 TRANSDCUCER TRAINER KIT
6POTENTIOMETRIC TYPE CIRCULAR CHART TEMPERATURE RECORDER
7STRIP CHART TEMPERATURE RECORDER
8LEVEL TRANSMITTER (0-100 CM RANGE, 4-20 MA OUTPUT, 2 WIRE)
9PRESSURE TRANSMITTER (0-10 BAR RANGE, 4-20 MA OUTPUT, 2 WIRE)
10PID CONTROLLER (UNIVERSAL/4-20 MA INPUT, 4-20 MA OUTPUT,PANEL MOUNT TYPE, AUTO TUNING,SEGMENT DISPLAY 4+4 DIGITS
11I TO P CONVERTER
12CONTROL RELAY 24 V Dc coil, 2 NO + 2 NC contacts, Rated Current – 4 A minimum, panel Mount type, IP2X protection, Standards - BS 5424,IEC 60947, NF C 63-140, VDE 0660, Industrial type 0
13PRESSURE PROCESS STATION TRAINER Stand Alone - Tower type mobile design , can be able to do the process control experiments to illustrate the principles of single-loop control and the calibration & tuning of controllers, transmitters, converters and valves. It can be used to demonstrate feedback control, ON-OFF control, P/PI/PID control, and pressure control. - Must include industrial standard (4-20)mA interfacing signals, Piezo Resistive Pressure Transmitter (0-7)Bar may use to sense the pressure, Electronic Regulated Power supply shall fixed for voltage Regulation., electro pneumatic (I to p )converter shall mounted to control the pneumatic control valve, Pneumatic Control Valve for controlling flow of air, air regulator cum filter shall provided for Air regulation, two separate pressure tank shall provided as process tank with pressure gauges and relief valves, air flow lines shall fitted by flexible hoses/fittings for better reliability, Hand valve provisions shall given for series, parallel connection of pressure tanks, USB/Serial port data acquisition shall provided, supporting process control software shall supported by Windows 10 and higher OS. SHOULD BE COMPATIBLE WITH LABVIEW & MATLAB 1
14LEVEL PROCESS STATION TRAINER Stand Alone - Tower type mobile design , can be able to do the process control experiments to illustrate the principles of single-loop control and the calibration & tuning of controllers, transmitters, converters and valves. It can be used to demonstrate feedback control, ON-OFF control, P/PI/PID control, and level control. - Must include industrial standard (4- 20)mA interfacing signals, Capacitive level Transmitter (0-100)cm may use to sense the level, Electronic Regulated Power supply shall fixed for voltage Regulation., electro pneumatic (I to p ) converter shall mounted to control the pneumatic control valve, Pneumatic Control Valve for controlling water flow, air regulator cum filter shall provided for Air regulation, Transparent Process Fiber tank (of min 800mm) with graduated level scale shall be provided as process tank with with overflow sensor and auto cut off, air flow lines shall fitted by flexible hoses /fittings for better reliability, A Rotameter (1000 LPH) shall be provided for Visual Indication of flow rate. Centrifugal Pump shall be used for water circulation. Hand valve provisions shall given for manually fill the tank, USB/Serial port data acquisition shall be provided, supporting process control software shall supported by Windows 10 and higher OS. SHOULD BE COMPATIBLE WITH LABVIEW & MATLAB
15FLOW PROCESS STATION TRAINER Stand Alone - Tower type mobile design , can be able to do the process control experiments to illustrate the principles of single-loop control and the calibration & tuning of controllers, transmitters, converters and valves. It can be used to demonstrate feedback control, ON-OFF control, P/PI/PID control, and flow control. - Must include industrial standard (4- 20)mA interfacing signals, DP transmitter of 1 to 100 lph may use to sense the flow, Electronic Regulated Power supply shall fixed for voltage Regulation., electro pneumatic (I to p ) converter shall mounted to control the pneumatic control valve, Pneumatic Control Valve for controlling water flow, air regulator cum filter shall provided for Air regulation, Transparent Process Fiber tank (of min 800mm) with graduated level scale shall be provided as process tank with with overflow sensor and auto cut off, air flow lines shall fitted by flexible hoses/fittings for better reliability, A Rotameter (1000 LPH) shall be provided for Visual Indication of flow rate, Centrifugal Pump shall be used for water circulation. Hand valve provisions shall given for manually adjust the flow rate, USB/Serial port data acquisition shall be provided, supporting process control software shall supported by Windows 10 and higher OS. SHOULD BE COMPATIBLE WITH LABVIEW & MATLAB
16TEMPERATURE PROCESS STATION TRAINER A self-contained mobile module for temperature process control experiments to illustrate the principles of single-loop control and the calibration & tuning of controllers, transmitters, converters and valves. It can be used to demonstrate feedback control, ON-OFF control, P/PI/PID control, distance-velocity lag and temperature control. SHOULD BE COMPATIBLE WITH LABVIEW & MATLAB
17NEWTON’S RING TEST TRAINER KIT
18AIR POLLUTION MONITORING EQUIPMENT (Multifunctional Air Quality Monitor device with high precise electrochemical formaldehyde sensor, laser particle sensor and carbon dioxide sensor based on NDIR)
19PARAMAGNETIC OXYGEN ANALYZER
205 KVA UPS WITH BATTERIES (Min. 4 Hrs backup at full load , 3 YEAR WARRANTY)
218051 Microcontroller Trainer kit (with external PC keyboard , with add on board / in built digital I/O, matrix key board, seven segment display, LCD display, Traffic light, 8 bit ADC&DAC, stepper motor control, dc motor control,AD 590 temperature ic interfacing 0
22BASIC ELECTRONIC TRAINER KIT Completely self-contained stand alone unit., Built in IC based DC regulated power supply.Test points provided on panel at various stages in the circuit. Set of required number of Patch cords.Strongly supported by a comprehensive instruction manual complete with theory and operating details. Experiments To Study the Characteristic of Diode and Zener Diode. To Study the Rectifier Circuit. To Study the Characteristic of Transistor and Application of Transistor. To Study the Characteristic of UJT. To Study the Characteristic of FET. To Study the Characteristic of MOSFET. To Study the Characteristic of SCR. To Study the Characteristic of Triac. To Study the Characteristic of Diac. To Study the Characteristic of Network Theorem.
23HAND PUMP PRESSURE CALIBRATOR 0-40 BAR WITH PRESSURE AND VACUUM STANDARD GAUGES Measuring Parameters: Pressure and Vacuum; Vacuum Range: Ambient to -0.9 Kg/Cm²; Pressure Range: Ambient to 30 Kg/Cm² (30 Bar) Material Of Construction: Aluminium and Stainless Steel; Supply Scope: 1 Unit of Calibrator, 3 Nos Reducers (1/4", 1/2", 3/4") Applications: Calibration Labs, Field Calibration, Pressure Gauge Calibration, Pressure Transmitter Calibration.
24UNIVERSAL MULTIFUNCTION PROCESS CALIBRATOR To calibrate various types of process control instruments that accept mV, mA, and resistance inputs. Multifunction calibrator that can simultaneously source and measure voltage, current, resistance, TC, RTD, frequency, and pulse signals. Applications: Calibration of process control instruments, Temperature & pressure transmitters, I/P convertors, Field-level transmitters, Flow transmitters, etc
25FLOW MEASUREMENT USING ORIFICE PLATE TRAINER KIT. This setup should be a table top model, it comprises of source and measuring tank. The measuring tank shall be of acrylic with liters graduated. A small FHP pump should be fitted to circulate the water. An orifice meter with U-tube manometer should be provided to measure the flow rate. A rotameter should provided to measure the exact flow rate. A valve shall provided to control the water flow rate. Digital timer shall provided to notedown the duration of flow.
26FLOW MEASUREMENT USING VENTURIMETER TRAINER KIT. This setup should be a table top model, it comprises of source and measuring tank. The measuring tank shall be of acrylic with liters graduated. A small FHP pump should be fitted to circulate the water. An Venturimeter meter with U tube manometer should be provided to measure the flow rate. A rotameter should provided to measure the exact flow rate. A valve shall provided to control the water flow rate. Digital timer shall provided to notedown the duration of flow.
27INDUSTRIAL DIGITAL STOP WATCH 1/100th second resolution for 30 minutes, 1 second resolution up to 24 hours, 12 or 24 hour clock format, Timing capacity: 23 hrs, 59 mins, and 59.99 secs, Basic accuracy: ±3 seconds/day ,Calendar displays day, month and date , Programmable alarm and hourly chime setting Backlight turns off after 4 seconds, Water resistant housing and neckstrap
28DIGITAL MULTIMETER Voltage: DC: 1000 volts; AC: 1000 volts; DC Accuracy: ± 0.5% + 3 digit; AC Accuracy: ± 1% + 3 digit;Current: DC: 10 amps; AC: 10 amps; DC Accuracy: ± 1.5% + 3 digit; AC Accuracy: ± 1.5% + 3 digit Resistance: 40 M ohm; Resistance Accuracy: ± 1.5% + 3 digit Capacitance: 1000 µF; Capacitance Accuracy: ± 5% + 5 digit CAT III 600 volts safety rating; Big display with bright white backlight Voltage, resistance, continuity, capacitance measurement Input terminal for AC and DC current measurements upto 10 A current Diode test, data hold, min/max
29P TO I Converter 0.2-1.0 kg/cm² (3-15 PSI) input & 4-20mA output signal
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail